| 1 | Taking down feeder pillar/LT Panels any type and capacity alongwith all accessories including disconnect electric supply from Bus bars to Transformer , disturbed surface and match with existing complete all as specified and directed |
| 2 | Supply, installation, commissioning and testing in replacementof feeder pillar box kiosktype, factory made, CPRI approved ,LT(415 Volts, 50 Hz , 3-phase, 4 wire supply) duly mounted on iron leg of size50x50x6mm,Indoor type,double door,weather and vermin proof (Protection Class IP-54),with ventilation louvers and 2.0 mm thickMS CRCA sheet and angle iron frame work with both side hinged opening for external, rubber lining, locking arrangement, Powder Coated externally and internally over a coat of red oxide primer complete including grouting of frame with PCC mortor for installation of panel of following : - (At SW No-1,5&7) |
| 3 | (a)Bus Bar chamber comprising 4 Nos Copper strip bus bars air insulated and PVC sheathed, capacity not lesss than 100 Amp with colour coding in separate sheet steel enclosure. |
| 4 | (b) MCCBs for Motor back- up protection415 Volts, 63 Amp rating4 Pole,thermal adjustable type, Service Breaking Capacity 50 kA, Model No-DZ1 160 N of L&T -1 No |
| 5 | (c) LED indicating lamp ( Colours- Red,Yellow & Blue ) Set of One - One No |
| 6 | (d) Panel mounted Digital Voltmeter 0-500 V, three phase,96mm X 96 mm square flush mounted-1 No |
| 7 | (e) Panel mounted Digital Ammeter ,0-100 Athree phase,, 96mm X 96 mm square flush mounted with suitable ratio of CTs-1 No |
| 8 | (f) Rotary Switches - 02 Nos |
| 9 | (g) On load change over switchof capacity 63 Amps 4 Pole 415 Volts - 01 No |
| 10 | Out Going :- (a) MCCBs for Motor back- up protection415 Volts, 40 Amp rating3 Pole,thermal adjustable type, Service Breaking Capacity 50 kA, Model No-DN0 100M of L&T-02 Nos |
| 11 | (b) MCB TP C curve, 415 Volts, 40Amp rating-2 Nos |
| 12 | (c) Automatic Star delta starter for 10 HP,12 HP &15HP electric timer relay, provn indicating facility for Low/High voltage, Phase reversing, Low Level of Water, High Temparature, Pump running, Over Load Trip, Contamination (Moisture) and Manual Start, Manual Stop, Moisture Reset with indicators etc complete all as specified and directed-02 Nos (Each Capacity of HP) |
| 13 | (d) Panel mounted Digital Ammeter ,0-100 Athree phase,, 96mm X 96 mm square flush mounted with suitable ratio of CTs-2 Nos |
| 14 | (e) Internal wiring with multistranded copper conductor cable / PVC Insulated copper Strip of suitable size lugs, Washers, Nut& Bolts incoming to bus bar and bus bar to outgoing MCCB/MCB-1Job. |
| 15 | (f) Internal wiring with single core copper conductor cable with suitable lugs, Washers, Nut& Bolts for instruments/indicating lamps-1 Job. |
| 16 | (g) LED indicating lamp ( Colours- Red,Yellow & Blue ) Set of one - 02 Nos Note :-MCCBs should be connected with spreader terminalsof suitable size. |
| 17 | Supply, installation, commissioning and testing in replacementof feeder pillar box kiosktype, factory made, CPRI approved ,LT(415 Volts, 50 Hz , 3-phase, 4 wire supply)duly mounted on iron leg of size50x50x6mm,Indoor type,double door,weather and vermin proof (Protection Class IP-54),with ventilation louvers and 2.0 mm thickMS CRCA sheet and angle iron frame work with both side hinged opening for external, rubber lining, locking arrangement, Powder Coated externally and internally over a coat of red oxide primer complete including grouting of frame with PCC mortor for installation of panel of following : - (At SW No-2& 4) complete all as specified and directed. |
| 18 | (a)Bus Bar chamber comprising 4 Nos Copper strip bus bars air insulated and PVC sheathed, capacity not lesss than 300 Amp with colour coding in separate sheet steel enclosure. |
| 19 | (b) MCCBs for Motor back- up protection415 Volts, 160 Amp rating4 Pole,thermal adjustable type, Service Breaking Capacity 50 kA, Model No-DZ1 160 N of L&T -1 No |
| 20 | (c) LED indicating lamp ( Colours- Red,Yellow & Blue ) - Set of one |
| 21 | (d) Panel mounted Digital Voltmeter 0-500 V, three phase,96mm X 96 mm square flush mounted-1 No |
| 22 | (e) Panel mounted Digital Ammeter ,0-200 Athree phase,, 96mm X 96 mm square flush mounted with suitable ratio of CTs-1 No |
| 23 | (f) Rotary Switches - 02 Nos |
| 24 | (g) On load change over switchof capacity 160 Amps 4 Pole 415 Volts |
| 25 | Out Going :- (a) MCCBs for Motor back- up protection415 Volts, 80 Amp rating3 Pole,thermal adjustable type, Service Breaking Capacity 50 kA, Model No-DN0 100M of L&T-03 Nos |
| 26 | (b) MCB TP 415 Volts, 80 Amp rating-3 Nos |
| 27 | (c) Automatic Star delta starter for 35 Hp electric motor including Contators, timer, relay, provn indicating facility for Low/High voltage, Phase reversing, Low Level of Water, High Temparature, Pump running, Over Load Trip, Contamination (Moisture) and Manual Start, Manual Stop, Moisture Reset with indicators etc complete all as specified and directed - 03 Nos |
| 28 | (d) Panel mounted Digital Ammeter ,0-100 Athree phase,, 96mm X 96 mm square flush mounted with suitable ratio of CTs-3 Nos |
| 29 | (e) Internal wiring with multistranded copper conductor cable / PVC Insulated copper Strip of suitable size lugs, Washers, Nut& Bolts incoming to bus bar and bus bar to outgoing MCCB/MCB-1Job. |
| 30 | (f) Internal wiring with single core copper conductor cable with suitable lugs, Washers, Nut& Bolts for instruments/indicating lamps-1 Job. |
| 31 | (g) LED indicating lamp ( Colours- Red,Yellow & Blue ) Set of one - 03 Nos Note :-MCCBs should be connected with spreader terminalsof suitable size. |
| 32 | Supply, installation, commissioning and testing in replacementof feeder pillar box kiosktype, factory made, CPRI approved ,LT(415 Volts, 50 Hz , 3-phase, 4 wire supply)duly mounted on iron leg of size50x50x6mm,Indoor type,double door,weather and vermin proof (Protection Class IP-54),with ventilation louvers and 2.0 mm thickMS CRCA sheet and angle iron frame work with both side hinged opening for external, rubber lining, locking arrangement, Powder Coated externally and internally over a coat of red oxide primer complete including grouting of frame with PCC mortor for installation of panel of following : - (At SW No-3&6) complete all as specified and directed. |
| 33 | (a)Bus Bar chamber comprising 4 Nos Copper strip bus bars air insulated and PVC sheathed, capacity not lesss than 200 Amp with colour coding in separate sheet steel enclosure. |
| 34 | (b) MCCBs for Motor back- up protection415 Volts, 125Amp rating4 Pole,thermal adjustable type, Service Breaking Capacity 50 kA, Model No-DZ1 160 N of L&T -1 No |
| 35 | (c) LED indicating lamp ( Colours- Red,Yellow & Blue ) - Set of one |
| 36 | (d) Panel mounted Digital Voltmeter 0-500 V, three phase,96mm X 96 mm square flush mounted-1 No |
| 37 | (e) Panel mounted Digital Ammeter ,0-200 Athree phase,, 96mm X 96 mm square flush mounted with suitable ratio of CTs-1 No |
| 38 | (f) Rotary Switches - 02 Nos |
| 39 | (g) On load change over switchof capacity 125Amps 4 Pole 415 Volts |
| 40 | Out Going :- (a) MCCBs for Motor back- up protection415 Volts, 63 Amp rating3 Pole,thermal adjustable type, Service Breaking Capacity 50 kA, Model No-DN0 100M of L&T-03 Nos |
| 41 | (b) MCB TP 415 Volts,63 Amp rating-3 Nos |
| 42 | (c) Automatic Star delta starter for 30 Hp electric motor including Contators, timer, relay, provn indicating facility for Low/High voltage, Phase reversing, Low Level of Water, High Temparature, Pump running, Over Load Trip, Contamination (Moisture) and Manual Start, Manual Stop, Moisture Reset with indicators etc complete all as specified and directed - 03 Nos |
| 43 | (d) Panel mounted Digital Ammeter ,0-100 Athree phase,, 96mm X 96 mm square flush mounted with suitable ratio of CTs-3 Nos |
| 44 | (e) Internal wiring with multistranded copper conductor cable / PVC Insulated copper Strip of suitable size lugs, Washers, Nut& Bolts incoming to bus bar and bus bar to outgoing MCCB/MCB-1Job. |
| 45 | (f) Internal wiring with single core copper conductor cable with suitable lugs, Washers, Nut& Bolts for instruments/indicating lamps-1 Job. |
| 46 | (g) LED indicating lamp ( Colours- Red,Yellow & Blue ) Set of one - 03 NosNote :-MCCBs should be connected with spreader terminalsof suitable size. |
| 47 | Taking up cast iron water mains (including all fittings)250 mm bore, with flanged ends complete. |
| 48 | Taking up cast iron water mains (including all fittings)150 mm bore, with flanged ends complete all as specified and directed. |
| 49 | Taking up cast iron water mains (including all fittings)100 mm bore, with flanged ends complete all as specified and directed. |
| 50 | Supply and laying Cast iron pipes with flanged ends/ verticaliy cast, Class A, 250 mmdia (Suction Pipe) complete all as specified and directed. |
| 51 | Supply and laying Cast iron pipes with flanged ends/ verticaliy cast, Class A, 150 mmdia (Suction Pipe) complete all as specified and directed. |
| 52 | Supply and laying Cast iron pipes with flanged ends/ verticaliy cast, Class A, 100 mmdia (Suction Pipe) complete all as specified and directed. |
| 53 | M&L CI/DI fittings for spigot socketed end pipe uptosize 150 mm bore Bends (any type, radius andangle) tapers any type,(straight, bend, increasing,decreasing or double socket etc.)Tee pieces single branch. \"Y\"junction, double branch, cross(all sockets or socket and spigot) collars, caps and plugs (joints, excavation andearth work shall be measured and paid separately) |
| 54 | Supply, layingand jointing cast iron sluice valve of class PN-1.6 IS-14846 marked 250 mm bore with brass spindle, & cast iron wheel having both flanged and drilled ends including rubber gasket, nut bolt andwasher heavy duty 16mm dia etc and including taking down complete all as specified and directed. |
| 55 | Supply, layingand jointing cast iron sluice valve of class PN-1.6 IS-14846 marked 150 mm bore with brass spindle, & cast iron wheel having both flanged and drilled ends including rubber gasket, nut bolt andwasher heavy duty 16mm dia etc and including taking down complete all as specified and directed. |
| 56 | Supply, layingand jointing cast iron sluice valve of class PN-1.6 IS-14846 marked 100 mm bore with brass spindle, & cast iron wheel having both flanged and drilled ends including rubber gasket, nut bolt andwasher heavy duty 16mm dia etc and including taking down complete all as specified and directed. |
| 57 | S&F Non return Valve class PN-1.6, heavy grade with by pass arrangement 250 mm dia complete all as specified and directed |
| 58 | S&F Non return Valve class PN-1.6, heavy grade with by pass arrangement 150 mm dia complete all as specified and directed |
| 59 | S&F Non return Valve class PN-1.6, heavy grade with by pass arrangement 100 mm dia complete all as specified and directed |
| 60 | M&L construction of brick masonry valve pit of size 1200 mmX 1200mm X 1200mm(internal dimensions of chamber)depth to be reckoned from the top ofPCC in foundation to top of MS cover with MS sheet cover 3mm thick including frame of angle iron 40 X 40 X 6 mm with locking arrangement and lifting handle including painting two coats of black synthetic enamel paint over a coat of red oxide primer etc including brick work in one brick thick wall in cement mortar 1:4, 15mm thick plastering in cement mortar 1:4 (internally on all brick wall and external upto 15cm below ground level) and necessary excavation and earth work in any type of soil, returning, filling in, disposal of surplus spoil to a distance not exceeding 50 mtr 15 cm thick PCC 1:4:8 type D-2 in PCCfoundation projected by 15cm all round from the outer face of brick wall PCC 1:2:4 type B-1 in coping complete all as specified and directed.. |
| 61 | Taking out unsv mild steel covers of valve chambers and Supply and Fixing covers of valve chambers duly hinged fabricating the frame by using 3.15mm thick mild steel sheet and angle iron of size 40 mm X 40 mm X 6 mm thick including making locking arrangement and fixing the above cover in PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate and providing hold fast of appropriate size made to shape of 50mm x 6mm mild steel flat including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 62 | Earthing complete with galvanised mild steel earth plate electrode 600X600X6 mm thick buried directly in ground vertically (earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate electrode at a depth not less than 1.5m below normal ground level and including GI earth strip 32 x 6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate electrode at one end and connected to metallic bodies of HT/LT equipments etc at the other end, earth strip encased in and including 50 mm bore GI medium grade pipe with all fittings from top of earth plate electrode to body of equipment fixed with and including 25x 6mm flat iron clamps, bolts, nuts and washers and including providing watering pipe 20mm bore GI pipe medium grade from Bottom of concrete pit to top of earth plate electrode complete all as specified and shown in electrical plate No 3 of MES SSR Part-I. The scope of work includes necessary excavation and earth work in any type of soil, removal of soil upto 50 metre, PCC pit with precast RCC cover, charcoal/salt, funnel, CI frame etc complete all as specified and directed |
| 63 | Taking down carefully unserviceable point wiring (light,fans,socket etc) complete incl battens and fittings such as switch, ceiling rose,light fittings, regulatos, socket etc and making good disturbed surface of wall/floor etc complete all as specified and directed. |
| 64 | Taking down DB/main switch of any size and making good disturbed surface of wall/floor complete all as specified and directed. |
| 65 | Taking down sub main wiring of any size complete and making good disturbed surface of walls/floors etc complete all as specified and directed. |
| 66 | M & L for taking down fans ceiling/Exhaust cable ends dismantling blades and removing fan and keeping in safe custody for reuse. complete all as specified and directed. |
| 67 | Taking down old U/S light fittings any type and size complete all as specified and directed. |
| 68 | M & L for Point wiring for one light point with 1.5 sqmm PVC insulated and unsheathed copper conductor multistranded 1100 volts grade, ISI marking drawn thorugh and existing non metallic PVC rigid conduit and conduit accessories, medium grade, ISI marking, concealed with provn of modular metal flush box and Modular white Cover Plate with Frame for fixing switches, sockets, inculding one run of 1.5 sqmm PVC insulated unsheathed copper cableFRLS grade as in earth wire for continuity and connecting to earth dolly for one light point controlled by one switch completeincluding making good the disturbed surface by Putty and matching the colour of wall with the existing colour of the wall (wash/paint/distemper) wherever required(as per the existing condition)all as specified and directedNote -modular metal flush box and Modular white Cover Plate with Frame shall be measured and paid for seperately under relevent item. |
| 69 | All as per Ser item No.26above but for 5 amps socketon same board with other switches |
| 70 | All as per Ser item No.26above but for 5 amps socket on independent board. |
| 71 | All as per Ser item No.26 above but with 2.5 sqmm cables for 15 amps switch socket combination outlet on independent board complete all as specified and directed. |
| 72 | Supply and fix switch 5 amps switch flush type one way single pole. complete all as specified and directed. |
| 73 | Supply and fixsocketoutlet flush type multi pin 5 amps. complete all as specified and directed. |
| 74 | Supply and fix switch socket combination outlet universal type 5 pin 5/16 amps complete all as specified and directed. |
| 75 | Supply and fix ceiling rose surface backelite 65x50 mm having3 terminal. complete all as specified and directed. |
| 76 | Supply and fix ceiling fan regulator Electronic rotary Step type 80 wattsingle phase A/C 230 volts all complete as specified and directed |
| 77 | Supply and fix Circuit/Sub Main Wiring with 2x4.0 Sqmm PVC insulated, FRLS, copper cable 1100 volts grade stranded copper conductor cable drawn through and including PVC concealed conduit with all fittings and accessories including PVC box (IS-14772) and 1 X 4 Sqmm stranded PVC unsheathed copper cable for earth continuity connected to common earth dolly. complete all as specified and directed. |
| 78 | S & F Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), SPN, 240 volt, 8 Way, IP-42 protectionand suitable for having MCB’s complete and all disturbed surfaces of wallshall be made good to match the existing wall finishes all as specified and directed |
| 79 | Taking down old Unsv MCB/MCCB/RCBOs of any type & any capacity complete all as specified and directed |
| 80 | S & F MCB SP 5 to 32 Amp,C series , 230 Volts completeall as specified and directed . |
| 81 | Supply and fix, MCB SPN 240 volts, 10 KA, 50 Hz of capacity 6-32 Amps \"C\" Curve all as specified and directed. |
| 82 | Supply and fixing LED Security/street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 83 | M&L for Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 to the earthing test point all as specified and indicated including testing on completion etc complete all as specified and directed |
| 84 | Supply and Fixingin repairs wall mounted LED batten, polycarbonate housing & integrated electronic driver. LED light fittings flicker free, instant start with uniform light distribution 20W 4 ft indoor decorative with 2 Core copper wire from ceiling rose to light fitting . |
| 85 | S&F in replacement security light/bldg light with high power LED fitting as light source ,energy saving envoirmental friendly 30 W with advance features all as complete with fixing arrangement such as GIpipe brakets bend in 120 degree, clamps made out by GI strip suitable for steel or PCC poles, nuts ,bolts and washer to be fixing incl making all eclectrical connection with three core flexible copper cable etcspecified and directed. Make :CG, Model No-LDSTR30CDL |
| 86 | Supply and fixing iSupply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete |
| 87 | Materials and labour for hanging to ceiling fan as per exsiting andmaking all electric connection using three core PVC insulated copper conductor muilti strandard flexible cable drawn through in PVC flexible conduit pipe from fitting to ceiling rose including fan condensor and other spaires to beminior repair if required complete all as specified and directed |
| 88 | Material & Labour for GI pipe light grade 40 mm, suitable for bracket of street light fitting 1.2 mtrs long including MS flat iron clamp 25X3mm thick with nut bolt and washers for fixing in Pole and wall complete all as specified and directed. |
| 89 | Taking up or down old steel tubing 15 mm bore and connections from trench/floor/along wall including cleaning for refixing or removal from site (excavation and earth work shall be measured and paid for separately). complete all as specified and directed. |
| 90 | All as per srl item No. 47.00but GI tubing of size 20 mm bore. complete all as specified and directed. |
| 91 | Supply, Laying, jointing and testing galvanized iron tubes 15 mm bore medium gradewith all fittings confirming toIS-1239, laidalong wall or roofs and in floorsetc complete all as specified . |
| 92 | All as persrl item No. 49.00but of size 20 mm bore. complete all as specified and directed. |
| 93 | Supply and fix (in repair) Gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe 15 mm bore fixed in repair/replacement complete. |
| 94 | Description same as per srl item No.51.00but of size 20 mm bore. complete all as specified and directed. |
| 95 | Supply and fix Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed. |
| 96 | S&F Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed fancy type complete all as specified and directed. |
| 97 | Supply and fix 10 litres, cast iron, valveless. Syphonic action type, flushing cistern, high level, with inlet, ball valve, float, chain and pull, and brackets complete all as specified and directed |
| 98 | S&F PVC connections 15mm size with PTMT nuts of length 300mm complete all as specified and directed |
| 99 | S&F Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms) complete all as specified and directed |
| 100 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed |
| 101 | Taking down OHL ACSR existing size and type complete all as specified and directed. |
| 102 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3.5 core complete all as specified and directed |
| 103 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4.0 core complete all as specified and directed. |
| 104 | Material & Labour for fixing LED flood light luminaries of cap 120 watt external with lense, 240 volt,Pressure die cast housing with IP 66 protection,heat resistant toughtened clear glasswith frame complete with accessories , pre wired up to a terminal block including PVC insulated ,twin core,Aluminium conductor cable of size 1.5 sqmm and mounting attachment complete all as specified and directed. |
| 105 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core complete all as specified and directed. |
| 106 | M& L for making water level indicator from MS sheet of Size 4mX0.6mX3mm thick , with Copper float ball of size 300mm dia , Steel rope 10mm dia as required from tank to indicator including all necessary fabrication, welding works,MS angle ,MS flat, nut, bolts washerscompleteetc and duly marking the levelwith paint on MS with necessary pulleyarrangement includingoverhead tankcomplete all as specified and directed. |
| 107 | Excavation in trenches in soft / loosesoil n.exc 1.5 mtr deep and not exceeding 1.5 mtr in width for taking up / down underground water tubing, UG Cables andor laying of CI / GI pipes and UG Cables(new or old) of any dia/size and getting outcomplete all as specified and directed. |
| 108 | Excavation in trenches in hard / dense (in road cutting / plinth) soil n.exc 1.5 mtr deep and not exceeding 1.5 mtr in width for taking up / down underground water tubing, UG Cables andor laying of CI / GI pipes and UG Cables(new or old) of any dia/size and getting outcomplete all as specified and directed. |
| 109 | Returning filling with earth obtained from excavation including spreading, watering & consolidation in layers not exceeding 15 cms thick, complete all as specified and directed. |
| 110 | Removing surplus soil to a distance not exceeding 50 m & depositing at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 111 | Material & labourfor Sand filling in trenches with clean dry fine sand unwashed including gently punning around cables complete all as specified and directed. |
| 112 | Material & labour for un-reinforced precast concrete cable cover Class LV, Type I, flat, size 250 mm x 150mm x 40mm for cable protection complete all as specified and directed. |
| 113 | Material & labour for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate . in mass concrete and filling completefor foundation of Panel & Transformer yeard, pole/stay/ of poleall as specified & directed |