Tender For Provision Of Walk In Cooler And Shadowless Led Lights For Operation Theatres With Allied Internal Electrification Works At Mh Under Ge Stm Chennai, chennai-Tamil Nadu

Military Engineer Services-MES has published Tender For Provision Of Walk In Cooler And Shadowless Led Lights For Operation Theatres With Allied Internal Electrification Works At Mh Under Ge Stm Chennai. Submission Date for this Tender is 03-12-2022. Electrification Work Tenders in chennai Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

34824880
Corrigendum : Tender For Provision Of Walk In Cooler And Shadowless Led Lights For Operation Theatres With Allied Internal Electrification Works At Mh Under Ge Stm Chennai
Open Tender
Indian
Tamil Nadu
chennai
03-12-2022

Tender Details

Provision Of Walk In Cooler And Shadowless Led Lights For Operation Theatres With Allied Internal Electrification Works At Mh Under Ge Stm Chennai

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-Nov-2022 Technical Bid corrigendum Technical Bid 26-11-2022
2 26-Nov-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-12-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 78000.0 /-
Tender Value
INR 39 Lakhs /-

BOQ Items

Name of Work: PROVISION OF WALK IN COOLER AND SHADOWLESS LED LIGHTS FOROPERATIONTHEATERS WITH ALLIED INTERNAL ELECTRIFICATION WORKS AT MH UNDER GE STM CHENNAI
Sl. No. Item Description
1BOQUPLOADED ON 15 NOV 2022: WALK IN COOLER Supply, installation, testing and commissioning of Walk - in-Cooler cold roomfor Medical Storage ofsize 12"0" x10 0" "x8"0" (Outer to outer Dimensions)consisting of wall and ceiling panel made out of Pre painted GI sheet filled with 60 mm PUF insulation, anti skid GI flooring on 60 mm PUF, with one door of size 900 mm X 2000mm , hydraulic door closer, digital temperature indicator, Air cooled medium temperature split unit of 3 HP rating with Hermetic/Scroll Compressors working on R -22/R - 410A refrigerants to maintain temperature of 4+/- 2 degree Centigrade at an ambient temperature of 30 degree centigrade all as specified and as directed by Engineer in Charge with following ;-.(ii) Room temperature - 4+/- 2 degree Centigrade (iii) Refrigeration system - Refrigerant R-22 or R-404A Split type & air cooled.(iv)Nos of refrigeration systems -TWO (one stand by) (v) Total refrigeration capacity -20,000 BTU /Hr (vi) Compressor type -Scroll, or Hermetic (v) Digital temperature indicator cum controller(vi) Refrigeration units microprocessor controller -02 Nos(vii)Indoor unit chamber with microprocessor controller -02 Nos(viii)Wall insulation -60 mm thick PUF Insulated panels with prepainted GI inside & out side finish & Anti Skid Flooring (ix) Floor insulation-60 mmthick PUF insulated anti skid flooring (x) Door Size & Type -60mm thick PUF Insulated (900mmX2000mm) Manual type swing door with PP inside & Outside finish(xi)Suitable light arrangement shall be provided as per trade practice . Note:- (i)The installation of Walk in cooler shall be carried out under supervision of manufacturer auth rep.(ii)Cost for any civil work i.e. foundation and any minor nature of work as requiredfor installation of walk in cooler at the existing building shall deemed to be in included in quoted rate.(iii)The cost of Comprehensive warranty/product warranty shall deemed to be in included in quoted rate. Note : The make of Walk in cooler shall be any one of the makes given in PS as approved by GE to suit the site condition.
2Supply and fixing four pole MCCB 63 Amps with breaking capacity 16 KA 415 volts fixing to the existing LT panel board inclduing necessary modification to existing LT Panel Board of CRCA sheet to match with existing size and height complete all as specified and as directed.
3Excavating in trenches not exceeding 1.5 metre wide and not exceeding1.5 metre in depth for foundation of stays, laying cables etc and getting out in hard/dense soil all as specified and as directed.
4Labour only for spread in trenches, sieving sandretrived from excavated soilincluding cleaning,spreading, levellng, punning for laying /cushioning of cable all as specified and as directed. Note:Punning thickness shall be measured and paid.
5Removing excavated material/ surplus soilnot exceeding 50 metres and depositing where directed at a level not exceeding1.5 metre above the starting point all as directed.
6Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cmusing excavated soil all as specified and directed.
7Supplying and laying reinforced precast concrete cable cover, class LV, Type 1, flat, size 250 mm x 150mm x 40mm all as specified and a directed by Engineer in Charge.
8Material & Labour for GI tubing "Light grade"of size 50mm bore for cable protection/ earth strip protection with all fittings and laid in trench or laid in floor all as specified and as directed by Engineer in Charge
9Supplying, laying, connecting, testing and commissioning of XLPE insulated, sheathed, screened, PVC bedded with galvanised steel strip or wire armoured electrical power cable with multi stranded aluminium conductor 1100 volts grade of earthed system all as specified forsize of cable 35 sqmm 4 core all as specified and a directed by Engineer in Charge.
10Supply& Fixload line distribution board, TPN vertical, 4 way double door type, fixed on wall semi flush, with incoming MCCB 4 poles 63 Amps, 16 KA bus bars, neutral link, blanking plates complete all as specified and as directed.
11Supply& Fixconnecting and testing MCB three pole and neutral (MCB TPN) 440 volts of capacity 63 Amps, 10 KA C curve complete all asspecified and as directed.
12Supply& Fixconnecting and testing MCB three pole and neutral (MCB TPN) 440 volts of capacity 32-40 Amps, 10 KA C curve complete all asspecified and as directed.
13SHADOWLESS LIGHT Supply and installation ofShadow less light fitting double dome complete with emergency power unit & battery back up for min 30 minutes (3 KVA), having dome of minimum 700mm dia, fully counter balanced moveable on ceiling trolley having a minimum longitudinal travel of 1350 mm and axial rotation of 360 deg. The unit to be suitable for operation on 230 V, single phase 50 cycles mains supply, OT light shall be provided with drip free spring arms for easy maneuverability , total lateral viewing of the patient as well as 360? rotation in main arm and light head for Major Operation Theater with following specification:-(a) Type of Ceiling OT Light :Double Dome (b) Diameter of lamp Head for main dome in mm with tolerance ±20 mm : 700(c) Diameter of Auxiliary dome in mm with tolerance±20 mm : 700(d) Range of Light Intensity in Luminous at 1 meter distance :160000 + 160000 (First auxiliary dome) + 160000 (Second auxiliary dome) (e) Range of Colour Temperature in Kelvin: 3800-4800 (f) Power Supply : 220 V , 50 Hz Single Phase (g) Life Span of LED in hours : 50000 (h) Range of Illuminated field diameter in mm : 200-400 (j) Colour rendering index (CRI) : 95 (k) Type of Control Panel :Manual and Touch Screen (l) Type of Lamp head : LED Single non winged round shape lamp head without any slots for easy maintenance and better sealing against dust and fumigation all as specified and as directed (m) Battery backup : minimum 30 minutes to 1hr Note : (i) Theinstallation of shadow less light fitting shall be done under the supervision of manufacturers auth rep. (ii) Comprehensive warranty for 01 year from the date of completion and product warranty for 5 years shall be covered & deemed to be in quoted rates. (iii) The make of light fitting shall be any one of the makes given in PS as approved by GE to suit the users requirement.
14Supply and installation ofShadow less light fitting single dome complete with emergency power unit & battery back up for min 30 minutes (3 KVA), having dome of minimum 700mm dia, fully counter balanced moveable on ceiling trolley having a minimum longitudinal travel of 1350 mm and axial rotation of 360 deg. The unit to be suitable for operation on 230 V, single phase 50 cycles mains supply, OT light shall be provided with drip free spring arms for easy maneuverability , total lateral viewing of the patient as well as 360? rotation in main arm and light head. For Minor OT with following specification:-(a) Type of Ceiling OT Light :Single Dome (b) Diameter of lamp Head for main dome in mm with tolerance ±20 mm : 700 (c) Diameter of Auxiliary dome in mm with tolerance±20 mm : 700 (d) Range of Light Intensity in Luminous at 1 meter distance :160000 (e) Range of Colour Temperature in Kelvin: 3800-4800 (f) Power Supply : 220 V , 50 Hz Single Phase (g) Life Span of LED in hours : 50000 (h) Range of Illuminated field diameter in mm : 150-400 (j) Colour rendering index (CRI) : 93 to 95 (k) Type of Control Panel :Manual and Touch Screen (l) Type of Lamp head : LED Single non winged round shape lamp head without any slots for easy maintenance and better sealing against dust and fumigation (m) Battery backup : minimum 30 minutes to 1hr Note : (i) Theinstallation of shadow less light fitting shall be done under the supervision of manufacturers auth rep. (ii) Comprehensive warranty for 01 year from the date of completion and product warranty for 5 years shall be covered & deemed to be in quoted rates. (iii) The make of light fitting shall be any one of the makes given in PS as approved by GE to suit the users requirement.
15Supply& Fix Sheet metal enclosure for MCB DB single pole and neutral 240 volts, double door, 8 way with 200 amps rated bus bar all as specified and as directed by Engineer in Charge
16Supply& Fix MCB single pole 240 volts, 6 to 32 amps all as specified and as directed by Engineer in Charge
17Supply& Fix RCBO single pole & neutral, 240 volts, 40 amps, 30mA, 10kA all as specified and as directed by Engineer in Charge
18Material & Labour for sub main wiring with PVC insulated, 1100 volts grade single core multistranded copper conductor cable conforming to IS specifications, 2 runs of 6 sqmm including one run of6 sqmmsingle core multistranded copper conductor PVC insulated cables as earth continuity conductor drawn through and including one run of 25 mm dia rigid PVC conduit and conduit accessories fixed on wall/ceiling etc., or concealed in wall, making good disturbed surfaces of walls and connecting to common earth dolly all as specified and as directed. Note : Two runs of 6 sqmm cable, one run of 6 Sqmm cable for earthingand one run of 25 mm dia PVC conduit shall be considered as one unit of Running meter