Housing Urban and Rular Development Government Departments Closing in 0 days TDR #34830369

Tender For Construction Of Modern Crematorium At Chirkunda Nagar Parishad

Issued by Government Departments · chirkunda, Jharkhand
Tender Value
Ref. Documents
Estimated cost
Bid Submission
22 Nov 2022
0 days left
EMD
2.93 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
chirkunda → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Modern Crematorium At Chirkunda Nagar Parishad

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 20-Nov-2022 PERIOD OF COMPLETION Other 22-Nov-2022

BOQ

Name of Work:CONSTRUCTION OF ELECTRIC CREMATORIUM AT CHIRKUNDA NAGAR PARISHAD
Sl. No. Item Description
1EARTH WORK INEXCAVATION INFOUNDATION Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I.
2FILLING IN FOUNDATIONTRENCHES AND PLINTH in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume)
3Providing coarse clean SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume)
4Providing designation 75-A, BRICK FLAT SOLING joints filled with local sand including cost of watering,taxes and royalty all complete as per building specification and direction of EngineerIncharge
51:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
61:1.5:3 (1 cement : 1.5 coarse sand(zone-III): 3 graded stone aggregate 20 mm nominal size)
7Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
8Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
9Providing, hosting and fixing above plinth level up to floor level precast Reinforced cement concrete in shelves, including setting in cement mortar 1:3 (1cement : 3 coarse sand ), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but , exculuding the cost of reinforcement, with 1:1.5:3 (1cement : 1.5 coarse sand(zone-iii) : 3 graded stone aggregate 20mm nominal size)
10Foundations, footings, bases ofcolumns, etc. for mass concrete
11Columns, Pillars, Piers, Abutments,Posts and Struts shuttering taken @ 14m2/m3
12Suspended floors, roofs, landings,balconies and access platform
13Lintels, beams, plinth beams, girders,bressumers and cantilevers
14Weather shade, Chajjas, corbels etc.,including edges
15providing Tor steel reinforcement of8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL)TOR 8 MMDIA. @ 30% of total steel
16providing Tor steel reinforcement of 10mm,12mm,& 16mm. dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I.TOR.(a) 10mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL,JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}10 MMDIA. @ 15% of total steel qty.
17providing Tor steel reinforcement of10mm,12mm,& 16mm. dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I .(b) 12mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL,JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}) (c) 16mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}) providing Tor steel reinforcement of 20mm,25mm, 28mm & 32mm. dia bars as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods inposition all complete as per building
18Providing designation 75A brick work inC.M (1: 6) in foundation and plinth with approved quality of clean coarse sandof F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I.
19Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stoneaggregate 20mm nominal size)
20l in cement conncrete work in doses by
21Providing designation 75 A BRICK WORK in CM. (1:6) inSUPERSTRUCTURE with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening,racking out joints to 15 mm depth,curing, taxes and royalty all complete as per building specification and direction of EngineerIncharge
22Providing125 mm thick REINFORCED DESIGNATION75 A BRICK WORK in C.M. (1:4) inSUPERSTRUCTURE with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, cost of materials, racking out joints to 15 mm depth, carriage, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction ofEngineer Incharge .
23Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brickmasonry.
24ing screening, curing with all leads & lifts
25eening, curing with all leads & lifts of wa
26Extra for providing and mixing water proofing material in cement plaster work in proportion recommended bythe manufacturers.
27Supplying, and fixing fan hook of 16mm dia M.S. bar 1 meter long bent to required size and shape , placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/I. (where materials is not suppliedby the deptt.)
28supplying, fitting and fixing 250X20X6mm L-type M.S clamp properly fishtailed, including maiking holes and setting as same in 250X125X75mm. Cement concrete block (1:2:4) with cost of all labour and materials and taxes as per buildingspecification and direction of E/I.
29Making 6X6mm grooves in plaster surface over walls truely horizontal or vertical as specified at regular intervals, at all heights including cleaning, finishing, scaffolding and curring with all leads and lift of water all complete as per building specificationand direction of E/I.
30ke, in all colours and shades, laid on 20
31Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. completeat all levels.(8.2.2.2.)
32Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointing with white cement including rubbing, polishing and cost of curring taxes and royalty all complete as per building specification and direction and E/I.(5.6.23.2)
33Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).(11.20.4)
34Supplying, fitting and fixing good quality, well dressed and well seasoned sal wood work in chaukhat in doors, windows skylights, fanlights and C/W celetial windows openings, including wedge over all clamps complete including application of two coats of wood preservative of approved quality on the surface butting walls and lintels all completeas per building specification and direction of E/I.
35Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (Approved Brand - Green club/ Green Optima/ Century/ Duro).(9.21.1)
36Providing and fixing plain lining with necessary screws/nuts & bolts/ nails, including a coat of approved primer on one face, and fixed on wooden /steel frame work, complete as per direction of Engineer-incharge (Frame work shallbe paid for separately).(9.140.1)
37nsity protective surface layer and revers
38Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i. e. at top, bottom and sides with required EPDM rubber / neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in- charge. (Glazing, paneling and dash fasteners to be paid for separately) : ( 21.1.1.2)
39Providing and fixing glazing in aluminium window, ventilator shutters etc. with EPDM / Neoprene gasket etc complete as per the architectural drawings and the directions of engineer in-charge. (Cost of aluminium snap beading shall be paid in basic item):
40Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot andsingle piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge(21.4.1).
41Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
42Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in-charge. (Approved brand -Godrej/ Dorset)
43th SS screws etc. coplete as per directio
44Providing and fixing aluminium hanging floor door stoppers ISI marked anodized (anodic coating not less than grade Ac 10 as per I.S. 1868) transparent or dyed to required colour and shade with necessary screws etc.complete. (9.101.2)
450 as per IS : 1868) transparent or dyed t
46Providing and fixingaluminium TOWER BOLTS ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required color or shade with necessary screws etc. complete.300X10MM(9.97.4)
47ns 25mm minimum depth on all edges o
48Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.)
49Providing and fixing sliding arrangement in racks/ cupboards/cabinets/ Window shutter by with stainless steel rollers to run inside C or E aluminium channel section (The payment of C or E channel shall bemade separately)
5050% of cement mortar of mix 1:5 ( 1 cem
51Providing applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface evenand smooth copmlete .
52Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per buildingspecification and direction of E/I
53Finishing walls with Premium Acrylic Smooth exterior paint with silicone additives \"Snowcryl - XT\" of M/S Snowcem India Ltd, or equivalent ofrequired shade.
54Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall suface to prepare the surface evenamd smooth complete.
55New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied@ 2.20kg/ 10 sqm
56cleaning the surface after removing dirt,
57Providing one coat of painting with ready mixed paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
58Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
59Supplying and fixing Rolling Shutter of approved make, made of required sizeM. s. laths, interlocked together through their entire length and jointedtogether at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire od adequate strength confirming to IS : 4454-part 1 and M.S. top cover of requiredthickness for rolling shutters.
60Providing and fixing ball bearing forRolling Shutters
61Extra for providing mechanical device chain and crank operation for operatingrolling shutters.
62Providing & fixing on wall face unplasticised -Rigid P.V.C. rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . Singlesocketed pipes. 110 mm dia
63Providing & fixing on wall face unplasticised -P.V.C. moulde fittings / accessories for unplasticised -RigidP.V.C. rain water pipes conforming to IS: 13592 Type A including jointing withseal ring conforming to IS: 5382 leaving 10mm gap for thermalexpansion .110 mm
64SHOE - 110MM
65BEND - 110 MM
66Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.(12.43.2)
67Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc.complete.(10.16.1)
68Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15- 18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55mm) with EPDM seal, complete upto
69Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm)
70Flashings/ Aprons.( Upto 600 mm)
71Gutter (600 mm over all girth)
72Providing fixing thermal insulation of ceiling (under deck insulation) with Resin Bonded Fibre glass wool conforming to IS : 8183, density 24kg / m3, 50mm thick, wrapped in 200 G Virgin Polythene bags, fixed to ceiling with metallic cleats (50x50x3 mm) @ 60 cm and wire mesh of 12.5 mm x 24 gauge wire mesh, for top most ceiling of building.
73Making Soak Pit 2.5 m diameter 3.0 meter deep with 45x45cm dry briick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long completeas per standerd design .
74Providing & ejecting Chemical emulsion for pre-constructional ANTI TERMITE TREATMENT and creating a chemical barrier under a alround the column pits, wall trenches, basement excavation, top surface of plinth filling junction of wall and floor along the external perimeter of building expansion joints, surrounding of pipes and conducts tic. complete (plinth area of the building at ground floor only shall be measured) with Chlorpyrifos 20% EC as per building specification and direction of E/I. (4 stages treatment)
751:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size)
76Providing 12mm cement Plaster (1:3) with clean coarse sand of F.M.1.5 with 1.5mm floating coat of neat cementin DADO including rounding of junctions with floor, curing, taxes and royalty all complete as per building specificationand direction of E/I.
77ProvidingT.M.T. Reinforcementof following dia Rods as perapproved designand drawing includingcarriage of M.S. Rods of (Straightorin coils) to worksite, cutting, bendingand binding with annealedwirewithcost ofwireremoval ofrustplacingthe rods in position all complete as per building specification and direction and direction of E/I. (ONLY VALID FOR SAIL & TATA STEEL, JSPL, ELECTRO STEEL LTD. AND VIZAG STEEL)
78E/W in excavation of foundation trenches as per designed section in all kinds of soil,including moorum soil,soil mixed with kankar,pebbles and boulders upto 300mm size and disposal of the same (beyond 50m away from the toe of dam in the countryside ) within initial lead of 150m and lift of 1.5m, all lifts as per specification and direction of E/I.
79Supplying and laying (properly as per design and drawing )rip-rap with good quality of boulders duly packed including the cost of materials,royalty all taxes etc.but excluding the cost of carriage, all complete as perspecification and direction of E/I.
80Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pillasters, column piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed locks, anchor blocks, plain window sills, fillets, sunken floors, etc upto floor five level, excluding the cost of entering, shuttering, and finishing: 1:2:4 (1 cement : 2 coarse sand (zone- III) : 4 graded stone aggregate 20 mm nominal size)
81Providingrough dressed course stone masonry in cement mortar (1:6) in foundation and plinth with hammer dressed stone of less than0 .03 M³ in volume and clean coarse sand of F.M.2 to 2.5 including cost of screening,raking out joints to 20mm depth,curing, taxes and royalty all complete , as per specification and direction of E/I.
82Providing tuck pointing (1:3) in cement on brick work with clean coarse sand ofF.M. 1.5including screening, curing withall leadsand liftsof water,scaffolding taxes and royalty all complete as per building specification and direction of E/l.
83Excavation for roadway in soil using manual means including loading in truck for carrying of cut earth to embankment site with all lifts and leadupto1000 metres.
84Supplyingandstackingofgood earthatsite including royalty and carriage upto5 kmcomplete (earth measured in stacks will bereduced by20% for payment).
85Construction of granular sub-base by providing closegraded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreadingin uniformlayers withmotor graderon prepared surfaceandcompactingwith vibratorypowerrollertoachievethe desired density, complete as per clause 401Rate per cum for grading-III Material
86Construction of dry lean cement concrete sub base over a prepared sub- grade with coarse and fine aggregate conforming to IS:383, the size ofcoarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to beas per specifications, cement content not to be lessthan 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8- 10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineer-in- charge.
87Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401
88Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1cement: 3 coarsesand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in- charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
89Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block makingmachine with strong vibratory compaction, of approved s;ze, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction ofEngineer-in-charge.
90Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside theperiphery of the area cleared.
91Supplying and stacking of good earth at site including royalty and carriage up to 1 km (earth measured in stacks willbe reduced by 20% for payment).
92Providing and displaying of Areca Palm having ht. 1.80 m to 2.10 m with 8 to 10 suckers, well developed, fresh and healthy with lush green foliage in 30 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge.
93Providing and displaying of Croton baby golden variety having ht.30 cm andabove, well developed with full of fresh and healthy leaves in 20 cm size of Earthen pot/Plastic pot & as perdirection of the officer-in-charge.
94Providing and displaying of Dracaena Song of India (three in one), having ht. 30 cm and above, multibranched, well developed with fresh and healthy leaves in 25 cm size of Earthenpot/Plastic pot & as per direction of theofficer-in-charge.
95Providing and displaying of Philodendron Burgundy mounted on moss stick90 cm ht., well developed with full of fresh & healthy leaves from bottom to top in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge.
96Providing and Displaying Acalypha Different colour well developed, fresh & healthy with good foliage, multi branch 30 to 45 cm ht. in 20 cm size of Earthen Pot/ Plastic Pot bushy as perdirection of the officer-in-charge.
97Providing and Displaying Bamboo Buddha valley with fresh & healthy 3 to 4 suckers having 75 to 90 cm ht. in 25 cm size Earthen Pot/ Plastic Pot as perdirection of the officer-in-charge.
98Providing and Displaying Cycus cirsnallis well developed with fresh & healthy 35 to 40 lush green leaves in 40 cm Cement Pot as per direction ofthe officer-in-charge.
99Providing and Displaying Ficus nuda topiary well developed with fresh & healthy foliage 45 to 60cm spread 75 to 90 cm ht. bushy in 35 cm Cement Pot as per direction of the officer-in-charge.
100Providing and Displaying Fishtail palm well developed with fresh & healthy foliage leaves of ht 210 to 240cm Specimen in 35 cm Cement Pot as perdirection of the officer-in-charge.
101Providing and stacking of Foxtail palm of ht. 180-210 cm bottom girth 25-30 cm well developed in big size HDPE bags as per direction of the officer-in-charge.
102Providing and stacking of Michelia champa (Golden Champa) of height 90- 105 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.
103Providing and stacking of Polyalthia longifolia (Ashok) of height 180-195 cm. in gunny bag of size 30 cm as perdirection of the officer-in-charge.
104Providing and stacking of Bougainvillea (Variety Butiana, Lady Mary Baring, Mahara,Mohan,Scarlet Queen, Variegated, Glabra Formosa, PeruvianaOdissi, Paratha, Subhra,Thimma, Spectabilis L.N Birla, Refulgens) of height30 cm. to 45 cm. with 2-3 branches in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge.
105Providing & laying Selection no. 1 grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in charge
106Rabbit Dustbin
107bench with backrest Wooden/ Treated Bamboo/ Bamboocompositeplanks Fitted in cast iron frame.Painted/ Polished with protective laquer coat
108Wiring for light point/fan point/exhaust fan/call bell point with 1.5 sqmmPVC insulatedcopperconductor cablein surface / recessed PVC conduit with moduler type switch,moduler plate,suitable size GI box etc. asrequired .
109Wiring for light/ power plug plug with 2 X 4 sq. mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 Nos 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.(forAC &16A socket)
110Wiring for light/ power plug plug with 4 X 4 sq. mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 2 Nos 4 sq. mm FR PVC insulated copper conductor single corecable for loop earthing as required.
111Wiring for submainwiringwiththe following size ofPVC insulated, copper conductor single core cable in surface / recessed PVC conduit asrequired:2x1.5 sq.mm.+1x 1.5 sq mm(for toiletswitch board +6A socket)
1122x2.5 sq.mm.+1x 2.5 sq mm(for switchboard )
1134 x 6 sq mm +2x6 sq.mm. (Sub-MainsLight DB\"s)
1144 x 10 +2x10 sq.mm. (Sub-MainsPowerDB\"s)
115Supplying and drawing following sizes of PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit / PVC casing capping /as required. 2x1.5 sqmm
116S/F of following sizes of PVC conduit alongwith the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required .25mm PVC coduit.
117Supplying and fixing following moduler switch / socket on the existing moduler plate & switch box including connection but excluding moduler plate etc. asreqd.5/6 amps switch
1185/6 amps socket outlet
119Supplying and fixing stepped type electronic fan regulator on the existing modular plate & switch box including connection but exluding modularplateetc.as required..
120lying and fixingmodulertype blanking
121Supplying and fixing suitable size GI box with moduler platecover in the front on surface or in recess including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps. moduler type switch, connections painting etc.as required. (For light plugs).
122Supplying and fixing suitable size GI box with moduler platecover in the front on surface or in recess including providing and fixing 6 pin 15/16 amps socket outlet and 15/16 amps. moduler type switch, connections painting etc. as required. (For power plugs).
123Supplying and fixing offollowingway, three pole and neutral, sheet steel, MCB distribution board, 415 volts,on surface /recess,completewithtinned copper bushbar, neutral link,earth bar,din bar,detachable gland plate, interconnections, including painting, earthing etc. as required.4 way(4+12)double door Horizontaltype
1246 way (4+18)double door Horizontaltype
125Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C\" catagory, miniature circuit breaker (10 KA) of followingpolesin the existingMCB DBcomplete with connections, testing andcommissioning etc. asrequired.6/32 amps, Single pole
12632 amps.TPN
12740 amps.TPN
128ies, SP MCB (10 KA) in sheet steel encl
129Supplying and fixing 20 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 amps \"C\" curve, TP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required.
130Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade.of following size on wall surface asrequired. upto 35sq.mm.(clamped with 1 mm thicksaddle)
131Supply of PVC/ XLPE Insulated PVC sheathed heavy duty armoured electric cable with alluminium conductor for working voltage upto and including 1100 volts (conforms to IS:1554,part-1)10 sq mm x 4 core
13225 sq mm x 3.5 core
133Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
1343½ X 25 sq. mm (28mm)
135Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm width X 50 mm depth X 1.6 mm thickness.
136Supplying and installing following size of perforated Hot DippedGalvanised Iron cable tray \"bends\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.100 mm width X 50 mm depth X 1.6 mm thickness
137Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \"Tee\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 100 mm width X 50 mm depth X 1.6 mm thickness
138MAIN DISTRIBUTION BOARDS / L.T.PANEL. : - Design manufacture, supply installation, testing and commissioning of 16 SWG sheet steel fabricated cubical type floor mounting front operated construction, enclosure class - IP 52, finishing with 7 tank process and powder coating of the entire panel including covers in required shade complete with top / bottom ( as called for ) removable gland plates, cable alleys, double compression doors to achieve dust and vermin proofcomplete with all inter connectionssmall wiring by copper wires, ckt labels etc. The Copper Bus Bar shall be of suitable size for 500 volts, 3 phase 50 Hz TPN, electrolytic copper as per Is 8623 insulated by heat shrinkable sleaves with surround joints. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmeter, selector switches, CT\"s, PT\"s, etc. The panels shall be got LT PANEL (NORMAL SUPPLY) : -INCOMING (1- sets) each with following: 100 Amp,MCCB FP -1 no, Ammeter, ASS, CTs, Voltmeter, VSS, Fuses,1 Sets of Phase Indicating Lights with fuses & following accessories: - BUS BARS,OUTGOING: - b)2 Nos of 40 Amp TPN MCB, b)4 Nos of 32 Amp TPN MCB, b)4 Nos of 16 Amp TPN MCB,c)4 Nos of 16 Amp SPN MCB,LTPanel (Normal) as above(G.F)25-100 amps, 16 KA, fixed thermalsetting
13940 amps.TPN
1406/32 AmpTPN MCB
14116 amps.SPN
142LED INDICATOR LAMP R/Y/B/G
143DIGITAL VOLT METER 500V(3phaseclass 0.5)
144DIGITAL A METER 500V(3phaseclass 0.5)
1453way 4pole selector switch
146CT coil of CT tatio100/5 IS 2705 part 3
14725MM*5MM(1.15 Kg/Mtr)copper strip
14816 sq mm ISI marked FRLS PVC insulated single core copper conductorcable
14910sq mm ISI marked FRLS PVC insulated single core copper conductorcable
1506 sq mm ISI marked FRLS PVC insulated single core copper conductorcable
1511.5 sq mm ISI marked FRLS PVC insulated single core copper conductorcable
152S/F wall floor mounted cubical panel board , fabricated with 16 gauge iron sheet suitable for panel mounted switch disconnector ,incliding busbar chamber,insulator and painting etc.as required .(but without busbar copperstrip)
153S/F of Earthing electrode 80mm dia x 3mtr with backfill compound chemical 4 bag (per bag 25Kg)including earth cutting removing and installationcharge.
154Supplying and laying 25 mm X 5 mm GI strip at 0.50 metre below ground as strip earth electrode, including connection/ termination with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping with 2 sets of brass nut bolt and &spring washer spaced at 50 mm)
155P/F of lighting conductor finial, made of 25mm. Dia. 300mm. Long GI tube, having single prong at top, with 85mm.Dia. 3mm. Thick copper base plate including holes etc. complete asrequired.
156Rivetting, sweating and soldering of copper/GI tape (with another copper/GI tape base of the finial or any othermetallic object) as required.
157Providing and fixingGI tape 20mmx3mm thick on parapet or surface of wall for lightning conductoras reqd.(for horizontal run)
158Providing and fixingGI tape 20mmx3mm thick on parapet or surface of wall for lightning conductoras reqd.(for vertical run)
159Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of tinned G.I. bolts, nuts, chuk nuts and spring washers etc.complete as required.
160S.I.T.C of following rating surfface mounted LED tube light fitting suitabe for 230v 50Hz single phase supply etccomplete as required20/22w LED tube light
161S.I.T.C of following rating recess/ surfface mounted LED round /squareshape down light luminaierewith pressure die cast housing for single phase supply voltage luminarie shall be confirm to IS:10322 part-5/section 2 or IEC :62722 with all necessaryaccessories as required.10/12w LED round down light.
16218/20w LED round down light.
163S.I.T.C of following rating LEDstreet light luminaiere with pressure die cast housing and toughend glass cover (IP 66 protection )in xisting pole/pipe forsupply voltage 100-270 AC 50 Hz luminarie shall be confirm to IS:10322 part-5/section 3and shall be complete with all necessary accessories as required.90/100W LED street light.
164S.I.T.C of following rating LED Flood light luminaiere with pressure die cast housing and toughend glass cover (IP 66 protection )in xisting pole/pipe forsupply voltage 100-270 AC 50 Hz luminarie shall be confirm to IS:10322 part-5/section 3and shall be complete with all necessary accessories asrequired.120W LED Flood light.
165S.I.T.C of following size ceiling fan 3 blades confirming to IS-374:2019including wiring the down rods of standared length (upto 30 cm)with1.5 sq mm FR PVC insulated copper wire suitable for 230v 50Hz singlephase supply etc.as required.1400mm (56\")Ceiling fan
1669\" (230) mm )metal exaust fan
16712\" (300) mm )metal exaust fan
16815\" (380) mm )metal exaust fan
169S.I.T.C of following rating LED Post top lamp made in die cast aluminium housing with decorative clear /opalacralic diffuser on existing pipe including connection with 1.5 sq.mm copper conductor etc all complete as required.40/45W LED post top lamp opel/clear(gate light)
170S/F of 100w suspended type industrial COB LED highbay light with aluminiumdie cast heat sink.
171Providing of bulkhead fitting with 9/10w LED bulb.
172S/F 2 pin 5Aceiling rose on the existing junction box wooden block including connection etc ,as required.
173Erection of wall bracket / ceiling fittings of all sizes and shapes ontaining upto two GLS lamp per fitting complete with all accessories including connection etc as required.
174Installation, testing and commissioning of prewired, fluorescent fittings,compact fluorescent fitting of all types , complete with all accessories and tubes etc. directly on ceiling / wall, including connections with1.5 sq.mm.PVC insulated, copper conductor, single core cable etc as required
175Installation, testing and commissioning ofceiling fanincluding wiring the down rod of standard length (upto 30 cm.) with1.5 sq.mm. PVC insulated, copper conductor, single core cable and earthingetc. as required.
176Installation of exhaust fan upto 450 mm. sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connections, testing,commissioning etc. as required.
177Silent type DG set of capacity 30KVA three phase with AMF panel IS/IEC-60034-1. IS:1460 IS: 13018
178The LPG Gas crematorium is built withdouble chamber cremation furnace with a strong cremation bed and secondary air holes.Primary Chamber :• Fully insulated internal refractory lining, constructed from high graderefractory brick (OSSPL Make) ensuring a self-supporting interlocked arrangement, hot hearth design.• One hot hearth combustion burner (OSSPL Make), temperature controlled on-off, complete with internal air fans.• One waste ignition burner (OSSPL Make), temperature controlled on-off, complete with internal air fans (OSSPLMake).• One temperature control sensor Secondary Chamber :• Fully insulated internal refractory lining, constructedfrom high grade low thermal mass insulation.• One secondary chamber burnoutOSSPL Cremation Furnace : Mild steel[ IS 2062] & insulated with refractory bricks.OSSPL Cremation Trolley : Casted with refractory cement.Auxiliary Load-9 KWOSSPL Cremation Trolley-Trolley and stretcher is provide for easy loading of Dead body. With lowering and lifting arrangment. Trolley is prepared fromM.S Steel. (Manual or auto)Ash Collection-The arrangement for ash collection from combustion chambers shall be locking arrangement shall be provided on the opening for ash collection.Control Panel-It is consist of supply on/off switch, Digital Temperature Controller with back up control, Motor starter, Ampere meter, Fuse, MCCB,
179Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast iron P or S trap, 10 litre low level white P.V.C. Flushing cistern with munally controlled device (handle lever) conforming to IS:7231 Parryware/ Hindware with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. White Vitreous China Orissa pattern W C pan of size 580 X 440 mm with integral type foot rest.
180Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled devicde (handle lever), conforming to IS:7231, parryware/Hindware/with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. W.C. pan with ISI marked white solid plastic seat and lid.
181Providing and fixing C.P. brass bib cock of approved quality conforming toIS:8931 : 15mm nominal bore
182Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15mmnominal bore
183Providing and fixing C.P Soap Dish of aaproved size, shape and approved brand with concealed fittings, complete job.
184Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming toIS:8931. 15mm nominal bore
185Providing and fixing wash basin withC.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste ofstandard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single15 mm C.P. brass pillar tapin C.P. brass with waste fitting as per IS
186Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end ) 32MM nominalbore.
187Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete.25mm nominal bore.
188Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screwsand washers complete.
189Providing and fixing stainless steel A ISI 304(18/8) kitchen sink as per I.S.13983 with C.I. Brackets stainless steel plug 40mm including painting of fittings and brackets cutting and making goods the walls wherever required: kitchen sink without drain board,610x510mm bowel depth 200mm
190Providing and fixing unplasticisedP.V.C. connection pipe with c.p. nuts collar and bush of approved quality. 15mm nominal bore with 45 cm length.
191Providing And fixing 32 mm waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible Pipe
192Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (ITEM FOR RAIN WATER, SOIL, WASTE& VENTPIPES) 100 mm dia
193Providing & fixing on wall face unplasticised -P.V.C. moulde fittings / accessories for unplasticised -RigidP.V.C. rain water pipes conforming to IS: 13592 Type A including jointing withseal ring conforming to IS: 5382 leaving 10mm gap for thermalexpansion .Coupler -110 MM
194Single pushfit Coupler - 110 MM
195Single tee with door - 110X110X110MM
196Single tee without door -110X110X110 MM
197Bend 87.5° - 110 MM
198SHOE- 110 MM
199Nahani Trap- 110X75 MM
200Multitrap- 110X100 MM
201Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes joining of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I.(Approved Brand - ASTRAL/ SUPREME) Concealed work including cutting chases and makinggood the wall etc..15 mm nominal dia Pipes
20220 mm nominal dia Pipes
203Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes joining of pipes & fittings with one step CPVC solvent cement & testing of joints complete as per direction of E/I. (Approved Brand -ASTRAL) Exposed on Wall25 mm nominal dia Pipes
20432 mm nominal dia Pipes
205Providing and laying non- pressure NP2 class ( light duty ) R.C.C. pipes with collars jointed with still mixture of cenent mortar in the proportion of 1:2 ( lcement : 2 fine sand ) including testingof joints etc. complete.150 MM dia R.C.C. pipe
206250 MM dia R.C.C. pipe
207ate 20 mm nominal size) foundation con
208Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittingsand the base support for tank.
209Providing and fixing C.P. brass Health Faucet with 8mm dia. 1.20m long flexible tube & wall hook. Hand Shower-CAT. NO. - JAQUAR, ALD - 573
210Providing and fixing C.P. Towel Ring (round) with flange. Towel Ring -CAT. NO. - JAQUAR, AQN - 7721
211Basic rates for 125/ 115 mm dia drilled tube-well for drilling in all kinds of soil and rock for installation of hand pump with DTH rig machine all complete including supply all materials, labours, tools, drilling, rigs, air compressor and equipments as well as fuel lubricant, for making 125/115 mm dia boring etc.and cost of transporting rig machine and other vehicle up to site of work as per specification and direction of E/I.(a) From 0.00 M to 30.00 M below G.L
212(b) From 31.00 M to 60.00 M
213Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in- charge. 100 mm dia nominal size
214Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
215Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewellof: 100 mm Dia.
216Providing and fixing M.S. clamp of required dia to the top of casing/housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.100 mm clamp
217Supplying 100mm dia. Submersible pump sets confirming to IS 8034 and motor cvonfirming to IS 9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft ant polypropylene/ norylimpeller. Motor suitable for working on 415 V+10%, 3PH, 50 HZ, AC supply with cable guard, thurst carbon/ fibre bearing to withstand entire hydraulic thrust, water proof winding shall be provided. The pump set shall be suitable for direct coupling.Pump shall have suitable outlet as permanufacturers design. Anti thrust stream lined no return valve shall be provided with pump. 3 m submersible copper conductor cable in single/ double run and nylon rope as required length shall be provided with each pump. Submersible pump set 100mm dia (with polypropylene/ Noryl Impeller) upto 20 stages. 2HP.
218Supplying and fitting of standared make starter pannel board with arrangement of all necessory protection ,including all taxes , royalty etc all complete job as per direction ofE/I
219Supplying ,fitting & fixing & connecting 3 core 4 sqmm flat copper submerssible cable of Finolex / Hevels make including all taxes ,royalty etc allcomplete job as per direction of E/I
220Supplying and laying /lowering of GI pipe of 50 mm dia including of required fittings solvent etc complete job as perdirection of E/I
221LOCAL SAND , LEAD - 4 KM + 1KM
222STEEL & CEMENT , LEAD - 5 KM
223STONE CHIPS , LEAD - 22 KM + 3KM(KATCHA ROAD)
224BRICKS , LEAD-= 7 KM. + 1 KM(KATCHA ROAD)
225ADD GST @18%
226ADD LABOUR CESS @1%

AI Tender Summary

OUR REF NO 34830369
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 22-11-2022
Authority
Authority Name Urban Development Department
Work Description Construction Of Modern Crematorium At Chirkunda Nagar Parishad
Basic Detail
Tender No CNP/SBD/05/2022-23
Bidding Type Tender
Location
City chirkunda
State Jharkhand
Key Dates
Publish Date 20 Nov 2022
Submission Date 22 Nov 2022
Open Date 23 Nov 2022
Finance
Tender Value Ref. Documents
Tender Fee 10000
EMD 2.93 Lakhs
Exemption Not Available
Document List
f2938bc1-cf5f-41de-9393-89d12b58ddfd.html
BOQ_84752.xls
sbdcrem.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 20, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 22, 2022
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Nov 22, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Nov 23, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

f2938bc1-cf5f-41de-9393-89d12b58ddfd.html

xls

BOQ_84752.xls

pdf

sbdcrem.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail