Tender For Maintenance Of Office Building At Nursery Sector-5 And Other Field Offices At Dwarka. - Sh:Running Maintenance And Operation Of 82.5 Kva D.G. Set, Submersible Pump Sets, I.E.I And Compound Lighting&Repairing And Servicing Of Desert Cooler, Water Cooler And Air Conditioner ( For The Year Of 2023-24 ) , At Office Complex Central Nursery, Sector-5, Dwarka

Key Value

Document Fees
Refer document
EMD
INR 43767.0 /-
Tender Value
INR 21.88 Lakhs /-

BOQ Items

Name of Work:M/o office building at Nursery Sector-5 and other field offices at Dwarka. SH:Running Maintenance and Operation of 82.5 KVA D.G. set, Submersible pump sets, I.E.I and compound lighting&Repairing and servicing of desert cooler, water cooler and air conditioner(For the year of 2023-24) , at office complex Central Nursery, Sector-5, Dwarka.
Sl. No. Item Description
1Running Maintenance and Operation of submersible pump set and D.G. set, compound lighting, internal electrification , and other electric installtions as per inventory, terms & conditions attached.
2Supplyingof following electrical accessories suitable for 220 volt A.C. supply i/c connections, testing etc as reqd. a) SP MCB- 6 to 32 Amp.
3b) DP MCB- 6 to 32 Amp.
4c) FP MCB -63 Amp.
5d) Condensor 2.5 mfd for ceiling fans
6e) Stepped type electronic fan regulator
7f)5/6 amps switch
8g)3 pin 5/6 A socket outlet
9h)15/16 A switch
10i)6 pin 15/16 A socket outlet
1120 watt LED batten lighting luminiaries suitable for 220-240 volt AC supply
12Supplying and Replacement of 300 mm sweep extra size metallic exhaust fan i/c connection, testing etc complete as reqd.
13Supplying and Replacement of 1200 mm sweep size ceiling fan i/c connection, testing etc complete as reqd.
14Supplying and Drawing of following sizes of FLRS PVC insulated copper conductor single core cable (multi stranded) of 1.1 KV grade i/c connection & testing etc as reqd. a) 1 x 1.5 sq.mm
15b) 2 x 2.5 sq.mm
16Rewinding of 1200 mm size ceiling fan i/c change of ball bearing, bush i/c dismentaling & refixing the same, connection, testing etc as reqd i/c rebate for dismantle material.
17Lifting of submersible pump set along with flanged G.I. pipe from the deep bore well i/c dismantling of sub. Cable, G.I. pipe, flange and delivery line etc as reqd.
18Lowering of submersible pump set along with flanged G.I. pipe into the deep borewell i/c connection of flanged, G.I. pipe, delivery line, water proof jointing of sub. Cable i.c nuts, bolts, washers, rubber insertion, testing & commissioning etc as reqd.
19Servicing of 82.5 KVA D.G. set (Kirloskar make) i/c S/R of following parts/accessories, cartage testing on load etc complete as reqd. (Servicing of D.G. set has to be got done through authorised dealer of OEM) i) Oil filter --- 1 No. ii) Diesel filter (pre-micro)--- 1 set iii) Air cleaner elements --- 1 No. iv) K-cool superplus- 50-50 premix ---- 10 ltr. v) K-oil premix --- 13ltr, vi) Labour charges for servicing, functioning and testing--- 1 job vii) Radiator cleaning charges --- 1 job i/c removal & refixing
20Supplying of following sizes of XLPE Al. conductor armoured power cable of 1.1 KV grade i/c connection & testing etc as reqd. a)4c x 50 sq.mm.
21b) 2c x 10 sq.mm.
22Laying of one no. PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground i/c excavation, sand cushioning,protective covering and refilling the trench etc as reqd. i) upto 35 sq. mm
23ii) Above 35 sq. mm and upto 95 sq.mm
24Supplying and Replacement of pump setsuitable for 18”/20” sweep desert coolers with 1.5 mtr lift i/c dismantling, refixing, connection, testing etc. as required i/c rebate for old pump set.
25Supplying and Replacement of wood wool pads set with Jali suitable for 18”/20” sweep desert coolers i/c removing of old pads & binding of new pads & Jali with binding wire etc. Complete as required i/c rebate for old material.
26Supplying and Replacement of 3 Core (0.75 Sq mm) PVC insulated , PVC sheathed copper conductor flexible circular cable in desert coolers i/c connection testing etc. complete as required.
27Supplying and Replacement of 5/6 Amp, 3 pin plug top for the existing desert coolers i/c connection testing etc. Complete as required i/c rebate for dismantled material.
28Supplying and fixingof3 core copper readymade leadwith5/6 Amp, 3 pin plug top for the existing desert coolers i/c connection testing etc. Complete as required.
29Supplying and Replacement 4 MFD Capacitor for the existing desert coolers i/c connection testing etc. Complete as required i/c rebate for dismantled material .
30Supplying and Replacement of 18" x 18" and 35" height desert cooler body having water tank made out of 20 SWG MS sheetwith front grill, openable type side covers made out not less than 24 SWG suitable for 18"/20" sweep dia motor, selector switch, front grill one set wooden wool pads, 1/2 " distribution pipe, one plug top 15 amp and 3 core round wire 1.5 sq.mm.
31PVCflexible pipe
32PVC distributor
33Supplying and Replacement of new cooler motor kit 220 V AC suitable for 18”/20” sweep desert coolers in the existing/new coolers body i/c connection testing & commissioning etc. as required i/c rebate for dismantled material.
34Painting of desert coolers of 18”/20” sweep i/c supplying of enamel paint, primer, emery paper, old dhoti etc for cleaning, painting & refixing the same at existing location etc. complete as required.
35Servicing of water cooler 120/150 ltr. Per hour capacity i/c cleaning of base plate/hose plate with chemical, cleaning of water tank, checking of condenser coil & washing & cleaning of water tank, oiling/greasing of fan motor & reinstallation in the same position/location, testing etc. complete as required.
36Servicing of split type A.C. of 1.5 ton capacity i/c cleaning with chemical of condenser coil, evaporation coil, lubricating and replacement of air filter pads, reinstallation of AC in the same position testing etc. as required
37Supplying and Charging ofRefrigerant Gasof Splittype A.C./Window type of 1.5 Ton capacity i/cconnection, testing & commissioning etc. as required.
38Supplying and Replacement of the following items in the existing body i/c labour etc. as required i/c rebate for dismantled material. i) Fan motor blade Set. 18”/20” (M.S.)
39Supplying & Replacement of M.S leg arm 4 pcs. In the existing body i/c labour charge ,nut bolts, washer complete etc as required.
40Supplying andinstallationofwater cooler of60/80ltr. Per hour capacity i/cStainless steel tank , CFC free refrigerant , high energy efficient compressor ,condenser (Fin & tube type), evaporator with Cu tube , compressor (Hermetically sealed, Reciprocating compressor) , testing etc. complete as required.
41Supplying and installation ofwater UV+ RO water purifierdouble with purificationwith TDS adjuster (25 liter) ,fully automatic shutoff function automatically switched off the machine when water tank get full,testing etc. complete as required.
42Supply andreplacement of Powder Fire Extinguisher (Gas cartridge type) Capacity 04 Kg duly ISI marked conforming to IS: 15683:2006, with IS 14609, ISI marked ABC powder complete with IS 4947 ISI marked gas cartridge withsqueeze grip release valve, discharge pipe, locking arrangement, pressure gauge, operation manual and bracket. Operating Temperature: - 10ºC to + 55ºC.
43Supply andreplacement Water Fire Extinguisher gas cartridge type ISI marked conforming to IS:15683. Capacity 9 liter. Complete with IS: 4947 gas cartridge , delivery hose, squeeze grip release valve, locking arrangement, pressure gauge, operation manual and bracket. operating temprature + 5ºC to + 55ºC.
44Supplying and replacement of Hose box (24" x 24" x 10")16 guage suitable for two fire extinguisher complete in all respect.