| 1 | 11 KV (HT) Line(Note: For detailed specifications please refer attached SBD which forms a part of the tender) |
| 2 | Supply, Loading, Transportation, Insurance, Unloading, Carriage,Delivery at Site including handling, preservation and proper storage at site. |
| 3 | 8 Mtr. Long ST Poles (410, SP-15)(As per recommended IS/REC Standard) |
| 4 | 30 mm2 ACSR (Weasel) Conductor with PG clamps of required size (as per site requirement) (As per recommended IS/REC Standard) |
| 5 | GI Channel Cross-arm (75 x 40x6mm) withGI Angle Braces, GI Pole Top Bracket (50x50x6 mm) including GI Back Clamps of 50X8 mm for fixing Cross arm and pole top bracket without making holes in the ST pole as per REC standard. (As per recommended IS/REC Standard) |
| 6 | 11 kV Pin Insulators (polymer) with Pins (10 KN) (As per recommended IS/REC Standard) |
| 7 | 11 kV DISC WITH FITTINGS( 45 KN) (As per recommended IS/REC Standard) |
| 8 | Galvanised Stay Set with 50*mm stay clamp, guy insulator ( 02Nos), Anchor Plate(200*200*6mm) nut & bolts, 02 No turn buckles1.8mtr long 16mm diameter solid GS stay rod & 7/3.15 mm dia GI Stranded wire complete. |
| 9 | Galvanized Nuts and Bolts of sizes. |
| 10 | Erection/Installation, Testing and commisioning of material supplied at Sl. No-1.01 |
| 11 | Erection of 8 Mtr. Long ST Poles including (410, SP-15) with pit excavation and refilling of pit complete work. (As per recommended IS/REC Standard) |
| 12 | Laying, stringing and binding of 30 mm2 ACSR (Weasel) Conductor with PG clamps of required size (as per site requirement) (As per recommended IS/REC Standard) |
| 13 | Fixing / Erection of GI Channel Cross-arm (75 x 40x6mm) withGI Angle Braces, GI Pole Top Bracket (50x50x6 mm) including GI Back Clamps of 50X8 mm for fixing Cross arm and pole top bracket without making holes in the ST pole as per REC standard. NOTE: Please refer Pole drawings for details (As per recommended IS/REC Standard) |
| 14 | Fixing of 11 kV Pin Insulators (polymer) with Pins (10 KN) (As per recommended IS/REC Standard) |
| 15 | Fixing of 11 kV Disc Insulator with fitting (polymer) with Pins (45 KN) (As per recommended IS/REC Standard) |
| 16 | Fixing of Galvanised Stay Set with 50*mm stay clamp, guy insulator ( 02Nos), Anchor Plate(200*200*6mm) nut & bolts, 02 No turn buckles1.8mtr long 16mm diameter solid GS stay rod & 7/3.15 mm dia GI Stranded wire complete. (As per recommended IS/REC Standard) |
| 17 | Fixing of Galvanized Nuts and Bolts of sizes. |
| 18 | 11/0.433 kV Distribution Transformer(Note: For detailed specifications please refer attached SBD which forms a part of the tender) |
| 19 | Supply, Loading, Transportation, Insurance, Unloading, Carriage,Delivery at Site including handling, preservation and proper storage at site of 11/0.433 kV Distribution Transformer. |
| 20 | 63 kVA, 11/0.433 kV Distribution Transformer, Energy Efficiency Level-II, Al Wound, oil filled, with LT cable termination box with detachable Aluminium Gland Plate.(As per recommended IS/REC Standard) |
| 21 | 8 Mtr. LongST Poles (410 SP-15)(As per recommended IS/REC Standard) |
| 22 | Gapless Surge Arrestor,9 kV,10 kA, LA with (polymer) housing, Station Type (As per recommended IS/REC Standard) |
| 23 | 11 kV Horn,Gap Fuse Set, 3-phase, 200A (As per recommended IS/REC Standard) |
| 24 | 11 kV,G.O AB Switch , 3-phase, 200A (As per recommended IS/REC Standard) |
| 25 | GI Channel, GI Cross Arms (100x50x6mm) / (75x40x6 mm) / GI Angles (50x50x6 mm) with 50X8 mm GI Back clamps without drilling/punching holes in the ST poles. (As per recommended IS/REC Standard) |
| 26 | Galvanised Stay Set with 50*mm stay clamp, guy insulator ( 02Nos), Anchor Plate(200*200*6mm) nut & bolts, 02 No turn buckles1.8mtr long 16mm diameter solid GS stay rod & 7/3.15 mm dia GI Stranded wire complete. (As per recommended IS/REC Standard). |
| 27 | 185 mm sq Cable PVC FRLS with Al Thimbles |
| 28 | 11 kV Pin Insulators (polymer) with Pins (10 KN) (As per recommended IS/REC Standard) |
| 29 | 11 kV Disc Insulators (polymer) Complete with fitting (45 KN) (As per recommended IS/REC Standard) |
| 30 | Galvanized Nuts and Bolts of sizes. |
| 31 | Sub station earthingby GI Pipe 40 mm dia 4 mm wall thickness or GI Rod 20mm, 2.5 mtr long through GI Strip of 50X6 mm for 1 No. Neutral Earthing and through GI Strip of 25X3 mm for 2 Nos transformer body Earth, 2 Nos Pole Earth, 1 No. LA Earth and 1 No. GO handle Earth (Note: For LA Earth 1 pipe/rod shall be kept separate) with Earthing Insulators, GI Nuts, Bolts and GI Clamps. (As per recommended IS/REC Standard) |
| 32 | Sundry Items/LT Fuse Set (As per recommended IS/REC Standard) |
| 33 | Erection/Installation, Testing and commisioning of material supplied at Sl. No-3.01 |
| 34 | Installation of 63kVA, 11/0.433 kV Distribution Transformer, Energy Efficiency Level-II, Al Wound, oil filled, with LT cable termination box with detachable Aluminium Gland Plate.(As per recommended IS/REC Standard) |
| 35 | Erection of 8 Mtr. Long ST Poles including (410, SP-15) with pit excavation and refilling of pit complete work. (As per recommended IS/REC Standard) |
| 36 | Installation of Gapless Surge Arrestor,9 kV,10 kA, LA with (polymer) housing, Station Type (As per recommended IS/REC Standard) |
| 37 | Installation of 11 kV Horn,Gap Fuse Set, 3-phase, 200A (As per recommended IS/REC Standard) |
| 38 | Installation of 11 kV,G.O AB Switch , 3-phase, 200A (As per recommended IS/REC Standard) |
| 39 | Fixing / Erection of GI Channel, GI Cross Arms (100x50x6mm) / (75x40x6 mm) / GI Angles (50x50x6 mm) with 50X8 mm GI Back clamps without drilling/punching holes in the ST poles. (As per recommended IS/REC Standard) |
| 40 | Fixing of Galvanised Stay Set with 50*mm stay clamp, guy insulator ( 02Nos), Anchor Plate(200*200*6mm) nut & bolts, 02 No turn buckles1.8mtr long 16mm diameter solid GS stay rod & 7/3.15 mm dia GI Stranded wire complete. (As per recommended IS/REC Standard). |
| 41 | Fixing / Crimping of 185 mm sq Cable PVC FRLS with Al Thimbles |
| 42 | Fixing of 11 kV Pin Insulators (polymer) with Pins (10 KN) (As per recommended IS/REC Standard) |
| 43 | Installation of 11 kV Disc Insulators (polymer) Complete with fitting( 45 KN) (As per recommended IS/REC Standard) |
| 44 | Fixing of Galvanized Nuts and Bolts of sizes. |
| 45 | Excavation of Earthing Pits of dia = 650 mm and depth= 3000 mm, Installation and fixing of Sub station earthing as per REC approved arrangement/spacing by GI Pipe 40 mm dia 4 mm wall thickness or GI Rod 20mm, 2.5 mtr long through GI Strip of 50X6 mm 1 nofor neutral earthing and 25X3 mm for 2 Nos transformer body earth, 2 Nos Pole earth, 1 no. LA Earth and 1 no. GO handle earth). (Note: For LA Earth 1 pipe shall be kept separate) with Earthing Insulators, GI Nuts, Bolts and Clamps. Refilled with earth enhancement materials and earthing chamber made of brick masonary with RCC Slab Cover (Proper Earthing Value must be insured) (As per recommended IS/REC Standard) |
| 46 | Fixing of Sundry Items/LT Fuse Set (As per recommended IS/REC Standard) |
| 47 | LT Line(Note: For detailed specifications please refer attached SBD which forms a part of the tender) |
| 48 | Supply, Loading, Transportation, insurance, Unloading, Carriage,Delivery at Site including handling, preservation and proper storage at site. |
| 49 | 8 Mtr. Long ST Poles (410, SP-15) (As per recommended IS/REC Standard) |
| 50 | 30 mm2 ACSR (Weasel) Conductor with PG clamps of required size (as per site requirement) (As per recommended IS/REC Standard) |
| 51 | GI Mukky clamps with LT Shackle insulators (polymer)16KN with GI back clamps to be fixed without drilling/punching of holes on ST poles.(As per recommended IS/REC Standard) |
| 52 | Galvanised Stay Set with 50*mm stay clamp, guy insulator ( 02Nos), Anchor Plate(200*200*6mm) nut & bolts, 02 No turn buckles1.8mtr long 16mm diameter solid GS stay rod & 7/3.15 mm dia GI Stranded wire complete. (As per recommended IS/REC Standard) |
| 53 | Galvanized Nuts and Bolts of sizes. |
| 54 | Erection/Installation, Testing and commisioning of material supplied at Sl. No-5.1 |
| 55 | Erection of 8 Mtr. Long ST Poles including (410, SP-15) with pit excavation and refilling of pit complete work. (As per recommended IS/REC Standard) |
| 56 | Laying, stringing and binding of 30 mm2 ACSR (Weasel) Conductor with PG clamps of required size (as per site requirement) (As per recommended IS/REC Standard) |
| 57 | Fixing of GI Mukky clamps with LT Shackle insulators(polymer)16KN with GI back clamps to be fixed without drilling/punching of holes on ST poles.(As per recommended IS/REC Standard) |
| 58 | Fixing of GGalvanised Stay Set with 50*mm stay clamp, guy insulator ( 02Nos), Anchor Plate(200*200*6mm) nut & bolts, 02 No turn buckles1.8mtr long 16mm diameter solid GS stay rod & 7/3.15 mm dia GI Stranded wire complete. (As per recommended IS/REC Standard)As per recommended IS/REC Standard) |
| 59 | Fixing of Galvanized Nuts and Bolts of sizes. |