Tender For Rep Maintenance Bldg Security Light Fittings Earthing Aviation Lights Elect Supply High Mast Lights Misc Electrical Wks And Rep Maint Ext Elect Incl Lt Oht Ug Lt Poles Street High Mast Lt Panels Incl Apfc Panels Earthing North Runway Age Emi Ge, Vasco-Da-Gama-Goa

Military Engineer Services-MES has published Tender For Rep Maintenance Bldg Security Light Fittings Earthing Aviation Lights Elect Supply High Mast Lights Misc Electrical Wks And Rep Maint Ext Elect Incl Lt Oht Ug Lt Poles Street High Mast Lt Panels Incl Apfc Panels Earthing North Runway Age Emi Ge. Submission Date for this Tender is 06-12-2022. Electrification Work Tenders in Vasco-Da-Gama Goa. Bidders can get complete Tender details and download the document.




Tender Notice

34754655
Corrigendum : Tender For Rep Maintenance Bldg Security Light Fittings Earthing Aviation Lights Elect Supply High Mast Lights Misc Electrical Wks And Rep Maint Ext Elect Incl Lt Oht Ug Lt Poles Street High Mast Lt Panels Incl Apfc Panels Earthing North Runway Age Emi Ge
Open Tender
Indian
Goa
Vasco-Da-Gama
06-12-2022

Tender Details

Tender For Rep Maintenance Bldg Security Light Fittings Earthing Aviation Lights Elect Supply High Mast Lights Misc Electrical Wks And Rep Maint Ext Elect Incl Lt Oht Ug Lt Poles Street High Mast Lt Panels Incl Apfc Panels Earthing North Runway Age Emi Ge

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 22-Nov-2022 Revised BOQ BOQ 29-11-2022
2 22-Nov-2022 Revised BOQ and Tender Page Corrigendum Other 29-11-2022
3 29-Nov-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 06-12-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 100000.0 /-
Tender Value
INR 50 Lakhs /-

BOQ Items

NAME OF WORK : REPAIR / MAINTENANCES OF BLDG SECURITY LIGHT FITTINGS, LIGHTENING CONDUCTORS, EARTHING, AVIATION LIGHTS, FLAME PROOF ELECTRIC SUPPLY, HIGH MAST LIGHTS AND MISC ELECTRICAL WORKS FOR BLDGS AND HANGARS AND REPAIR / MAINTENANCES OF EXTERNAL ELECT INCLUDING LT OHT LINES, UG CABLES, LT POLES STREET / SECURITY / PERIMETER / HIGH MAST LIGHTS, LT PANELS INCLUDING APFC PANELS, EARTHING AND CONNECTED WORKS AT NORTH SIDE RUNWAY UNDER AGE E/M - I OF GE (NW) VASCO
Sl. No. Item Description
1REPAIR / MAINTENANCES OF BLDG SECURITY LIGHT FITTINGS, LIGHTENING CONDUCTORS, EARTHING, AVIATION LIGHTS, FLAME PROOF ELECTRIC SUPPLY, HIGH MAST LIGHTS AND MISC ELECTRICAL WORKS FOR BLDGS AND HANGARS
2S & F in repairs integral LED aviation light comprising of aluminium housing with polycarbonate enclosure with necessary fixing arrangement such as GI pipe, fixing clamp, brackets, etc., complete all as specified and directed by Engineer-in-Charge.
3S & F in repairs 1x60 watts LED building security light made up of pressure die cast housing with toughned glass and individual LEDs with secondary optics and IP66 protection for building security lights all as specified and directed by Engineer-in-Charge.
4M & L for in repairs Street light bracket made out of GI tubing 32/40 mm dia, light grade bend to shape suitable for below mentioned security light fitting with necessary MS clamps with one coat of red oxide and two coats of aluminium paint including nut, bolt, washers etc all as specified and directed by Engineer-in-Charge.
5Supply and fixin repairs LED flood light fitting 200 watts made in pressure die cast aluminium housing and reflector and enclosed with toughened glass with IP66 protection complete with all accessories such as LED"s and electronic driver, internally prewiredincluding necessary fixing arrangement on PCC pole / high mast pole / wall by providingMS angle iron bracket 50x50x6mm of adequate length as per site requirement with MS flat iron clamp 32x6 mm with necessary nuts, bolts and washers etc and making cable connection all as specified and directed.
6Supply and fixin repairs LED flood light fitting 240 watts made in pressure die cast aluminium housing and reflector and enclosed with toughened glass with IP66 protection complete with all accessories such as LED"s and electronic driver, internally prewiredincluding necessary fixing arrangement on PCC pole/high mast pole/wall by providingMS angle iron bracket 50x50x6mm of adequate length as per site requirement with MS flat iron clamp 32x6 mm with necessary nuts, bolts and washers etc and making cable connection all as specified and directed by Engineer-in-Charge.
7S & F in repairs wind LED wellglass luminaires 1x30 watts Energy saving, environment friendly & robust open type verticalLED luminaire with high power LED as light source all as specified and as directed.
8Fixing only LED High bay luminaires of any make any type of capacity 80 W to 140 W in hangar upto height of 18 mtr including making necessary electric connection and removal of old unserviceable lights and depositing to MES yard comlete all as specified and directed by Engineer-in-Charge. Note :- (a) Highbay lights will be supplied under Sch B items.
9S & F in repairs LED High bay luminaires 1x195 watts Energy saving, environment friendly & robust open type vertical Highbay LED luminaire with high power COB LED as light source all as specified and directed by Engineer-in-Charge.
10S & F in repairs LED High bay luminaires 1x200 watts Energy saving, environment friendly & robust open type vertical Highbay LED luminaire with high power COB LED as light source all as specified and directed by Engineer-in-Charge.
11Taking down unserviceable any type of copper / aluminium sub main wiring of any type / size / core type complete including conduits/casing caping etc, removing the materials / debris and making good the disturbed surfaces of walls, floors and ceilings etc to match with the original existing finish all as specified and directed by Engineer-in-Charge.
12M & L for sub main wiring with two runs of single core 2.5 Sqm, FRLSCopper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non- metallic rigidPVC casing caping (double interlock type) of suitable width medium dutywith all accessories such as Tees, elbows,junction boxes etc, as required fixed on wall along with one run of 2.5 Sqmm single core PVC FRLSinsulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc all as specified and directed by Engineer-in-Charge. (Note :- Two runs of cable, one run of earth continuity conductor and one run of PVC casing caping/conduit shall be measred as one unit)
13All as per item No 11.00 here in before, but two run of single core 4 sqmm and one run of 4 sqmm cables as earth continuity conductor.
14All as per item No 11.00 here in before, but two run of single core 6 sqmm and one run of 4 sqmm cables as earth continuity conductor.
15All as per item No 11.00 here in before, but four run of single core 6 sqmm and two run of 4 sqmm cables as earth continuity conductor.
16All as per item No 11.00 here in before, but four run of single core 10 sqmm and two runs of 6 sqmm cables as earth continuity conductor.
17All as per item No 11.00 here in before, but four run of single core 16 sqmm and two runs of 10 sqmm cables as earth continuity conductor.
18S & F in repairs Switch Flameproof WP Rotary type with termination box in LM6, 15A single pole 250V all as specified and directed by Engineer-in-Charge.
19S & F in repairs Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth all as specified and directed by Engineer-in-Charge.
20Supply and fixing LED light fitting 30 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protectio with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
21Supply and fixing in repairs flame proof exhuet fan motor with body of size 300 mmsweep complete all as specified and directed by Engineer-in-Charge.
22Supply and fixing in repairs flame proof exhuet fan sweep of size 300 mm sweep complete all as specified and directed by Engineer-in-Charge. Note:- Fan Blade make and size should be supply with the mach of under relivent item of Sch Aserial No 22 as above.
23Taking down unserviceable any type of Main Switch, DB"s including MCBs incl wooden/GI/MS sheet board etc and removing from site and making good the disturbed surface of wall etccomplete all as specified and directed by Engineer-in-Charge.
24S & F in repairs sheet metal enclosure SPN with a two pin and earth plug and socket complete with one SP MCB 20 Amps complete all as specified.
25All as per item No 23.00 here in before but MCB DB TPN 4 way DB 415 V with 200 A rated busbar triple pole.
26S&F in repairs MCB DB SPN 8 way DB 230 V with 200 A rated bus bar double door typecomplete all as specified and directed by Engineer-in-Charge.
27All as per item No 25.00 here in before but MCB DB SPN 4 way DB 230 V with 200 A rated busbar.
28All as per item No 25.00 here in before but MCB DB SPN 12 way DB 230 V with 200 A rated busbar.
29S&F in repairs MCCB DB TPN, 8 way, (MCCB + 24 way O/G) double door, vertical type provision one MCCB of 100 amps breaking capacity 18 KA, 4 pole without MCBcomplete all as specified and directed by Engineer-in-Charge.
30S & F in repairs vertical type MCCB DB TPN 4 way, 415 volts, double door, factory made sheet metal enclosure with 200 amps rated copper bus bar, neutral bar, earth bar painted with epoxy based powder coated suitable for mounting MCCB FP 63 amps as incomer and MCB TP/SP as outgoings complete with IP-43 protection and concealed in wall including making incoming and outgoing cable/wire connectionscomplete all as specified and directed by Engineer-in-Charge.
31S & F in repairs MCB TPN32 amps 415 volts C curve, 50 HZ AC 10 KAcomplete all as specified and directed by Engineer-in-Charge.
32S & F in repairs MCB TPN40 to 63 amps 415 volts C curve, 50 HZ AC 10 KAcomplete all as specified and directed by Engineer-in-Charge.
33S & F in repairs MCB TP 32 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified and directed by Engineer-in-Charge.
34S & F in repairs MCB TP 40-63 amps 415 volts C curve, 50 HZ AC 10 KAcomplete all as specified and directed by Engineer-in-Charge.
35S & F in repairsMCB SPN06 -32 amps 230 volts C curve, 50 HZ AC 10 KAcomplete all as specified and directed by Engineer-in-Charge.
36S & F in repairsMCB SP 06 to 32 amps 230 volts C curve, 50 HZ AC 10 KAcomplete all as specified and directed by Engineer-in-Charge.
37Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjutable type 125 to160 Amps with breaking capacity 25 KA complete including necessary connection with suitable size aluminum/copper cable lugs complete all as specified and directed by Engineer-in-Charge.
38Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjutable type 200 Amps with breaking capacity 25 KA complete including necessary connection with suitable size aluminum / copper cable lugs complete all as specified and directed by Engineer-in-Charge.
39Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjutable type 250 Amps with breaking capacity 25 KA complete including necessary connection with suitable size aluminum / copper cable lugs complete all as specified and directed by Engineer-in-Charge.
40Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjutable type 400 Amps with breaking capacity 50 KA complete including necessary connection with suitable size aluminum / copper cable lugs complete all as specified and directed by Engineer-in-Charge.
41Supply and fix in repairs MCCB of 100 to 125 A breaking capacity 18 KA , 4 pole thermal megnetic release, compact type suitable for MCCB DB Vertical type as incoming in the existing DB"s c complete all as specified and directed by Engineer-in-Charge.
42Supply and fix in repairs MCCB of 63 A breaking capacity 18 KA, 4 pole thermal megnetic release, compact type suitable for MCCB DB Vertical type as incoming in the existing DB"s c complete all as specified and directed by Engineer-in-Charge.
43Supply and Fixing Energy efficient surface Mounted LED Luminire 18/20 watts 4" long, with acrylic cover complete with all accessories incl necessary two core copper wire for connection from ceiling rose to connector of approx length 0.75 mtr and removal of old unserviceable lightscomlete all as specified and directed by Engineer-in-Charge.
44Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete and necessaryfixing arrangementat any height and removing old unserviceablecomplete all as specified and directed by Engineer-in-Charge.
45Supply & fix recess mounting high lumen LED flat panel 1" x 1" 18 Watt, white powder coated CRCA housing with highpower LED, aluminium front frame with flat white high transmission acrylic cover, internally prewired, 230V, complete with all accessories such as electronic driver, LED strip, connector block etc. and necessaryfixing arrangementat any height and removing old unserviceable item complete all as specified and directed by Engineer-in-Charge.
46Supply & fix in repairs recess mounting high lumen LED flat panel 4"x1" 36 Watt, white powder coated CRCA housing with highpower LED, aluminium front frame with flat white high transmission acrylic cover, internally prewired, 230V, complete with all accessories such as electronic driver, LED strip, connector block etc.and necessaryfixing arrangementat any height and removing old unserviceable itemcomplete all as specified and directed by Engineer-in-Charge.
47S&F in repairs LED light fitting 1x18 watts Surface mounted LED downlighter in powder coated white finish with integrated electronic drivercomplete all as specified and directed by Engineer-in-Charge.
48S & F in repairs Fluorescent tube light fitting. 1x36W flameproof type FLP-WP made of aluminium alloy LM6, with electronic ballast, bipin holders, connector block, etc. complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge.
49S & F in repairs PVC Casing & Caping double lock type of as required width (not less than 20/25 mm in width) ISI marked medium grade white colour with all accessories of same grade fixed on wall/ceiling etc. complete all as specified and as directed.
50M & L for Earthing complete with GI earth plate, electrode,600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) filled with common salt and charcoal and connected to GI earth strip 32x 6 mm thick dia by means of GI nuts, bolts, & washers as shown in electrical plate No. 5 of SSR Part-I and Connected to earthing test point all as specified and including necessary PCC earth pit chamber of 1:3:6 and chamber cover of 50mm thick PCC 1:2:4 with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover, watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 40 mm dia unto 7.5 from the earth plate electrode & refilling of soil etc including necessary excavation & earth work in any strata and PCC chamber all as specified and directed by Engineer-in-Charge including demolish existing earth pit taking out old materials complete all as specified and directed by Engineer-in-Charge.
51M & L for Earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to copper strip size 20 x 3 mm thickby mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earthing strip shall be provided with GI pipe light grade 32 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamberin cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and directed by Engr-in-charge.
52M & L for Earthing complete with Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earth lead shall be provided with GI pipe light grade 20 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamberin cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and directed by Engr-in-charge.
53S & F copper strip 20x3 mm Earth continuity conductor fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified and directed by Engineer-in-Charge.
54Supply and wrapping of LT insulation tape 12 mm width in 5 mtr roll complete all as specified and directed by Engineer-in-Charge.
55S & F in repair Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed by Engineer-in-Charge.
56S & F Perforatted cable Tray made out of GI Sheet of 14 SWG thickness and 40 to 50 mm depth hot dipped in various width sizes including accessories like couplar plate, nut bolts, washers clamps, wall bracket up/down elbows, bends tees equal distances on wall/floor/through wall crossing and making good the surface, complete all as specified.
57S&F in repair informatory sign boards/display chart with single side writing over foam sheet of 4 mm thick (maximum size 2 mtr x 1 mtr) fixed on wall with screw. nuts and bolts etc. complete all as specified and directed by Engineer-in-Charge. Note :- wright matters will be provided by departmaint as per requirment.
58M & L for painting of LT panel of any description with one coat of synthetic enamel paint of standard colour code over the existing painted surfaces after preparing the old painted surfaces by using spray gun and marking of all incoming and out goining MCB/MCCBS complete all as specified and directed by Engineer-in-Charge.
59S & F in repairs capacitor of 2.5/3.15 mfd capacity for ceiling fan of any sweepcomplete all as specified and directed by Engineer-in-Charge.
60S&F in repair Analog time switch fixed in timer panal including connectionwith screw nuts and bolts etc. complete all as specified and directed by Engineer-in-Charge.
61Taking down Aluminum strip of size 25 x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground and refixing in the same location with new nuts and bolts, screwsof suitable size and length and connected to air termination rod on op of the hangarcomplete all as specified and directed by Engineer-in-Charge.
62REPAIR / MAINTENANCES OF EXTERNAL ELECT INCLUDING LT OHT LINES, UG CABLES, LT POLES STREET / SECURITY / PERIMETER / HIGH MAST LIGHTS, LT PANELS INCLUDING APFC PANELS, EARTHING AND CONNECTED WORKS AT NORTH SIDE RUNWAY UNDER AGE E/M - I
63Taking out LT UG cable from any type of soil and sizeall as directed by Engineer-in-Charge.
64Supply and laying under ground LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 10 Sq mm, 4 core, with aluminium conductor, ISI marked as per IS : 7098( Part-1) along with suitable size aluminium cable lugs, gland if required and jointed in any description complete all as specified.
65All as per item No 2.02 here in before but of size 4 core 16 sqmm
66All as per item No 2.02 here in before but of size 4 core 25 sqmm
67All as per item No 2.02 here in before but of size 3 1/2 core 35 sqmm
68All as per item No 2.02 here in before but of size 3 1/2 core 50 sqmm
69All as per item No 2.02 here in before but of size 3 1/2 core 70 sqmm
70All as per item No 2.02 here in before but of size 3 1/2 core 95 sqmm
71All as per item No 2.02 here in before but of size 3 1/2 core 120 sqmm
72All as per item No 2.02 here in before but of size 3 1/2 core 150 sqmm
73All as per item No 2.02 here in before but of size 3 1/2 core 185 sqmm
74All as per item No 2.02 here in before but of size 3 1/2 core 240 sqmm
75All as per item No 2.02 here in before but of size 3 1/2 core 300 sqmm
76Note for item No 2 to 13:- 1. Excavation, Concrete cable protection cover, pipe, PCC work for road crossing / hard standing and Sand for cushioning will be measured and paid separately. 2. Cost of glands,aluminium cable lugs (eye lid/barrel / bottle neck type/ring type or any shape), new nut, bolt and washers of required size / description are deemed to include in this rate.
77S & F perforated cable tray made out of GI Sheet of 14 SWG thickness and 40 to 50 mm depth hot dipped in various width sizes including accessories like couplar plate, nut bolts, washers clamps, wall bracket up/down elbows, bends tees equal distances on wall/floor/through wall crossing and making good the surface, completeall asspecified and as directed.
78S&F in repair reflective informatory sign boards with single side writing as per IRC 67 made of high intensity grade sheeting, fixed over aluminium sheet3 mm thick, supported on angle iron / GI pipes fixed in PCC including welding and painting with two coats of synthetic enamel paint over a coat of primer complete all as directed. (MS Angle/Square tube iron work /GI pipe / GI Angle PCC will be measured and paid seperately under relevent item of this schedule)
79Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m
80Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m
81S & F in repair Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15 cm size all as directed.
82Material and labour for fault finding of LT cables of anysizeany length with fault detective machine by thumbing method and suitablevoltage and all as permanufactures instructions including providing straight through joint and additional cable ofsame existing size suitable to site requirement complete all as specified and directed by Engineer-in-Charge.
83S& F in repairs rolled Mild steel plates of FE 410 -10(Gde-E 250)(Plain) of (Cable duct cover) A grade as required size including cover welded aroud with MS flat iron of required size with locking arrangements including painting with two coats of synthetic enamel paint over a coat red oxide primer.
84M & L for repairing the existing LT panel/ Feeder Pilller Box any type or sizeby taking proper shutdown from power house and disconnecting and re-connecting cables connection both in coming and outgoing using appropriate size of thimbles, making proper welding, drilling for smooth functioning of panel / feeder door, replacement of unserviceable aluminium bus barof suitable capacity / size as per existing includingbakelite insulators, terminals, base plate, necessay nuts, bolts & washers, locking arrangement complete all as specified and directed. (Note: Necessary accessories like MCCB / MCB, CT coil, ammeter, voltmeter, indication lamp, selector switch etc shall be measured and paid separately as supply & fixing under respective item)
85S & F MCCB four pole 63 to 100Amps with breaking capacity 25 KA , 415 Volts, thermal & magnetic release including making all incoming/ outgoing connections complete all as specified and directed by Engineer in Charge.
86All as per item No. 2.23 but 125 Amps with breaking capacity 25 KA.
87All as per item No. 2.23 but 160 Amps with breaking capacity 25 KA.
88All as per item No. 2.23 but 200 Amps with breaking capacity 35 KA.
89All as per item No. 2.23 but 250 Amps with breaking capacity 35 KA
90All as per item No. 2.23 but 400 Ampswith breaking capacity 35 KA.
91S & F MCCB 3 pole 100 Amps with breaking capacity 25 KA , 415 Volts, thermal & magnetic release including making all incoming/ outgoing connections fixed in repair complete all as specified and directed by Engineer in Charge.
92All as per item No. 2.29 but 125 Amps with breaking capacity 25 KA.
93All as per item No. 2.29 but 160 Amps with breaking capacity 25 KA.
94All as per item No. 2.29 but200 Amps with breaking capacity 35 KA.
95All as per item No. 2.29 but250 Amps with breaking capacity 35 KA.
96S & F Ampere meterdigital type of ratio 0-500 Amp, size 95 Sqmm square type including making incoming /outgoing connections complete all as specified and directed.
97S & F Voltmeterdigital type of ratio0-415 volt, size 95 Sqmm square type including making incoming / outgoing connections complete all as specified and directed.
98M & L for selector switch rotary type including making connections, complete all as specified and directed.
99M & L for indicator lamp assembly LED type with red / green / blue including makingconnections complete all as specified and directed.
100M & L for Current transformer (CT) ratio 100/5 including making connections complete all as specified and directed.
101Repair/maint ofCapacitor bank APFCpanel of10 KVAr to150 KVAr, Disconnecting and taking out U/S LV capacitor, Protection brunch,Cooling fan,connectors, Power contactors, Controler, MCB etcfrom housing andincluding connection and testing to maintPF above 0.95 complete. (Capacitors and other itemsare paid seperatly in respective items.)
102S & F TP MCB 63 Amps, with 10 kA breaking capacity complete all as specified & directed.
103S & F TP MCB 40 Amps, with 10 kA breaking capacity complete all as specified & directed.
104S & F TP MCB 32 Amps, with 10 kA breaking capacity complete all as specified & directed.
105S & F power factor corrector relay upto 8 stage with programmingcomplete all as specified.
106S & FCapacitor duty contactor 3 pole, 3 KVAr, 1 NO 1 NC complete all as specified & directed.
107S & FCapacitor duty contactor 3 pole, 5 KVAr, 1 NO 1 NC complete all as specified & directed.
108S & F Capacitor duty contactor 3 pole, 8.5KVAr, 1 NO 1NC complete all as specified & directed.
109S & F Capacitor duty contactor 3 pole, 10 KVAr, 1 NO 1 NC complete all as specified & directed.
110S & FCapacitor duty contactor 3 pole, 12.5 KVAr, 1 NO 1 NC complete all as specified & directed.
111S & FCapacitor duty contactor 3 pole, 20 KVAr, 1 NO 1NC complete all as specified & directed.
112S & FCapacitor duty contactor 3 pole,25 KVAr, 1 NO 1NC complete all as specified & directed.
113S & F PhiCap heavy duty Capacitor 1 to 4 KVAR, 3 phase, 415 Volts complete all as specified.
114S & FPhiCap heavy duty Capacitor 5-15KVAR, 3 phase, 415 Volts complete all as specified.
115S & F PhiCap heavy duty Capacitor 20 -25 KVAR, 3 phase, 415 Volts complete all as specified.
116M & L for cleaning of installation/ substation including clearing of vegitation, wild growth and trimming of grass etc around the installation compound and removing rubbish off the premises complete all as specified and as directed.
117M & L for rubbing rusted surface of LT panel/ feeder pillerboxes of various sizes installed in various sub stations, cleaning the inner and outer surface of panel/ feeder piller box and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer including markingname of incomming and outging connection on LT panel complete all as specified and directed.
118M & L for cleaning of substation cable duct after removing HT/LT cable from duct by taking proper shutdown from power house including filling of new river bed fine sand under and around HT/LT cable to provide sand cushioing complete all as specified anddirected.
119M & L in repair for heat shrinkable straight through joint for PVC/XLPE insulated armoured cable of size upto 50 Sqmm 3.5/4 core complete all as specified and as directed.
120All as per serial item No. 2.57 above but LT cable size of 70 to 150 Sqmm
121All as per serial item No.2.57 above but LT cable size of 185 to 300 Sqmm
122M&L for Electric yard gravelling of 15.0 cm (llose thickness) by broken stone of 40 mm size in and around two pole/ four pole structure/ substation complete all as specified and directed.
123Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep in hard / dense soil,getting out and levelling of bottom surface to required level for laying UG cable / errection of poles / pipes all as specified.
124Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep in soft / disintegrated rock getting out and levelling of bottom surface to required level for laying UG cable / errection of poles / pipes all as specified.
125All as per item No. 2.62 above but n.exc. 3.00m in depth and n.exc 1.5m in width in soft / disintegrated rock for errection of poles all as specified.
126Excavation in trenches by cutting of road crossing /PCC hard standing, under boundary wallfor laying of pipe/cable including making good the existing surface with same finish to match the original finishall as directed by Engr-in-Charge.
127Returning filling in excavated earth work including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any strata
128Removing excavated soil to a distance n.exc 50m, depositing where directedat a level n.exc 1.5M above the starting point
129Supply/ fillingdry river sand/m-sand in trenches for cable protection All as SSR Part I. NOTE : Punned thickness only will be measured & Paid
130Supply and laying un-reinforced precast concrete cable cover LV type 1flate size 250 x 150 x 40 mm
131Supply and lay Double walled corrugated pipe (DWC), heavy duty 77/63 mm bore for cable protection as a guard pipe including required accessories etc. complete as specified and directed.
132Supply and lay Double walled corrugated pipe (DWC), heavy duty 110/95 mm bore for cable protection as a guard pipe including required accessories etc. complete as specified and directed.
133Supply and lay GI Pipe medium grade 50 mm bore for cable protection as a guard pipe including required accessories etc. complete as specified and directed.
134Supply and lay GI Pipe medium grade 80 mm bore for cable protection as a guard pipe including required accessories etc. complete as specified and directed.
135Supply and lay GI Pipe medium grade 100 mm bore for cable protection as a guard pipe including required accessories etc. complete as specified and directed.
136M & L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate including use and waste of form work of concrete for any description incl preparation work is necessary all as directed.
137M & L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate including use and waste of form work / mass concrete for coping of poles / using at any description all as dirceted.
138M & L Earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick, buried directly in ground vertically earth pit not less than 2.25 mtr deep below the ground level with top to edge of the plate n. less than 1.5 mtr below ground level connected to galvanized iron strip 25 x 4mm as earthing lead by means of blots, nuts, check nut and washer of galvanized steel, includingnecessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and RCC cover and light grade GI pipe 40 mm dia pipe of requiredlength for protection of GI wire and water funnel and wire mesh with GI pipe medium grade 20mm dia etc complete all as per electrical plate No 3 of SSR part - I and all directed including connections and testing on completion including dismantling old earthing.
139M & L for Earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to copper strip size 20 x 3 mm thickby mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR Part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earthing strip shall be provided with GI pipe light grade 32 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamberin cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and directed by Engr-in-charge.
140Taking down and dismantling old unserviceable panel board any model, make, size including all acessories from various location complete.
141Supply and fix in repair aluminium cable lugs for the following size of cable
142(a) 16 Sqmm cable
143(b) 25 Sqmm cable
144(c) 35 Sqmm cable
145(d) 50 Sqmm cable
146(e) 70 Sqmm cable
147(f) 95 Sqmm cable
148(g) 120 Sqmm cable
149(h) 150 Sqmm cable
150(i) 185 Sqmm cable
151(j) 240 Sqmm cable
152(k) 300 Sqmm cable
153(l) 400 Sqmm cable
154Dismantling stay assembly complete all as directed
155Material and labour for stay assembly 20 mm dia complete with accessories as shown in electrical plate No. 1 completeall as specified and directed. (Note : excavationand concrete shall be measured separately)
156S & F in repairs cross arms bracing support, clamps and back plate fabricated from structural steel sections including nuts,bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat of red oxide zinc chrome, one under coat and one finishing coat of aluminium paint all as specified and directed.
157M & L for Street light bracket made out of GI tubing 40 mm dia, light grade bend to shape suitable for above mentioned security light fittings with necessary MS clamps with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers etc including taking out old unserviceable complete as specified.
158M & L in repair LED decorative post top lantern light with diffuser and painted aluminium deflector 60 watt
159Supply and fixin replacement of 60 Watt LED street light with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED"s must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 100 lumen/Watt (Minimum lumen output of luminarie should be 6000 Lumens)The luminarie should have 5 KV surge protection,PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided.The manufactures LOGO must be embossed/Engraved in the housing of the luminarie complete all as specefied and directed by Engineer-in-Charge.
160S & F in repair cable junction boxes IP 66 protected “halogen free and weather proof” suitable for out door type ( with metric knockouts for cable entry) of size 139 x 119 x 70 mm incl necessary suitable size terminal connector single phase with neutral system mounted on saddles of suitable length and provn of aluminium cable lugs for incoming & out going LT cable connections with junction box fixing clamps made up of MS flat, nut and bolt on poles complete all as directed.
161S & F in repair cable junction boxes IP 66 protected “halogen free and weather proof” suitable for out door type ( with metric knockouts for cable entry) of size 250 x 200 x 105 mm incl necessary suitable size terminal connector single phase with neutral system mounted on saddles of suitable length and provn of aluminium cable lugs for incoming & out going LT cable connections with junction box fixing clamps made up of MS flat, nut and bolt on poles complete all as directed.
162Supply and fix in replacement of25 Watt LED street light with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED"s must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 100 lumen/Watt. Luminarie should have top maintainable driver compartment for easy access to driver during maintenance.The driver used must be a constant current driver with efficiency of > 85%.The manufactures LOGO must be embossed /Engraved in the housing of the luminarie complete all as specefied and directed by Engineer-in-Charge.
163M & L for preparation of old cement coated surface, cleaning the surface of the RCC street light Pole (LT) above the ground level incl coping area with 2 coats of ACC exterior emulsion paint over a coat of cement primer after preparation of surface including 12 cm black paint around the pole numbers/ letters in white.
164M & L prepration of old painted surface of LT cross arm,clamps etc and applying one coat of red oxide primer and 2 coats of aluminium paint for cross arms any numbers of each pole including clamps etc all as directed.
165Supply and Fix on High Mast/wall/ pole in repair 1 x 300Watt LEDFlood light luminarie withhigh pressure die cast housing with lens, IP 66 protectedwith all accessories and chain system and all as specified and directed by Engineer-in-Charge.
166Supply and Fix on High Mast/ wall / pole in repair 1 x 200 Watt LEDFlood light luminarie withhigh pressure die cast housing with lens, IP 66 protectedwith all accessories and chain system and all as specified and directed by Engineer-in-Charge.
167Supply and Fix on High Mast/wall/ polein repair 1 x 120 Watt LEDFlood light luminarie withhigh pressure die cast housing with lens, IP 66 protectedwith all accessories and chain system and all as specified and directed by Engineer-in-Charge.
168Supply and fixin replacement of 180 Watt LED street light with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED"s must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 100 lumen/Watt (Minimum lumen output of luminarie should be 6000 Lumens)The luminarie should have 5 KV surge protection,PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided.The manufactures LOGO must be embossed/Engraved in the housing of the luminarie complete all as specefied and directed by Engineer-in-Charge.
169Supply and Fix in replacement onload manual change over switch 630 Amps, 4 pole, 415 V including sheet Steel enclosure confirming to IEC 60947-3
170Supply and fix in repair LED driver with transformer suitable for 25 to 60 watts LEDstreet/ Flood / high bay light fitting as per site requirement and existing model all as specified and directed by Engineer-in-Charge.
171All as per item No. 3.08 here in before but of capacity 70 to 90 watts LED fittings complete all as specified and directed by Engineer-in-Charge.
172All as per item No.3.08 here in beforebut of capacity 120 to 250 watts LED fittings complete all as specified and directed by Engineer-in-Charge.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail