Tender For Construction Of Farmers Hostels At Regional Research Station, Chansoli (Ambala)
Tender Overview
Project Description
Construction Of Farmers Hostels At Regional Research Station, Chansoli (Ambala)
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 01-Dec-2022 | date extended | Date | 07-Dec-2022 |
BOQ
| Sl. No. | Item Description |
| 1 | Description and details |
| 2 | HSR ITEM NO. 4.14 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 4.14.1 All kinds of soil |
| 3 | HSR ITEM NO. 4.32 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 4 | HSR ITEM NO. 4.39 Providing and injecting chemical emulsion for PRE-CONSTRUCTIONAL anti termite treatment and creating achemical barrier under and around the column pits, walltrenches, basement excavation, top surface of plinth filing junction of wall and floor, along with the external perimetre of building, expansion joints surrounding of pipes and conduit etc, complete (plinth area of the building at ground floor only shall be measured) using Chlorpyriphos/ Lindane emulsifiableconcentrate of 20% |
| 5 | HSR ITEM NO. 6.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level. 6.1.61 :4: 8 ( 1 Cement : 4 coarse sand (zone-Ill) : 8 graded cum stone aggregate 40 mm nominal size) |
| 6 | HSR ITEM NO. 6.8Providing and laying damp-proof course with cement concrete 1 :2:4 (1 cement : 2 coarse sand (zone-Ill): 4 graded stone aggregate 12.5mm nominal size)6.8.2 40mm |
| 7 | HSR ITEM NO. 6.10 Providing & applying a coat of residual petroleum bitumen of sqm grade of VG-1 O of approved quality using 1. 7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. |
| 8 | HSR ITEM NO. 6.13 Making plinth protection 50mm thick of cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth |
| 9 | HSR ITEM NO. 6.14 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement-All work up to plinth level:6.14.1 1:1.5:3 ( 1 cement : 1. 5 coarse sand (zone-Ill): graded stone aggregate 20 mm nominal size) |
| 10 | HSR ITEM NO. 6.14.2 1 :2:4 (1 cement : 2 coarse sand (zone-Ill) : 4 graded cum stone aggregate 20 mm nominal size) |
| 11 | HSR ITEM NO. 6.15 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor four level, excluding cost of centering, shuttering, finishing and reinforcement :6.15.1 1:1.5:3 (1 cement : 1.5 coarse sand(zone-111) : 3 cum graded stone aggregate 20 mm nominal size) |
| 12 | HSR ITEM NO. 6.16 Reinforced cement concrete work in beams, suspended floors, cum roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1: 1.5:3 (1 cement : 1.5 coarse sand(zone-111) : 3 graded stone aggregate 20 mm nominal size). |
| 13 | HSR ITEM NO. 6.30 Centering and shuttering including strutting, propping etc. and removal of form for 6.30.1Foundations, footings, bases of columns, etc. for mass concrete |
| 14 | HSR ITEM NO. 6.30.3 Suspended floors, roofs, landings, balconies and |
| 15 | HSR ITEM NO. 6.30.5Lintels, beams, plinth beams, girders, bressumers and cantilever |
| 16 | HSR ITEM NO. 6.30.6 Columns, Pillars, Piers, Abutments, Posts and Struts |
| 17 | HSR ITEM NO. 6.30.7 Stairs, (excluding landings) except spiral-staircases |
| 18 | HSR ITEM NO. 6.30.15 Small lintels not exceeding 1.5 m clear span,moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like |
| 19 | HSR ITEM NO. 6.30.16.1Edges of slabs and breaks in floors and walls |
| 20 | HSR ITEM NO. 6.30.19 Weather shade, Chajja, corbels etc., including sqm edges |
| 21 | HSR ITEM NO. 6.34 Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth levelNote:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement.6.34.6 Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 22 | HSR ITEM NO. 6.39 Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1 :3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete.6.39.1 1:1½ :3 (1 Cement: 1½ coarse sand (zone-111) : 3 cum graded stone aggregate 20 mm nominal size). |
| 23 | HSR ITEM NO. 7.21 Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in:7.21.2 Cement mortar 1:6 (1 cement: 6 coarse sand) |
| 24 | HSR ITEM NO. 7.22 Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 7.22.2 Cement mortar 1:6 (1 cement: 6 coarse sand) |
| 25 | HSR ITEM NO. 7.28 Half brick masonry with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level.7 .28.2 Cement mortar 1 :4 ( 1 cement :4 coarse sand) |
| 26 | HSR ITEM NO.8.17 Providing & fixing factory manufactured jali of reinforced cement concrete consisting of cement , coarse sand and 10mm & down gauge bajri in ratio of 1: 1 :2 with Bmm dia tor steel. Outer frame of the jail will be 50mm wide & 25mm thick & inner frame of jali will be 25mm wide and 25mm thick with smooth finish as per design approved by the Engineer-in-Charge including fixing in position up to any height with cement sand mortar 1 :4 complete in all respect |
| 27 | HSR ITEM NO.8.26 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1 :4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 8.26.2.2 Area of slab over 0.50 sqm |
| 28 | HSR ITEM NO.8.27 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 8.27.2 Granite work |
| 29 | HSR ITEM NO.8.28 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platfonn, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 30 | HSR ITEM NO.9.10 Painting top of roofs with bitumen of approved quality @ 17kg per 10 sqm impregnated with a coat of coarse sand at 60 cudm per 10 sqm, including cleaning the slab surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil complete9.10.1 With residual type petroleum bitumen of grade VG -10 |
| 31 | HSR ITEM NO.9.11 10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1: 1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1 :3 (1 cement: 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat:9.11.1 With common burnt clay non-modular brick tile of class sqm designation 10 |
| 32 | HSR ITEM NO.9.17 Providing gola 75x75 mm in cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1 :3 (1 cement : 3 fine sand) as per standard design :9.17.1 In 75x75 mm deep chase |
| 33 | HSR ITEM NO.9.18 Making khurras 45x45 cm with average minimum thickness of 5 cm cementconcrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1 :3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 34 | HSR ITEM NO. 9.47.2 GI Metal Ceiling Lay in perforated Tegular edge global white colour tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fibre acoustical fleece |
| 35 | HSR ITEM NO. 10.1 Providing and laying of base course of floors consisting of 100 mm thick cement 1 :8: 16 and 100 mm sand or stone filling. |
| 36 | HSR ITEM NO. 10.2 Supplying and filling in plinth with sand (conforming to zone-IV, IS 1542) under floors, including watering, ramming, consolidating and dressing complete.. |
| 37 | HSR ITEM NO. 10.4 Providing and laying of screed of 50 mm thick cement concrete 1:8:16 to be laid below the topping |
| 38 | HSR ITEM NO. 10.4 Providing and laying of conglomerate floor 40mm thick cement concrete topping 1 :2:4 |
| 39 | HSR ITEM NO.10.10 Providing and laying Cement concrete flooring 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 10.10.1 40 mm thick with 20 mm nominal size stone aggregate |
| 40 | HSR ITEM NO. 10.14 Providing a floating coat of 1.50 mm thick neat cement laid in one operation to the topping |
| 41 | HSR ITEM NO.10.22 Providing and fixing glass strips in joints of terrazzo/ cement concrete floors. 10.22.1 40 mm wide and 4 mm thick |
| 42 | HSR ITEM NO.10.30.4 Providing and laying of chequered precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1 :4 (1 cement: 4 coarse sand).Ordinary cement without any pigment |
| 43 | HSR ITEM NO.10.37 Providing and fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 ( 1 cement : 4 coarse sand) : 10.37.1 25 mm thick |
| 44 | HSR ITEM NO.10.38 Providing and fixing of Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 45 | HSR ITEM NO.10.42 Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. |
| 46 | HSR ITEM NO.10.43 Extra for Kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre. |
| 47 | HSR ITEM NO.10.57 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1 :4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 48 | HSR ITEM NO.10.58 Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1 :3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 49 | HSR ITEM NO.10.63Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1 :4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 10.63.2 Size of Tile 600x600 mm |
| 50 | HSR ITEM NO.10.67 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1 :3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete.10.67.2 Size of Tile 600x600 mm |
| 51 | HSR ITEM NO.10.70 Extra for grouting the joints of floor tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. 10.70.2 Size of Tile 600x600 mm |
| 52 | HSR ITEM NO.11.4 10 mm thick cement plaster11.4.21 :3 (1 cement: 3 fine sand) |
| 53 | HSR ITEM NO. 11.8 12 mm cement plaster of mix :11.8.2 1 :6 (1 cement: 6 coarse sand) |
| 54 | HSR ITEM NO.11.9.1 15 mm cement plaster on rough side of single or half brick wall of mix:11.9.2 1 :6 (1 cement: 6 coarse sand) |
| 55 | HSR ITEM NO.11.17 Providing and fixing of chicken wire mesh for avoiding cracks in plaster withnecessary nail/screws etc. complete in all respect to the entire satisfaction of engineer-in-charge |
| 56 | HSR ITEM NO.11.54 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C.Projection. |
| 57 | HSR ITEM NO.11.59Providing and applying plaster of paris putty of 2 mm thickness over plasteredsurface to prepare the surface even and smooth complete. |
| 58 | HSR ITEM NO.11.58 Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete |
| 59 | HSR ITEM NO.11.77 Applying pink primer or aluminium priming coat on wood work includingpreparation of surface, Knotting and stopping etc. |
| 60 | HSR ITEM NO.11.78 Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. |
| 61 | HSR ITEM NO.11.64 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade:11.64.1 New work (two or more coats) over and including water thinnable priming coat with cement primerew work |
| 62 | HSR ITEM NO.11.82Painting the wooden/metal surface with synthetic enamel paint of approved brand and manufacture to give an even shade. 11.82.1 Two or more coats on new work |
| 63 | HSR ITEM NO.11.94.1 Finishing walls with textured exterior paint of required shadeNew work (Two or more coats applied @ 3.28 litre/10 sqm) |
| 64 | HSR ITEM NO.11.98 Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gmnitre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives.11.98.1 New work (Two or more coats applied @ 1.43 litre/ 10 sqm Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm |
| 65 | HSR ITEM NO.11.107 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work.11.107.1 15 mm dia nominal bore |
| 66 | 11.107.2 20 mm dia nominal bore |
| 67 | 11.107.3 25 mm dia nominal bore |
| 68 | HSR ITEM NO.11.108 Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality.11.108.4 32 mm diameter pipe |
| 69 | 11.108.5 40 mm diameter pip |
| 70 | 11.108.6 50 mm diameter pipe |
| 71 | HSR ITEM NO. 12.32 Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws.with ISi marked M.S. pressed butt hinges bright finished of required size. 12.32.1 35 mm thick shutters12.32.1.1.2 Kiln seasoned and chemically treated sqm Hollockwood |
| 72 | HSR ITEM NO.12.33 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complet.12.33.2 With 12 mm mild steel U beading |
| 73 | HSR ITEM NO. 12.37 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 12.37.1 35 mm thick including ISi marked Stainless Steel butt hinges withnecessary screw |
| 74 | HSR ITEM NO.12.37.3 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screw |
| 75 | HSR ITEM NO.12.49 Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets: 12.49.2 25 mm dia (heavy type) |
| 76 | HSR ITEM NO.12.50 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. HSR ITEM NO.12.50.2 Fixed to openings /Wooden frames with rawl plugs screws etc. |
| 77 | HSR ITEM NO.12.87 Providing and fixing magnetic catcher of approved quality in cupboard/ ward robe shutters, including fixing with necessary screws etc. complete.12.87.2) Double strip (horizontal type) |
| 78 | HSR ITEM NO. 12.88 Providing and fixing aluminium die cast body tubular type universal hydraulicdoor closer (having brand logo with ISi, IS : 356 4, embossed on the body, door weight up to 35 kg and door width up to 7 00 mm), with necessary accessories and screws etc. complete. |
| 79 | HSR ITEM NO. 12.98 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :12.98.1300x16 mm |
| 80 | HSR ITEM NO. 12.99 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete. 12.99.2 250x10 mm |
| 81 | 12.99.3 200x10 mm |
| 82 | 12.99.4 150x 10 mm |
| 83 | HSR ITEM NO. 12.102 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 1 O as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete.12.102.1 125 mm |
| 84 | HSR ITEM NO. 12.102 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 1 O as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete. 12.102.2 100 mm |
| 85 | HSR ITEM NO. 12.103 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. 12.103.2 Twin rubber stopper |
| 86 | HSR ITEM NO. 12.118.2 30 mm thick factory made Polyvinyl Chloride (PVC) door shutter sqm made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (:t 0.2 mm), with inbuilt decorative moulding edging on one side. The styles and rails mitred and joint at the comers by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm (:t 0.1 mm) wall thickness. The lock rail made up of \"H\" section, a uPVC hollow section of size 100x30 mm and 2 mm (:t 0.2 mm) wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. \"U\" cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (:t 0.1 mm) wall thickness . The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer\"s specification and direction of Engineer-in-charge. |
| 87 | HSR ITEM NO. 12.119 Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a metre wall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at comers and joined with 2 Nos. of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer\"s specification and direction of Engineer- in-Charge |
| 88 | HSR ITEM NO. 12.157 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : 12.157.1 For fixed portion12.157.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 89 | HSR ITEM NO. 12.157.2 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)12.157.2.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 90 | HSR ITEM NO.12.159 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):12.159.1 With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 91 | HSR ITEM NO.13.4.1 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cementconcrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) |
| 92 | HSR ITEM NO.13.29.2 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 93 | HSR ITEM NO.13.41 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 94 | HSR ITEM NO.17.5.3 Compaction of & preparation of sub grade including loosening, levelling of earth 225 mm thick top layer, rough dressing of soil, final dressing of earth to give level, camber, watering, rolling with road roller, compacting the bed to achieve minimum dry density as given in the Table 3000-2 as per technical clause 305 of MORT&H specifications (in case of link roads earthwork to be done by villagers) |
| 95 | HSR ITEM NO. 17.22.1 Water Bound Macadam Grading I (without screenings for low volume roads(undesignated)Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications |
| 96 | HSR ITEM NO. 17.23.2 Water Bound Macadam - II with Screening Type \"A\"/Type B Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory roller 8-1 0 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density complete as per technical clause 404 of MORT&H specifications |
| 97 | HSR ITEM NO. 17.69.2 Providing and Laying 80 mm thick ISi marked lntertocking Paver Blocks conforming to IS 15658:2006/IRC SP 63: 2004 of all shapes and colours in design mix cement M 40 over the bed of 30 mm thick fine sand complete in all respect. |
| 98 | HSR ITEM NO.30.82 Making holes by cutting cores of appropriate dia in RCC floors and roofs of thickness up to 6\" (six inches) for passing drain pipe and repairing the hole after insertion of drain pipe etc. includingfinishing-complete so as to make it leak proof. 30.82.1 Drain pipe of 150mm internal dia |
| 99 | HSR ITEM NO.30.82.2 Drain pipe of 100mm internal dia |
| 100 | (NS) Supplying and filling of local earth at site brought from outside the campus with irrespective of lead, including loading & unloading, carriage,royalty/compensation etc. The earth will be laid in 25 cm layers & will be compacted with 8-10 Ton Road Rollar I/c ramming ,watering and consolidation complete in all respects tothe entire satisfaction of the Engineer-in-charge. |
| 101 | NS Providing and fixing 25 mm thick finished red sand stone both side slightly rounded for partition and shelves in Cupboard |
| 102 | NS Providing & Fixing aluminium fittings for door and windows shutters with stainless steel or C.P brass screws of required size complete.Folding Handle 100mm |
| 103 | NS Extra for Granite polish on Kota stone flooring |
| 104 | PH WORKHSR ITEM NO. 4.16 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:4.16.2 Pipes, cables etc. exceeding 80 mm metre dia. but not exceeding 300 mm dia. |
| 105 | HSR ITEM NO. 9.57 Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 9.57.2 110 mm diameter |
| 106 | HSR ITEM NO. 9.58 Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 1 O mm gap for thermal expansion.9.58.2 Single push fit Coupler9.58.2.2 110 mm |
| 107 | HSR ITEM NO. 9.58.5 Bend 87.5° 9.58.5.2 110 mm bend |
| 108 | HSR ITEM NO. 9.59 Providing and fixing Unplasticised -PVC pipe clips of approved design to Unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1 :4 (1 cement : 4 coarse sand) and making good the wall etc. complete.9.59.1 75 mm |
| 109 | HSR ITEM NO. 9.59 Providing and fixing Unplasticised -PVC pipe clips of approved design to Unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1 :4 (1 cement : 4 coarse sand) and making good the wall etc. complete.9.59.2 110 mm dia |
| 110 | HSR ITEM NO. 22.4 Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White vitreous chinaware Flat back wash basin size 550x400 mm with single 15 mm PTMT pillar cock. |
| 111 | HSR ITEM NO. 22.10 Providing and fixing Stainless Steel A ISi 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required. HSR ITEM NO. 22.10.1 Kitchen sink with drain board 22.10.1.1 510x1040 mm bowl depth 250 mm |
| 112 | HSR ITEM NO. 22.14 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 22.14.2.1 32 mm dia |
| 113 | 22.14.2.2 40 mm dia |
| 114 | HSR ITEM NO.22.25 Providing and fixing white vitreous chinaware flat back or wall comer type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: 22.25.2 One urinal basin with manually operated 5 litres PVC cistern and each 1307 1879 3186 manually operated stop cock/ angle valve |
| 115 | HSR ITEM NO. 22.38 Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. |
| 116 | HSR ITEM NO. 22.86 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 22.86.2 20 mm nominal outer dia Pipes |
| 117 | HSR ITEM NO.22.88 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal Work- Exposed on wall22.88.1 15 mm dia nominal bore |
| 118 | 22.88.2 20 mm dia nominal bore |
| 119 | 22.88.3 25 mm dia nominal bore |
| 120 | HSR ITEM NO.22.91 Providing and fixing G.I. pipes complete with G.I. fittings including trenching up to 0.30m to 1.00m depth and refilling etc. 22.91.4 32 mm dia nominal bore |
| 121 | 22.91.5 40 mm dia nominal bore |
| 122 | 22.91.6 50 mm dia nominal bore |
| 123 | HSR ITEM NO.22.92 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete: 22.92.1 25 to 40 mm nominal bore |
| 124 | HSR ITEM NO.22.93 Providing and filling sand envelope of grading zone grade, 100mm all-round the G.I. pipes in external work: 22.93.4 32 mm diameter pipe |
| 125 | HSR ITEM NO. 22.93.540 mm diameter pipe |
| 126 | HSR ITEM NO. 22.93.650 mm diameter pipe |
| 127 | HSR ITEM NO.22.94 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :22.94.4 32 mm nominal bore |
| 128 | HSR ITEM NO. 22.94.5 40 mm nominal bore |
| 129 | HSR ITEM NO. 22.94.6 50 mm nominal bore |
| 130 | HSR ITEM NO.22.98 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end):For vertical pipe connection with terrace ringmain22.98.2 20 mm nominal bore |
| 131 | 22.98.1 25 mm nominal bore |
| 132 | 22.98.3 32 mm nominal bore. |
| 133 | 22.98.4 40 mm nominal bor |
| 134 | HSR ITEM NO.22.109 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. |
| 135 | HSR ITEM NO. 22.111 Providing and fixing PTMT bib cock of approved quality and colour. 22.111.1 15mm nominal bore, 86 mm long, weighing not less than 88 gms |
| 136 | 22.111.3 15 mm nominal bore, 165 mm long, weighing not less than 110gms |
| 137 | HSR ITEM NO.22.112 Providing and fixing PTMT stop cock of approved quality and colour.22.112.3 15 mm nominal bore |
| 138 | HSR ITEM NO. 22.123 Providing and fixing PTMT grating of approved quality and colour. 22.123.1 Circular type22.132.1.1 100 mm nominal dia |
| 139 | HSR ITEM NO.22.126 Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighingnot less than 40 gms |
| 140 | Providing and fixing PTMT soap Dish Holder having length of 138mm,breadth 102mm, height of 75mm with concealed fitting arrangements,weighing not less than 106 gms |
| 141 | HSR ITEM NO.22.128 Providing and fixing Unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 22.128.1 15 mm nominal bore with 30 cm length |
| 142 | 22.128.2 15 mm nominal bore with 45 cm length |
| 143 | HSR ITEM NO. 22.163 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1: 1 (1 cement : 1 fine sand) including testing of joints etc. complete: 22.163.3 200 mm diameter |
| 144 | HSR ITEM NO. 22.164 Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design. 100 mm 22.164.2 150 mm diameter S.W. pipe |
| 145 | HSR ITEM NO. 22.166 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 22.166.2 150 x 100 mm size P type 22.166.2.1 With common burnt clay non-modular bricks of class designation 10.5 |
| 146 | HSR ITEM NO. 22.181 Providing and placing on terrace (at all floor levels) polyethylene water litre 7 8 storage tank, IS: 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 147 | HSR ITEM NO. 22.190 Constructing brick masonry manhole in cement mortar 1 :4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1 :1.5:3 mix (1 cement : 1.5 coarse sand (zone-Ill) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1 :4:8 mix (1 cement : 4 coarse sand (Zone-Ill) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1 :3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :22.190.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weightof cover and frame to be not less than 38 kg (weight of cover 23kg and weight of frame 15 kg) :22.190.1.1 With common burnt clay non-modular bricks of class designation 10 |
| 148 | HSR ITEM NO. 22.190.2 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg).22.190.2.1 With common burnt clay non-modular bricks of each 2211 14097 16308class designation 10.5 |
| 149 | HSR ITEM NO.22.209 Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 150 | HSR ITEM NO. 22.222 Providing, Fixing, Jointing and Testing, uPVC SWR pipes- type a conferming to IS: 13592 to wall, celling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes.22.222.2.2 110 mm, soil Pipe |
| 151 | 22.222.2.4 75 mm, Soil & Waste Pipe |
| 152 | Providing and Fixing on wall face unplasticised- PVC moulded fitting/accesssories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.Bend (87.5\")110 mm bend |
| 153 | 75 mm bend |
| 154 | Y\" Fitting - 75 mm |
| 155 | Single Tee with door - 110mm |
| 156 | Single Tee with door - 75mm |
| 157 | Coupler - 110mm |
| 158 | 75mm |
| 159 | Vent Cowl - 110mm |
| 160 | Vent Cowl - 75mm |
| 161 | ( NS ) Providing, Fixing, Jointing and testing, unplasticized PVC pipes- 10 kg/cm2 confirming to IS: 4985 to wall, celling and floor, approved quality, complete, for waste water drain including jointing with rubbering/solvent/solution and airtight joints, etc. For Wash basin & Kitchen 32mm dia, Pipe |
| 162 | 32mm Bend(45\") |
| 163 | 32mm Bend (90\") |
| 164 | 50mm dia, Pipe |
| 165 | 50mm Bend (90\") |
| 166 | ( NS ) Providing, Fixing, Jointing and testing, of PVC floor Trap with minimum 50mm water seal, making necessary cuttting in slab or floors and making good including supports with cement concrete 1:2:4 complete as approved by Engineer-in-charge. 110mm X75mm X 50mm/40mm (Toilet) |
| 167 | Electrical WorksHSR Item No 20.71 Supply, erection, testing of Ceiling fans IS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge.20.71.1 48\" (1200mm) |
| 168 | 20.71.2 56\" (1400mm) |
| 169 | HSR Item No 20.72 Supplying, errection, testing of Exhaust fan (as per IS code 374) having a each capacity of 45 cubic metre per minute complete with suitable G.I sheet ducting in structure confirming to latest IS specifications complete in all respect to satisfaction of Engineer-in-charge. ( 300 mm ) |
| 170 | HSR ITEM NO. 23.4.1 Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe.23.4.1.1 Group A |
| 171 | 23.4.1.2 Group B |
| 172 | 23.4.1.3 Group C |
| 173 | HSR ITEM NO. 23.4.2 Wiring for Twin control light point with 2 nos , 2-ways, 5 amp. Modular switch GI box and modular face plate in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe.23.4.2.2 Group B |
| 174 | 23.4.2.3 Group C |
| 175 | HSR ITEM NO. 23.4.4Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required. 23.4.4.1 Group A |
| 176 | 23.4.4.2 Group B |
| 177 | 23.4.4.3 Group C |
| 178 | HSR ITEM NO. 23.4.5 Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required 23.4.5.1 Group A |
| 179 | 23.4.5.2 Group B |
| 180 | 23.4.5.3 Group C |
| 181 | HSR ITEM NO. 23.5.6 Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required.23 .5.6.1 1 run of Size 1.50 Sqmm(1/1.40mm) |
| 182 | 23.5.6.31 run of Size 4 Sqmm(1/2.24mm) |
| 183 | 23.5.6.41 run of Size 6 Sqmm(1/2.80mm) |
| 184 | 23.5.6.5 1 run of Size 10 Sqmm(1/3.50mm) |
| 185 | HSR ITEM NO. 23.7.6Supply and erection of PVC CONDUIT ISi marked (Medium) recessed in walVceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete.23.7.6.2 PVC pipe of 25 mm dia. |
| 186 | HSR ITEM NO. 23.8.10Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects.23.8.10.11 & 2 Modules including combined plate for Telephone and data |
| 187 | 23.8.10.2 3 Modules |
| 188 | 23.8.10.34 Modules |
| 189 | 23.8.10.4 6 Modules |
| 190 | 23.8.10.58 Modules |
| 191 | 23.8.10.6 12 Modules |
| 192 | HSR ITEM NO. 23.8.11 Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect.23.8.11.1 5 amp 1 way switch |
| 193 | 23.8.11.2 5 amp 2 way switch |
| 194 | 23.8.11.3 15 amp 1 way switch |
| 195 | 23.8.11.4 5 amp Socket |
| 196 | 23.8.11.5 15 amp 6 pin Socket |
| 197 | 23.8.11.7 step type Fan Regulator 2 modules 300 watt |
| 198 | 23.8.11.8 Telephone Socket outlet modular type |
| 199 | 23.8.11.9 TV Socket outlet modular type |
| 200 | 23.8.11.10 Blanking plate |
| 201 | HSR ITEM NO. 23.9 Erection of exhaust fan in existing opening ,complete with necessary earthling of fan including carriage from PWD store to the site of work. |
| 202 | HSR Item No 23.22.1 Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work.23.22.1.3 TRIPLE POLE MCCB 16 to 100 Amp, 25 K |
| 203 | 23.22.1.10 4 pole MCCB 125 to 160 amp, 25 KA |
| 204 | 23.22.1.11 4 pole MCCB 200 to 250 amp, 25 KA |
| 205 | HSR Item No.-23.22.4 Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respectup to the entire satisfaction of the Engineer-in-Charge of the work. 23.22.4.5TPN DB Horizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing) |
| 206 | 23.22.4.6 TPN DB Horizontal type Double Door 6 way ( 8 incoming 3phase*6 outgoing) |
| 207 | 23.22.4.7 TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing) 23 |
| 208 | 23.22.4.9 TPN DB Horizontal type Double Door 12 way ( 8 incoming 3phase*12 outgoing) |
| 209 | HSR Item No 23.22.5 Supply and erection of miniature circuit breaker 240/415 V in the existing distribution board including making necessary connections. 23.22.5.1 6 amp. to 32 amp Single Pole |
| 210 | 23.22.5.3 6 amp. to 32 amp Double POLE |
| 211 | 23.22.5.7 6 amp. to 32 amp MCB\"s FOUR POLE |
| 212 | 23.22.5.8 40 amp to 63 amp. MCB\"s FOUR POLE |
| 213 | HSR Item No 23.22.6 Supply and erection double pole/Four pole Residual (RCCB/ELCB) on 240/415V, 5Hz. AC supply installed in existing sheet steel enclosures including making necessary connections and bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. 23.22.6.1 DP RCCB 30ma sensitivity , 25 A |
| 214 | 23.22.6.2 DP RCCB 30ma sensitivity , 40 A |
| 215 | HSR Item No 23.22.1 Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work.23.22.1.9 4 pole MCCB 6 amp to 100 amp , 25 K |
| 216 | HSR Item No 23.22.7 Supply and erection of blanking sheet in existing distribution board. |
| 217 | HSR ITEM NO. 23.23.8 Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and sealed in existing pipe/channel and making necessary connection complete in all respect up to the entire satisfaction of the Engineer-in charge of the work23.23.8.1 2 pair telephone wire |
| 218 | HSR Item No 23.24.4 Supply, installation, testing and commissioning of load bank with digital meter module cost of digital Amp. I volt meter with selector switch wiring ( but EXLUDING COST of incoming and outgoing MCCB\"s ) etc.suitable for operation of 240/415 volts AC. Supply with both side cable allay, inter connection and fixing the same in existing MS pedestal/wall complete with all labour and material required for the same up to the entire satisfaction of Engineer-in-Charge of work. 23.24.4.2 Load Bank 8 way 250 amp. |
| 219 | HSR Item No 24.1.3 Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick includingaccessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. |
| 220 | HSR Item No 24.1.1 Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. |
| 221 | HSR Item No 24.1.2 Extra for using salt and char coal/coke for pipe earth electrode as required. |
| 222 | HSR Item No 24.1.5 Extra for charcoal or coke and salt for G. I. plate or copper plate earthelectrode. |
| 223 | HSR Item No 24.1.7 Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/fromearth electrode including soldering etc. as required |
| 224 | HSR Item No 24.1.8 Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for 108 connections etc. as required with all labour and material |
| 225 | HSR Item No 24.2.5 Laying and fixing of cable on surface/ cable tray etc as required:- 24.2.5.2 16 Sq mm to 35 sqmm 2 to 4 Core |
| 226 | 24.2.5.3 50 Sq mm to 150 sqmm 2 to 4 Core |
| 227 | HSR Item No 24.2.7 Supply and erection of suitable compression type brass cable glands for underground Cable :- 24.2.7.2 10 sqmm to 16 sqmm Cable 2 to 4 Core |
| 228 | 24.2.7.3 25 sqmm to 50 sqmm Cable 2 to 4 Core |
| 229 | HSR Item No 24.2.8 Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work.24.2.8.4 16 sqmm |
| 230 | 24.2.8.5 25sqmm |
| 231 | 24.2.8.6 35sqmm |
| 232 | 24.2.8.7 50sqmm |
| 233 | NS Supplying and drawing co-axial TV cable RG-6 graded, 0.7 mm solid copper braid and protected with PVC sheath in the existing surface/recessed steel/PVC conduct a required. |
| 234 | NS Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit as required. 4x16sq.mm + 2x6 sqmm earth wire |
| 235 | NS Supplying and fixing Cable End Box ( Loose wire box )( IP 43 ) suitable for following triple pole and neutral, sheet steel , MCB distribution board 240 V , on surface/ recess complete with testing and commissioning etc. as required.For 4 way, Double door TPN MCBDB |
| 236 | For 6 way, Double door TPN MCBDB |
| 237 | For 8 way, Double door TPN MCBDB |
| 238 | NS Manufacturing testing and supplying following 1.1kv grade, heavy duty XLPE insulated , FRLS type armoured cables suitable for 415V, 50Hz, AC system with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring ( round or flat as mentioned ) and with all components as mentioned in BOQ specification and schedule , complete as required.3.5 C x 70 sqmm alluminium conductor, A2XWY |
| 239 | 3.5 C x 50 sqmm alluminium conductor, A2XWY |
| 240 | 4 C x 35 sqmm alluminium conductor, A2XWY |
| 241 | 4 C x 25 sqmm alluminium conductor, A2XWY |
| 242 | 4 C x 16sqmm alluminium conductor, A2XWY |
| 243 | NS Supply and fixing cable End box ( Loose wire box ) suitable for triple pole and neutral sheet steel, vertical MCB distribution board 415 V, on surface/ recess complete with testing and commissioning etc. as required |
| 244 | NS Installation, testing and commissionning of pre-wired, fluorescent fitting/ compact fluorescent fitting/LED fitting of all types, complete with all accessories and tube/lamp/LED etc. directly on celling/wall/false ceiling with GI Chain included for fixing wherever rquired, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable an earthing etc. as required. |
| 245 | NS Supplying an fixing PVC batten/ angle holder including connections etc. as required. |
| 246 | NS Supply, Installation, Testing an acommissioning of recess/Surface mounting round 12 watt, cut out Min 125mm,LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflector and driver set, suitable for 24 Hr continuous Operation,complete in all respec. Make : Philips Cat No. SM25 1C LED 125-6500 PSU WH of Equivalent. |
| 247 | NS Supply, Installation, Testing and Commissioningof 20W Bracket light fixture specification complete as per architecturaldesign. Make : Philips , CatNo. 31459 or Equivalent. |
| 248 | NS Supply Installation, Testing and Commissioningof Mirror Light Fixture suitable for 11 W LED complete in all respects as required Make: philips Cat No.- Ultima or Equivalent. |
| 249 | NS Supply, Installation, Testingf and commissioning of LED Tube Light 20 watt Polycarbonate tube light complete including tube etc suitable for both surface & Surface complete in all respects. Make: Phillips CatNo. BN021C LED20S PSU CW GR S2 or Equivalent. |
| 250 | NS Supply, Installation, Testing and commissioning of 7W Bulkhead light fixture with specification complete as per architectural design Make: Phillips Cat No. WT140W LED 7S CW PSU S1 PC or Equivalent. |
| 251 | NS Supply and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part 2 complete with fitting andcutting, jointing etc, direct in ground ( 75 cm below ground level ) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required. 120 mm dia ( OD - 120 mm & ID - 103 mm nominal ) |
| 252 | NS Supplying and drawing following pair FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/ recessed steel / PVC conduit as required.10 pair |
| 253 | NS Supplying and fixing of telephone distribution board ( tag blocks ) in hinged type MS box duly powder coated complete with bakelite sheet with termination of incoming and outgoing telephone wire etc. complete as required. ( a )10 pair telephone tag block |
| 254 | NS Supply , installation testing and commisoning of 70W LED flood light with starter and other accessories conferming to IP 65/66 protection complete in all respect as required. Make : Philips Cat no.BVP120 LED CW FG S1 PSU GR or Equivalent |
| 255 | NS Supply and installing following size of perforated hot Dipped Galvanised iron cable tray ( Galvanisation thickness not less than 50 micron ) with perforation not more than 17.5 % in convenient sections, joined with connector, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts etc. as required. ( a ) 450 mm width x 50 mm depth x 2 mm thickness |
| 256 | NS Supply and installing following size of perforated hot Dipped Galvanised iron cable tray\" bends \" ( Galvanisation thickness not less than 50 micron ) with perforation not more than 17.5 % in convenient sections, joined with connector, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts etc. as required. ( a ) 450 mm width x 50 mm depth x 2 mm thickness |
| 257 | NS Supply, installation testing & commisioning of 5 KVA UPS at 0.09 input power factor with SNMP card, compatible for BMS connectivity on backnet/ MODBUS . Inbuilt isolation transformer as per specification given in the document with following broad features. THD shall be less than 3 % in the entire loading range. UPS shall carry design output at 40 - deg. Shall have soft start and hold of for incoming supply.Invertar capabillity to supply 150% load for 5 sec. Single phase input and single phase outputShall not allow deep discharge of the battery and shall not go to 10.5 volts in case of 12 volts cells.Battery shall be external type with rack and suitable for 30 minute backup on 100% load. Suitable size of copper cable between UPS and battery bank shall be provided. with battery. UPS described as above |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender