Tender For Repair/Maintenance Of Summer Appliances, Including Cold Storage Of Various Capacity And Allied Other Works At Ahrr Under Ge E/M Rr Hospital Delhi Cantt-10, delhi-Delhi

Military Engineer Services-MES has published Tender For Repair/Maintenance Of Summer Appliances, Including Cold Storage Of Various Capacity And Allied Other Works At Ahrr Under Ge E/M Rr Hospital Delhi Cantt-10. Submission Date for this Tender is 14-12-2022. Air Conditioner Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

34842046
Corrigendum : Tender For Repair/Maintenance Of Summer Appliances, Including Cold Storage Of Various Capacity And Allied Other Works At Ahrr Under Ge E/M Rr Hospital Delhi Cantt-10
Open Tender
Indian
Delhi
delhi
14-12-2022

Tender Details

Tender For Repair / Maintenance Of Summer Appliances, Including Cold Storage Of Various Capacity And Allied Other Works At Ahrr Under Ge E / M Rr Hospital Delhi Cantt-10

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 07-Dec-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 14-12-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 82800.0 /-
Tender Value
INR 41.40 Lakhs /-

BOQ Items

Name of Work :-REPAIR/MAINT OF SUMMER APPLIANCES, INCLUDING COLD STORAGE OF VARIOUS CAPACITY AND ALLIED OTHER WORKSAT AHRR UNDER GE E/MR & R HOSPITAL, DELHI CANTT-10
Sl. No. Item Description
1M&L for taking down carefully window type AC of 1.5/2.0 TR capacity, any type/make, from window/wall and removing power connection and front PVC grills, air filters, cleaning, washing, removing dirt, servicing including chemical wash of cooling and condenser coil and re-assembling the dismantled components and fixing to its original position, complete all as directed.
2M&L for servicing of split type AC of 1.5/2.0 TR capacity, any type/make, at site /wall and removing power connection and front PVC grills, air filters, cleaning, washing, removing dirt, servicing including chemical wash of cooling coil of indoor cooling unit and condenser coil of out door unit and re-assembling the dismantled components and fixing to its original position complete all as directed. Note : The cost of additional inlet/outlet copper pipes, drain pipe and electrical cord, if required and making good of surface as original by plastering / whitewash / colour / distemper etc is included in quoated rate and no extra payment will be made to contractor in this effect.
3M&L for servicing of water cooler 40/80 or 60/120ltr capacity, any type/make, at site and removing power connection and drain out water, cleaning, washing, removing dirt, including re-assembling the dismantled components and fixing to its original position and testing the machine to its optimum efficiency complete all as directed. Note for Item No 01 to 03 : The servicing of item, as mentioned in ser no 1, 2 & 3, shall be repeated as and when required to improve the cooling efficiency of machine installed as per the direction of Eng-in-Charge. No extra payment shall be made in this effect.
4M&L for shifting of Split type AC of 1.5/2.0 TR capacity, any type/make, with stabilizer including taking down carefully indoor and outdoor unit, copper piping, drain pipe and thermal sleeve, lifting angle etc and installating the same to new location using copper piping of suitable gauge for suction and delivery with insulation, drain pipe and re-fixing arrangement i. e. lifting angle, fastners, nut bolt, washer etc,testing & commissioning, complete all as directed. Note : 1.The cost of making hole for passing through inlet/outlet copper pipes, drain pipe and electrical cord and making good of surface at both location as original by plastering / whitewash / colour / distemper etc is deemed to be included in quoated rate and no extra payment will be made to contractor in this effect.2. The copper piping will be measured and paid separately under respective item(s) of this Sch. 3.Gas Chargeing deemed in the quoted rate
5M&L for shifting of window type AC of 1.5/2.0 TR capacity, any type/make, with stabilizer from one location to another complete with and including making of suitable opening in brick wall or removing aluminum grill and/or glass pane from existing window, including supply and fixing of new wooden frame of suitable size and thickness for proper fixing of outer chassis of AC at new location, making good of disturbed surface as original etctesting & commissioning, complete all as directed. Note : The cost of making suitable opening in brick wall or removing aluminum grill and/or glass pane from existing window and making good of surface at both location as original by plastering / whitewash / colour / distemper etc is included in quoated rate and no extra payment will be made to contractor in this effect.Gas Charge deeed in the quoted rate.
6S&F, in replacement of copper tubing of 1/2” dia suitable for suction / discharge line of split type AC complete all as directed.
7All as per item No. 06 here-in-before but copper tubing of 3/8” dia.
8All as per item No. 06 here-in-before but copper tubing of 5/8” dia.
9All as per item No. 06 here-in-before but copper tubing of 1/4” dia.
10S&F, in replacement of hermetically sealed reciprocating typecompressor unit exchanged from authorized dealers of compressor of 1.5 TR Split type capacity complete all as directed.
11All as per item No. 10 here-in-before but 2.0 TR capacity.
12S&F, in replacement of hermetically sealed reciprocating typecompressor unit exchanged from authorized dealers of compressor suitable for water cooler of cooling capacity 40/60 Ltr, complete all as directed.
13S&F, in replacement, ofhermetically sealed rotary typecompressor of exchanged from authorized dealersofcapacity 1.5 Ton suitable for air conditioner of any make/type including replacement of foundation bolts, rubber pad etc, complete all as directed.
14All as per item No. 13 here-in-before but 2.0 TR capacity.
15M&L for Gas charging of Air Conditioner window/split type of capacity 1.5/2.0 Ton with R - 22 / R-410 or any other recommended refrigerant gas, including detect of leakage, repairing using welding/brazing, pressure tesing, replacement of connection lead, tin coated copper thimbles and installation of AC at site and testing on full load for 24 hours continuously etc complete all as directed.
16All as per item No. 15 here-in-before but for water cooler of 40/80 ltrs cooling capacity.
17M&L for detecting the leakage in refrigerant system of refrigerator of 165 to 210 ltr capacities, single phase, repairing it by welding/brazing, pressure testing at required pressure of150 PSI with charging of nitrogen gas for 24 hrs, with and including charging of refrigerant R-134A / R-22 or any other recommended refrigerant gas, complete all as directed.
18All as per item No. 17 here-in-before but for refrigerator/deep freezer of 220 ltr and above capacity.
19S&F in replacement of hermetically sealed rotary typecompressor unit suitable for refrigerator/deep freezer of 165 / 210 ltrs capacity of any make/type, medium temperature range, including replacement of foundation bolts, rubber pad, strainer, capillary tubes, suction and discharge pipe line etc, complete all as directed.
20All as per item No. 19 here-in-before but for refrigerator/deep freezer of 220 ltr and above capacity.
21S&F, in replacement of starting capacitor 80 to 100 mfd, 240 volt including making connection etc, complete all as directed.
22All as per item No. 21 here-in-before but for starting capacitor 120 mfd and above capacity.
23S&F in replacement running capacitor 36 mfd 440 volt all as specified.
24All as per srl item No23 here in above but 10 mfd 440 volt all as specified.
25All as srl item No 23 here in before but multi capacitor of 50 mfd + 6 mfdport.
26All as srl item No 23 here in before but of 50 mfd .
27All as srl item No 23 here in before but of 60 mfd.
28S&F, in replacement, of thermostate switch of temperature range of 18°C to 30°C, ISI Marked suitable for air conditioner of any make / type / capacity including making connection etc all as completespecified and directed by .
29Taking down fan blower motor from window air conditioner of any make/type but 1.5 Ton capacity and replacing with the new motor of same rating, with copper winding, single phase, 200/230 volt, 50 Hz, in the same position, testing etc complete all as directed. Note-during the replaced new mortor required new fan deemed in the quoted rate.
30All as srl item No 29 here in before but for AC of 2.0 TR capacity.
31S&F, in replacement of starting relay, ISI Marked suitable for air conditioner of any make / type / capacity including making connection etc, complete all as directed.
32Supply only in replacement of Temp. and humidity controller data logger with memory for 32700 readings LCD type free selectable measurement cycle from 1 sec to 24 hrs, temp. range -40 degree centigrade to 70 degree centigrade and humidity range 0 to 100% RH.
33M&L in replacement of digitalmultipurpose progrrammable timerTM619for walk in cold room of automization as per specified.
34S&F in replacement of temperature control relay with digital display ranging from 0 to 50°C for cooling purpose, complete all as directed.
35S&F, in replacement, of indoor cooling unit suitable for split type AC of 1.5 TR capacity including making connection etc, complete all as directed.
36All as srl item No 35 here in before but for AC of 2.0 TR capacity.
37S&F, in replacement, of split AC out door unit Kit of 1.5 TR capacity, company made, consist of metal sheet enclosure, condenser coil, wiring kit ,compressor,condenser fan motor, condenser fan and blower, PCB etc siutable for1.5 Ton split AC of any / make, complete all as directed.
38All as srl item No 37 here in before but for AC of 2.0 TR capacity.
39S&F, in replacement of new fan motor ISI marked with cooper winding, in existing water cooler of any make/type/capacity including all fixing accessories etc complete all as directed.
40S&F, in replacement of new fan motor blade ISI marked metalic type in existing water cooler of any make/type/capacity including all fixing accessories etc complete all as directed.
41M&L for MS work, fabricated from MS channel, angle iron, flat iron of any size duly welded, including drilling of holes of suitable size with and including nuts, bolts and washers etc, as required and fixing the same on any level of the building, including painting with two coats of synthetic enamel paint over a coat of red oxide paint complete all as directed.
42S&F of PVC pipe, medium grade of size 20mm with and including all fitting i. e. elbow, bend, Tee, etc suitable to connect Window/split type AC drain line to nearby rain water pipe or any other pipe and to be fixed on wall or floor upto 5 level of the hospital building with necessary clamping arrangement, complete all as directed.
43S&F, in replacement of GI tray suitable for window AC drain water, made of MS sheet duly painted with two coat of synthetic enamel paint over one coat of red oxide primer, having neccesary fixing arrangement to fix with window AC of any type/capacity and MS pipe of 10 mm dia & minimum 3 feet long connected to down side of tray, complete all as directed.
44Supply, fixing and connecting of chromium plated push cook tape, in existing water cooler of any make/type/capacity including all fixing accessories etc complete all as directed.
45Supply and fix PVC push coock tape ISI markedin exting water cooler of any make /type /capacity all as directed and spacified by Engr-in-Charge
46S&F in replacement flexible foam type insulation suitable for insulating the suction and discharge line of split AC all as specified.
47S&F, in replacement, of electronic control circuit card i. e. PCB suitable for air conditioner of any make/type but 1.5 / 2.0 ton capacity including making connection etc, complete all as directed.
48S&F, in replacement of MCB, C Curve type, 10 kA, 10 to 32 Amp, Single Pole with over load and short circuit protection complete all as directed.
49S&F, in replacement of starting relay, ISI Marked suitable for water cooler of any make/type/capacity including making connection etc, complete all as directed.
50S&F, in replacement of Voltage stabiliser, copper wound of 5 KVA capacity digital display type having I/P Correction Range of 130 - 280 volt, complete all as directed.
51All as per srl item No. 50 here-in-before but of 4 KVA capacity.
52S&F of factory made wall mounted/floor mounted type AC outdoor unit stand of superior quality duly powder coated, suitable for AC of 1.5/2.0 TR capacity complete all as directed.
53S&F, in replacement of fan blower motor suitable for split type AC, in door unit of capacity 1.5 TR /2 TR all as specified.
54S&F, in replacement of fan blower motor suitable for split type AC, out door unit of capacity 1.5 TR /2 TR all as specified.
55S&F blower for split AC of indoor unit any type any description /any make /any type suitable for 1.5 TR or 2.0 TR capacity allasspecified and directed by Engr-in-Charge.
56S&F, in replacement of thermostat switch with knob ISI marked suitable for water cooler of any make/type/capacity including making connection etc, complete all as directed.
57S&F in replacement of desert cooler of 18" body made of PGI sheet of 22 SWG complete with side panels, front panel, side arms, water tank, distributor, elbow, PVC pipe 15mm dia, front grill made of PGI sheet 26 SWG etc with and including taking down of old fan kit & water pump motor from old unserviceable desert cooler and refixing the same in new desert cooler body including making all electrical connections & testing, including two coat of approved synthetic paint over a applying one code of red oxide primer complete all as directed.
58All as per srl item No 57 here-in-above but desert cooler of 20" body made of PGI sheet of 22 SWG.
59M&L for removing the desert cooler from site and re-fixing after necessary repair/overhauling with and including cleaning and scratching of old paint and rust by wire brush, emery paper etc and applying two coats of synthetic enameled spray paint of off-white / gray colour over one coat of primer (red oxide) with and including black bitumen paint at inside of the bottom part of desert cooler body complete, including oiling and greasing of fan kit / exhaust fan, water pump motor with and including replacement of unserviceable worn out nuts, bolts and washers etc, complete all as directed.
60S&F in replacement of new fan motorsingle phase, 90 watt, 230 volt, AC 50 Hz copper wounded three speed with fan blade suitable for desert cooler of 500 mm sweep size etc with and including making all electrical connections & testing,complete all as directed.
61S&F in replacement of new exhaust fan motor, heavy duty type, single phase, 230 volt, AC 50 Hz copper wounded suitable for 18/20/22 inch desert cooler etc with fan blade ncluding making all electrical connections & testing,complete all as directed.
62M&L in replacement of plastic body submersible pump, 45 watt, 230 volt, AC 50 Hz, single phase, ISI marked suitable for desert cooler with and including taking down of old unserviceable pump and making all electrical connections & testing, complete all as directed.
63S&F in replacement of wood wool grass pad dulybraced with GI wire mesh suitable for 18/20 inch desert cooler panel shutters with minimum weight not less than 1.5 Kg, complete all as directed.
64S&F in replacement of PVC pipe of 15 mm dia size, complete all as directed.
65S&F in replacement of PVC insulated, PVC sheathed flexible cable, single core, 1 sqmm size, stranded copper conductor, 1100 volts grade, complete all as directed.
66S&F connection lead for desert cooler of size 1.5 Sq mm three core 1.5 Mtr long allas directed and specified by Engr-in-Charge .
67S&F in replacement of plug top 16 Amp, three pin, 240 volts, AC, complete all as directed.
68S&F in replacement of plug top 05 Amp, three pin, 240 volts, AC, complete all as directed.
69S&F in replacement of speed selector rotary type switch 5 Amp, 230 Volt, AC, ISI marked, complete all as directed.
70S&F in replacement of PVC water distributor 3 way suitable for desert cooler, complete all as directed.
71S&F in replacement of PVC water elbow 15 mm dia size suitable for desert cooler, complete all as directed.
72S&F in replacement of running capacitor of 4.0 mfd 230 Volt, 50 Hz AC suitable for fan motor complete all as directed.
73All as srl item No 72 here in before but of 6.0 mfd.
74S&F in replacement of PVC float valve of 15mm bore size suitable for water cooler water tank and desert cooler with and including one number socket/reducer, complete all as directed.
75M&L for servicing/overhauling of walk in cooler (cold storage) of upto 2.0 TR capacity with and including removal of power connection, front PVC grills, air filters etc, removing dirt, cleaning/washing of cooling coil, condenser coil, chemical wash of cooling coil of indoor unit & condenser coil of out door unit and re-assembling/refixing of all dismantled components to its original position and testing upto to the entire satisfaction of Engr-in-Charge, complete all as directed. Note : The entire servicing process shall be guaranteed for entire contract period and the same must be repeated as and when required to improve the cooling efficiency of machine and no extra payment shall be made for repeated process.
76M&L for detecting the leakage in refrigerant system of cold storage / walk-in-cooler / morchury cabinet of capacity upto 20 TR capacity, Single/three phase, repairing it by welding/brazing, pressure testing at pressure of80 PSIG with charging of nitrogen gas for 24 hrs, with and including charging of refrigerant R-134A/R-22, complete all as directed.
77S&F replacement of hermetically sealed reciprocating type reconditioned compressor unit exchanged from authorized dealers of compressor of 2.5 TR capacity, three phase, 440 volt, with and including charging of recommended refrigerant gas, complete all as directed.
78S&F in replacement of hand shut valve, brass body of size 5/8,1/4,3/4inches, complete all as directed.
79S&F in replacement of thermostat expansion valve 3/8 or ½inch size of existing shape and size, complete all as directed.
80S&F in replacement of contactor with relay assembly of capacity 0-15 Amperes suitable for cold storages, complete all as directed.
81S&F in replacement of fan assembly (AXIAL) of 12 inch size, incl electric motor of suitable capacity single phase, 230 volt, 50 Hz AC with and including bracket & fixing arrangement suitable for cooling coil of cold storage, complete all as directed.
82S&F in replacement of refrigerant drier suitable for cold store of capacity 1.5/2/3/4 TR, complete all as directed.
83S&F in replacement of condenser / evaporator coil suitable for refrigerator of 165/210/310 Ltr capacity of any make/type, complete all as directed.
84S&F in replacement of refrigerant copper dryer filter with capillary tube suitable for refrigerator of 165/210/310 Ltr capacity of any make/type, complete all as directed.
85S&F in replacement of magnet type door gasket suitable for refrigerator of any make/type/capacity including making connection, complete all as directed.
86S&F, in replacement of MCB protected modular AC/Geyser box complete with and including 6 pin socket, plug top, modular cover plate, mini MCB SP 25 Amp capacity and PVC gang box etc, complete all as directed.
87S&F, in replacement, of indoor with coolingcoil, blower moter,blower with PVC accessories for coldroom 24000 BTU capacity including making connection etc, complete all as directed.
88S&F, in replacement, ofcooling unit suitable for walking cooler/Cold storagecapacity2 TRor 24000 BTUincluding making connection etc, complete all as directed.
89S&F, in replacement, ofCondense coil suitable for walking cooler/Cold storagecapacity2TR or 24000 BTU including making connection etc, complete all as directed.
90S&F Extial fan for walking cooler /cold strage type 300/400 mm sweep working with 230 Volt 50 hz suitable for coldstorage and taking down exinting one all as directed by Engr-in-Charge .
91M&L formodification of electronic control circuit card i. e. PCB suitable for Spilit type AC capacity 1.5TR/2 TR or window type Acs!.5 TR/ 2 TR including making connection etc, complete all as directed.
92S&F, in replacement, of electronic control circuit card i. e. PCB suitable for walking cooler /Cold strage2 TR to10 TR capacity including making connection etc, complete all as directed.
93S&F in replacement of condenser / evaporator coil suitable of capacity 1.5 TR/2 TRwondow type AC , complete all as directed.
94S&F in replacement of cooingcoil suitable of capacity 1.5 TR/2 TRwondow type AC , complete all as directed.
95M&L for Gas charging of TowerAir Conditionerof capacity 2.0 /3.5TR/3.8 TR/4TR Ton with R - 22 / R-410 or any other recommended refrigerant gas, including detect of leakage, repairing using welding/brazing, pressure tesing, replacement of connection lead, tin coated copper thimbles and installation of AC at site and testing on full load for 24 hours continuously etc complete all as directed.
96M&L for detecting the leakage in refrigerant system of Tower AC ofcapacities2.0 /3.5TR/3.8 TR/4TR, single phase, repairing it by welding/brazing, pressure testing at required pressure of150 PSI with charging of nitrogen gas for 24 hrs, with and including charging of refrigerant R-134A / R-22 /R410 or any other recommended refrigerant gas, complete all as directed.
97S&F , replacement of reverse Valve of split type Ac 1.5 TR/2TR and window ty AC capacity 1.5 TR /2 TR with our door valve and PCB modificationincluding welding/brazing, pressuretesting with N2 Gas and electric connection (if extra copper wire required any description deemed in the quoted rate) all as directed by Engr-in-Charge.
98Supply only remote suitablefor Window type AC / Split type AC as per existing make /type /capacity (1.5 TR/2 TR) all as directedand specifiedby Engr -in -Charge
99S&F Single phase contactorwith wide bandcoil andchatter free operation band working voltage 160 Volt to 240 Volt 50 Hz 40 Amps Capacity all as specified and directed by Engr-in-Charge .
100S & F PVC desert cooler fan blade suitable for 18/20 /30 hight desert cooler exsting reccommended size all as specified and directed by Engr-in-Charge
101S&F Aluminum Frezer suitable refrigerator of capacity 165 ltrup to 310 ltr including all connection ,welding,brazing and filling and dismentling existing one complete all as directed by Engr-in-Charge.
102M & L for Air curtain serviceing including taking down existing air curtain ,cleaning ,removing dust,greasing the bearing ,welding, if required the new bearing should be replaced as per site requirment ,fasten nut and bolt etc,after serviceing refix the same position , all as directed by Engr-in-Charge.
103M&L for Air curtainmotorwinding with suitable gauge of copper wire as per existing motor speedincluding polishing ,burnishing ,change the old bearing ,and refixing inexisting positionall as directed and specified by Engr-in-Charge.
104S&F Air curtain New motor as per esixting sample ,speed ,voltage and Amps includingdismentling existing one complete all as directed and specified by Engr-in-Charge.
105S&F Air curtain New blower as per esixting sample ,speed ,sape and size includingdismentling existing one complete all as directed and specified by Engr-in-Charge.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail