Implementation Of Mscl Project Network , Strengthening, Capacity Enhancement, Implementation Of Scada For Power Supply Under Smart City Mission ( Scm ) In Moradabad City- 1 Supplying And Laying Of 33 Kv, 3Cx 300 Sq.Mm, Xlpe, Armoured Cable Undergrounding Workfor Existing Overhead 1 Ckt 33 Kv Line ( With Spare Cable ) By Using Horizontal Directional Drilling Technique ( 85% Of Total Length ) 2 33 Kv Polymer Disc Insulator B&S Type 70 Kn 3 33 Kv Disc Fitting B&S Type 70 Kn 4 33 Kv Composite Polymer Pin Insulator With Nut And Washers 5 33Kv Ms Danger Board With Clamp And N&B 6 33Kv Ms Number Plate With Clampand N&B 7 33 Kv Stay Set ( G.I Stray Rod 20*2100Mm, Stay Wire 7 / 8 Wire Swg , Stay Clamp Bolt , Nut & Washerwith Concerte ) As Per Ts 8 P.G. Clamp For Acsr Dog / Raccoon 9 13 Mtr. Lattice Tower ( Ungalvanised ) 10 Foundation Of Lattice Structure Including Excavation, Base Padding, Pillar, Grouting With Complete Accessories. 11 Ms Earthing Rod Of 20X2500 Mm With 25X3 Mm Gi Strip 12 Aluminium Binding Wire - 6 Swg 13 Hdpe Pipe 160 Mm For Cable Riser 14 33Kv E Bracket With N&B 15 Gi Top Channel 125X65mm, 3200 Mm With Clamp, Bolts, Nuts And Washers 16 33 Kv Line Isolator 17 33Kv 3X300 Mm2xlpe Cable 18 Heat Shrinkable Outdoor Type Termination Kit Suitable For 33Kv Xlpe 3X300 Sq. Mm. Cable Size 19 Straight Through Joint Boxes Suitable For H.T Xlpe Cable Of Size 300 Sq.Mm / 3C For 33 Kv 20 Hdpe Pipe For Cable Laying ( Pipe To Be Laid By Hdd Method ) ( For Road Crossing ) 21 Laying Of 3X300 Sq. Mm. 33 Kv Xlpe Insulated Cable Underground In Hdpe Pipe Or Trenches ( For Road Crossing ) 22 Drilling & Laying Of Ht Underground Cable Using Hdd Method Without Using Hdpe Pipe 23 Mounting Of Cable On Dp Structure ( Including Loop And Riser ) 24 Cable Route Marker 25 Dismantling Of Old Damaged Ht Poles And Transportation Up To Store 26 Dismantling Of Existing Overhead Line And Transportation Of Materials To Nearest Pvvnl Store. 27 Supplying And Laying Of 11Kv, 3Cx 185 Sq.Mm, Xlpe, Armouredcable Undergrounding Workfor Existing Overhead 1 Ckt 11 Kv Line ( With Spare Cable ) 28 11Kv 3X185 Mm2xlpe Cable 29 Heat Shrinkable Outdoor Type Termination Kit Suitable For 11Kv Xlpe 3X185 Sq.Mm. Cable Size 30 Straight Through Joint Boxes Suitable For H.T Xlpe Cable Of Size 300 Sq.Mm / 3C For 11 Kv 31 Drilling & Laying Of Ht Underground Cable Using Hdd Method Without Using Hdpe Pipe 32 Hdpe Pipe For Cable Laying ( Pipe To Be Laid By Hdd Method ) ( For Road Crossing ) 33 Mounting Of Cable On Dp Structure ( Including Loop And Riser ) 34 Laying Of 3X185 Sq. Mm. 11 Kv Xlpe Insulated Cable Underground In Hdpe Pipe / Trenches / Riser 35 Cable Route Marker 36 Hdpe Pipe 160 Mm For Cable Riser 37 11 Mtr. Lattice Tower ( Ungalvanised ) 38 Gi Top Channel 125X65mm, 3200 Mm With Clamp, Bolts, Nuts And Washers 39 11 Kv Polymer Disc Insulator B&S Type 45 Kn 40 Disc Fitting B&S Type 45 Kn 41 P.G. Clamp For Acsr Dog / Raccoon 42 11Kv Ms Number Plate For Clamp With N&B 43 11Kv Msdanger Board With Clamp, Bolts & Nuts 44 Aluminium Binding Wire - 6 Swg 45 11 Kv Stay Set ( G.I Stray Rod 16*1800 Mm, Stay 7 / 8 Swg Wire , Stay Clamp With Bolt , Nut & Washerwith Concerte ) As Per Ts 46 Ms Earthing Rod Of 20X2500 Mm With 25X3 Mm Gi Strip 47 Foundation Of Lattice Structure Including Excavation, Base Padding, Pillar, Grouting With Complete Accessories. 48 Dismantling Of Old Damaged Ht Poles And Transportation Up To Store 49 Dismantling Of Existing Overhead Line And Transportation Of Materials To Nearest Pvvnl Store. 50 Supplying And Laying Of Various Sizes Of 1.1 Kv Al Lt Cable For Lt Cable Undergrounding Work, Service Connections To Existing / New Consumerswith All Accessories. 51 1.1 Kv Pvc Cable Of 1 Cx300 Sq.Mm From Transformer Lt Bushing To Lt Feeder Pillar Box 52 Supply Of 1.1 Kv Armoured Xlpe Cable Of 3.5 Cx150 Sq.Mm From Lt Main Pillar Box To Consumer Distribution Boxes 53 Laying Of Under Ground 3.5 Cx150 Sq.Mm Lt Xlpe Cable Including Excavation Of 30Cmx120cm.Deep Trench In Pacca Road And Refilling By 25 Cm Thick Layer Of Sand A Class Bricks Covering Refiling Soil In The Remaining Portion. 54 Drilling & Laying Of3.5 Cx150 Sq.Mm Underground Cable Using Hdd Method Without Using Hdpe Pipe 55 Supply Of Xlpe Armoured Cable Of 2Cx6 Sq.Mm From Consumer Distribution Boxes To Consumer End ( Service Line ) ( For Existing Lt System To Be Converted To Underground ) . 56 Laying Of Under Ground 2Cx6 Sq.Mmlt Xlpe Cable Including Excavation Of 30Cmx120cm.Deep Trench In Pacca Road And Refilling By 25 Cm Thick Layer Of Sand A Class Bricks Covering Refiling Soil In The Remaining Portion. 57 Supply Of Xlpe Armoured Cable Of 4Cx10 Sq.Mm From Consumer Distribution Boxes To Consumer End ( Service Line ) From Imperial Tiraha To Budh Bazar Chauraha ( For Existing Lt System To Be Converted To Underground ) . 58 Laying Of Under Ground 4Cx10sq.Mm Lt Xlpe Cable Including Excavation Of 30Cmx120cm.Deep Trench In Pacca Road And Refilling By 25 Cm Thick Layer Of Sand A Class Bricks Covering Refiling Soil In The Remaining Portion. 59 Laying Of Xlpe Armoured Cable With Pvc Pipe For Consumer Connection 60 Al Lugs For Incoming And Outgoing Cables Of Vaious Sizes 61 Pvc Pipefor Consumer Connection With All Acessories For Cable Laying & Dressing 62 Road Crossing By Hdpe Pipe 160 Mm, 6 Meter, Using Hdd Method 63 Replacement Of Existing Lt Bare Lines And Damaged Ab Cable By New Ab Cable ( 3X120+ 1X95 + 1X16 ) With All Accessories Includingfor Strengthning Works . 64 9 Mtr Forlt Pole, Long Gi Steel Single Tubular Pole With All Fitting Material And Accessories With Stone Pad ( 300X300x75mm ) & Concreting Of Pole / Support ( 0.44 Cu.M. ) , 65 Ms Earthing Rod Of 20X2500 Mm, Gi Wire 6 Swg 66 Ltstay Set ( G.I Stray Rod 16*1800Mm, Stay Wire 7 / 10 Wire Swg10 , Stay Clamp Bolt , Nut & Washerwith Concerte ) As Per Ts 67 Dead End Clamps With I-Hook ( Insulated ) 68 Suspension Clamp With I-Hook ( Insulated ) 69 Lt Insulation Piercing Connectors Of 95 / 50 Sq. Mm - 70 / 35 Sq. Mm ( For Messenger Wire Jumpering & Energizing Db Neutral ) 70 Pole Clamps With Nut And Bolt 71 Holding Clamp For Round Pole With Nut And Bolt 72 Lt Insulation Piercing Connectors Of 120-50 Sq. Mm -50-35 Sq. Mm Size For Energizing Distribution Kiosk / Box 73 Lt Insulation Piercing Connectors ( 16 Sq. Mm -16 Sq. Mm ) Suitable For Street Light Connection 74 Three Phase Smc Distribution Box With Clamps 75 Lt Abc Of 3X120+1X70+1X16 Sq. Mm 76 1X35 Mm2 Xlpe Insulated Al. Cable For Energising The Distribution Boxes / Kiosks. 77 End Cap For Lt Ab Cable 78 Pg Clamps For Messenger Wire 79 Dismantling Of Existing Overhead Line And Transportation Of Materials To Nearest Pvvnl Store. 80 Dismantling Of Old Damaged Poles And Transportation Up To Store 81 Replacement Of Existing Overhead 33 Kv Old / Damaged Dog Conductor With New 33 Kv Dog Conductor With Fittings And All Accessories 82 Acsr Dog Conductor 83 13 Mtr. Stp Withconcreting Of Pole / Support ( 0.44 Cu.M. ) 84 Ms Earthing Rod Of 20X2500 Mm 85 Gi Wire 6 Swg 86 33 Kv Composite Polymer Pin Insulator With Nut And Washers 87 Aluminium Paint 88 Red Oxide Paint 89 33Kv Msdanger Board With Clamp And N&B 90 33Kv Ms Number Plate With Clampand N&B 91 G.I. Barbed Wire 92 33 Kv Polymer Disc Insulator B&S Type 70 Kn 93 Disc Fitting B&S Type 70 Kn 94 33 Kv Stayset ( G.I Stray Rod 20*2100Mm, Stay Wire 7 / 8 Swg Wire , Guy Insulator, Stay Clamp Bolt , Nut & Washerwith Concerte ) As Per Ts 95 Dismantling Of Existing Overhead Line And Transportation Of Materials To Nearest Pvvnl Store. 96 Dismantling Of Old Damaged Poles And Transportation Up To Store 97 Replacement Of Existing Overhead 11 Kv Old / Damaged Dog Conductor With New 11 Kv Dog Conductor With Fittings And Accessories . 98 Acsr Dog Conductor 99 11 Kv Polymer Disc Insulator B&S Type 45 Kn 100 Disc Fitting B&S Type 45 Kn 101 11 Kv Composite Polymer Pin Insulator With Nut And Washers 102 11Kv Ms Danger Board With Clamp, Bolts & Nuts 103 11Kv Ms Number Plate For Clamp With N&B 104 11 Kv Stay Set ( G.I Stray Rod 16*1800 Mm, Stay 7 / 8 Swg Wire , Guy Insulator, Stay Clamp With Bolt , Nut & Washerwith Concerte ) As Per Ts 105 P.G. Clamp For Acsr Dog / Raccoon 106 Armour Rod With Ferrule For Acsr Dog / Panther / Raccoon Helical Performed 107 11 Mtr. Stp-410 Sp 55 As Per Ts 108 Concreting Of Pole / Support ( 0.44 Cu.M. ) 109 Ms Earthing Rod Of 20X2500 Mm 110 Aluminium Binding Wire - 6 Swg 111 Aluminium Jointing Sleeves 112 G.I. Barbed Wire 113 Gi Wire 6 Swg 114 Gi Wire 8 Swg 115 Gi Wire 16 Swg 116 Eye Bolt 117 Turn Buckle 118 Red Oxide Paint 119 Aluminium Paint 120 11Kv `F Bracket With N&B 121 Cross Arm Holding Clamp With Nuts & Bolts 122 V-Type Cross Arm For 11Kv Line, 100X50x6 Mm, Gi 123 Guarding Angle 75X75x6 Mm, 2200 Mm Long With Holding Clamp, Packing Piece, Nut & Bolts Etc. 124 Dismantling Of Old Damaged Ht Poles And Transportation Up To Store 125 Dismantling Of Existing Overhead Line And Transportation Of Materials To Nearest Pvvnl Store. 126 Existing Transformer Strengthening Works 127 Replacement Of Old / Damaged Feeder Pillar Box 128 1.1 Kv Pvc Unarmoured Cable Of 1 Cx300 Sq.Mm From Transformer Lt Bushing To Lt Feeder Pillar Box 129 1.1 Kv Pvcarmoured Cable Of 3.5Cx150 Q.Mm Forlt Distribution Box 130 Earthing Of Transformerby Ms Earthing Rod Of 20X25000 Mm. And 6 Swg Earthing Wire Etc. 131 11Kv Tpmo Complete Set 132 11Kv Do Fuse Set ( 3 Phase ) 133 11Kv Lightening Arrestor 134 G.I. Barbed Wire 135 11Kv Ms Danger Board With Clamp, Bolts & Nuts 136 11 Kv Stay Set ( G.I Stray Rod 16*1800 Mm, Stay 7 / 8 Swg Wire , Stay Clamp With Bolt , Nut & Washerwith Concerte ) As Per Ts 137 Red Oxide Paint 138 Aluminium Paint 139 Al. Crimping Lugs 140 Renovation Of Damaged Plinth & Fencing Of Transformers 141 Repair Of Damaged Plinth Of Transformers 142 Fencing Work Of Existing Transformers With Best Available Solutions 143 Replacement Of Old / Damaged 11 Mtr, Long Gi Steel Single Tubular Pole With All Fitting Material And Accessories 144 Polymer Disc Insulator B&S Type 45 Kn 145 Disc Fitting B&S Type 45 Kn 146 Composite Polymer Pin Insulator With Nut And Washers 147 Ms Danger Board With Clamp, Bolts & Nuts 148 Ms Number Plate For Clamp With N&B 149 11 Kv Stay Set ( G.I Stray Rod 16*1800 Mm, Stay 7 / 8 Swg Wire , Guy Insulator , Stay Clamp With Bolt , Nut & Washerwith Concerte ) As Per Ts 150 11 Mtr. Stp-410 Sp 55 As Per Ts 151 Concreting Of Pole / Support ( 0.44 Cu.M. ) 152 Ms Earthing Rod Of 20X2500 Mm 153 G.I. Barbed Wire 154 Gi Wire 6 Swg 155 Red Oxide Paint 156 Aluminium Paint 157 `F Bracket With N&B 158 Cross Arm Holding Clamp With Nuts & Bolts 159 V-Type Cross Arm For 11Kv Line, 100X50x6 Mm, Gi 160 Dismantling Of Old Damaged Ht Poles And Transportation Up To Store 161 Replacement Of Old / Damaged11 Mtr, Long Gi Steel Double Tubular Pole By U / G Lattice Structure / Steel Double Tubular Pole 11 Meter Long With All Fitting Material And Accessories 162 11 Mtr. Lattice Tower ( Ungalvanised ) 163 11 Mtr. Stp-410 Sp 55 As Per Ts. 164 Polymer Disc Insulator B&S Type 45 Kn 165 Disc Fitting B&S Type 45 Kn 166 Composite Polymer Pin Insulator With Nut And Washers 167 11 Kv Ms Danger Board With Clamp, Bolts & Nuts 168 Ms Number Plate For Clamp With N&B 169 11 Kv Stay Set ( G.I Stray Rod 16*1800 Mm, Stay 7 / 8 Swg Wire , Guy Insulator, Stay Clamp With Bolt , Nut & Washerwith Concerte ) As Per Ts 170 Concreting Of Pole / Support ( 0.44 Cu.M. ) 171 Ms Earthing Rod Of 20X2500 Mm 172 G.I. Barbed Wire 173 Gi Wire 6 Swg 174 Red Oxide Paint 175 Aluminium Paint 176 `F Bracket With N&B 177 Cross Arm Holding Clamp With Nuts & Bolts 178 V-Type Cross Arm Forline, 100X50x6 Mm, Gi 179 Gi Top Channel 125X65mm, 3200 Mm With Clamp, Bolts, Nuts And Washers 180 Ms Earthing Rod Of 20X2500 Mm With 25X3 Mm Gi Strip 181 Dismantling Of Old Damaged Ht Poles And Transportation Up To Store 182 Foundation Of Lattice Structure Including Excavation, Base Padding, Pillar, Grouting With Complete Accessories. 183 Replacement Of Old / Damaged9 Mtr For Lt Pole, Long Gi Steel Single Tubular Pole With All Fitting Material And Accessories 184 9 Mtrlt Pole, Single Tubular Pole 185 Lt Clamp With Nut Bolt 186 Lt Shackle Insulator With Nut Bolt 187 Concreting Of Pole 188 Suspension Clamp With Nut Bolt 189 Ms Earthing Rod Of 20X2500 Mm With 6 Swg Gi Wire 190 Stay Set With Complete Acessories 191 Dead End Clamp With Nut Bolt 192 Ltdb Box With Clamp 193 Lt Piercing Connectors 194 Pole Clamp With Nut Bolt 195 Red Oxide Paint 196 Aluminium Paint 197 1X35 Mm2 Xlpe Insulated Al. Cable For Energising The Distribution Boxes / Kiosks. 198 Dismantling Of Old Damaged Ht Poles And Transportation Up To Store 199 Replacement Of Old / Damaged13 Mtr, Long Gi Steel Single Tubular Pole With All Fitting Material And Accessories 200 Polymer Disc Insulator B&S Type 70 Kn 201 Disc Fitting B&S Type 70 Kn 202 Composite Polymer Pin Insulator With Nut And Washers 203 Ms Danger Board With Clamp, Bolts & Nuts 204 Ms Number Plate For Clamp With N&B 205 33 Kv Stay Set Set ( G.I Stray Rod 20*2100Mm, Stay Wire 7 / 10 Wire Swg, Guy Insulator, Stay Clamp Bolt , Nut & Washerwith Concerte ) As Per Ts 206 13 Mtr. Stp 207 Concreting Of Pole / Support ( 0.44 Cu.M. ) 208 Ms Earthing Rod Of 20X2500 Mm 209 G.I. Barbed Wire 210 Gi Wire 6 Swg 211 Red Oxide Paint 212 Aluminium Paint 213 `F Bracket With N&B 214 Cross Arm Holding Clamp With Nuts & Bolts 215 V-Type Cross Arm Forline, 100X50x6 Mm, Gi 216 Dismantling Of Old Damaged Ht Poles And Transportation Up To Store 217 Replacement Of Old / Damaged13 Mtr, Long Gi Steel Double Tubular Pole With All Fitting Material And Accessories 218 13 M Lattice Tower ( Un Galvanised ) 219 Polymer Disc Insulator B&S Type 70 Kn 220 Disc Fitting B&S Type 70 Kn 221 Composite Polymer Pin Insulator With Nut And Washers 222 Ms Danger Board With Clamp, Bolts & Nuts 223 Ms Number Plate For Clamp With N&B 224 33 Kv Stay Set Set ( G.I Stray Rod 20*2100Mm, Stay Wire 7 / 10 Wire Swg, Guy Insulator , Stay Clamp Bolt , Nut & Washerwith Concerte ) As Per Ts 225 13 Mtr. Stp 226 Concreting Of Pole ( 0.64 Cu.M. ) 227 Ms Earthing Rod Of 20X2500 Mm 228 G.I. Barbed Wire 229 Gi Wire 6 Swg 230 Red Oxide Paint 231 Aluminium Paint 232 E Bracket With N&B 233 Gi Top Channel 125X65mm, 3200 Mm With Clamp, Bolts, Nuts And Washers 234 Gi Angle 65X65x6mm, 4300 Mm Long Bracing With 4 Clamps, Bolts, Nuts And Washers 235 Foundation Of Lattice Structure Including Excavation, Base Padding, Pillar, Grouting With Complete Accessories. 236 Dismantling Of Old Damaged Ht Poles And Transportation Up To Store 237 Sitc Of Lt Pillar Box, Distribution Boxes And Fixing Ofexisting / New 1 Ph, 3Ph Meters ( At Consumer Premises ) For Lt Cable Undergrounding Work, Service Connections To Existing / New Consumers 238 Lt Distribution Pillar Box 400 A 239 Lt Distribution Box 200 A ( For Consumer Distribution ) 240 Ms Earthing Rod Of 20X2500 Mm With 25X3 Mm Gi Strip 241 Foundation For Feeder Pillar Box 242 Installation Of Single Phase Meter With / Without Meter Box ( Complete Unit ) At The Premises Ofexisting / New Consumer With All Accessories 243 Installation Of Three Phase Meter With / Without Meter Box ( Complete Unit ) At The Premises Ofexisting / New Consumer With All Accessories 244 Supplying And Laying Of Armoured 3.5 Cx150 Sq.Mm, 1.1 Kv Xlpe Cable For Undergrounding Work Of Lt Overhead Line Road Crossing . 245 3.5Cx150 Mm2xlpe Cable 246 Heat Shrinkable Outdoor Type Termination Kit Suitable For Xlpe 3.5Cx150 Sq.Mm. Cable Size 247 Hdpe Pipe For Cable Laying ( Pipe To Be Laid By Hdd Method ) ( For Railway Crossing / Road Crossing ) 248 Mounting Of Cable On Pole ( Including Loop And Riser ) 249 Laying Of Armoured 3.5Cx150 Sq. Mm.1.1 Kv Xlpecable Underground In Hdpe Pipe / Trenches / Riser 250 Cable Route Marker 251 Ms Earthing Rod Of 20X2500 Mm With 25X3 Mm Gi Strip 252 Sitc Ofoil Type Transformer With Plinth And All Fitting & Accessories 253 11 / 0.40 Kv 400Kva Transformer As Per Ts 254 11 / 0.40Kv 250 Kva Transformer As Per Ts 255 St Pole 11 Mtr. Is 410 Sp-55 256 Stone Pad ( 300X300x75mm ) 257 Concreting Of Supports With Plinth ( 0.44 Cu.M. Each ) 258 M.S. Top Channel 125X65 Mm, 2240 Mm ( 10.7Kg / Mt ) With Clamp, Bolts, Nuts And Washers 259 Copper L-Piece Of Size 400X50x6 Mm For Lt Bushing Rod Of Transformer 260 Lt Aluminium Unarmoured Xlpe Cable 1X400 Sq.Mm For I / C 261 Lt Aluminium Unarmoured Xlpe Cable 1X50 Sq.Mm For Ht Jumpering 262 Lt Aluminium Unarmoured Xlpe Cable 1X240 Sq.Mm. 263 11Kv Tpmo Complete Set With Channel, Clamps And Nuts & Bolts ( As Per Specification ) 264 11Kv Do Fuse Set ( 3 Phase ) 265 11Kv Lightening Arrestor 266 M.S. Channel 100X50x2028mm ( Dropper For Fuse Set ) 267 Holding Clamps For Top Channel Tpmo & Fuse Set Etc. With Nuts & Bolts 268 Plinth Of T / F With Rcc Top Of Size 2X2x1.6 Mtr. Incl. 2 Nos. Ms Channel 269 11Kv Polymer Disc Insulator T&C Type 45 Kn 270 Disc Fittings T&C Type 45 Kn 271 11 Kv Composite Polymer Pin Insulator With Nut And Washers 272 G.I. Barbed Wire 273 11Kv Ms Danger Board With Clamp, Bolts & Nuts 274 11Kv / Lt Stay Set Complete ( As Per Annexure-9 ) 275 Earthing Of Pole By Ms Earthing Rod Of 20X2500 Mm. And 6 Swg Earthing Wire Etc. 276 Smc Lt Distribution Box With 4-Pole Mccbfor Dtr 277 Al. Crimping Lugs 400 Sq.Mm. 278 Al. Crimping Lugs 240 Sq.Mm. 279 Al. Crimping Lugs 50 Sq Mm. 280 Aluminium Paint 281 Red Oxide Paint 282 Augmentation Of 400 Kva Transformer Through Cable 283 Transformer Structure Half 4 Pole ( Gi ) 284 11 / 0.40 Kv 400Kva Transformer As Per Ts 285 11 / 0.40Kv 250 Kva Transformer As Per Ts 286 Structure Foundation 287 Sitc Of 11Kv Rmu ( 2Lbs+ 1Vcb ) 288 Lt Distribution Pillar Box 400 A With Earthing And All Accessories 289 Supply Of 11 Kv Armoured Xlpe Cable Of 3Cx185 Sq.Mm From Transformer To Rmu Unit With Spare. 290 Lt Incoming Panel With Metering Equipment & Fixing Arrangement ( Ls ) 291 Coppper L-Piece 50X225x10 Mm ( Ls ) 292 Coppper L-Piece 62X225x12 Mm ( Ls ) 293 Lt Pvc Cable Ai 3.5X400 Sq.Mm 294 Lt Pvc Cable Ai 1X400 Sq.Mm 295 Lt Pvc Cable Ai 1X240 Sq.Mm 296 4 Core Lt Mcb With Box ( Ls ) 297 Ms Danger Board Barbed Wire Including Jumper 298 Earthing Of Transformer By Ms Earthing Rod Of 20X2250 Mm & 6Swg Earthing Wire Etc. 299 11 / 0.4 Kv Substation Structure Set Complete With Rmu, Pillar Box, Ht And Lt Cable ( Without Transformer ) 300 Transformer Structure Half 4 Pole ( Gi ) 301 Structure Foundation 302 Sitc Of 11Kv Rmu ( 2Lbs+ 1Vcb ) 303 Lt Distribution Pillar Box 400 A With Earthing And All Accessories 304 Supply Of 11 Kv Armoured Xlpe Cable Of 3Cx185 Sq.Mm From Transformer To Rmu Unit With Spare. 305 Lt Incoming Panel With Metering Equipment & Fixing Arrangement ( Ls ) 306 Coppper L-Piece 50X225x10 Mm ( Ls ) 307 Coppper L-Piece 62X225x12 Mm ( Ls ) 308 Lt Pvc Cable Ai 3.5X400 Sq.Mm 309 4 Core Lt Mcb With Box ( Ls ) 310 Danger Board Barbed Wire Including Jumper 311 Earthing Of Transformer By Ms Earthing Rod Of 20X2250 Mm & 6Swg Earthing Wire Etc. 312 Scada Compatiable Ring Main Unit ( 2 Isolators + 1 Breaker ) 313 Ring Main Unit ( 2 Isolators + 1 Breaker ) For 11Kv Feeder 314 Heat Shrinkable Jointing Kit Suitable For 11 Kv Xlpe 3X185 Sq.Mm. Cable Size ( Indoor / Outdoor ) 315 Foundation Structure For Rmu For Cable Entry Etc. ( Concrete 1:3:6 ) 316 Earthing Of Rmu By Ms Earthing Rod Of 20X2250 Mm & 6Swg Earthing Wire Etc. 317 Scada Compatiable Ring Main Unit ( 1 Isolators ) 318 Ring Main Unit ( 1 Isolators ) For 11Kv Feeder 319 Heat Shrinkable Jointing Kit Suitable For 11 Kv Xlpe 3X185 Sq.Mm. Cable Size ( Indoor / Outdoor ) 320 Foundation Structure For Rmu For Cable Entry Etc. ( Concrete 1:3:6 ) 321 Earthingof Rmu By Ms Earthing Rod Of 20X2250 Mm & 6Swg Earthing Wire Etc. 322 Supply And Laying Of 33 Kv, 3Cx 120 Sq.Mm, Xlpe, Armoured Cable Undergrounding Work From 132 Kv Substation At Kanth Roadto District Court And District Hospital Via Ptc Tiraha ( Single Circuit Cable ) 323 33 Kv Polymer Disc Insulator B&S Type 70 Kn 324 Disc Fitting B&S Type 70 Kn 325 33 Kv Composite Polymer Pin Insulator With Nut And Washers 326 33Kv Ms Danger Board With Clamp And N&B 327 33Kv Smc Number Plate With Clampand N&B 328 33 Kv Stay Set Set ( G.I Stray Rod 20*2100Mm, Stay Wire 7 / 10 Wire Swg, Guy Insulator, Stay Clamp Bolt , Nut & Washerwith Concerte ) As Per Ts 329 P.G. Clamp For Acsr Dog / Raccoon 330 13 Mtr. Lattice Towerfor Cable Riser ( Ungalvanised ) 331 Foundation Of Lattice Structure Including Excavation, Base Padding, Pillar, Grouting With Complete Accessories. 332 Ms Earthing Rod Of 20X2500 Mm With 25X3 Mm Gi Strip 333 Aluminium Binding Wire - 6 Swg 334 Hdpe Pipe 160 Mm For Cable Riser 335 Gi Top Channel 125X65mm, 3200 Mm With Clamp, Bolts, Nuts And Washers 336 33Kv 3X 120 Mm2xlpe Cable 337 Heat Shrinkable Outdoor Type Termination Kit Suitable For 33Kv Xlpe 3X120 Sq. Mm. Cable Size 338 Straight Through Joint Boxes Suitable For H.T Xlpe Cable Of Size 120 Sq.Mm / 3C For 33 Kv 339 Hdpe Pipe For Cable Laying ( Pipe To Be Laid By Hdd Method ) ( For Road Crossing ) 340 Laying Of 3X120 Sq. Mm. 33 Kv Xlpe Insulated Cable Underground In Hdpe Pipe Or Trenches ( For Road Crossing ) 341 Drilling & Laying Of Ht Underground Cable Using Hdd Method Without Using Hdpe Pipe 342 Mounting Of Cable On Dp Structure ( Including Loop And Riser ) 343 Cable Route Marker 344 Miscellaneous Activities 345 Resagging & Tightening Of Dog / Raccon / Rabbit Conductor 346 Resagging & Tightening Of Lt Abc Cable 3X120+ 1X95 + 1X16 347 Additional Items 348 11 Kv V Cross Arm ( 100X50x6 ) Mm 349 33 Kv V Cross Arm ( 100X50x6 ) Mm 350 F-Bracket For 33 Kv 351 F Bracket For Fitting Top Insulator With Bolts & Nuts For 11 Kv 352 Complete Stay ( G.I Stay Rod 20X1800 Mm , Stay Wire7 / 8 Wire Swg 10 Kg, Stay Clamp, Bolt, Nut & Washer With Concerte Grounting ) 353 Bolts Nuts & Washers All Sizes 354 Polymeric Disc Insulator 45 Kn ( B&S ) 355 Polymeric 11 Kv Pin Insulator 356 Pg Clamp 357 Red Oxide Paint For Existing Poles 358 Aluminium Paint For Existing Poles 359 Gi Ms Channel / Ms Angle / Ms Flat Of Various Sizes For Cantilever, For Foundation, For Supports, For Structures Etc. 360 400 Kvamobile Transformer With All Cable And Fixing Arrangements For Urgent Services 361 Sitc Of Scada Compatible Rmus 362 Outdoor Type 11 Kv Sf6 Type Extensible And Motorized 5 Way Smart Ring Main Unit ( Rmu ) Complete With Three Vcb And Two Lbs Withfpi Along With Frtu & Modem ( Modem Should Be Double Sim On 4G / 5G ) And With The Provision Of Self Powered Supply Through 1 Kva Auxilliary Power Transformer 11 / 0.230 Kv As Per Nigam Specs Along With Other Allied Material Like Cable, Ternination Kits Etc.To Connect The Same With System 363 Outdoor Type 11 Kv Sf6 Type Extensible And Motorized 3 Way Smart Ring Main Unit ( Rmu ) Complete With Two Vcb And Two Lbs With Fpi Along With Frtu & Modem ( Modem Should Be Double Sim On 4G / 5G ) And With The Provision Ofself Powered Supply Through 1 Kva Auxilliary Power Transformer 11 / 0.230 Kv As Per Nigam Specs Along With Other Allied Material Like Cable, Ternination Kits Etc.To Connect The Same With System 364 Fpi 365 Communicable 366 Ug Cable From Pole Top To Rmu And From Rmu To Dts 367 Supply, Laying Of 11 Kv Xlpe, 3 C X 185 Sq.Mm Cable Insulated Ug Cable Including Provision For Proper Support To Hold The Cable At Pole Dtr End Till It Reaches The Ground Level And Laying Under Ground As Per Site Condtion For Connections Of Overhead Conductor To Rmu And As Well As From Rmu To Distribution Transformer Complete In All Respects As Per Specification 368 Control / Power Cable For Rtusfrom Outdoorswitchgear, If Any At S / S And Numericalrelays 369 Control Cable Armoured ( 1 Sq Mm For Control And Monitoring Element Wiring ) ( As Required ) With Miscellaneous Consumables Items For E.G. Connectors, Thimbles Etc ( 30 Mtr Per Dss ) 370 Control Cable Armoured ( 2.5 Sq Mm For Ct & Pt Wiring ) ( As Required ) With Miscellaneous Consumables Items For E.G. Connectors, Thimbles Etc ( 30 Mtr Per Dss ) 371 Numerical Relay 372 11 Kv Indoor Switchgear Panel Complete In All Respects As Per Speciication And Direction Of Employer / Pmc. 373 Simplex Cubicle Switchgear Panel For Transformer Incomer Complete In All Respects As Per Specification And Direction Of Employer / Pmc. 374 Simplex Cubicle Switchgear Panel For Outgoing Line Complete In All Respects As Per Specification And Direction Of Employer / Pmc. 375 Simplex Cubicle Switchgear Panel For Bus Coupler Complete In All Respects As Per Specification And Direction Of Employer / Pmc. 376 Bus Vt Pt1 And Pt2 For Measauring Panels Complete In All Respects 377 Spares 378 Simplex Control And Relay Panel For Hv Side Of 33 / 11 Kv Transformer At Taxistand Substation Complete In All Respects As Per Specification And Direction Of Employer / Pmc. 379 Auxiliary Power Supply ; Main Equipments - Control Centre 380 Ups With Suitable Rating Running In Parallel Redundant Mode* Withvrla Type Battery Banks For Above Ups For Minimum 30 Min. Backup Duration 381 For Rtu / Data Concentrator / Communication Eqpts. 382 Dc Power Supply ( Dcps ) System Based On Smps And Battery Bank For Above Dcps ( Vrla Type ) For Minimum 4 Hrs Backup 383 For Frtu 384 48V Dc Power Supply ( Dcps ) System Based On Smps Andbattery Bank For Above Dcps ( Vrla Type ) For Minimum 4 Hrs Backup 385 Spares 386 Communication System - Mpls 387 6 Core Fo Cable Including Laying As Per Nigam Specs Along With Other Allied Material Like Ties, Joint Boxes Etcto Connect The Same With System 388 Fibre Optic Teremination System Complete In All Respects As Per Nigam Specs 389 Mpls Router 390 Gprs 391 Annual Chargesfor 2Mbps Links With Frtus / Fpi For Two Years 392 Modems 393 Spares 394 Rtus 395 Rtu Base Equipment Comprising Panels, Racks, Sub-Racks, Power Supply Modules, Cpu, Interfacing Equipment, Required Converters & All Other Required Items / Accessories Including Complete Wiring For All Modules. 396 Multifunctuions Transducers 397 Contact Multiplying Relays ( Cmrs ) 398 Heavy Duty Relays For Control 399 Dummy Breaker Latching Relays 400 Transformer Transducers 401 Single Tft Pc For Ldms 402 Serial Communication Cable ( 2 Pair Armoured With Steel Conduit ) To Integrate Existing Relay Or Mfm ( 100 Mtr Per Pss ) . 403 Ethernet Cat6 Cable With Steel Conduitto Integrate Existing Relay, Bcu, Bpu & Bcpu ( 100Mtr Per Pss ) With Miscellaneous Consumables Items Like Rj 45 Connectors & Patch Code Etc. 404 Software For Ldms 405 Ldms Software 406 Test Equipments For Rtu 407 Rtu Database Configuration & Maintenance Software Tool 408 Master Station Cum Rtu Simulator & Protocol Analyser Software Tool 409 Laptop Pc For Above Software Tools Along Withinterfacing Hardware Including Hub 410 Mandatory Spare 411 Frtus 412 Mini Pole Mounted Frtu Base Equipment Along With Enclosure Suitable To Work In Open Environment ( Adequate Protection From Water & Dust ) , Racks, Sub-Racks, Power Supply Modules With Power Backup , I / O Modules, Cpu, Interfacing Equipment, Required Converters & All Other Required Items / Accessories Including Complete Wiring For All Modules 413 Contact Multiplying Relays ( Cmrs ) 414 Heavy Duty Relays For Control 415 Multifunction Trnasducer 416 Test Equipments For Frtu 417 Frtu Database Configuration & Maintenance Software Tool 418 Master Station Cum Frtu Simulator & Protocol Analyser Software Tool 419 Laptop Pc For Above Software Tools Along Withinterfacing Hardware Including Hub 420 Spares 421 Software For Control Centre 422 Scada Software 423 Isr Software 424 Dms Software 425 Dts Software 426 Developmental Software 427 Network Management Software 428 Gis Adaptor / Engine For Importing Data From Gis System Under It System 429 Backup Software - Compatible To Proposed Architecture 430 Spares 431 Scada / Dms Control Centre-Server / Workstationhardware 432 Scada Server 433 Dms Server 434 Fep Server With Interface Switches 435 Isr Server 436 Nms Server 437 Dts Server 438 Developmental Server 439 Commnuicationserver 440 Web / Directory Server 441 Sms Gaterway 442 Workstation With Dual Tft Monitors ( S / S Monitoring ) 443 Workstation With Dual Tft Monitors ( Network Monitoring ) 444 Remote Vdus With One Tft Monitors 445 Developmental Console With One Tft 446 Dts / Workstation Console Withdual Tfts 447 Dlp / Led Based Video Projection System With 3X4 Module Configuration With Each Module At Least 67 Diagonal With Common Projector 448 Storage & Backup Devices 449 External Raid Mass Storage Device ( For 24 Months Online Backup ) 450 Switches 451 Layer Ii Switch ( Scada / Dms Lan ) 452 Layer Ii Switch ( Planning & Development System Lan ) 453 Security System ( Dmz ) 454 Firewall & Network Ids / Ips 455 Layer Ii Switch 456 Other Active Devices 457 Gps Timesynchronisation System 458 Time, Day & Date Digital Displays 459 Printers 460 Color Inkjet Printer 461 B / W Laser Printer 462 Software For Control Centre 463 Facility Managament Services For 2 Years After Go-Live