Tender For Upkeeping Elect Sub Station 33 Kv Mrs Various Em Installations And Rep Maint Of Bldg Security Light Fittings Lightening Conductors Earthing Aviation Flame Proof Elect Supply High Mast Lights Misc Elect Works South Side Runway Age Em I Of Ge, vasco-Goa

Military Engineer Services-MES has published Tender For Upkeeping Elect Sub Station 33 Kv Mrs Various Em Installations And Rep Maint Of Bldg Security Light Fittings Lightening Conductors Earthing Aviation Flame Proof Elect Supply High Mast Lights Misc Elect Works South Side Runway Age Em I Of Ge. Submission Date for this Tender is 12-12-2022. Electrification Work Tenders in vasco Goa. Bidders can get complete Tender details and download the document.




Tender Notice

34782722
Corrigendum : Tender For Upkeeping Elect Sub Station 33 Kv Mrs Various Em Installations And Rep Maint Of Bldg Security Light Fittings Lightening Conductors Earthing Aviation Flame Proof Elect Supply High Mast Lights Misc Elect Works South Side Runway Age Em I Of Ge
Open Tender
Indian
Goa
vasco
12-12-2022

Tender Details

Upkeeping Elect Sub Station 33 Kv Mrs Various Em Installations And Rep Maint Of Bldg Security Light Fittings Lightening Conductors Earthing Aviation Flame Proof Elect Supply High Mast Lights Misc Elect Works South Side Runway Age Em I Of Ge Nw Vasco 8486 / 22 / E8

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 05-Dec-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 12-12-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 99700.0 /-
Tender Value
INR 49.85 Lakhs /-

BOQ Items

NAME OF WORK : UPKEEPING OF ELECTRIC SUB STATION 33 KV MRS AND VARIOUS E/M INSTALATIONS OF SOUTH SIDE OF INS HANSA AND REPAIR / MAINTENANCES OF BLDG SECURITY LIGHT FITTINGS, LIGHTENING CONDUCTORS, EARTHING, AVIATION LIGHTS, FLAME PROOF ELECTRIC SUPPLY, HIGH MAST LIGHTS AND MISC ELECTRICAL WORKS FOR BLDGS AND HANGARS OF SOUTH SIDE RUNWAY UNDER AGE E/M - I OF GE (NW) VASCO
Sl. No. Item Description
1UPKEEPING OF ELECTRIC SUB STATION 33 KV MRS AND VARIOUS EM/M INSTALLATIONS OF SOUTH SIDE OF INS HANSA UNDER AGE E/M-I
2Material and Labour for graded coarse aggregate (broken stone or boulders) of size 40 mm in sub - station yard for layingall as directed and specified.
3Surface dressing not exceeding 15 cm depth by removing of creepers /vegetation on stay wires/ HT/LT /street light poles byclearing3 mtr all around Stay wire & pole soft and removing the loose soil all as directed. (Note : Each cleaning will be mesaured and paid)
4Dismantling of existing old unserviceable ACSR of any size from any descritpion, material and labour for providing new ACSR conductor all as specified and directed incl stringing through existing RCC poles, fixing in insulators, jumpers with polythene pipe, aluminium binding wire etc complete of different sizes all as directed. Note : Rates for new Aluminium cable terminal lugs are included in this rate.
5Supply and Fixing in repairs Galvanaised Iron cross arms channel, bracing, support, clamps,ISMB 200 X 100 x 6 mm,ISMB 150 x 100 x 6 mmetc fabricated structured steel, sections, including nuts, bolts, washers etc and cutting to required length beat to any shape drilling holes, fixed on poles or jointed by means of elect welding complete incl painting with 2 coats of aluminum paint over a coat of red oxide primer after preparation of surfaces incl taking down / dismantling the old items complete all as directed.
6Dismantling of existing old unserviceable earth wire and gradle guard of any size form the position, material and labour for providing new GI wire 4 mm dia (8 SWG) on poles to continuous earth wire and cradle guard etc, all as directed.
7Dismantling old unserviceable stay assy complete, material and labour for new stay assembly complete with 20 mm dia stay rod with accessories shown in electric plate No 01 inclstay clamp, (loop insulator, stay wire, excavation and concrete measured seperately)complete all as directed.
8Material and Labour in repairs for Galvanised Stay wire of size 7/4 mm incl dismantling old wire all as directed.
9Supply and Fixing in repairs for loop insulator Vitreous Porcelian white or brown of size 90 X 140 mm clearance hole 25.5 mm all as directed.
10Supply and Fixing in repairs of Plates (plain or chequered) channels,squarecutor notched (ordinary and counter sunk) forming holes, without any attachment cut to required shape and size for cable duct or any other description complete all as directed.
11Repairing/Servicing the Air break isolating switch HT 33 KV 200/400 Amps by replacingthe defective major spares including provn of minor bolts nuts etc all as specified. Note :- Major spare will be measured & paid seperately under relevant item of Sch"A" item No. 41
12Supply only 33 KV Airbreak switch spares all as directed.
13(a) Male contact/moving Contact Blade
14(b) Female contact/Fix Contact Jaw
15(c) Rotating contactor pipe 200A/400 A
16(d) MS jumper carrier
17(e) Back Connector plate
18Supply & Lay, testing and commissioning XLPE, cable, PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor33000 Volts grade (earthed), 3 core 185 sqmm laid in trenches / floor / duct / fixed on poles / through GI tubing including brass cable glands complete
19Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5 Mtr deep in hard/dense soil getting out and levelling of bottom surface to required level for laying of UG cable.
20Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5 Mtr deep in soft/disintegrated rock getting out and levelling of bottom surface to required levelfor laying of UG cable. .
21Excavation in trenches by cutting of road crossing / PCC hard standing, under boundary wallfor laying of pipe /cable including making good the existing surface with same finish to match the original finish complete all as specified and directed by Engr-in-charge.
22Returning filling in excavated earth work including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any strata
23Removing excavated soil to a distance n.exc 50m, depositing where directedat a level n.exc 1.5M above the starting point
24Supply and lay Double walled corrugated pipe (DWC) confirming to IS 14930 heavy duty 110/95 mm bore for cable protection as a guard pipe including required accessories etc. complete as specified and directed.
25Supply and Fixing intrench/on wall in repairs GItubing light grade for road crossing and cable protection ofsizes 100 mm dia as in repairs.
26Material and Labour for PVC insulated unarmoured heavy duty electric cable with copper conductor 1100 V grade with cross section area 4 Core 4 Sqmm all as direcetd.
27Material and Labour for PVC insulated armoured heavy duty electric cable with copper conductor 1100 V grade with cross section area 16 Core 2.5 Sqmm all as direcetd.
28Supply and Fixing in repairs drop out (DO) fuse unit expulsion type outdoor three pole 200 Amp suitable for HT 33 KV, comprising of insulators, steel base mounting frame, GI nut bolts etc with 30A, HT barrel type fuse complete
29Supply and Fixing in repairs incl testing, and commissioning of gang operated type air break switch horizontal/vertical type type mounting complete, double break and operation rod of suitable length 400 A capacity and suitable for 33 KV HT supply, complete all as specified and directed.
30Supply and Fixing in repairs lighting arrestor Zinc oxide gap less type, station class suitable for 33 KV/10 KA complete with all fittings all as specified and directed .
31Supply and Fixing in repairs single post insulator, 33 KV with mounting spindle etc all as specified and directed .
32Supply and Fixing in repairs Pininsulator, 33 KV with mounting spindle etc all as specified and directed .
33Supply and Fixing in repairs disc insulator, 33 KV with hardware fittings etc all as specified and directed .
34Material and Labour preparation of old painted external surfaces ofHT 2 pole structures consisting ofcross arms, GOD assy with pipe, DO fuse assy, clamps etc., of any descriptionand applying one coat of Aluminium paint by mannualy (Except PCC/RCC Pole) all as directed. Note for item No 1.33 to 1.35:- This rate inclusive of painting all minor items such as clamps, brackets, nuts, bolts and washers which is not particularly mentioned in the structures & Each job will be measured and paid.
35All as per item No 1.33 here in before but including Steel tubular pole or ISMB of size 150x100x6 mm 11 mtr long all as direcetd.
36All as per item No 1.33 here in before but for 4 pole structure all as directed.
37Material and Labour preparation of old painted surfaces ofHT 33/11 KV MRS at Hansa consisting ofSteel poles / ISMBs, cross arms, GOD pipe,clamps etc., having of any descriptionand applying one coat of Aluminium paint by mannualy (incl structure) all as directed. The approx particulars are as under :- (a) ISMB 200 X 100 x 6 mm 12 mtr height as pole - 18 Nos (b) ISMB 200 X 100 x 6 mm 2.5 to 3.5 mtr height as pole - 30 Nos (c) Angle Iron cross support 75 x 75 x 6 mm - 50 RM (d) MS Flat 50 x 4 mm - 24 Rm (e)C Channels of size 75 x 75x 6 mm - 110 RM (f) ISMB 150 x 100 x 6 mm as cross member - 284 RM Note :- (a) This rate inclusive of painting all minor items such as clamps, brackets, nuts, bolts and washers which is not particularly mentioned in this item. (b)This painting work will be carried out during Holidays only to avoid elect shut down.
38Material and Labour for servicing of 33 KV VCB at Hansa MRS, dismantling cleaninggreasing the complete VCB with attached relays bus bar etc insulation testing, setting the contact gap by measuring as required, reassembling the VCBand reinstalling back to its original positionchecking and repairsing the currentcircuit panel wiring , relay testing and provision of minor spares as required completeincluding operational testing and commissoning all as directed. Note : New major spare parts will be measured and paid under Sch A item No 33 (i) to (v)
39Material and Labour for replacement of the following for outdoor VCB 33 KV800 A 750 MVA fault level 36V-26/2000 make: Crompton Greaves/as approved by GE and all as directed including dismantling old unserviceable one.
40i)Closing coil30V DC
41ii)Tripping coil 30V DC
42iii)Anti pumping device 30V DC
43iv)33 KV porcelain bushing for VCB Top
44v) 33 KV porcelain bushing for VCBbottom
45vi)Connector strip 16 way
46vii)Earth Fault and over current relay of L & T Model No MC61A 24-110V
47viii)Digital type power factor indicator meter
48ix)Digital type Voltmeter / Ammeter 96 x 96 mm size
49Supply only rubber hand gloves of 33 KV grade ISI marked.
50Supply only fiber glass discharge rod in three sections and aluminium head with complete accessories suitable for 33 KV of 20 feet height.
51Supply and Fixing in repairs HT DO Fuse element for 33 KV system of 5 Amps.
52Supply and Fixing in repairs HT DO Fuse element for 33 KV system of 10 Amps.
53Supply and Fixing in repairs HT DO Fuse element for 33 KV system of 20 Amps.
54Supply and Fixing in repairs HT DO Fuse element for 33 KV system of 40 Amps.
55Supply and Fixing in repairs HT DO Fuse element for 33 KV system of 50 Amps.
56Supply and Fixing in repairs HT DO Fuse element for 33 KV system of 60 Amps.
57Supply and Fixing in repairs sealed maintenance free battery 2 Volts 100 Amps for UPS supply incl necessary connections complete all as directed.
58Material and Labour for taking out the MS duct cover from the cable duct chamber disconnecting the haphazardly laid serviceable HT UG cable of 3 core of 95 to 185 Sq mm from VCB/Any description taking out from cable trenches / ducts and straighten and laying in proper layers incl provn of new identification tags for each cables and connecting back to its original position incl cleaning the cable ducts all as directed.
59Supply and Fixing in repairs for Breather unit with superior quality blue colour silica jel,to maintain the exact value ofgrade for transformer of capacity 33/11 KV type 2 MVA Transformer, including taking down unserviceable complete all as specified.
60Supply and Fixing in repairs HV insulator withstuds nut & washers suitable for 33 / 11 KV,HV side of transformer 2 MVA
61Supply and Fixing in repairs LV insulator withstuds nut & washers suitable for 33/11 KV LV side of transformer of Capacity 2 MVA
62Material and Labour for Earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to copper strip size 20 x 3 mm thickby mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earthing strip shall be provided with GI pipe light grade 32 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamberin cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and as directed.
63Material and Labour for painting of HT panel of any description with one coat of synthetic enamel paint of standard colour code over the existing painted surfaces after preparing the old painted surfaces by using spray gun all as directed.
64Material and Labour for removing vegitation, grass, scrubs and bushes growing in Sub station yard along with fancing by mannually / mechanically and keep the sub station yard neat and clean complete all as specified and as directed. Note :- Unit rate quoted deemed to include to keep the installation neat and clean through out the period of contract and each cleaning will be measured and paid separately. cutting of grass is month wise measured and paid separeatly.
65Material and Labour for Cutting and trimming of tree branches 3 mtr all around of any size which is obstructing illumination of street light and touching LT / HT Over head line by using required tools and plants incl removing trimmed tree branches. (Note : Each cleaning will be measured and paid separetely)
66Supply and Fixing in repairscable jointing kit for 33KV grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 185 sqmm.
67Supply and Fixing in repairs cable jointing kit for 33KV grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 185 sqmm.
68Supply and Fixing in repairs cable jointing kit for 33KV grade cable for Straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 185 sqmm.
69Carry out Material/machineries labour for foult finding of 33 KV or 11 KV HT under ground cable of length up to 1.5 KM in case of cable foult such as short circuit/burn out/earth foult etc including carryout necessary hypot test by injection high voltage up to 50 KV complete all as specified and as directed.
70Supply and Fixing in repairsincl testing, and commissioning lightning arrester(LA) for 33KV HT grade with nuts, bolts, washers, clams and all acesaries as per sample including taking down unserviceable complete all as specified by engr- in- charge. Note :- Any item not included in CA and required for successful operation of the panel will be provided by the contractor & same shall deemed to be included rate quoted.
71Supply and Fixing in repairsincl testing, and commissioning Aluminium bus bar of 32 MM dia for 33KV HT grade with nuts,bolts, washers , clams and all acesaries as per sample including taking down unserviceable complete all as specified by engr- in- charge Note :- Any item not included in CA and required for successful operation of the panel will be provided by the contractor & same shall deemed to be included rate quoted.
72Supply and Fixing in repairsincl testing, and commissioning Aluminium bus bar of 25 MM dia for 33KV HT grade with nuts,bolts, washers , clams and all acesaries as per sample including taking down unserviceable complete all as specified by engr- in- charge Note :- Any item not included in CA and required for successful operation of the panel will be provided by the contractor & same shall deemed to be included rate quoted.
73Disconnecting, opening of VCBof any description and any make of rating 11 KV 400/800 Amps capacity for servicing / overhauling, taking out and removing unserviceable / defective parts including cleaning & servicing, greasing, oiling of the parts etcand replacement of unserviceable parts with new one, reassembling the VCB after overhauling/ servicing and its testing complete all a specified and directed. Note: (i) Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch "A" as supply only but fixing charges of the parts replaced /repaired is deemed to be included in these item. (ii) Servicing shall be got carried out by the authorised rep of the VCB manufacturer and the service engineer will submit a service report for each VCB. (iii) Any item not included in CA and required for successful operation of the panel will be provided by the contractor & same shall deemed to be included rate quoted.
74Supply only following items/spare parts suitable for 11KV VCB, 400/800 Amps capacityof any makedismantled / fixed under Sch "A" item No: 04here-in-before complete all as specified and directed.
75(i) vacuum circuit breaker main mechanism assembly complete with all accessories all as specified and directed by Engr-in-Charge
76(ii) Vacuum Interrupter type WL-33379 suitable for 11 KV VCB Panelcomplete all as specefied and directed.
77(iii) Isolating contact assembly 400/800 Amps suitable for 11 KV VCB Panelcomplete all as specefied and directed.
78(iv) Tripping Coil assembly 30 Volts DC suitable for 11 KV VCB Panelcomplete all as specefied and directed.
79(v) Close Coil assembly 30 Volts DC suitable for 11 KV VCB Panelcomplete all as specefied and directed.
80(vi) Motor & Gear assembly 110V AC and 220 ACfor 11 KV VCB Panelcomplete all as specefied and directed.
81(vii) TNCswitch for 11 KV VCB Panelcomplete all as specefied and directed.
82(viii) Indication lamp LED type suitable for 230 Volts AC 50Hz and 110/30 Volts DC supply.
83Disconnecting and taking down unserviceable current transformer of any description and in any position and supply, installation, commisioning and testing of cast resin type 11KV current transformer having ratio 100+50/5+5Aas per IS: 2705 having protection core class 5P10, burden of 15VA and metering core class CL1.0 and burden of 15VA, breaking capacity of 13.1 KV for 1.0 second all as specified and directed.
84Disconnecting and taking down unserviceable voltage transformer of any description and in any position and supply, installation, commisioning and testing for 11KV single phase indoor oil cooled PT of ratio 11KV/RT 3/10V/RT 3/110/RT 3 class 0.5-3, burden 100VA, insulation level 35/75 KV, voltage factor 1.2 cont and 1.9 for 30 sec, conforming to IS-3156 complete all as specified and directed.
85Taking out old but serviceableACB of capacity 400 to 1200 amps 415 volts AC 50 HZ at various sub station and carry out necessary servicing, gresing to fixed and movable part, cleaning complete internally and testing after reinstallation. (Any demage occures during servicing will be borne by the contractor).
86Supply and fix charging motor 110V AC/DC, 220V AC/DC of suitable sizefor ACB of capacity 400 to 1200 Amps complete all as specified and directed by Engr-in-charge
87Supply and fix control relay for charging motor 110V AC/DC, 220V AC/DC of suitable sizefor ACB of capacity 400 to 1200 Amps complete all as specified and directed by Engr-in-charge
88REPAIR / MAINTENANCES OF EXTERNAL ELECT INCLUDING LT OHT LINES, UG CABLES, LT POLES STREET / SECURITY / PERIMETER / HIGH MAST LIGHTS, LT PANELS INCLUDING APFC PANELS, EARTHING AND CONNECTED WORKS AT NORTH SIDE RUNWAY UNDER AGE E/M - I
89Supply and Fixing in repairs integral LED aviation light comprising of aluminium housing with polycarbonate enclosure with necessary fixing arrangement such as GI pipe, fixing clamp, brackets, etc., complete all as specified and directed by Engr-in-charge.
90Supply and Fixing in repairs 1x60 watts LED building security light made up of pressure die cast housing with toughned glass and individual LEDs with secondary optics and IP66 protection for building security lights all as specified and directed by Engr-in-charge.
91Material and Labour for in repairs Street light bracket made out of GI tubing 32/40 mm dia, light grade bend to shape suitable for below mentioned security light fitting with necessary MS clamps with one coat of red oxide and two coats of aluminium paint including nut, bolt, washers etc all as specified and directed by Engr-in-charge.
92Supply and fixin repairs LED flood light fitting 200 watts made in pressure die cast aluminium housing and reflector and enclosed with toughened glass with IP66 protection complete with all accessories such as LED"s and electronic driver, internally prewiredincluding necessary fixing arrangement on PCC pole/high mast pole/wall by providingMS angle iron bracket 50x50x6mm of adequate length as per site requirement with MS flat iron clamp 32x6 mm with necessary nuts, bolts and washers etc and making cable connection all as specified and directed.
93Supply and fixin repairs LED flood light fitting 240 watts made in pressure die cast aluminium housing and reflector and enclosed with toughened glass with IP66 protection complete with all accessories such as LED"s and electronic driver, internally prewiredincluding necessary fixing arrangement on PCC pole/high mast pole/wall by providingMS angle iron bracket 50x50x6mm of adequate length as per site requirement with MS flat iron clamp 32x6 mm with necessary nuts, bolts and washers etc and making cable connection all as specified and directed by Engr-in-charge.
94Supply and Fixing in repairs wind LED wellglass luminaires 1x30 watts Energy saving, environment friendly & robust open type verticalLED luminaire with high power LED as light source all as specified and as directed.
95Supply and Fixing in repairs LED High bay luminaires 1x195 watts Energy saving, environment friendly & robust open type vertical Highbay LED luminaire with high power COB LED as light source all as specified and directed by Engr-in-charge.
96Supply and Fixing in repairs LED High bay luminaires 1x200 watts Energy saving, environment friendly & robust open type vertical Highbay LED luminaire with high power COB LED as light source all as specified and directed by Engr-in-charge.
97Taking down unserviceable any type of copper/aluminium sub main wiring of any type/size/core type complete including conduits/casing caping etc, removing the materials/ debris and making good the disturbed surfaces of walls, floors and ceilings etc to match with the original existing finish all as specified and directed by Engr-in-charge.
98Material and Labour for sub main wiring with two runs of single core 2.5 Sqm, FRLSCopper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non- metallic rigidPVC casing caping (double interlock type) of suitable width medium dutywith all accessories such as Tees, elbows,junction boxes etc, as required fixed on wall along with one run of 2.5 Sqmm single core PVC FRLSinsulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc all as specified and directed by Engr-in-charge. (Note :- Two runs of cable, one run of earth continuity conductor and one run of PVC casing caping/conduit shall be measred as one unit)
99All as per item No 75 here in before, but two run of single core 4 sqmm and one run of 4 sqmm cables as earth continuity conductor.
100All as per item No 75 here in before, but two run of single core 6 sqmm and one run of 4 sqmm cables as earth continuity conductor.
101All as per item No 75 here in before, but four run of single core 6 sqmm and two run of 4 sqmm cables as earth continuity conductor.
102All as per item No 75 here in before, but four run of single core 10 sqmm and two runs of 6 sqmm cables as earth continuity conductor.
103Supply and Fixing in repairs Switch Flameproof WP Rotary type with termination box in LM6,15A single pole 250V all as specified and directed by Engr-in-charge.
104Supply and Fixing in repairs Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth all as specified and directed by Engr-in-charge.
105Supply and fixing LED light fitting 30 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protectio with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size all as specified and directed by Engr-in-charge.
106Supply and fixing in repairs flame proof exhuet fan motor with body of size 300 mmsweep complete all as specified and directed by Engr-in-charge.
107Supply and fixing in repairs flame proof exhaust fan sweep of size 300 mm sweep complete all as specified and directed by Engr-in-charge. Note:- Fan Blade make and size should be supply with the mach of under relivent item of Sch Aserial No 83 as above.
108Taking down unserviceable any type of Main Switch, DB"s including MCBs incl wooden/GI/MS sheet board etc and removing from site and making good the disturbed surface of wall etccomplete all as specified and directed by Engr-in-charge.
109Supply and Fixing in repairs sheet metal enclosure SPN with a two pin and earth plug and socket complete with one SP MCB 20 Amps complete all as specified.
110All as per item No 86 here in before but MCB DB TPN 4 way DB 415 V with 200 A rated busbar triple pole.
111Supply and Fixing in repairs MCB DB SPN 8 way DB 230 V with 200 A rated bus bar double door typecomplete all as specified and directed by Engr-in-charge.
112All as per item No 88 here in before but MCB DB SPN 4 way DB 230 V with 200 A rated busbar.
113All as per item No 88 here in before but MCB DB SPN 12 way DB 230 V with 200 A rated busbar.
114Supply and Fixing in repairs MCCB DB TPN, 8 way, (MCCB + 24 way O/G) double door, vertical type provision one MCCB of 100 amps breaking capacity 18 KA, 4 pole without MCBcomplete all as specified and directed by Engr-in-charge.
115Supply and Fixing in repairs vertical type MCCB DB TPN 4 way, 415 volts, double door, factory made sheet metal enclosure with 200 amps rated copper bus bar, neutral bar, earth bar painted with epoxy based powder coated suitable for mounting MCCB FP 63 amps as incomer and MCB TP/SP as outgoings complete with IP-43 protection and concealed in wall including making incoming and outgoing cable/wire connectionscomplete all as specified and directed by Engr-in-charge.
116Supply and Fixing in repairs MCB TPN32 amps 415 volts C curve, 50 HZ AC 10 KAcomplete all as specified and directed by Engr-in-charge.
117Supply and Fixing in repairs MCB TPN40 to 63 amps 415 volts C curve, 50 HZ AC 10 KAcomplete all as specified and directed by Engr-in-charge.
118Supply and Fixing in repairs MCB TP 32 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified and directed by Engr-in-charge.
119Supply and Fixing in repairs MCB TP 40-63 amps 415 volts C curve, 50 HZ AC 10 KAcomplete all as specified and directed by Engr-in-charge.
120Supply and Fixing in repairsMCB SPN06 -32 amps 230 volts C curve, 50 HZ AC 10 KAcomplete all as specified and directed by Engr-in-charge.
121Supply and Fixing in repairsMCB SP 06 to 32 amps 230 volts C curve, 50 HZ AC 10 KAcomplete all as specified and directed by Engr-in-charge.
122Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjutable type 125 to160 Amps with breaking capacity 25 KA complete including necessary connection with suitable size aluminum/copper cable lugs complete all as specified and directed by Engr-in-charge.
123Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjutable type 200 Amps with breaking capacity 25 KA complete including necessary connection with suitable size aluminum/copper cable lugs complete all as specified and directed by Engr-in-charge.
124Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjutable type 250 Amps with breaking capacity 25 KA complete including necessary connection with suitable size aluminum/copper cable lugs complete all as specified and directed by Engr-in-charge.
125Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjutable type 400 Amps with breaking capacity 50 KA complete including necessary connection with suitable size aluminum/copper cable lugs complete all as specified and directed by Engr-in-charge.
126Supply and fix in repairs MCCB of 100 to 125 A breaking capacity 18 KA , 4 pole thermal megnetic release, compact type suitable for MCCB DB Vertical type as incoming in the existing DB"s c complete all as specified and directed by Engr-in-charge.
127Supply and fix in repairs MCCB of 63 A breaking capacity 18 KA, 4 pole thermal megnetic release, compact type suitable for MCCB DB Vertical type as incoming in the existing DB"s c complete all as specified and directed by Engr-in-charge.
128Supply and Fixing Energy efficient surface Mounted LED Luminire 18/20 watts 4" long, with acrylic cover complete with all accessories incl necessary two core copper wire for connection from ceiling rose to connector of approx length 0.75 mtr and removal of old unserviceable lightscomlete all as specified and directed by Engr-in-Charge.
129Supply and fixing LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete and necessaryfixing arrangementat any height and removing old unserviceablecomlete all as specified and directed by Engr-in-Charge.
130Supply & fix recess mounting high lumenLED flat panel 1"X1" 18 Watt, white powder coated CRCA housing with highpower LED, aluminium front frame with flat white high transmission acrylic cover, internally prewired, 230V, complete with all accessories such as electronic driver, LED strip,connector block etc.and necessaryfixing arrangementat any height and removing old unserviceable itemcomplete all as specified and directed by Engr-in-charge.
131Supply & fix in repairs recess mounting high lumen LED flat panel4" x 1" 36 Watt, white powder coated CRCA housing with highpower LED, aluminium front frame with flat white high transmission acrylic cover, internally prewired, 230V,complete with all accessories such as electronic driver,LED strip,connector block etc.and necessaryfixing arrangementat any height and removing old unserviceable itemcomplete all as specified and directed by Engr-in-charge.
132Supply and Fixing in repairs LED light fitting 1x18 watts Surface mounted LED downlighter in powder coated white finish with integrated electronic drivercomplete all as specified and directed by Engr-in-charge.
133Supply and Fixing in repairs Fluorescent tube light fitting. 1x36W flameproof type FLP-WP made of aluminium alloy LM6, with electronic ballast, bipin holders, connector block, etc. complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engr-in-charge.
134Supply and Fixing in repairs PVC Casing & Caping double lock type of as required width (not less than 20/25 mm in width) ISI marked medium grade white colour with all accessories of same grade fixed on wall/ceiling etc. complete all as specified and as directed.
135Material and Labour for Earthing complete with GI earth plate, electrode,600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) filled with common salt and charcoal and connected to GI earth strip 32x 6 mm thick dia by means of GI nuts, bolts, & washers as shown in electrical plate No. 5 of SSR Part-I and Connected to earthing test point all as specified and including necessary PCC earth pit chamber of 1:3:6 and chamber cover of 50mm thick PCC 1:2:4 with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover, watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 40 mm dia unto 7.5 from the earth plate electrode & refilling of soil etc including necessary excavation & earth work in any strata and PCC chamber all as specified and directed by Engr-in-Charge including demolish existing earth pit taking out old materials complete all as specified and directed by Engr-in-charge. .
136Material and Labour for Earthing complete with Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earth lead shall be provided with GI pipe light grade 20 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamberin cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and directed by Engr-in-charge.
137Supply and Fixing copper strip 20x3 mm Earth continuity conductor fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified and directed by Engr-in-charge.
138Supply and wrapping of LT insulation tape 12 mm width in 5 mtr roll complete all as specified and directed by Engr-in-charge.
139Supply and Fixing in repair Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed by Engr-in-charge.
140Supply and Fixing Perforatted cable Tray made out of GI Sheet of 14 SWG thickness and 40 to 50 mm depth hot dipped in various width sizes including accessories like couplar plate, nut bolts, washers clamps, wall bracket up/down elbows, bends tees equal distances on wall/floor/through wall crossing and making good the surface, complete all as specified.
141Supply and Fixing in repair informatory sign boards/display chart with single side writing over foam sheet of 4 mm thick (maximum size 2 mtr x 1 mtr) fixed on wall with screw. nuts and bolts etc. complete all as specified and directed by Engr-in-charge. Note :- wright matters will be provided by departmaint as per requirment.
142Material and Labour for painting of LT panel of any description with one coat of synthetic enamel paint of standard colour code over the existing painted surfaces after preparing the old painted surfaces by using spray gun and marking of all incoming and out goining MCB/MCCBS complete all as specified and directed by Engr-in-charge.
143Supply and Fixing in repairs capacitor of 2.5/3.15 mfd capacity for ceiling fan of any sweepcomplete all as specified and directed by Engr-in-charge.
144Supply and Fixing in repair Analog time switch fixed in timer panal including connectionwith screw. nuts and bolts etc. complete all as specified and directed by Engr-in-charge.
145Taking down Aluminum strip of size 25x3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground and refixing in the same location with new nuts and bolts, screwsof suitable size and length and connected to air termination rod on op of the hangarcomplete all as specified and directed by Engr-in-charge.