Tender For Design, Fabrication, Supply, Installation, Testing Commissioning Of Walk In Cold Storage Chamber 1 No To Be Installed Inside Mortuary Of Gmch Jammu.
Tender Overview
Project Description
Design, Fabrication, Supply, Installation, Testing Commissioning Of Walk In Cold Storage Chamber 1 No To Be Installed Inside Mortuary Of Gmch Jammu.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 24-Nov-2022 | EXTENSION | Date | 28-Nov-2022 |
| 2 | 25-Nov-2022 | corrigendum | Other | 28-Nov-2022 |
BOQ
| Sl. No. | Item Description |
| 1 | Design, Fabrication, Supply, Installation, Testing & Commissioning of walk in cold storage chamber – 1 No to be installed inside Mortuary of GMC&H Jammu (Blue Star/Voltas/carrier/Diakin/Mitsubishi/Hitachi) with actual capacity of 4 TR for room- 2 No.(1W & 1 S) air cooled with cooling capacity three phase (50000BTU/hr @ -4 evap. Temp. and condensing temp of 45°C.) The job includes refrigerant piping led strictly as per the instructions and recommendations of air conditioning equipment manufacturer. After the installation of piping, the system shall be pressure tested using Nitrogen at a pressure of 20 kg/sq.cm. The pressure shall be maintained in the system for a minimum period of 2 hours and finally charging of R-R404/134a refrigerant as per requirement.The job also includes Providing & Fitting of the following :->Wall & ceiling Insulation= 60 mm thick puff (having density 40±2 Kg/m³)with exposed & internal sides of SS-304 unexposed sides in PPGI for cold room door alongwith cam lock for puf panel interlocking & allied accessories >Door of size & type- 42”x78” -60 mm SS/SS Flush door-1No. clear opening hinge door flush type and allied accessories viz. kick plate, door closer, hinges etc. The door is to be fitted with emergency alarm system.>Floor = Min. 60 mm anti skid Kota stone after proper civil foundation for specified area.>Evaporator Body material= stainless steel 304 grade >Refrigerant=R404/134 a >External Room Dimension- 1No.(LxBxH) =12\"6\"’ x 24’ x 10’>Desired Room Temperature=+2 to +8 deg C>Product Stored=Dead Bodies inside cold storage chamber. The job includes complete testing of the units(electrical & mechanical from S. No. 1 to 5 of this estimate) at full load & no load.The rates are inclusive of supply of materialfitting ,civil works, carriage , labour charges and taxes. The job is complete on turnkey basis. The job also includes dismatling of the existing defunct12 Box type Morturary cabinets by way of arranging suitable manpower & tranporting same outside hospital premises and the rates quoted may be less by the value of the scrap) . All tools & tackles alongwith trained technicians/workers are to be arranged by the executingagency. |
| 2 | Supply, installation, testing and commissioning of 3 phase digital display having 415volts, 50 Hz Servo controlled Voltage stabilizer(unbalanced type) of 40 KVA capacity having following specifications :- I. Capacity = 40 KVA II. Input Voltage Rang Extended =120 V to465 V III. Output Voltage = 380 V / 400 V / 415 VIV. Regulation = - 1% , Efficiency=96%V. Input Frequency = 50 Hz ± 3HzVI. Motor drive Heavy duty AC SynchronousMotor VII. Indication Mains On Output, On Low Cut-off ,High Cut-offVIII. Metering= Analog Voltmeter to read Input & Output Voltage to each phaseIX. Operating Temperature. 45º CX. Duty cycle Continuous XI. Nature of Cooling - Oil Cooled.XII. Protection= Over Voltage, Under Voltage, Over Load Short Circuit.XIII. Stabilizer Standard As per IS 9815 Oil Standard As per IS 335.XIV. Filling ofsuperior quality of T.oil up to itsmaximumLevel of suitable grade is included in the job. (Requisite Chemical earthing with proper Aluminum strip of 25 mm for cold storage and servo & electric panel is included)XV. Make: A.E/Continental or equivalent |
| 3 | Providing, laying, installation & testing of 16 mm² 4- core PVC insulated XLPE sheathed armored aluminum Power cable conforming to latest IS-1554 code with manufacturers test certificate. The Job also includes providing & fitting of suitable size copper thimbles duly crimped with hydraulic crimping tool at both cable ends. The cable is to laid trough walls /roofs/rooms etc after proper saddling.All tool and tackles and other necessary equipments for lifting /lowering shall be arranged and provided by the contracting agency. Work shall be completed in all the respect as per site condition.The job later on includes testing the unit on no load and full load to ensure the smooth operation of the unit makes Polycab/ Havells/Gloster |
| 4 | Providing and laying of copper tubing of below mentioned size for carrying refrigrant. The job also includes insulating the copper pipelinewith nitrilic foam, topping up withR-R- 404/134 refrigrant gas for additional length ofpiping etc. complete.15mm dia |
| 5 | Providing and laying of copper tubing of below mentioned size for carrying refrigrant. The job also includes insulating the copper pipelinewith nitrilic foam, topping up withR-R- 404/134 refrigrant gas for additional length ofpiping etc. complete.10mm dia |
| 6 | Control panel:-Supply, installation, testing & commissioning of main cubical panel free standing type, dust & vermin proof fabricated out of 16 SWG MS sheet to be laid over MS angle frame internally wired. The panel shall have modular construction with incoming and outgoing MCCB’s housed in an enclosure forming the basic module. Cable-way module, metering module and MCB module have to be added the basic module. Each section or the module shall be compartmentalized with pin type hinged open–able shutter with quarter swing locks. Only shutter of bus bar module shall be fixed with nuts and bolts. The panel should be equipped with following items integrated together for operation & control of the connected machinery / equipment. The panel is to be properly mounted on wall with dash fastners.All the internal wiring used shall be of suitable rating for individual component of the panel:-ii. Bus bar ModuleCopper Bus bars, 100A, 04 Nos. TPN mounted on insulators. The bus bars shall be provided with heat shrinkable type PVC sleeves duly colour coated.Cubical 01& 02:- For 100A rated, 415 volt, TPN switch disconnector.Metering Module (MCCB 200 A with 25 KA- 1 No & MCCB -100 A- 1 No. with 25 KA)a. One No. digital voltmeter (industrial type) 0-500 V, 96mm2 with on/off 3-way selector switch and fuse.b. One No. digital ampere meter (industrial type), 0-200A, 96mm2, with matching CT ratio and on/off 3-way selector switch.c. 03 Nos. Neon type phase indication type lamps. Cubical 03:- 63 A MCB for Cooling Machine # 1Cubical 04 :- 63 A MCB for Machines # 2Cubical 05:- For 16 A - 4 No. MCCB for lighting purpose of Machine room . Note:- Name plate to indicate the equipment of circuit controlled by the switches shall be fixed on the panel.The job also includes providing & fitting of proper illumination with 300-400 lux with requisite wiring and proper saddling & conduting . |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender