| 1 | Supply, erection, testing and commissioning of 33KV OIL COOLED DEAD TANK CURRENT TRANSFORMER(800-400-200/1-1-1,BURDEN:30VA,CLASS:-PS-0.2S-PS) (3 secondary cores) along with both side primary terminal\"sconductor clamp for moose conductor. Including body earthing with 50 mm GI flat upto nearest Earth Pit (5 Mtr) andall accessories like nuts, bolts ,washers etc. as per instruction and requirement. |
| 2 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 11.00 metre and upto 13.00 metre |
| 3 | Supply and errection of a set of 2x4.5 mtr channel iron 100 mm X 50 mm X 6 mm (9.56 kg/m), pole top bracket for 4.5 mtr wide Dipole, to fit 33 kV disc and33 KV over head line conductor complete with 50 mm X 6 mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc to make a four pole structure and base arrangement of AB switch and painting with primer and finish paint as required. For make a four pole structure and base arrangement of AB switch |
| 4 | Supplying and erection of a set of cross bracing frame work for 33 KV over head line double pole structure having four members fabricated out of 65 mm X 65 mm X 6 mm (5.8 Kg/ Mtr)angle iron to form a rectangle of minimum size 4500 mm width X 3000 mm height complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts, washers etc and painting with primer and finish paint as required. for making four pole structure |
| 5 | Supplying and erection of 33KV Polymer Disc Insulator (70KN) for 33 KV over head lines with galvanised insulator hardware fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required |
| 6 | Supplying and erection of 33 KV Polymer Pin Insulator (10 KN) for 33 KV over head lines along with bolts, nuts, washers etc. as required |
| 7 | Supply and erection of 33 kv Post Insulators on existing structure with conductor clamps suitable to hold33 KV Moose Conductor above the Insulator. Including nut bolts, washers an all accessories as per site requirement. |
| 8 | Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, bow tightener, 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominalsize ) foundation including excavation and refilling etc. as required. |
| 9 | Supply and Erection of single piece nonlinear resistor type lightning arrestor suitable for 3 wire, 33 KV overhead lines with rated voltage 36 KV (rms) with a nominal discharge current rating of 10 KA (station class) and complete with base arrangement, galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required. |
| 10 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.with charcoal/coke and saltas required. Details of cost for one Set |
| 11 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 12 | Erection of 19/2.63 core/mm Dog conductor (1 KM=394 KG) 600 meter= 236.4Kgincluding binding, Temination by supplying Alluminium Lugs , GI Nut Bolts etc. as per requirement. |
| 13 | Supply of19/2.63 core/mm Dog conductor(125 sq mm) |
| 14 | Supply Errection and connection of Isolator Pad Clamp (For Moose Conductor) along with all GI nut bolts washer as per instruction and site requirement. |
| 15 | Supply and erection, allignmentand commissioning of 33KV 1200Amp Double Break GOAB Switch Horizontal Type in 33Kv Dipole Structure along with conductor termination at both side and base earthing (Including all materials like nuts, bolts, washers as required) |
| 16 | Supply, erection, allignmentand commissioning of 36kV, 1250Amps, 25kA for 1 sec, Triple pole, Horizontal Double Break, motor (3-? ,415V, 50Hz, AC, Control voltage 220V DC,Remote-Local-Manual) operated isolator with insulator (6KN, CD-25mm/KV) and Terminal connector suitable for ACSR Moose conductor, without Earth switch. in existing structure along with moose conductor termination at both side (Including power and control cable termination by supplying suitable glands, lugs ferrules and all materials like nuts, bolts, washers as required) including body earthing with 50 mm GI flat upto nearest Earth Pit (5 Mtr) |
| 17 | Supply, erection, allignmentand commissioning of 36kV, 1250Amps, 25kA for 1 sec, Triple pole, Horizontal Double Break, motor (3-? ,415V, 50Hz, AC, Control voltage 220V DC, Remote-Local-Manual) operated isolator with insulator (6KN, CD-25mm/KV) and Terminal connector suitable for ACSR Moose conductor, With One Earth Switch -manual operated. in existing structure along with conductor termination at both side (Including power and control cable termination by supplying suitable glands, lugs ferrules and all materials like nuts, bolts, washers as required) |
| 18 | Supply retrofit, testing and commissioning of Numerical feeder protection relays as per the Specifications (Anexure-I) in existing 33KV Control and Relay Panels along with all materials like phenolic sheet, metal plates, wires, screws etc. as per design and site requirements |
| 19 | Supply, retrofit, testing and commissioning of HT CT operated Three phase Trivector Meter (Accuracy class 0.2s, Bsic Current 1 Amp, PT Supplly 110V (L-L), 63.5V(L-N) , 3 Phase4 wire ) as per IS 14697/CBIP 88 in the 33KV control and relay Panels, along with all materials as per design and site requirements |
| 20 | Supply, retrofit, testing and commissioning of Multifunction meter(Three Phase)of size 96x96x50mm in the 33KV control and relay Panels, along with all materials as per design and site requirements |
| 21 | Supply, retrofit, testing and commissioning of 4 windows annunciator fascia (Control voltage 220v DC) medium size window in the 33KV control and relay Panels, along with all materials as per design and site requirements |
| 22 | Supply, retrofit, testing and commissioning of LED based Semaphore Indicator(29MM), in the 33KV control and relay Panels, along with all materials as per design and site requirements |
| 23 | Supply, retrofit, testing and commissioning of LED based Semaphore Indicator(50mm), in the 33KV control and relay Panels, along with all materials as per design and site requirements |
| 24 | Supply installation, connection and commissioning of AC CONSOL Box made of 1.6mm thick sheet steel enclosure duly painted with powder coating of Size (LxBxH - 1200x650x500 mm) fitted with 100 A MCCB and 3 phase Neutral alluminium Bus Busbar, and 08 nos 16/25 ADipole Class-CMCBs..and wired with suitable rated cupper wire. including glanding and termination and base arrangement. |
| 25 | Supply fixing, connection and commissioning of Current Transformer Marshalling box of dimenssion (LxBxH- 320x240x180mm ) fitted with 32 numbers of Disconnectiong Terminal block suitable for CT cable. Along with all materials as per requirement .including glanding and termination and base arrangement. |
| 26 | Supply, laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formationthe trench etc as required, but excluding sand cushioning and protective covering. for 2cX2.5 sq mm Cupper Armoured power cable 1.1 KV Grade, along with all material as per design and requirement. |
| 27 | Supply, laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation the trench etc as required, but excluding sand cushioning and protective covering. For 3cX2.5 sq mm CupperArmoured power cable 1.1 KV Grade, along with all material as per design and requirement. |
| 28 | Supply and Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation the trench etc as required, but excluding sand cushioning and protective covering. For 4cX10 sq mm Alluminium Armoured power cable 1.1kV Grade along with all material as per requirement and design. |
| 29 | Supply, laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation the trench etc as required, but excluding sand cushioning and protective covering. For 4cX4 sq mm CupperArmoured power cable.1.1 Kv Grade, along with all material as per design and requirement. |
| 30 | Supply, laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation the trench etc as required, but excluding sand cushioning and protective covering. For 7cX4 sq mm Cupper Armoured power cable, 1.1 KV Grade, along with all material as per design and requirement. |
| 31 | Supply, Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation the trench etc as required, but excluding sand cushioning and protective covering. For 8cX2.5 sq mm Cupper Armoured Control cable 1.1 KV Grade, along with all material as per design and requirement. |
| 32 | Supply, laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formationthe trench etc as required, but excluding sand cushioning and protective covering. For 10cX2.5 sq mm Cupper Armoured Control cable 1.1 KV Grade, along with all material as per design and requirement. |
| 33 | Supply, Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formationthe trench etc as required, but excluding sand cushioning and protective covering. For 12cX2.5 sq mm Cupper Armoured Control cable 1.1 KV Grade, along with all material as per design and requirement. |
| 34 | Supplying and making end termination with brass compression gland and Cupperlugs for following size of PVC insulated and PVC sheathed / XLPE Cupperconductor cable of 1.1 KV grade as required including lugs, glands and all materials as per requirement. for 2cX2.5 sq mm, 3cX2.5 sq mm & 4cX4 Sq mm Cables. |
| 35 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required including lugs, glands and all materials as per requirement. for 7cX2.5 sq mm, 8cX2.5 Sq mm & 4cX10 sq mm |
| 36 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required including lugs, glands and all materials as per requirement. for 10cX2.5 sq mm & 12cX2.5 sq mm cable. |
| 37 | Repairing of BHEL makePVN 36, 33 KV VCB by Supplying of 33KV VCB Pole (03 numbers in each VCB) , 01 Closing Coil, 01 Tripping Coil, 01 Local- Remote Switch, 01 Antipumping Coil, 01 T-N-C Switch(2NO+2NC), 04 numbers of Catridge fuses with base (16A) , 02 numbers of Push buttons,switches, Spring Charging Motor, Operating Counters, Auxilary contactsalong with all materials like ferul, control wires, glands, lugs, Termiinal Blocks switable for Ring lugs(32A) etc anddismantaling of the damaged pole in an existing 33KV VCB |
| 38 | Repairing of 33KVControl & Relay Panelby Supplying 04 numbers Breaker Contro Switch (T-N-C Switch), Catridge Fuses with base (08 numbers), Terminal Block switable for ring lugs(45A) (50 numbers) with DIN Rail, 02 Push button switches, 06 Indication Lamps, control wires etc. including cutting and retrofitting as per requirement. |
| 39 | Total impact of GST for the purpose of CTC |