| Sl. No. | Item Description |
| 1 | Taking down carefully (copper/aluminum) point wiring complete of any type (batten/surface conduit) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants regulators etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster or tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed. |
| 2 | Material and Labour for point wiring complete using 1.5 Sqmm PVC insulated unsheathed copper conductor, stranded cable (FRLS) upto and including working voltage 1100volts grade, drawn through and including PVC casing and caping including all accessories ISI marked including press fit white PVC open switch/surface board high strength and crack resistance and unsheathed copper conductor stranded cable(FRLS) earth continuity wire connected to DBs/sunken boxes/fittings of size 1.5 Sqmm Cross sectional area and all other metal parts with earth dolly for the following:-. |
| 3 | (a ) onelight point controlled by one switch 5 Amps |
| 4 | (b ) onefan pointpoint controlled by one switch 5 Amps |
| 5 | (c) One 3pin socket outlet 5 Ampson Independent board |
| 6 | (d ) One 3pin socket outlet 5 Ampsonsame board |
| 7 | ( e) One bell pointcontrolled by one bell push |
| 8 | All as per Item No. 2 above but with 4 sq mm PVC insulated copper conductor cable(FRLS) including 4 sq mmPVC copper conductor used as earth wirefor power point on independent board for One 3 pin socket outlet, 15 Amps. |
| 9 | Supply and fix Switch piano Flush, single pole, one way 5 amp 230 Volts, AC, with ISI mark complete all as specified and directed. |
| 10 | Supply and fix SwitchSocket Combination 2 in 1, 5 Amps flush type 230 Volts, AC, with ISI mark complete all as specified and directed. |
| 11 | Supply and fix SwitchSocket Combination2 in 1, 5 Amps /16 Ampsflushtype230 Volts, AC, with ISI mark complete all as specified and directed. |
| 12 | Supply and fix Socket outlet 2 in 1, 5 Amps flushtype230 Volts, AC, with ISI mark complete all as specified and directed. |
| 13 | Supply and fix Bell electric Ding Dong 230 Volts, AC, with ISI mark complete all as specified and directed. |
| 14 | Attending internal/ external electric complaint for maintenance/breakdown, round the clock for maintenance, checking, fault finding and rectification of fault in LT panels/Overhead HT/LT lines, transformers, switchgears and carry out repairs and resume electric supply complete all as specified and directed by Engineer-in-charge.Note:- (a)Day to day complaint rectified by the Electrician shall be written in complaint register and completion report recorded in complaint register and complaint document slip rectified complaints only will be paid.(b) The spares required for the rectification of fault shall be measured under items 10 to 36, 51 to 58.(c) Five(05) numbers of complaint shall be measured as one unit(Each Job) |
| 15 | Supply only Switch piano Flush, single pole, one way 5 amp complete all as specified and directed. |
| 16 | Supply only of SwitchSocket Combination 2 in 1, 5 Amps flush type complete all as specified and directed. |
| 17 | Supply only modular Socket outlet2 in 1, 6 Amps /16 AmpsflushtypeComplete all as specified and directed. |
| 18 | Supply only Bell electric ding dong 230 V complete all as specified and directed. |
| 19 | Supply only Bell push 5 Amps one way complete all as specified and directed. |
| 20 | Supply only Electronicfan regulator 230 volts, step type,socket type, hum free 120 watt ISI Marked complete all as specified and directed. |
| 21 | Supply onlyCeiling rose in poly carbonate 3 plates flush type 6 Amps, 230 volts AC complete all as specified and directed. |
| 22 | Supply only Lamp holders baklite body with back plate suitable for battern fitting/angle fittingcomplete all as specified and directed. |
| 23 | Supply only of Modular switch, one way, 6Amps complete all as specified and directed. |
| 24 | Supply only Modular switch, one way, 16Amps complete all as specified and directed. |
| 25 | Supply only Modular switch, two way, 6 Amps complete all as specified and directed. |
| 26 | Supply only Modular socket outlet, 6 Amps, 2 and 3 pin combined complete all as specified and directed. |
| 27 | Supply only Modular socket outlet, 6 Amps/ 16 Amps, 2 and 3 pin combined complete all as specified and directed. |
| 28 | Supply only Modular fan regulator step type, 120 Watt complete all as specified and directed. |
| 29 | Supply only Modular Bell push, 6 Amps complete all as specified and directed. |
| 30 | Supply only Modular switch socket combination 16 A 6 pin complete all as specified and directed. |
| 31 | Supply only Condenser 2.5 Mfd AC 240V, complete all as specified and directed.Make: Cat No QHPCWC5002X5 of Havells or equivalent in L&T/Surya |
| 32 | Supply only Condenser 4 Mfd AC 240V, complete all as specified and directed.Make: Cat No QHPCWC5004X0 of Havells or equivalent in L&T/Surya |
| 33 | Supply only LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.Make: Havells Cat part No. ENDURALINEARNEOBS20WLED865SPCSS or equivalent in Philips/Bajaj/Surya. |
| 34 | Supply only in repairs LED bulb 9 watts, 230 volt complete all as specified and directed. Make:Havells Cat part No NU BULB PLUS 9 W 865 B22 3 STAR LHLDEUECNL8R009 or equivalent in Philips/Bajaj/Surya. |
| 35 | Supply only LED luminaire 600 mm x 600 mm,40 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.Make: Havells Cat part No. PLANO2X2PLR42WLED840S or equivalent in Philips/Bajaj/Surya. |
| 36 | Supply only LED light fitting mirror type with high out put diffuser 2 feet,10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make: Havells Cat part No. ENDURALINEARNEOBS10WLED865SPCSS or equivalent in Philips/Bajaj/Surya. |
| 37 | Supply and fixing in repair/replacement energy efficient LED building security light fitting 35W on existing brackets including connection with twin core flexible pvc 0.5 sqmm cable complete all as specified and as directed.Make: Havells Cat part No. ENDURASUNDOWNSL35WLED765PASYBOPC or equivalent in Philips/Bajaj/Surya. |
| 38 | Supply and fix in repairs single pole and neutral enclouser with a two pin and earth plug and socket complete with one MCB single pole 20 Amps complete all as specified and directed. |
| 39 | Supply only MCB SP 6-32 amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of single pole in the MCB DB,IP 20 transparent lebel holder fully insulated safety shutters suitable for cable up to 35 Sqmm cross sectional area complete including suitable size copper Lugs complete all as specified and directed. |
| 40 | Supply only MCB SPN 63 amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of single pole in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 41 | Supply only TPN 100 AMP, 415V 10KA \"C\" curve miniature circuit breaker (MCB) in the DB complete with connection testing and commissioning all as specified and directed. |
| 42 | Supply and fix in repairs Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, SPN 2 way with 200 Amps rated copper bus bar double doorprotection, neutral bar,earth bar, single pole and neutral 240 volts, MCBs used as incommer flush to wall complete all as specified and as directed. |
| 43 | All as per ser item No 37 here-in-before but SPN 4 way, double door 240 volts. |
| 44 | All as per ser item No 37 here-in-before but SPN 8 way, double door 240 volts |
| 45 | Supply and fix in repairs Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, TPN 4 way with 200 Amps rated copper bus bar double doorprotection, neutral bar,earth bar, triple pole and neutral 415 volts,MCBs used as incommer Double door, flush to wall complete all as specified and as directed. |
| 46 | Material and labour for Sub main wiring using two single corePVC insulated cable(FR) 4 sqmm copper conductor multi stranded and 4 sqmm copper conductor insulated cable (FR)using as earth wire drawn through and including suitable size PVC Casing and Caping including taking down old aluminium/CopperSub main wirng complete all as specified and directed. Note- 3 run of 4 sqmm PVC copper wire and One run of PVC casing capingshall be measured and paid as oneunit. |
| 47 | Material and labour for Sub main wiring using two single corePVC insulated cable (FR) 6 sqmm copper conductor multi stranded and 6 sqmm copper conductor insulated cable (FR)using as earth wire drawn through and including suitable size PVC Casing and Caping including taking down old aluminium/CopperSub main wirng complete all as specified and directed. Note-3 run of 6 sqmm PVC copper wire and One run of PVC casing caping shall be measured and paid as oneunit. |
| 48 | Material and labour for Sub main wiring using four single corePVC insulated cable(FR) 6 sqmm copper conductor multi stranded and two runs of 6 sqmm copper conductor insulated cable (FR)using as earth wire drawn through and including PVC conduit pipe ISI marked of size 25 sq mm including taking down old aluminium/CopperSub main wirng complete all as specified and directed. Note-6 run of 6 sqmm PVC copper wire and One run of PVC conduit shall be measured and paid as oneunit. |
| 49 | Taking down ceiling fan of any type and size, cable ends, dimantling blades and removing fan and balde to store yard and Hanging/fixing only repaired/reconditioned Fan of any type and size and connecting up including provision of cable from ceiling rose or connector to fan all as specified and directed. |
| 50 | Collection of unserviceable ceiling fan 1200mm/1400mm sweep 230V, AC single phase from store yard of AGE E/M and transporting to local market, cutting unserviceable winding from fan state & rewinding same with super enamelled copper winding wire of existing gauge size including throughly cleaning all the components, oiling greasing & replacement of rusted unserviceable screws, hanging clamps with rubber reel, canopy condensers, bush, bearing & flexible copper connection wire etc complete all as directed.Note : Hanging clamps, canopy, condenser and flexible copper connection wire, painting, down rod, bearing, bush, clamps shall be measured & paid separatetly. |
| 51 | All as per item No 45 here-in-before but exhaust fan 300 mm sweep |
| 52 | All as per item No 45 here-in-before but exhaust fan 350 mm sweep |
| 53 | All as per item No 45 here-in-before but exhaust fan 450 mm sweep |
| 54 | All as per item No 45 here-in-before butWall fan 450 mm sweep |
| 55 | Material and labour for Scraping down old paint of ceiling fan of any size sweep complete body & blade including down rod filling the cavitieswith filler and making smooth surfaceby applying two coats of synthetic enamel paint over a coat of primer after prepation with sand paperby means spray gun/brush withall as specified and as directed. |
| 56 | Material and labour for Scraping down old paint of Exahust fan of any size sweep complete body & blade including down rod filling the cavitieswith filler and making smooth surfaceby applying two coats of synthetic enamel paint over a coat of primer after prepation with sand paperby means spray gun/brush withall as specified and as directed. |
| 57 | M&L forlathe work for proper filling/fixing of bearing/bushes in the top cover of the fan by filling a layer of matter after blazing & bottom cover of fan complete all as specified and directed. |
| 58 | Supply only only Ball bearing Ser No 6201 or 6202 complete all as specified and directed. Make : MDS/SKF/NBL |
| 59 | Supply only Ball bearing Ser No 6203/6204 complete all as specified and directed. Make : MDS/SKF/NBL or as per existing specifications as per sample |
| 60 | Supply only Gun metal bush for ceiling fan complete all as specified and directed. |
| 61 | Supply only Shackle type rubber reel,\"U\" clamps, bolts,split pin & washer complete all as specified and directed. |
| 62 | Supply only Canopy top/bottom suitable for 20 mm dia rod complete all as specified and directed. |
| 63 | Supply only Down rod 300 mm long of size 20 mm dia ISI marked complete all as specified and directed. |
| 64 | Supply only Fan blades suitable for 1200 mm sweep fan make & type as directed by Engr-in-Charge. |
| 65 | Supply only 1.2mm thick mild steel top/bottom cover for ceiling fan any size and make as directed by Engr-in-Charge. |
| 66 | Supply and fixing Exhaust fan blade of 300 mm sweep complete as per sample of the following sizes as directed by Engr-in-Charge. |
| 67 | All as per item No 61 here-in-before butfor 350 mmsweep |
| 68 | All as per item No 61 here-in-before butfor 450 mmsweep |
| 69 | Supply and fixing Wall mounting fan blade 450 mm sweep and make suitable for fixing and as per sampleof existingfancomplete all as specified and directed . |
| 70 | Supply and fixing Exhaust fan clamps including frame and louvers with ruber bush, etc suitbale for 300 mm sweep complete as per sample as directed by Engr-in-Charge. |
| 71 | All as per item No 65 here-in-before but for 350 mmsweep. |
| 72 | Supply and fixing Oscillating mechanism suitable for wall mounting fan any make and typeall as directed by Engineer-in-charge. |
| 73 | Supply and fixing in replacement of Exhaust fan Motor of 300 mm sweep complete as per sample of the following sizes as directed by Engr-in-Charge. |
| 74 | All as per item No 68 here-in-before butfor Exhaust fan 450 mm sweep |
| 75 | All as per item No 68 here-in-before but for wall fan 450 mm sweep |
| 76 | Taking down geyser carefully of any make and capacity 25/50ltrs, dismantlingthe geyser for inspection, cleaning of tank, repalcement of defectivepart such as heating element, thermostat switch, spacer ring, safety plug, glass wool, neon lamp, head assembly, rubber gasket, top and bottom cover, inspection plate, copper cable 3 core, 3 pin Top plug, element holding clamp, welding of studs for head assembly, defective inner and outer shell reassembling the geysers with one coat of milky white enameled, spray paint of approved quality after cleaning of all dust rust etc and writingof MES No on the geyser using black paint, Reinstallation of geysers to its original postion complete all as specified.Note :Supply only Spare parts such as heating element thermostat switch, spacer ring, heon lamp, head assembly, glass wool, safety plug rubber, gasket, copper cable, top & bottom cover, inspection plate, CP & PVC connection, Plug Top, Outer & Inner shell element holding clamps etc shall be measured & paid for seperately in respective items here in after. |
| 77 | Supply and fixing heating element any type (i.e; Cup,thread or triangular) 1.5 KW,220/230 volts ISI marked. |
| 78 | Supply and fixing heating element any type (i.e; Cup,thread or triangular) 2.0 KW,220/230 volts ISI marked. |
| 79 | Supply and fixing Thermostat ISI marked complete all as specified and directed by Engr-in-Charge. |
| 80 | Supply and fixingHead Assy \"Brass\" 8 to 9 holes suitable for 25 ltrs capacity all as directed by Engineer-in-charge. |
| 81 | Supply and fixing Safety plug \"brass\" ISI marked suitable for 25/50 ltrs geyers |
| 82 | Supply and fixingHot and cold water connection made of brass pipe,chrumium plated upto 18\" length complete with rubber washer & brass nuts, ISI marked all as directed by Engineer-in-charge. |
| 83 | Supply and fixing geyser inner assembly of brass with inlet/outlet & over flow provision rubber washer suitable for 25 ltrs capacity all as specified and directed by Engr-in-Charge. |
| 84 | Supply and fixing bottom cover plate in two halves with self toppiry suitable and as per sample complete all as specified & directed by Engr-in-Charge. Make :Bajaj, Peeco, Recold/DITZ |
| 85 | Supply and fixing phase indicator red colour circular/rectangular shape as suitable and as per sample complete all as specified anddirected by Engr-in-Charge. |
| 86 | Supply and fixing non return brass valve of 15mm bore, ISI marked as specified and directed by Engr-in-Charge. |
| 87 | Supply and fixing pressure release brass valve of 15mm bore ISI marked all as specified and directed by Engr-in-Charge. |
| 88 | Supply and fixing PVC connection wire woven with nickel plated brass adopter, both side threaded 45cm long the to suitable size of geysers complete all as specified and directed by Engr-in-Charge |
| 89 | Supply and fixing Plug top 3 Pin 16 Amps 230 volts all asspecified and directed by Engr-in-Charge. |
| 90 | M&L for servicing incl cleaning of condensor & eveporator coils fins with mild detergent and descaling of condensor coil forsplittype AC ofanymake/ capacity aftertaking down the whole unit and refixingat the existing locationor any other new location after servicing allas specified and directed by Engr- in- Charge .(Note: S&F spare parts will be measured and paid separately under relevant item.) |
| 91 | M&L for Shifting ofsplit type AC from MES yard / existing locationto the new locationby takingit afterpumping filling theopening of old locationwith cement mortor, applying white wash on wall withmatching with existing colour of the site and making opening holes on brick wall at new locationand gap well finishwith cement mortor, applying white wash, colour wash, distemper etc on wall tomatch with existing colour of the adjacent surface , installation and commissioningwith replacement of insulationof suction& discharge line. |
| 92 | M&L for Shifting of water cooler electric driven single phase having any make and capacity from MES yard/existing location by taking it after disconnectionof electric and water line and refixing the same in any other new locationincl water and electric reconnection complete all as specified and as directed. |
| 93 | Supply and fix in replacement of Printed Circuit Board suitable for 2TR CapacitySplit Unit Air Conditioners including remote, etc. Make LG/equivalent as approved by GE |
| 94 | Supply and fix in replacement of Printed Circuit Board suitable for 1.5TR CapacitySplit Unit Air Conditioners including remote, etc. all as specified and as directed. Make LG/equivalent as approved by GE. |
| 95 | M&L for Disconnecting, dismantling and taking out existing burnt out compressor fromwindow/Split type Air conditioner 2 TR Capacity and supply and fixing sealed unit compresser of existing capacity 2 TR, single phase, 230 V AC supply initialy filledwith compressor oil as speciifed by Engr-in-charge and testing on load for 24 hrs in summer. |
| 96 | Disconnecting, dismantling and taking out existing burnt out compressor fromwindow/Split type Air conditioner 1.5 TR Capacity and supply and fixing sealed unit compresser of existing capacity 1.5 TR, single phase, 230 V AC supply initialy filledwith compressor oil as speciifed by Engr-in-charge and testing on load for 24 hrs in summer. Make : LG/ Voltas/ Samsung complete all as specified and directed. |
| 97 | M&L for Disconnecting, dismantling and taking out existing burnt out compressor from water cooler of capacity 40to 80 Ltr per Hour singlephase 230 volts and supply and fixing compressor unit of water cooler of capacity 40 to 60 ltrs as speciifed by Engr-in-charge.Make :LG/ Voltas/ Samsung complete all as specified and directed. |
| 98 | Supply and fix in replacement ofAC blower fan motor for ACsuitable for 2 TR AC suitable operate on 230 Volt AC supply at 50 HZ. |
| 99 | Supply and fix in replacement ofblower fan motor water cooler capacity 40/80 suitable operate on 230 Volt AC supply at 50 HZ. |
| 100 | Supply and fix in replacement ofCapacitor 45 MFD complete all as specified and as directed.Make : Cat Part No QHLIDC545006 in Havells or equivalent in L&T/Surya |
| 101 | Supply and fix in replacement ofCapacitor 50 MFD complete all as specified and as directed.Make : Cat Part No QHLIDC550006 in Havells or equivalent in L&T/Surya |
| 102 | Supply and fix in replacement of Thermostat switch for water cooler/Window AC complete all as specified and as directed. |
| 103 | Supply and fix in replacement of Drier stainer filter suitable for AC/Water cooler/Refrigertor complete all as specified and as directed. |
| 104 | Supply and fix of insulationNytrile foam insulation suitable for 5/8 inch copper tube as per site requirement of approved makeall as specified and directed . |
| 105 | Supply and fix of insulationNytrile foam insulation suitable for 1/4 inch copper tube as per site requirement of approved makeall as specified and directed . |
| 106 | Supply and fix in replacement of Copper tube5/8 inch size as per site requirement of approved makeall as specified and as directed. |
| 107 | Supply and fix in replacement of Copper tube 1/4 inch size of approved makeall as specifiedand directed . |
| 108 | Supply and fix in replacement of Evaporator unit (indoor unit ) complete suitable for 1.5TRCapacity Split type Air Conditioners all as specified and as directed. Make : LG/ Voltas/Goderj |
| 109 | Supply and fix in replacement of Evaporator unit (indoor unit ) complete suitable for 2 TRCapacity Split type Air Conditioners all as specified and as directed. Make : LG/ Voltas/Goderj |
| 110 | Supply and fix in replacement ofCondensing (Out door) unit complete including compressor, etc. Suitable for 1.5TRCapcity Air conditioners all as specified and as directed. Make : LG/Voltas/Goderj/Total line/Techmesh |
| 111 | Supply and fix in replacement ofCondensing (Out door) unit complete including compressor, etc. Suitable for 2 TR/1.5TRCapacity Air conditioners Make : LG/Voltas/Goderj/Total line/Techmesh |
| 112 | Supply and fix in replacement of repair Bracket stand suitable for 2 TR Capacity Split type AC including Fastners, etc. all as specified and as directed. |
| 113 | Supply and chargingR-22 gas to maintain the required cooling effect as and when required in the split AC/ window type AC & other cooling appliances(charging cost incl in this item) all as specified and as directed. |
| 114 | Supply and chargingR-134 gas to maintain the required cooling effect as and when required in the water cooler, Refrigerator and other cooling applinces incl. (charging cost incl in this item) all as specified and as directed. |
| 115 | Excavation in trenches in soft/loose soil not exceeding 1.5 mtrwide and not exceeding 1.5 meter in depth for taking out and laying UG cable and getting out, excavated earth, forming bottomsurfaces to required level complete all as specified and directed. |
| 116 | Returning,filling in, including spreading, leveling, watering and well raming in layers not exc 25 cm. all as specified and as directed. |
| 117 | Removing excavated soil and depositing to the sides and returning filling in including spreading leveling watering and well ramming in layers n.exc 25cm thick in soft/loose soil after cable is laid complete all as specified. |
| 118 | M&L for providing dry screened river sand as in sand cushioning to under groundcable including punning down of sand by layer complete all as specified and as directed. NOTE: Punned thickness shall be measured and paid. |
| 119 | Supply and lay unreinforced precast cable cover size 250X150X40 mm LV1 complete all as specified and as directed. |
| 120 | Supply, laying or passing through pipe LT, XLPE insulated, galvanised steel stripor wire armoured electric power cable (heavy duty) with stranded aluminium conductor 1100 Volts grade of size 95 Sqmm 3.5 core including connecting/testing after taking out from trenches/ pole unserviceable LT UG cable complete all as specified and directed. |
| 121 | All as per item No 115 here-in-before but of size 25 Sqmm 3.5 core. |
| 122 | All as per item No 115 here-in-before but of size 16 Sqmm 4 core. |
| 123 | Supply & Fix 40 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc including clamps, nut, bolt and washers etc after taking out unserviceable pipe complete all as specified and directed. |
| 124 | All as per item Serial No 118 here-in-before but for 80 mm dia pipe. |
| 125 | Supply & Fix in replacement of MCCB 63 Amps,4 pole, 415 Volt adjustable type with breaking capacity 16 KA, Ics=100%Icu, fixed properly at directed location and connecting/testing complete all as specified and directed. |
| 126 | All as per item No 120 here-in-before but of MCCB 100 Amps |
| 127 | Supply & Fix in replacement of MCCB 125 Amps,4 pole, 415 Volt adjustable type with breaking capacity 25 KA, Ics=100%Icu, fixed properly at directed location and connecting/testing complete all as specified and directed. |
| 128 | Supply & Fix in replacement of MCCB 160 Amps,4 pole, 415 Volt adjustable type with breaking capacity 36 KA, Ics=100%Icu, fixed properly at directed location and connecting/testing complete all as specified and directed. |
| 129 | All as per item No 123 here-in-before but of MCCB 200 Amps |
| 130 | All as per item No 123 here-in-before but of MCCB 250 Amps |
| 131 | All as per item No 123 here-in-before but of MCCB 400 Amps |
| 132 | Supply and fix in replacement of Copper Air termination rod 12 mm dia single pointed 300mm longalong withbase plate welded at bottom of termination rod, of size 10 cm longfabricated out of 32 x 6 mm thick Copper strip along with making 9mm dia for fixing in fastners complete all as specified. |
| 133 | Supply and fix in replacement of aluminium strip 25x3 mm with saddle and fixing screws etc for roof conductors and down conductors above ground level complete all as specified and directed. |
| 134 | Supply and fix in replacement of GI Strip 32x6 mm with saddle and fixing screws etc from test terminal block to earth pit complete all as specified and directed. |
| 135 | Supply and fix in replacement of Porcelain insulatorofexisting size forisolation of conductor from the building wall upto a height of G+8 floors by providing 15cm long fastners at every 16 cm distance in the wall complete all as specified and directed. |
| 136 | Supply and fix in replacement of LED Aviation light with enciosure of ABS material, 50 Hz, IP-55 complete all as specified and directed. Make : Cat Part No. BGAV 302 LED of Bajaj or equivalent in Philips/Surya |
| 137 | M & L for conducting oil filtration by stream line / Vacuum type filter machine to remove the moisture/carbon particles to improve required BDV of oil 50 to 60 KV for 1 min for power transformer & as BDV of oil 40 to 50 KV for 1 min for distribution transformer incl routine testing after filtration for any capacity of transformers/AVR/CT/PT units all as directed. (Note : The contractor shall change the filter assy before starting the filtration of transformer / AVR in presence of Engr In charge)Note:- (i) Test results before and after filteration shall be submitted on completion in tripilicate. (ii) Necessary electric for filtration plant shall be issued by department,required length of cable/switch etc shall be arranged by the contractor. |
| 138 | Supply and filling of fresh transformer power oil of BDV not less than 60 KV for topping up of reduced level of transformer due to evaporation/ leakage/losses due to dehydration or for replacement complete including removing of old unservicable transformer oilinto conservator tank/body tank of transformer as per IS-335 2018 complete all as specified and diredcted.Note:- 1. The taransformer oil for topping up shall beofDi-electric strength more than 60 KV for 1 miniute at 2.5 mm gap between the two electrodes.2. Oil shall be supplied at site in sealed barrel. |
| 139 | Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 100 KVA to 500 KVA out door type transformer including taking down u/s from the transformer complete all as specified. |
| 140 | Supply and filling silica gel inside breather assembly of transformer complete all as specified and directed. |
| 141 | Supply and fixing Cable jointing kit for 11 KV (Earthed) grade cable for straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm complete all as specified and directed. |
| 142 | S & F in repairs transmission class type drop out fuses 11000 volts rating 25-50 amps,outdoor type complete. |
| 143 | Taking down Triple pole mechanism completefrom the site, supply and install mechanically operated, mounted on insulator and steel frame,with opertaing mechanism worked from ground level with GI pipe medium grade, for current rating upto 200 Amps and Air break (switch) insulator suitable for HT 11 KV out door typeall as directed.Make : Atlas/GEC/Pactil or equivalent |
| 144 | S & F in repairs including testing of air break switchassembly out door type 11 KV supply, 200 Amp incl mounting bracket & post insulator comlete all as directed. Make : Atlas/GEC/Pactil or equivalent |
| 145 | S & F in repairs lightining arrester high tension,expulsion type,transmission class,discharge capacity 65 kilo ams suitable for 11000 Volt supply complete with all fitting suitable discharge capacity including necessary fixing arrangements made out of MS angle/flats,nuts and bolts etc complete all as specified and directed |
| 146 | M & L in repair of Cross arms, bracings, supports, clamps and back plate fabricated from structural steel section including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shapes size as indicated or directed and inclusive of one primer coat, and one under coat and one finished coat of aluminium paint incl dismantling of old unsv complete all as specified. |
| 147 | M & L for carrying out primary & secondary injection test of11 KV indoor /outdoor type current transformer (Set of three) of VCB\"s by using standard injection test method and checking the electrical circuits for fault condition, all relay testing andproper functioning incl submittingthe test report all as directed by Engr in charge. (Note : PIT/SIT for VCB will be carried outand each primary & secondary injection test will be measured as one unit and paid) |
| 148 | M & L for servicing of VCB 11 KV, 630 A , 25 KA,350 MVA/ bus couplerby dismantling cleaninggreasing the complete VCB with attached relays bus bar etc insulation testing, setting the contact gap by measuring as required reassembling the VCBand reinstalling back to its original positionchecking and repairing the currentcircuit panel wiring, replacement of new spares as required completeincluding operational testing and commissioning all as directed. Make : ABB /Sneider/L&T.Note : New spares will be measured and paid separately under relavent item of this schedule. |
| 149 | Supply only the following spares for outdoor/indoor VCB 11 KV, 630 A , 50 KA,350 MVAas approved by GE agianst Item Ser No. 143. Make : ABB/L&T/Seimens |
| 150 | a) Closing coil24/30V DC |
| 151 | b) Tripping coil 24/30V DC |
| 152 | c) Interrupter Housing |
| 153 | d) Digital Voltmeter / Ammeter 96 x 96 mm size |
| 154 | e) LED type indicator lamp assembly |
| 155 | f) spout incoming side |
| 156 | g) spout outgoing side |
| 157 | h) Epoxy insulators bushings for incoming / out going cables / bus bar support as per existng size of VCBs |
| 158 | j) Gear system assembly complete with handle for charging / discharging of VCBs |
| 159 | k) 15 Finger jaw contact |
| 160 | M & L for servicing of LT panel boards/Automatic synchronising panel of any type, capacity and sizes by dismantling/opening the LT panel by dissconnecting all electrical connection and cleaning, greasing, painting, repairing the complete LT panel with attached relays, bus bar, CT/PT etc. and insulation testing, setting the contact gap by measuring as required, repairing/renewel of the hinges, locking arrrangement of the panel,painting of LT panel of any description with one coat of synthetic enamel paint of standard colour code over the existing painted surfaces after preparing the old painted surfaces by using spray gun,reassembling the LT panel and reinstalling back to its original position checking and repairing the current circuit panel wiring, replacement of new spares as required completeincluding operational testing and commissioning all as directed. (Note : 1. Petty/small spares required for the smooth functioning of the panel deemed to be included in the quotated rate.2. Only new major spares shall be measured and paid separately under relavent item of this schedule) and the same as per the direction given by Engr-in -charge. |
| 161 | Supply only the following spares for outdoor/indoor LT panel boards/Automatic synchronising panel as approved by GE agianst Item Ser No 150 all as specified and as directed. |
| 162 | (i) Digital Ammeter 96 x 96 mm size |
| 163 | (ii) Digital Voltmeter 96 x 96 mm size |
| 164 | (iii) Contactor 250 Amp, 4 pole suitable for 160 KVA DG set sync panel |
| 165 | (iv) Microprocessor for Automatic synchronising panel suitable for 160 KVA DG set |
| 166 | (v) Digital timer for street light Make : Cat Part No. DHTJW01016 in Havells or equivalent |
| 167 | Taking down existing street light fittings fitted at any type of pole and Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete including connection twin core copper wire drawn through rigid PVC pipe not less than 20 mm dia from junction box to light fitting complete all as specified and directed.Note :-1. Rate of the LED light fitting includes LED light fitting, conncection twin core copper wire of suitable size, rigid PVC pipe not less than 20 mm dia and all accessories required to fit the light at any type of pole.2. GI bracket is not included in the quotated rate. |
| 168 | Taking down existing unserviceable terminal box and S & F hot pressed moulded SMC junction/terminal box of internal diemension of 200x140x95 mm and hinged door,including 01 No 4 way connector 415 Volt, 63 Amp, made out of polycorbanate or bakelite and 1 No. MCB of 6 Amp with DIN bar,drilling holes for cable connections connecting incomming and or out going cables by providing cable luggs/glands of suitable size fixed on pole by means of clamps made out of MS flat iron of suitable sizes,duly painted with two coats of red oxide zince primer complete all as specifiedand directed. Make : Sintex/L&T/Havells or equivalent |
| 169 | S&F in repair cable route indicator made out of 50x6 mm angle iron 60 mm long embedded in PCC block of suitable size with moulded letter HT cable or LT cable suitable inscribed on cast iron circular plate 8 mm thick 100 mm dia complete including PCC 1:3:6 type C-2(using 40 mm graded aggregate block of 150x150x150 mm size ) all as specified and directed by Engineer - in -Charge. |
| 170 | M & L for removing vegitation, grass, scrubs and bushes growing in Sub station yard along with fancing by mannually / mechanically and keep the sub station yard neat and clean complete all as specified and as directed. Note :- Unit rate quoted deemed to include to keep the installation neat and clean through out the period of contract and each cleaning will be measured and paid separately. |
| 171 | Supply and fixing shock treatment chartduly mounted on a wooden frame with 5mm thick glass as directed having front area 1.20 Square Metre complete all as specified and directed. |
| 172 | M & L for servicing/repair of the Solar street light fittings fitted at pole by taking down LED light fitting and solar plate fitted at the pole, cleaning of the solar plate, repairing /replacing the defective parts, charging the battery etc. for making the solar light fitting functional complete all as specified and directed.Note :-1. Rate ofeach job does not include the cost of solar plate and battery. If the same is found defective will be measured and paid separately.2. Rate of the job inclusive of the cost of replacement minor parts such as cable lugs, cable glands, connection wire, MCB, DB\"s etc required for the smooth functioning of solar street light. |
| 173 | Supply only the following spares for Solar street light fittings as approved by GE agianst Item Ser No.152 all as specified and as directed:- |
| 174 | (a) Solar PV Moduleswith Poly/Multi Crystalline Silicon Solar cells of60 Wp |
| 175 | (b) 24 AH Li Fe PO4 battery |
| 176 | (c) 25 W LED light fitting suitable for solar light |
| 177 | Periodical maintenance / servicing of Diesel Generator set of 75 KVA capacity installed at CG DHQ-4, Fort Kochi for smooth operation of generator sets and ensuring the serviceablity by renewing the defective spares, settings/ caliberation etcfor the following capacity Model/ Make by carrying out inspection /work by an authorised dealer of OEM complete all as specified and directed:-(DG set make:- Engine -Ashok Leyland, Alternator - Kirloskar)Engine Servicing /Gen overhauling :-(a) Checking the lubricant oil, topping up & changing filters if required(b) Checking the lubricant level and replacing if required(c) Checking of alternater, battery charging, fanbelt and adjusting/renewing if required(d) Checking/adjusting of sensers / controls of the Engine(e) Cleaning the cylinder head, lever, lube oil, gudgen pins etc(f)Draining fuel filter bowels to remove water/sediments and refixing with new gaskets after cleaning/ renewing the filters(g) Checking and tightening all external fasteners and arresting all leakages by renewing deffective nuts bolts washers etc whereever required(h) Checking and arresting leakages by tightening all lube and fuel/ hose connections by renewing defective washers(i) Checking of air filters subject to 250 hrs running or six months whichever is earliest for renewal(j) Cleaning of air filter assembly(k) Renewal of all external rubber parts including radiator hose pipes, sir clips/clamps with nuts bolts etc(l) Arresting all water /lubricant/fuel leakages (m) Checking of all engine parameters and ensuring trouble free performance |
| 178 | (n) Removing US spares and fixing of new spares including testing etcAlternatorServicing:-(a) Checking lubricant in the bearings(b) Checking electrical excitation system and repairing if required(c) Checking alternator insulation values and tightning the electrical connections etc(d) Checking circuits of various connections(e) Cleaning the slip rings/brushes etc(f ) Removing US spares and fixing of new spares including testing etcAMF Panel Servicing:-(a) AMF Panel will be maintained for good operation with the existing components. Any components found defective will be renewed and paid under relevant item of schedule. (b) Removing US spares and fixing of new spares including testing etcNotes: 1. (a) Spares, lubricant, coolant etc required for engine, main alternator & AMF panel will be measured and paid seperately.(b) Charges for Major repairs/ top overhauling of engine, rewinding of alternator, alternator major overhauling due to normal wear & tear will be out of scope of the work. However the damages caused due to negligence of the contractor will be made good without any extra cost by the contractor. Cost of minor spares required for proper operation of DG set and Control panel shall be deemed to be included in the rate quoted.(c) U/s spares shall be measured under Schedule of Credit2. HPP (N) required at the time of mainteance/testing will be issuedby MES.3. Labour charges fordismantling/taking down and replacement/fixing new parts as and when required. |
| 179 | Same as per item No. 154 but for 160 KVA DG setGreaves Power Location:- CGDHQ-4 Fort Kochi Power house - 02 Nos |
| 180 | Removing and replacing the old unserviceable AVR (Automatic Voltage Regulator) suitable for Greaves Power cotton curve of capacity 125-250 KVA having input voltage 2 phase + neutral sensing voltage 415 output voltage 95V DC, output current 4A DC voltage regulation +/- 1 % average volts, over excitation current tripping, fuse protection 4A, fast acting and frequency 50 Hz complete all as directed by Engr-in-Charge. Make :Kirloskar / Cummins/Crompton Greaves. |
| 181 | Supply only lubrication oil filter element with \"O\" ring of Make MICO / Kirloskar / Ruston/Greaves Powe cotton as required at site for 75 KVA capacities of DG Sets all as directed by Engineer-in-Charge. |
| 182 | All as per item No. 157 here in before but 160 KVADG set. |
| 183 | Supply only fuel filter element with \"O\" ring of Make MICO / Kirloskar / Ruston / Greaves Power cotton as required at site for 75 KVA capacities of DG Setsall as directed by Engineer-in-Charge. |
| 184 | All as per item No. 159 here in before but 160 KVADG set. |
| 185 | Supply only Air filter elementinner and outer as required at site with \"O\" ring of Make MICO / Kirloskar / Ruston / Greaves Power cotton as required at site for 75 KVA capacities of DG Sets all as directed by Engr-in-Charge. |
| 186 | All as per item No.161 here in before but160 KVADG set. |
| 187 | Supply only Governor control cable inner and outer for the 75 to 160 KVA capacity DG Set complete all as specified and directed. |
| 188 | Supply only Solenoled shut off valve sup and fix new Solenoled shut off valve assembly complete suitable to operate with 12/24 volts DC all as specified and as directed. |
| 189 | Supply only Lube oil pressure sensor for Engine complete all as specified and directed. |
| 190 | Supply only Ammeter for DG set 75 to 160 KVA capacity complete all as specified and directed. |
| 191 | Supply only Speedo meter cable including outer and inner cable complete all as specified and directed. |
| 192 | Supply only Push button switch complete all as specified and directed. |
| 193 | Supply only Ignition switch heavy duty with keys complete all as specified and directed. |
| 194 | Supply only AMF relay and replacement of micropocessor 12V/24V complete all as specified and directed. |
| 195 | Removing the silencer and replace with new gasket and manifold to arrest all exhaust leakage for Genset of capacity 62.5 KVA to 250 KVA all as specified and as directed. |
| 196 | Supply only \"V\" Belts/pump \"V\" belts dynamo \"V\" belts for:- |
| 197 | (a) 75 KVA DG set |
| 198 | (b) 160 KVA DG set |
| 199 | Supply only Flexible over flow pipe steel armoured flexible with suitable end sockets of size 15 mm dia of suitable length and size complete all as specified and directed. |
| 200 | Supply only multi-grade 15W40 lubricating oil for DG Sets as per manufacturer’s recommendations, complete all as specified and directed. Make- IOC, Castrol, Hindustan Petroleum |
| 201 | M&L for distilled water to be filled in batteries all as directed by Engr-in-Charge |
| 202 | Supply only coolant for radiator as per manufacturer’s recommendations, complete all as specified and directed. Make- Castrol, Servo, Cummins |
| 203 | Taking down old Unserviceable self motorof capacity 62.5 KVA to 200 KVAand servcing includingreplacment of Unserviceable spare aprts Brush, holder, solonoid switch, armature bush, filed coil complete all as specified and directed. |
| 204 | Dismantling andremovingfuel injection pump (FIP) of cap 62.5 KVA to 200 KVA andtaking out to authorised workshop andreplacing unserviceable element, delivery valve, balance wait, lever, bearing after repairing fixing to the engine testing for satisfactory function all as directed by Engineer-in-Charge |
| 205 | Repairs to dynamo / alternator including removing from position remove the burntout armature , clean the internal surfaces , servicing, supply and fix new armature with brushes and brush holder , necessary lathe work with bushes etc all as directed |
| 206 | Supply and replacement of radiator hose of any capacity complete all as specified and directed. |
| 207 | Supply and repalcement of fuel hose set nylon type of any capacity complete all as specified and directed. |
| 208 | Supply and replacement of radiatorfan belt of any capacity complete all as specified and directed. |
| 209 | Supply and replacement of valve door packing of any capacity complete all as specified and directed. |
| 210 | Supply and repalcement of turbo cooler rubber hose of any capacity complete all as specified and directed. |
| 211 | Supply and replacement of radiator mounting set of any size complete all as specified and directed. |
| 212 | Supply and replacement of oil drain hose set complete complete all as specified and directed. |
| 213 | Supply and replacement of controle unitfor DG set any any capacity complete all as specified and directed. |
| 214 | Disconnecting the existing battery of capacity 12V / 180 AH from the DG set, taking it to battery workshop, draining out the complete unserviceable electrolyte acid from the battery, filling up with new Electrolyte acid to the required level, charging the battery, testing the battery for correct specific gravity, bringing back to the location, connecting to DG set, start the engine for satisfactory function all as directed by Engineer-in-charge. |
| 215 | Repairs to 24 V battery charging alternator assembly by removing, dismantling, replacing the unserviceable burnt rotor and stator assembly, assembly reaffixing to the engine and testing for satisfactory charging of battery all as directed by Engineer-in-Charge. |
| 216 | All as per item No 189 above but of 12 V battery charging alternator complete all as specified and directed. |
| 217 | Repairs to 12/24V self starter by removing, dismantling and taking it to authorised workshop andreplacing unserviceable Armatureincluding field coiltapping re-fixing to the engine testing for satisfactory function all as directed by Engineer-in-Charge |
| 218 | Supplyand fix in replacement of Dry cell tubular type 12 V / 110- 180 AH and initial charging complete including inbuilt charger including required electrolite /distilled water etc and fixingas required at site to the concerned DG Set all as directed by engineer-in-charge. Make : EXIDE/AMRON |
| 219 | Painting of the following DG set after preparing the external surface apply one coat of spray painting by superior quality enamel paint of appropriate colour for engine, alternator, connected panel, base frame, radiator, battery stand, and cleaning the meter panel writting of MES No etc all as directed |
| 220 | (a) 160 KVA capacityinstalledat CGRA Rameswaram |
| 221 | (b) 75 KVA capacity DG set at CGDHQ-4 |
| 222 | Periodical maintenance / servicing of Electrical Incinerator of 20 KG/Hr capacity for smooth operation by dismantling/opening of the incinerator removing defective parts, replace them with the new parts, cleaning of the entire incinerator from inside, repair to blower fan, MCB, tightening all electrical connection, replace cable lugs and cable gland with new one of existing sizes and ensuring the serviceability of the electrical incinerator by testing of the same after repair complete all as specified and directed for the following :- |
| 223 | (a)20 KG/Hr capacity installed at CG DHQ-4, Fort Kochi |
| 224 | (b)20 KG/Hr capacity installed at CGRA Rameswaram |
| 225 | Periodical maintenance / servicing of Solar Power Plant (on Grid) of 4 X 10 KWp capacity installed at CGRA Rameshwaram, Kochi for smooth operation of Solar Power Plant and ensuring the serviceablity by renewing the defective spares, settings/ caliberation etc carrying out inspection /work by an authorised dealer of OEM complete all as specified and directed.(Solar Power Panels Make:-Vikram Solar Make of Solar Inverter :- Delta)Solar Panels :-(a) The timely and regular cleaning of solar cells and PV panels. Cleaning of the Soalr Panels shall be done using soft cloth,biodegradable soap, wiper, and a soft bristles brush. Don\"tuse an abrasive sponge or soap to clean the solar panels.(b) Regular maintenance of all thermal-based components.(c) Testing and upkeep of circuits to ensure smooth functioning of the Soalr system.(d) Checking/adjusting of sensers.(e) Carrying out visual inspections of Solar sysytem fortnightly. (f)Conducting verifications of the PV system operations.(g) Tracing of IV curves and thermal imaging.Controller and inverter(a) Testing and upkeep of circuits to ensure smooth functioning of the Solar system.(b) Check the connections, make sure that they are fixed tightly.(c) Maintain the cleanliness of the air intake filter for the smooth functioning of the inverter.(d) Checking of the error code if any and rectify the same. |
| 226 | (e) An electrical inspection to confirm that all the strings of solar array are operating.(f ) Interior inspection of all devices, boxes, inverters, switches, etc.(g) Infrared inspection of electrical connections looking for loose connections and hot spots.Notes: (i) Spares, wires, nut & bolts etc or any other petty/small parts required for maintenance and servicing of the Solar Plant is inclusive in the quotated rate.(ii) Charges for Major repairs, changing of the solar panel, inverter, changing of the contactor will be out of scope of the work. However the damages caused due to negligence of the contractor will be made good without any extra cost by the contractor. Cost of minor spares required for proper operation of Solar plant and Control panel shall be deemed to be included in the rate quoted. |
| 227 | Schedule of Credit (Minus) Rs.69840.00NOTE: Bidder shall insert credit amount of Rs. 69840.00 as ratein Green field under Col-13. |