Assam Gas Company Limited has published Tender For Procurement Of Fire And Gas Systems. Submission Date for this Tender is 29-12-2022. Forming Tools Tenders in assam Assam. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 06-Dec-2022 | Reply to Bidders Queries | Other | 15-12-2022 |
2 | 06-Dec-2022 | Corrigendum 1 | Date | 15-12-2022 |
3 | 13-Dec-2022 | Reply to Bidders Quarries 2 | Other | 15-12-2022 |
4 | 15-Dec-2022 | Price Bid opening date Amended | Date | 29-12-2022 |
5 | 22-Dec-2022 | Reply to Bidders Queries 3 | Other | 29-12-2022 |
Sl. No. | Item Description |
1 | PART A-F&G System Supply, Installation, commissioning and testing of F&G system for Nambor – Golaghat – Numaligarh Gas pipeline project as per scope of work, specification, Control system schematic, and I/O attached with this requisition. F&G System supplied shall be complete in all regard and shall consists of the following: 1. Hardware – • F&G system shall consist of Dual 32-bit CPU, Minimum 32 Mbyte SDRAM (Extendable), Power supply modules, Input / Output modules, Modbus / Ethernet base interface and shall support minimum 100 Mbps redundant Ethernet communication, serial communication speed, and supporting multiple communication protocol, SIL 3 rated located at Golaghat sub-control room; • F&G cabinet (8 nos.) shall be standalone floor mounted, dimensions 800x800x2200 mm (WxDxH) and IP-54 rated as per IEC 60529; Exterior portion of all panels and closed cabinets shall have a color of RAL 7032 (Siemens grey), MOC shall be CRCA steel, Front opening at Nambor, Khoraghat, Uriumghat, Golaghat, Numalighar, Thoramukh, Hamiramukh and SV stations (1 Nos.); 2. F&G System shall interface with proposed new RTU at terminals through secure and redundant communication link. 3. Software with license etc., complete with system configuration and programming. 4. Testing – FAT / SAT, Installation, commissioning and training. 5. Supply of erection & commissioning spares; |
2 | Supply,Installation, Comissioning and testing of F&G devices as per Datasheets, Scope of work, standard specifications etc., attached with this tender Supply & Installation and commissioning of following F&G devices such as gas detectors, beacons, hooters and MCP. Supply and Laying of cable inside the cable trench, cable tray for hardwired signals and power cables from gas sensors to gas detectors control unit including cable glands, necessary hardwares, glanding, termination, ferruling, dressing etc. at both ends. Installation and erection of cable trays and, supply of erection materials, cable ferrules, cable lugs, cable tie. |
3 | Point gas detector - IR type, 4-20 mA HART, 3 wire 24 VDC loop powered flame proof, IP-67, housing material SS316 without display. |
4 | Open path gas detector UV / IR type, 4-20 mA HART, electronic 24 VDC to transmitter,24VDC loop powered to receiver, flame proof, IP-67, housing material SS316 without display. |
5 | Horn Dual Tone, 24 VDC, IP67. |
6 | Beacon Xenon Discharge lamp, 24 VDC, IP67. |
7 | Manual Call Point type break glass with nickel plated brass hammer & SS Chain ,24 VDC, IP67, |
8 | 1T X 1 .5 Sq. mm , Fire resistant,Over all Screened |
9 | 6T X 1 .5 Sq. mm , Fire resistant,Over all Screened |
10 | 1P X 1 .5 Sq. mm, Fire resistant,Over all Screened |
11 | 6P X 1 .5 Sq. mm, Fire resistant,Over all Screened |
12 | Junction Box -F&G |
13 | PART B-Fire Alarm Control Panel (FACP) - Control Building 1. Fire Alarm Control Panel (FACP): Design, detailed, engineering, supply, configuration, testing, installation, erection and commissioning of Addressable, Intelligent Fire Detection and Alarm Panel for automatic fire detection & communciation of alarms for various types of detectorsinstalled like multi sensor, loop isolators, manual call points, hooters, beacon etc installed in respective control room with supporting multiple communication protocol. - 2 Loop Addressable FACP shall be installed in suitable location inside control building at Nambor, Khoraghat, Uriumghat, Golaghat, Numalighar, Thoramukh, Hamiramukh and SV stations(1 Nos.);- 08 Nos. FACP -4 Loop Addressable FACP shall be installed in suitable location inside control building at Golaghat Sub-Control Room;- 01 Nos. FACP - Supply, laying of cable inside Control room (Portacabin) between detectors, MCP, hooter and FACP including glanding, termination, ferruling, dressing etc. at both ends. Supply & installation of cable trays (if necessary), supply of erection materials, cable ferrules, cable lugs, cable tie etc. for successful commissioning of FACP. 2. FACP shall interface with F&G system at terminals through secure and redundant communication link or hardwired; 3. Supply of erection & commissioning spares; 4. Testing – FAT / SAT, Installation, commissioning and training. |
14 | Supply and installation of Addressable Multi Sensor(Smoke+Heat) complete with wiring and accessories |
15 | Supply and installation of manual call point complete with wiring and accessories |
16 | Supply and installation of hooter indoor complete with wiring and accessories |
17 | Beacon Xenon Discharge lamp, 24 VDC, IP67, Enclosure MOC- Cast aluminium (LM6) |
18 | Part – C: Comprehensive Annual Maintenance Contractor (CAMC) for F&G and FACP System for a period of 4 years, applicable after successful completion of warranty phase. |
19 | 1st year after warranty period |
20 | 2nd year after warranty period |
21 | 3rd year after warranty period |
22 | 4th year after warranty period |