Tender For Provision Of Peb (Pre Engineered Bldg) For 12 Men At 161 Inf Bde Sig Coy At Rampur Under Ge 969 Ews, rampur-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Provision Of Peb (Pre Engineered Bldg) For 12 Men At 161 Inf Bde Sig Coy At Rampur Under Ge 969 Ews. Submission Date for this Tender is 17-12-2022. PEB Tenders in rampur Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

34853950
Corrigendum : Tender For Provision Of Peb (Pre Engineered Bldg) For 12 Men At 161 Inf Bde Sig Coy At Rampur Under Ge 969 Ews
Open Tender
Indian
Jammu And Kashmir
rampur
17-12-2022

Tender Details

Provision Of Peb ( Pre Engineered Bldg ) For 12 Men At 161 Inf Bde Sig Coy At Rampur Under Ge 969 Ews

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-Dec-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 17-12-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 31000.0 /-
Tender Value
INR 15.50 Lakhs /-

BOQ Items

Name of Work: PROVN OF PEB (PRE ENGINEERED BLDG) FOR 12 MEN AT 161 INF BDE SIG COY AT RAMPUR UNDER GE 969 EWS.
Sl. No. Item Description
1M&Lfor point wiring inPVCcasing caping with 1.5 Sqmm size multi stranded FRLS copper conductor cable 1.5 Sqmm including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated FRLS cable of size 1.5 Sqmm as earth continuity conductorcomplete all as specified and as directed.
2(a)One light point/fan point/Exhaust fan point controlled by one 5 Amps switch one way
3(b)One 3 pin 5 Amp switch socket outlet on independent board.
4(c)One 3 pin 5 Amp switch socket outlet on same board with accessories.
5M&Lfor point wiring in PVC casing caping with 2.5 Sqmm size multi stranded FRLS copper conductor cable including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated FRLS cable of size 2.5 Sqmm as earth continuity conductor, complete all as specified and as directed.
6S&F switch piano Flush type, single pole, one way 5 amp 240 volts, complete all as specified and as directed.
7S&FSocket outlet 2 in 1, 3 pin, 5 Amps, flush type, complete all as specified and as directed.
8S&Fswitch socket combination 2 in 1, 3 pin, 5 and 15 Amps, flush type, complete all as specified and as directed.
9Supply and fixing LED light fittings 1x20W, 220V,AC decorative box type with driver holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
10Supply and fixing ceiling rose 3 phase / PVC/ Polycarbonate, isolated body, complete all as specified and as directed.
11S&F in repairs Lamp Holder, PVC/ Polycarbonate type with back plate suitable for batten fitting complete all as specified and as directed.
12S & F MCB SP 6 to 32 Amps, 240 Volts, C Curve complete all as specified and directed.
13S & F in repairs MCB,SPN 63 Amps 240 Volts C curve, complete all as specified and as directed.
14S&F in repairs Double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8 ways, 240V with 200 Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and as directed.
15S&F exhaust fan,Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep.
16S&F 1100 V grade heavy duty cable with pvc insulated aluminium conductor served with an inner sheating of pvc tape and overall pvc sheathed in service connection suspended by insulating hangers not more than 1mtr apart including 4mm suspension wire one twin core cable flat or circular of size 16 sqmm complete all as specified and as directed.
17Supply and fix electric water heater storage type steel body with copper inner tank and heating element upto 2KW capacity 50 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc.
18Supply and fixi LED Bulb 12 Watt. Complete all as specified and as directed.
19Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1200 mm sweep, with Squirrel cage induction motor complete all as specified and directed.
20S&F in repairs stepped type electronic fan regulator for ceiling fan 1200/1400mm size, 230 volts, 6 Amps, complete all as specified.
21M&Lfor Earthing complete with galvanizedsteel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth wire of 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1, 40 mm thick cover with MS rod 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. Note : The rate is ilnclusive of necessary earth work, RFR and removal etc
22Excavation in trenches n. exc 1.5m wide and n. exc 1.5m depth for foundation etc or for shafts, wells, cesspits, manholes, peir holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out in hard/dense soil complete all as specified and as directed.
23Returning,filling in,including spreading, levelling, watering and well ramming in layers not exc. 25 Cm in hard/dense soil.Complete all as specified and as directed.
24Removing of excavated soil n. exc 50m and depositingwhere directed at a level n. exc 1.5m above the starting point.Complete all as specified and as directed.
25M&L Plain Cement concrete 1:4:8 type D-2 (40mm graded aggregate) as in foundation,filling and mass concrete complete all as specified and as directed.
26Formwork to sides of pillars, posts, struts, piers, plinth beam columns and stanchions in rough finished surface of concrete at Square.Complete all as specified and as directed.
27M&L for RCC (Nominal mix) 1:2:4 using (20mm graded agg) for foundation,including rafts, footings ,foundation beams, plinth beams, bases for columns etc,basement slabs under reamed piles and mass concrete.
28S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including crancking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.90MM dia or securing clips quality conforming to Gd I, IS 432 (part-I) or Fe-410-S or Fe-410-0.
29S&F TMT bars 6 to 8 mmdia and over, cut to length, bent to shape required, including crancking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.90MM dia or securing clips quality conforming to Gd I, IS 432 (part-I) or Fe-410-S or Fe-410-0.
30Brickwork with subclass "B" bricks, straight or curved on plan exc 6m mean radius, build in (CM 1:4). Complete all as specified and as directed.
31M&L for hardcore of gauge not exceeding 63mm deposited spread and levelled in layers not exceeding 15cm thick watered and rammed to a true surface complete all as specified and as directed.
32M&L Cement concrete 75 mm thick type C-2, 1:3:6 (40 mm graded aggregate) as in plinth protection finished even smooth without using extra cement.Complete all as specified and as directed.
33M&L Virified Ceramic tiles 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, set and jointed in neat cement slurry and pointed in white or coloured cement to match,incl screed bed 15 mm thick in CM (1:4) complete all as specified and as directed.
34S&F for 50mm thick wall panel made of 0.5mm thick not dipped galvanized steel sheet on both side with 50mm thick,layer of rigid etc free closed cell polyurethane foam with tongue and groove joint including cam lock system for interlocking fixed on base channel 30x36x1.25 mm thick density of form shall be 40 kg/cum (+- kg/cum) the panel shall be precoated as approved by GE complete all as specified and as directed.
35S&F for 40mm thick puff insulated panel made of 0.5mm thickon both side with 40mm thickrigid polyurethane foam with tongue and groove jointinterlocking for ceiling to be fixed with and both including inverted CRCA Tee secion 50x50x5 mm thick and L section of 50x50x5 mm thick to roof trusses including handling arrangements.Complete all as specified and as directed.
36S&F Powder coated Anodised Aluminium frame for sliding windows, ventilators and with one or more rebates including joining cleat and handles and other necessary fittings for fixing etc.Complete all as specified and as directed.
37S&F Powder coated Anodised Aluminium Door shutters, without sash bar, aluminium section weighting 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws etc complete all as specified and as directed.
38S&F Powder coated Anodised Aluminium window andventilators shutters, without sash bar, aluminium section weighting 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws etc complete all as specified and as directed.
39S&F 4 mm thick sheet glass, ordinary quality & glazing with oil putty in square n exc 0.5 Sqm in each pane. Complete all as specified and as directed.
40Material and Labour for aluminium anodised snap grid 605x605mm false ceiling using wall angle with main tee section of size 34.5 x 24.5 x 1.5mmand cross Tee section 24.5x24.5x1.5mm. The snap grid shall be supported at ends all along the walls with anodized aluminium angle of size 40mm x 25mm x 2mm, weighting 0.36 kg/Rm including 6 mm dia Gl suspenders (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of Gl flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5 mm dia, 40mm long complete all as specified and as directed.
41Supply and fix in repair 9mm thick Prelaminated particle boards, interior grade prelaminated one side with decorative choice lamination & other side balancing white lamination of size 60cm x 60cm suitably placed in false ceiling grid made of Aluminium complete all as specified and as directed.
42S&F for steel work in tubular trusses including special shaped washer etc. Complete using ERW or induction butt welded tubes conforming to I.S 11611979 grade complete all as specified and as directed.
43Pre-painted galvatume aluminium zinc coating Gl based profile steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
44Pre-painted galvatume aluminium zinc coating Gl based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
45M&L for preparation of new previously untreated steel surface of any description (new galvanized steel surfaces) over 10 cmm in width or girth not otherwise described to receive painting,by coating with mordant solution including washing and cleaning and applying two coats of synthetic enamel paint over a coat of red oxide primer.
46S&F mild steel plates, Fe-410 W (Gde-E250) quality B plain or chequerd, 5mm thick or over in thickness in available sizes.
47S&F of mild steel rag or lewis bolts, screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised, n exc 30 cm long complete all as specified and as directed.
48M&L for providing 75mm thick plain Cement concrete type C-2, 1:3:6 (40mm graded aggregate) as in plinth protection. Complete all as specified and as directed.
49Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed.
50Aluminium alloy, anodised 300mm sliding door with bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed.
51Butt hinges, medium weight, cold rolled mild steel (100mm) and fixed complete all as specified and as directed.
52Aluminium handles,cast type, anodised (150mm) complete all as specified and as directed.
53Aluminium anodised, barrel tower bolts of extruded section and fixed (200mm) complete all as specified and as directed.
54Septic tanks, exc, in ordinary soil, foundation in PCC 1:2:4, brick work in CM 1:4, RCC Slab covers including RCC precast manhole cover having 6mm plate embedded all around/fibre reinforced cover with angle iron frame Vent shaft and sludge chambers etc complete for 10 users.
55Construction of soakage well 2.40m internal diameter and 3.00m depth including excavation in any type of soil, foundation PCC 1:3:6 type wall honeycomb masonary with top ring RCC M-25 concrete including interseptic chamber and screen chamber made of brick masonary in CM RCC cover slab in M-25/SFRC cover.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail