Public Works Department-PWD has published Tender For Providing Functional Household Tap Connection (Fhtc) At Amini. Submission Date for this Tender is 23-11-2022. Water Pipe Line Tenders in amini Lakshadweep. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 09-Nov-2022 | Additional Conditions and Make List | Terms and Conditions | 23-11-2022 |
Sl. No. | Item Description |
1 | 125mm Dia HDPE WORKS (Main Transmission Line) |
2 | Supplying, laying and jointing 125 mm Dia (PE-80 PN-10 ) HDPE pipes of specified grade and conforming to IS 4984-1995 with latest amendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation, testing and commissioning. The rate is inclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bends, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. |
3 | Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of various dia. with body, bonnet of ductile iron (DI) conforming to IS-1865 and of grade GGG50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacuum tight and 100% lead proof with face dimensions as per BS 5163-89 / IS 14846-2000 / DN 3202 F4/F5. The stem sealing should be with toroldal sealing rings (minimum 2 “O” rings). Body and bonut should be coated with Electrostatically applied Epoxy Power Coating with minimum coating thickness of 250 micron both inside and out side. The rate is inclusive of cost of valve, T.P set, bolts & nuts and rubber insertions etc. but excluding earth work. For Sluice Valve of PN - 1.6 and 150 mm |
4 | 110mm Dia HDPE WORKS (Distribution Line) |
5 | Supplying, laying and jointing 110 mm Dia (PE-80 PN-10 ) HDPE pipes of specified grade and conforming to IS 4984-1995 with latest amendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation, testing and commissioning. The rate is inclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bends, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. |
6 | Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of various dia. with body, bonnet of ductile iron (DI) conforming to IS-1865 and of grade GGG50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacuum tight and 100% lead proof with face dimensions as per BS 5163-89 / IS 14846-2000 / DN 3202 F4/F5. The stem sealing should be with toroldal sealing rings (minimum 2 “O” rings). Body and bonut should be coated with Electrostatically applied Epoxy Power Coating with minimum coating thickness of 250 micron both inside and out side. The rate is inclusive of cost of valve, T.P set, bolts & nuts and rubber insertions etc. but excluding earth work. For Sluice Valve of PN - 1.6 and 100 mm |
7 | Supplying, laying and jointing 63 mm Dia (PE-80 PN-12.5 ) MDPE pipes of specified grade and conforming to IS 4984-1995 with latest amendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation, testing and commissioning. The rate is inclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bends, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc |
8 | Supplying, laying and jointing 20 mm Dia (PE-80 PN-16 ) HDPE pipes of specified grade and conforming to IS 4984-1995 with latest amendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation, testing and commissioning. The rate is inclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bends, reducers etc. complete. (Contractor will make his own arrangements for procuring water for testing) etc. |
9 | House Service Connections |
10 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (External work) 15 mm nominal outer dia .Pipes. |
11 | Providing and fixing PTMT bib cock of approved quality and colour. 15mm nominal bore, 86 mm long, weighing not lessthan 88 gms |
12 | Domestic Water meter |
13 | Providing, installing and giving satisfactory field testing of domestic water meter of 15 mm dia, horizontal inferential single or multi jet type with magnetic drive and dry dial suitable for ambient 50 degree C temperature duely sealed against tampering complete with couplings at both ends and conforming to class B as per IS 779/1994 (6th revision) with ISI mark along with manufacturers test certificate and guarantee certificate including cost of all materials and labour with EEC mark and Providing & fixing Surface Boxincluding necessary excavation, fixing & refiling etc. complete |
14 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete: 15 mm nominal bore |
15 | OTHER COMMON WORKS |
16 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
17 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including re- alingment of water supply pipe line like PVC HDPE, Electrical cable, Telephone cables etc. whereever necessary, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil : |
18 | Pipes, cables etc. not exceeding 80 mm dia. |
19 | Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
20 | Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete. |