Tender For Sarangpur Village Water Supply Scheme , Tq.Mehkar Dist.Buldana

BOQ

NAME OF WORK :- SARANGPURVILLAGE WATER SUPPLY SCHEME , TQ.MEHKAR DIST.BULDANA
Sl. No. Item Description
1SUB WORK NO.1 :- Trial Bore
2Item No. 1
3Taking Trial Bore (Core Bore Sampling) by Calyxe machine with TCT/NX bits together undisturbed strata samples for investigation in all types of strata soft soil, murum, hard murum with boulders, soft rock hard rock & quartizite etc. The item includes all Hire & running cost of Callyx Machine conveying all materials to site of work excluding conveyance of callyx, machine and back sampling all over burden strata in glass jar and core samples serially numbered at site in a wooden Core Box, Samples to be taken at 1.0 m interval and conveying to the place as directed by Engineer-in-charge, The diameter of bore in overburden shall be 100 mm and of NX size (50mm) in other strata. The item shall also include M.S. casing pipe of 2.5 mm thick plate in overburdern only and shall be 1.0 m above GL with cap over it.
4In Overburden (Soft soil, murum)
5In Weathered rock with boulders
6In Weathered rock / Soft rock
7In Hard rock quartzite
8TOTALAMOUNT OF SUB WORK NO. 1 :- Trial Bore
9SUB WORK NO.2 :- Supply Well 6.0 Mtr Dia,18.0 Mtr Deep)
10Item No. 1
11Excavation in general in Soft material comprising ofsoft soil ,hard murum with boulders etc as required in wet or dry condition for head worksincluding removing the excavated material upto a distance of 50m beyond area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling etc complete.
12Lift0.00to 1.50 m
13Lift1.50to 3.00 m
14Lift3.00to 4.50 m
15In the Submergence of Dam
16Item No. 2
17Excavation in general in hard material comprising of soft rock, hard rock, Manjara rock etc by blasting / controlled blasting, chiselling as required in wet or dry condition for Head works i.e. Intake well connecting pipe, Jack well, Pump House, supply well etc. for lift 0 to 1.5 and lead of 150 m including baricating, quarding, disposing off surplus excavated stuff within a radius of 0.5 km. as directed by Engineer-in-charge excluding refilling.
18In the Submergence of Dam
19Lift4.50to 6.00 M.
20Lift6.00to 7.50 M.
21Lift7.50to 9.00 M.
22Lift9.00to 10.50 M.
23Lift 10.50 to 12.00 M.
24Lift 12.00 to 13.50 M.
25Lift 13.50 to 15.00 M.
26Lift 15.00 to 16.50 M.
27Lift 16.50 to 18.00 M.
28Item No.3
29Providing and laying in situ 1:2:4 (M-150) grade of C.C. of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including dewatering from work, compacting and curing, finishing etc. complete with initial lift of 1.50m below / above ground level.
30P.C.C M150 For Foundation
31Item No.4
32Providing and laying in situ Cement concrete of trap/granite/quartzite/ gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc, complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L & T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.)
33Footing in M300
34Lift 5.00 to 10.00
35Item No.5
36Providing and casting in situ C.C. of trap/ granite/ quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, from work, compaction, finishing the formed surface with CM 1:3 of sufficient minimum thickness to necessary or roughening if special finish is tobe provided and curing etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use for L&T, ACC, Ambuja, Birla Gold, Manikgad, Rajashree etc. cement is permitted excluding M.S. or Tor reinforcement)For RCC M-300 grade slabs / Landings / Vertical Walls/ Waist Slabs / Steps for Staircase.
37Walling ( Lift 0.00 to 5.00 m.)
38Walling ( Lift 5.00 to 10.00 m.)
39Beam(Lift 0.00 to 5.00 m.)
40Item No.6
41Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15cm layers with all leads and lifts including consolidation, surcharging etc. complete.
42Item No.7
43Dewatering the excavated trenches and pools of water in the building trenches / pipeline trenches, well works by using pumps and other devices including disposing of water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour, fuel ) etc. complete.
44Item No.8
45Providing and fixing in position steel bar reinforcement of various diameter for RCC pipes, caps, foootings, foundation, slabs, beams, columns, canopies, staircase, newels, chajjas, lintels, pardies, copings, fins, arches, etc as per detailed designs, drawing and schedules including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required etc. complete. ( including cost of binding wire ) Tor steel.
46Lift 0.00 to 5.00
47Lift 5.00 to 10.00
48Item No. 9
49Providing and filling around the well boulders filling of selected variety and size of boulders including cost of all materials, labour, transportation, etc. complete with all leads and lifts.
50Item No. 10
51Providing and filling in sand boxing in pipeline or for foundation with sand of approved quality including watering compaction, etc. complete.
52Item No. 11
53Providing structural steel work in single stanchions composed of RSJ, channel etc with caps, bases, mild steel plates, angles, brackets cleats, gusset plates, anchor bolts, etc as per detaild design and drawing or as directed by Engineer-in-charge including cutting, fabrication, hoisting, erecting, fixing in position, making riveted/ bolted/ wided connections and one coats of anticorrosive paint and over it two coats of oil painting etc complete.
54Item No. 12
55Providing and fixing in position M.S. ladder 0.50 M wide consisting of 75 x 10 mm M.S. flats as stringers and 16 mm dia M.S. bars in double rows as steps placed at 25 cm c/c including cost of material and labour involved, welding, anchoring and applying 3 coat of anti-corrosive paint, etc. complete as directed by Engineer-in-charge.
56Item No. 13
57Providing, and fixing 80 mm dia A.C./P.V.C. pipe weep holes at 1.5 M c/c staggered including cost of all materials and labour involved with all leads and lifts.etc. complete with all leads and lifts.
58Item No. 14
59Providing and fixing M.S. chaquerred plate flooring of following thickness supported on M.S.angles (25 x 25 x 5 mm size) including welding, cutting and fabricating the plate to the required square or rounding shape, making holes in the plate, including providing and applying 3 coats of anticorrosive paint, etc. complete as directed by Engineer-in-charge.
608 mm thick
61Item No. 15
62Carrying out recuparation / Yield test for ascertaining the discharge of constructed well / excavated profile as directed by Engineer - In - Charge. The test carried out by drawing down water from the well / profile below normal / subsoil water level upto full depth rise is recorded. The normal water level / subsoil water level / subsoil water level in the well / profile as well as strainer / suction level at pump as per design of W.S. Scheme shall be recorded prior to the test including cost of all materials, overload, labours etc. complete as directed.
63Item No. 16
64Providing and fixing in position C.I. Type dapura steps of 22 mm dia. M.S. bar step with proper anchorage, etc. and providing and applying 3 coats of ant-corrosive paint, etc. complete as directed by Engineer-in-charge.
65Item No. 17
66Drilling bore well of 115 mm dia. Including transportation charges of required machinery.
67For Horizontal Bore
68For Vertical Bore
69TOTALAMOUNT OF SUB WORK NO. 2 :- Supply Well 6.0 Mtr Dia,18.0 Mtr Deep)
70SUB WORK NO.3 :- Pumping Machinery 7.50 Bhp,45 Mtr Head, 10566 LPH Discharge
71Item No.1
72Providing, errecting and giving test of submersible Pump set confirming to I.S. 8034 and motor confirming to I.S. 9283 with water proof wiring, pump shall be suitable for 64m delivery head and discharge of 4.90 LPS with stainless steel shaft, motor suitable for working 415V(+/-) 10%, 3 Phase, 50 Hz AC supply with cable guard, thrust carbon bearing to withstand entire hydraulic thrust. The pump shall be suitable for direct coupling with suitable suction, straining pump should have suitable discharge outlet as per manufacturers design. Stream lined non return valve shall be provided with pump, 3m submersible copper conductor cable and 2 pair of erection clamps, 65mm width, 150mm Dia thick shall be provided with each pump.
737.50 HP Submerssible Pumpset
7410566 LPH Discharge
7545.00 Head in M. 150 MM Dia.
76Item No.2
77Providing ISI mark G.I. pipe of following class and dia.excluding GST levied by GOI and GOM in all respect including inspection charges, transportation to stores, etc. complete as per IS-1239/2004.
78100 mm Dia. G.I. Pipe ( Heavy )
79Item No.3
80Lowering, laying and jointing G. I. pipes and specialsof following class and diameter including conveyance from stores to site of works, all labour, etc. complete either underground or in vertical position, as directedby Engineer-in-charge.
81100 mm Dia. G.I. Pipe ( Heavy )
82Item No.4
83Providing and Fixing ISI mark CI D/F reflux valves (non-return valves ) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete.Reflux valves as per I.S.5312 Part I (1984)
84100 mm dia Non return valve PN -1.60
85Item No. 5
86Providing & fixing double flange sluice valve confirming for IS-14846 including worn gear arrangements as per test pressure,stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete.
87100 mm dia sluicevalve PN -1.60
88Item No. 6
89Providing & fabricating of suitable size base frame for submerssible pump sets.
90Item No. 7
91Supplying errecting G.I. pipes A grade errected for enclosing armoured cable 25 mm diafor underground and above ground cable with etc. complete to cover the cable all over.
9225 MM Dia G.I.Pipe
93Item No.8
94Making trench in soft soil of suitable width & depth for laying provided L.T cable up to 10 sq.mm complete.As per specification No. CW-EXN-CTR
95Item No.9
96Providing and fixing L.T. Panel comprising of ameter, voltmeter switches capacitor, water level guard etc.
977.50 HP Pump
98Item No.10
99Providing & fixing electric cable ( flat ) 10 mm² for submerssible pump complete.
1003 Core 10 Sqmm
101Item No. 11
102Providing and supplying ISI standard CI flanged / S& S specials excluding GST levied by GOI & GOM in all respect including railway freight, insurance, unloading from railway wagon, loading into truck transport to departmental store, unloading stacking etc. complete.
103Item No. 12
104EARTHINGSupplying & errecting galvanised cast iron earth plate size 60 x 60 x .6 cm complete with all materials , testing as per specification No.EA-EP
105Item No. 13
106Providing & making flanged joints to flanged C.I pipes of all classes/specials etc including cost of all jointing materials ( rubber packing,nut bolts etc),labour,hydraulic testing etc complete.
10780 mm dia
108Item No. 14
109Providing & fixing 100 mm dia. Pressure gauge.
110TOTALAMOUNT OF SUB WORK NO. 3 :- Pumping Machinery 7.50 Bhp,45 Mtr Head, 10566 LPH Discharge
111SUB WORK NO.4 :- RCC Switch Room 2.50 x2.50 x 3.0 Mtr
112Item No.1
113Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.
114Item No.2
115Excavation for foundation / pipe trenches in hard murum with boulders, WBM roads including removing the excavated material upto a distance of 50 meters beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding back filling etc. complete.
116Item No.3
117Providing and laying in situ 1:3:6 (M-100) grade of C.C. of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including dewatering from work, compacting and curing, finishing etc. complete with initial lift of 1.50m below / above ground level.
118Item No.4
119Providing and laying in situ Cement concrete of trap/granite/quartzite/ gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering, form work, compaction, finishing and curing, etc, complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L & T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.)
120Footing M 200
121Item No.5
122Providing and casting in situ C.C. of trap/ granite/ quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, from work, compaction, finishing the formed surface with CM 1:3 of sufficient minimum thickness to necessary or roughening if special finish is tobe provided and curing etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use for L&T, ACC, Ambuja, Birla Gold, Manikgad, Rajashree etc. cement is permitted excluding M.S. or Tor reinforcement)For RCC M-200 grade slabs / Landings / Vertical Walls/ Waist Slabs / Steps for Staircase.
1231) Columnin M200
1242) Beam & Lintelin M200
1253) Chajjain M200
1264) Slabin M200
127Item No.6
128Providing and fixing in position steel bar reinforcement of various diameter for RCC pipes, caps, foootings, foundation, slabs, beams, columns, canopies, staircase, newels, chajjas, lintels, pardies, copings, fins, arches, etc as per detailed designs, drawing and schedules including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required etc. complete. ( including cost of binding wire ) Tor steel.
129Item No. 7
130Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete.
131Item No. 8
132Providing dry trap / granite / quartzite / gneiss, rubble stone soling in 15cm to 20 cm thick layers (including hand packing and compacting), etc. complete.
133Item No. 9
134Filling in plinth and floors / trenches with contractor’s murum for bedding in 15cm to 20cm layers including watering and compaction complete.
135Item No. 10
136Providing internal & external electrification of switch room including cost of all material & labour shown in rate analysis etc. complete.
137Item No.11
138Providing 2nd Class B.B masonary with conventional bricks in CM as below in super structureinner walls / external walls including normal dewatering, striking joints on unexposed faces, raking out joints on exposed faces and watering etc complete in Cement Mortor (1:6)
139In Foundation & plinth
140In Super Structure
141Item No. 12
142Providing and fixing steel window of various sizes as per detailed drawing without hot dip zinc coating, without ventilators, including fabricating / glazing with plain / obscured glass panels of approved type and quality, iron oxidised fixtures and fastenings, finishing with oil painting two coats complete (with guard bars 12 mm square at 10 cm c/c.)
143Item No. 13
144Providing and fixing steel frame door of angle 50x50x6 mm with mild steel bars 16mmdia. horizontally at 10mm c/c for ventilator portion including iron hold fast boxes for fixings hutters including welding, finishing, painting etc. complete complete.
145Item No. 14
146Providing internal cement plaster 12mm thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete.
14712 mm thick ( Without neeru finish)
148Item No. 15
149Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete.
150Neeru finish
151Item No. 16
152Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.
153Sand faced plaster
154Item No. 17
155Providing and applying three coats of water proof cement paint of approved manufacture and of approved colour tonew plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc. complete.
156Item No. 18
157Providing and applying primer coat for wall surface to receive oil bound distemper treatment etc. complete.
158Item No. 19
159Providing & applying washable oil-bound distemper of approved colour and shade to old & new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete.
160Item No. 20
161Providing & laying rough Shahabad Stone flooring 40mm to 50 mm thick & of required width in plain/diamond pattern on a bed of 1:6 C.M including cement float,striking joints,pointing in cement morter 1:3 curing & cleaning etc. complete ( Bd-M-1/379)
162TOTALAMOUNT OF SUB WORK NO. 4 :- RCC Switch Room 2.50 x2.50 x 3.0 Mtr
163SUB WORK NO.5 :-Rising Main110 mm dia HDPE 6 kg/cm2 L -2360 Mtr
164Item No.1
165Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 /14151 /12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint /compression fitting joint or flanged joint excluding coupler/ specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete.As per IS:4984-2016
166110 mm dia HDPE 6 Kg/cm2 pipe
167Item No. 2
168Providing ISI mark C.I. pipe of following class and dia.excluding GST levied by GOI and GOM in all respect including inspection charges, transportation to stores, etc. completeas per IS-1239/2004.
169100 mm dia C.IClass pipe
170Item No. 3
171Providing & supplying PVC/C.I / GI specials ( 5 % of cost of pipe shall be considered percent of specials for estimate purpose.)
172Item No. 4
173Providing double flange sluice valve confirming for IS-14846 including worn gear arrangements as per test pressure,stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete.
174As Scoure Valve
17580 mm dia. Sluice Valve PN 1.6
176As Isolation Valve
177100 mm dia. Sluice Valve PN 1.6
178Item No. 5
179Providing and supplying Air Valves as per IS-14845-2000 and MJP’s standard specifications of approved make and quality of following diameters including railway freight, inspection charges, unloading from railway wagons, loading into truck, transportation upto departmental stores, unloding and stacking excluding GST levied by GOI & GOM in all respect etc. complete.
18050 mm dia. Double Ball Air Valve
181Item No.6
182Excavation for foundation / Pipe Trenches in Earth Soil Of All Types, Sand, Gravel,Soft Murum,Hard Murum With Boulders, WBM Roads,Soft Rock.Old Cement,Lime Masonry Foundation And Hard Rock By Controlled Blasting, including removing the excavated material upto a distance of 50mtrs. And lift as below stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding back filling etc. complete.(Average Rate)
183Item No.11
184Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation 15 cm to 20cm layers including watering and compaction complete.
185Item No.12
186Lowering, Laying and Jointing H. D. P. E./M. D.P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complet with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II
187110 mm dia HDPE 6 Kg/cm2 pipe
188Item No. 13
189Lowering, laying and jointing C. I. pipes and specials of following class and diameter including conveyance from stores to site of works, all labour, giving satisfactory hydraulic test, etc. complete either underground or in vertical position, as directed by Engineer-in-charge.
190100 mm dia C.I Class pipe
191Item No. 14
192Hydraulic testing of H. D. P. E./ M. D. P. E. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments,labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position..
193140 mm dia HDPE 6 Kg/cm2 pipe
194Item No. 15
195Hydraulic testing of C.I.pipeline to specified pressure including cost of all materials and labour and water for testing for the length upto 1km., using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rates under this item shall also include cost of retesting.
196100 mm dia C.IClass pipe
197Item No. 16
198Lowering, laying and jointing Valves and specials of following class and diameter including conveyance from stores to site of works, all labour, giving satisfactory hydraulic test etc complete either underground or in vertical position as directed by Engineer-in-charge
199As Scoure Valve
20080 mm dia. Sluice Valve
201As Isolation Valve
202100 mm dia. Sluice Valve
203Item No. 17
204Providing and laying in situ 1:2:4 (M-150) grade of C.C. of trap / granite/ quartzite/ gneiss metal for foundation and bedding including dewatering, form work, compacting and curing finishing etc complete with initial lift of 1.50m below /above ground level.
205Item No. 18
206Providing and fixing in position air valve shaft including providingand fixing GI Medium class or 6mm thick M.S, PIPE shaft 2.70m long over branch flange of air valve tee providing PCCblock of M- 150concrete 150mm thick around the air valve tee including encasing of vertical shaft in PCC M-150 as shown in type design together with providing and making flanged ionts wherver required and fixing of air valve over the shaft excluding cost of air vavle and branch flanged air valve tee, etc. complete as per type desihn and as per directed by Engineer - in -charge for following diameters of pipe line
207Foundation on Murum and Harder Strata.
208150 mm
209Item No. 19
210Providing and fixing in position M.S. Air valve boxes fabricated with 2 mm thick M.S. plate, 30 x 30 x3 mm size M.S. angle frame, concre- ting in M-150 for fixing the box in position,applying two coats of oil paint, painting chainage, locking arrangement, etc. complete as directed by Engineer-in-charge.
21150 mm dia. Double Ball Air Valve
212Item No. 20
213Providing & costructing B.B masonry valve chamber with 15 cm thick 1: 3 :6 proportion PCC bedding ,excluding excavation ,B.B masonry in C.M 1:5 proportion precast RCC frame and cover etc. complete as directed by Engineer-in-charge
214Chamber size 60X45X120 cm
215(Rs.5816.00+Rs.1265.00=Rs.7081.00)
216Item No.21
217Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard murum material in 15cm layers with all leads and lifts including consolidation, surcharging etc. complete.
218TOTALAMOUNT OF SUB WORK NO. 5 :- Rising Main110 mm dia HDPE 6 kg/cm2 L -2360 Mtr
219SUB WORK NO.6 :-R.C.C. E.S.R25000 lit. Capacity , 12 Mtr ST.HT
220Item No. 1 :-Designing (aesthetically) and constructing RCC elevated service reservoirs of following capacity with RCC staging consisting of columns, internal and external bracings spaced vertically not more than 4.5M. Centre to centre for ESR having capacity upto 500cum and not more than 6 m. c/c for ESRs having capacity above 500 cum including excavation in all types of strata, foundation concrete, cement plaster with water proofing compound to the inside face of the container including refilling disposing of the surplus stuff within a lead of 50 M. all labour and material charges including lowering, laying, erecting,, hoisting and jointing of pipe assembly of inlet, outlet, washout, overflow and bypass arrangements as per departmental desing, providing and fixing accessories such as M.S. ladder, C.I. manhole frame and covers water level indicatiors, lightening conductor, G.I. pipe railing around walk
221way and top slab, providing spiral stairecase from ground level to roof level & stainless steel ladder in container, MS grill gate of 2 M. height with locking arrangement of approved design BB masonary chambers for all valves, ventilating shafts, providing and applying three coats of Acrylic emulsion with silicon additives paint to the structure including roof slab epoxy painting to internal surface & antitermite treatment for underground parts of the structure and giving satisfactory water tightness test as per IS code the job to include painting the name of the scheme and other details on the reservoir as per the directions of Engineer-in-charge
222Note :-
2231) The design of the structure shall be in accordance with relevant (IS 456-1987,IS 875-1987, IS 3370 - 1965or revised)
2242) The design shall satisfy the stipulations as per IS 1983- 1984 and IS 13920 / 1993 for seismic force and IS 11682/1985 for RCC staging of overhead tanks.
2253)For design having more than 6 columns, provision of internal bracing is obligatory. External bracing is also obligatary.
2264) The entire structure shall be in M-250 mix only.However concrete in contact with water such as container , base slab , wall ,roof slab & footing in water born area shall be in M-300.
2275) Plain round mild steel bars grade I confirming to IS 432 part -I or high yield strength deformed bars confirming to IS 1786 or IS 1139 shall be used, grade II mild steel bars will not be allowed
2286) Irrespective of the type of foundation proposed in the design one set of bracing be provided at the ground level.
2297) These rates include providing M.S.ladder for ESR\"s upto 2 lakh liters capacity and providing spiral staircase for ESR above 2 lakh lit. capacity.
2308) Staging height will have to be designed with stresses of M-200 concrete.However all RCC construction should be done in m 250 except concrete in contact with water shall be designed & constructed in M300.
2319) These rates are including the cost of uplift pressure if any and entire dewatering during execution.In case of water logging area where water is struch at shallow depth extra provision of dewatering shall be made as per site condition.
23210) All conditions given in the Member Secretary\"s Circular No.MJP/TS-1/350/1668 Dt.2.8.97 and MJP/S-1/350/2127 Dt.13.7.99 shall be strictly followed and additional cost if any, due to these conditions is included in the rates mentioned below.
23311) 75% part rate shall be payable for reinforcement cocrete and plastering items of containers of ESR till satisfactory hydraulic testing for water tightness in given and till that work shall be treated as incomplete.
23412) The rates as indicated in the table are excluding the cost of pipes, specials, valves required for inlet, outlet, washout, overflow and bypass arrangements. The scope of the pipe assembly work shall be upto 5 M. beyond outside face of the outremost column.
23513) For ESR upto 500 cum capacity CIDF pipes upto 300 mm dia shall be provided and specials should be used. For ESR above 500 cum, M.S. pipes and M.S. specials (minimum 8mm thick uo to 500mm dia. & 10 mm thickness above 500 mm dia.) shall be used with proper anticorrosive epoxy treatment from inside and outside
23614) Below mentioned rates are for foundations with individual footing with bearing capacity of 20 tonnes per sqm. For raft foundations, these rates shall be increased by 7.5% where safe bearing capacity (SBC) is 5 MT per sqm and by 5% where SBC is more than 5 MT / sqm and upto 10 MT/sqm. This % of 5% or 7.5% is applicable for estimation of amount of LS item of ESR. For Extra Item due to change from individual foundation to raft actual increase in concrete and steel be paid as per relevent DSR Item.
23715) The rates shall be increased by 30 % for bearing piles upto depth of 10 m and for further increaseed in depth by 5 m each it shall be increased by another 10 5 .These rates are applicable where raft is not feasible for pile foundation sufate resistant cement shall only be used.Single pile for the column is not permitted Group of piles shall be designed with pile cap for each column of ESR.
23816) Theserates are applicable for staging height of 12 m .These rates shall be increased or decreased for per meter variation in the staging height as below. 12 to 16 M staging 2% per m16 to 20 M staging3% per m 20 M and above4% per m
23917) Following rates are for seismic zone-III , for Seismic zone-IVthese rates shall be increased by 5%, and for Seismic zone-II these rates shall be decreased by 5%
240RCC ESR 25000 lit. capacity & staging height 12 M.
241Item No. 2 :-Providing & supplying of ISI CI double flanged pipes including all taxes, insurance, railway freight, unloading from railway wagon, loading into truck transport to departmental store, unloading stacking etc complete
242100 mm dia CIDF pipes
243Item No. 3 :-Providing & supplying ISI mark CIDF Sluice Valves and butterfly valves of following diameter including all taxes (Central & Local) railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental store, unloading, stacking etc complete
244100 mm dia CIDF Sluice Valve PN 1.0
245Item No. 4 :-Providing C.I. / M.S. specials required for above pipes including all taxes transport etc complete
246Diameter 80 mm to 300 mm
247TOTALAMOUNT OF SUB WORK NO. 6 :- R.C.C. E.S.R25000 lit. Capacity , 12 Mtr ST.HT
248SUB WORK NO.7 :-Distribution system 110 to 75 mm dia PVC 4 kg/ cm2 Length-4900 Rmt
249Item No. 1
250Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as per IS specification no. 4985 / 1988 including all local and central taxes, transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores / site and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvemt cement, etc. complete (selffit type to be jointed with cement solvent).
251110 mm dia 4kg/sq.cm
25275 mm dia 4kg/sq.cm
253Item No. 2
254Providing and supplying ISI mark G.I pipes of following class and dia meter including all taxes (Central & loca) insurance, railway freight, unloading from railway wagon, loading into trucks, transport to departmental stores / site, unloading, staking etc complete
255100 mm dia (H)
256Item No. 3
257Providing, erecting connecting double flanged short body pattern type manually operated Butterfly Valve haivng body, disc and end cover in graded cast iron to IS 210 Gr. CF 200 generally confirming in BS 5155, Synthetic rubber faced ring secured on disc by retaining ring with stainless steel screw stub shaft of stainless steel riding in teflon bearing excluding C.C. foundation /structural steel support confirming to IS 13095-1991 Sluice valves - PN - 1
258100 mm dia CIDF Sluice Valve
25980 mm dia CIDF Sluice Valve
260Item No. 4
261Providing and supplying PVC/C.I / G.I. Specials as directed by Engineer in charge etc complete
262Item No. 5
263Excavation for foundation / Pipe Trenches in Earth Soil Of All Types, Sand, Gravel,Soft Murum,Hard Murum With Boulders, WBM Roads,Soft Rock.Old Cement,Lime Masonry Foundation And Hard Rock By Controlled Blasting, including removing the excavated material upto a distance of 50mtrs. And lift as below stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding back filling etc. complete.(Average Rate)
264Item No. 6
265Lowering laying and jointing with P.V.C. pipes and spcials of Class and 90mm diameter including cost of conveyance from stores to site of work including cost of all labour, material except cement solvent, rubber ring, giving satisfactory hydraulic testing as per IS code, etc. complete. (with cement solvent joint / ring fit joint), Working Pressure 4 Kg./Sqm
266110 mm dia 4kg/sq.cm
26775 mm dia 4kg/sq.cm
268Item No. 7
269Lowering ,laying and jointing G.I Pipes and specials of following class and dia including conveyance from store to site of works ,all labour etc complete.
270100 mm dia (H)
271Item No. 08
272Lowering, laying and jointing Valves and specials of following class and diameter including conveyance from stores to site of works, all labour, giving satisfactory hydraulic test etc complete either underground or in vertical position as directed by Engineer-in-charge
273100 mm dia CIDF Sluice Valve
27480 mm dia CIDF Sluice Valve
275Item No. 09
276Providing and fixing C.I. Road box including loading unloading and carting to site of work including all necessary excavattion in all types of strata and fixingin murum packing etc. complete.
277225 x 300(40 kg)
278100 x225(20 kg)
279Item No. 10
280Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation 15cm to 20cm layers including watering and compaction complete.
281Item No.11
282Hydraulic testing of PVC pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting , placing end cap making arrangement for filling safe water etc complete.
283110 mm dia 4kg/sq.cm
28475 mm dia 4kg/sq.cm
285Item No.12
286Hydraulic testing of G.I pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting , placing end cap making arrangement for filling safe water etc complete.
287100 mm dia (H)
288Item No.13
289Refilling the trenches with available excavated stuff with soft material first over pipelines and then hard material in 15cm layers with all leads and lifts including consolidation surcharging etc complete.
290Item No. 14
291Providing and laying in situ 1:2:4 (M-150) grade of C.C. of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including dewatering from work, compacting and curing, finishing etc. complete with initial lift of 1.50m below / above ground level.
292TOTALAMOUNT OF SUB WORK NO. 7 :- Distribution system 110 to 75 mm dia PVC 4 kg/ cm2 Length-4900 Rmt
293SUB WORK NO.8 :-Trial & Run For Scheme
294Item No. 1 :- Trial And Run
295Commisioning running and maintaining the scheme to quantites, rated capacity, including manning necessary personnel such as operator, valveman, etc. as per requirements of the scheme and who should also administerchemical dose for a period of 1 month for individual scheme and 3 months for regional scheme, together with training of personnel spared by MJP/ Local Body and handing over the scheme to Local Body after completion of the above period as directed by Engineer-inchargea) For single village Without WTP
296Note:Required chemicals to be supplied byDepartment free of cost and electricity bill willalso be paid by the Depertmen
297a) For single village Without WTP
298TOTALAMOUNT OF SUB WORK NO. 8 :- Trial & Run For Scheme
299SUB WORK NO.9 :-Miscellaneous works
300Item No. 1
301Providing and erecting chain link fencing 1.6 M. height with G.I. chain link of size 50 x 50 mm 8 guage thick and fixed 75 mm above Ground levelon vertical M.S Angle of 40 x 40 x 6 mm size including excavating pits for foundationand embedded in C.C. block of 1:4:8 mix of size 450 x 450 x 670 mm. at 1.75 M.c/c with iron bar 16 mm dia as hold fast including welding link with angle frame at 30 cm c/c withnuts and bolts and horizontal M.S. Angles at top and bottom of 25 x 25 x 5 mm size and vertical M.S. flat 35 x 5 mm and 25 x 5 mm horizontal including cross support of 40 x 40 x 6 mm Angles both sides at every corner or bends embedded in concrete blocks of 1:4:8 of size 450 x 450 x 670 mm including 3 coats of oil painting etc. complete.
302Item No.2
303Providing and fixing M.S. gate 2.5 M wide for compound with 40 mm dia M.S.black pipe medium class, approved grill work, RCC M - 150 side pillars of 25 cm x 40 cm x 2.5 M height, its foundation, finishing, painting etc. complete.

AI Tender Summary

OUR REF NO 34704132
AUTHORITY Government Departments
TENDER VALUE 1.14 Crore
LAST DATE 12-11-2022
Authority
Authority Name Rural Development Department
Work Description Tender For Sarangpur Village Water Supply Scheme , Tq.Mehkar Dist.Buldana
Basic Detail
Tender No E-TENDER NOTICE NO.238 /2022-23 3 RD CALL
Bidding Type Tender
Location
City sarangpur
State Maharashtra
Key Dates
Publish Date 07 Nov 2022
Submission Date 12 Nov 2022
Open Date 14 Nov 2022
Finance
Tender Value 1.14 Crore
Tender Fee 5600
EMD 1.15 Lakhs
Exemption Not Available
Document List
2a3fb1fa-c49c-46fe-b063-8077ba9fd7ba.html
BOQ_1472075.xls
NIT3.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 07, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 12, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Nov 14, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

2a3fb1fa-c49c-46fe-b063-8077ba9fd7ba.html

xls

BOQ_1472075.xls

pdf

NIT3.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders