| 1 | Dismantling existingstreet light fittings high mast light, of any wattage / capacity, LED lights, flood light, metal halide fitting etc. fixed on pole/wall to find out defect/ taking out unserviceable parts and repairing by changing the defective part(s) including minor repair to cable connection / loose connection / necessary cleaning the bowl/perpex cover etc and refixing the same after testing complete all as specified and as directed by Engineer-in-charge.Note :- (i)Parts such as LED driver shall be measured and paid separately under appropriate item of this BOQ as supply only.(ii) The T & P, ladderand vehicles etc. will be arranged by the contractor and the cost deemed to be included in the quoted rates. |
| 2 | Supply and fixing in replacement Integral LED street light luminaire white light comprising of epoxy powder coatedhousing, enclosed with glass cover in frame, 45 W not less than 100 lumens per watt AC 230 Volt supply (white Glass suitable for 40/50 mm OD entry for direct mounting on pipe bracket with all electrical accessorieswired up to the terminal block suitable for mounted on bracket / poles / walls complete all as specified and directed by the Engr-in-Charge. |
| 3 | Supply and fixing in replacement Integral LED street light luminaire white light comprising of epoxy powder coatedhousing, enclosed with glass cover in frame 60 W not less than 100 lumens per watt AC 230 Volt supply (white Glass suitable for 40/50 mm OD entry for direct mounting on pipe bracket with all electrical accessorieswired up to the terminal block suitable for mounted on bracket / poles / walls complete all as specified and directed by the Engr-in-Charge. |
| 4 | Supply & fix flood light fitting powder coated pressure die cast aluminium housing with mirror optic reflector toughened glass cover with high power LED, 120 watt 240 volt 50 Hz and unique peanut lens with optics for uniform distribution with SMPS complete with drivers and LED, connectors prewired complete allas directed by engr in charge. |
| 5 | M&L for LED post top 40 watt made in cast aluminium spigot housing with decorative clear opal acrylic diffuser and IP 65 protection complete including fixing arrangement complete all as specified and as directed. |
| 6 | M&L for LED 9 watt Bollard integral decorative LED Bollard with Opal acrylic and IP 65 protection complete including fixing arrangement complete all as specified and as directed. |
| 7 | Supply and fixing in replacement of 1100 volts grade heavy duty twin core cable PVC insulated sheathed aluminium stranded conductorof size 2.5 Sqmm for connection purpose complete all as specified and directed by the Engr-in-Charge. |
| 8 | S&F in repair time switch, single phase 5KW load with contactor, incoming MCB & outcoming MCB rating of 25-40 Amps & main load circuit wiring (copper) of min 10 sqmm with enclosure and circuit sheet complete all as specified and as directed. |
| 9 | S&F in repair power Contactor 40 Amp single phase 415 Volt having AC coil Complete all as specified and as directed. |
| 10 | Supply and fixing in replacement brackets made out of GI tubing light grade 40mm dia, 1.5 metre long bent to shape at 120 degree angle at half metre from bottom (as per sample), fixing on poles/walls for street light fitting including before fixing applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-charge. Note :- Clamps and nut bolts for fixing as required shall be measured and paid separately under appropriate item. |
| 11 | Excavation in trenches not exc 1.5 m wide and n. exc 1.5 m deep in soft/loose soil for foundation/ cable etc n exc 10 Sqm on plan and n exc 1.5 Sqm in depth all as specified and directed by Engr-in-Charge |
| 12 | Returning, filling in including spreading levelling, watering and well ramming in layer n. exc 25 cm thick complete all as specified and directed |
| 13 | Removing surplus soil to a distance n. exc 50 m and depositing where directed at level n. exc 1.5 m above the starting point complete all as specified and directed |
| 14 | M&L sand cushioning, with dry and clean fine locally available sand for underground cable 8 cm before laying cable and 15cm after laying and punned to 18cm after laying of cable complete all as specified and directed by Engineer-in-Charge.Note : Punned thickness shall be considered for payment purpose. |
| 15 | Supply and laying best quality locally availble Sub class \"B\" bricks(old size) for cable protection cover, laid flat and lay in trenches over the cable complete all as specified and directed. |
| 16 | Labour only for one layer of bricks sub class \"B\" bricks (old brick reused obtained from item taking out cable here-in-after) for cable protection cover laid flat and layy in trenches over the cable, prependicular to the direction of cable complete all as directed. |
| 17 | Material and labour for taking down the exisitng unserviceable LT cable of any size/make as specified and directed by Engr in Charge. Note : (i) Earth work shall be measured and paid separatley under relevant items. |
| 18 | Supply and lay, jointing and testing in trenches on poles walls XLPE insulated armoured heavy duty electric cable with alluminium counductor 1100 volt grade all as specified and directedof cross sectional10 sqmm x 2 core complete all as specified and directed |
| 19 | Supply and lay, jointing and testing of LT cable 1100 Volt grade 25 Sqmm 3.5 core with stranded aluminium conductor PVC sheathed armoured confirming to IS1556 laid in trenches/along poles/through pipe/through duct complete all as specified and directed |
| 20 | Supply and fixing in replacement LT cable junction box, dust and water proof (IP65), out door type, made out of Polycarbonate with glass fiber re-inforced, size of box 200 x 160 x 98 mm with swiveling cover and locking clamp, pole mounting, consisting of aluminium bus bar strip 150mmx 20mm x 3mm, 4 Nos mounted on PVC insulator andprovision of incoming/outgoing cables with grommets, including in built 6Amp MCB, SP, 9/10KAone No complete all as specified and as directed by Engineer-in-charge. Note : Rate deemed to be inclusive of MS clamps and nut bolts for fixing the box along pole and. |
| 21 | M&L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9 metres long) incliuding painting of poles with two coats of synthetic enamel paint over a coat of primer in alternate strip of 30 cm each in black and white colour upto 1.5 mtr height from top of PCC pedestal/copping of poles and numbering of poles with synthetic enamel paint white in 80mm high letters over 150mmx230mm black base made from synthetic enamel paint and dismentling of old u/s pole and removing from site complete all as specified and as directed. NOTE : Earth work and PCC work shall be measured and paid seperately. |
| 22 | M/L for trimming of branches of trees touching LT electric over head line as one length span n exc 50 mtr comprising of conductor n exc 6 Nos and making clear about 3 mtr in radius and carrying and depositing where directed not exceeding 50 mtr complete all as specified and as directed. |
| 23 | M & L for GI pipe medium grade laid in trenches / fixed to pole / wall for cable protection of following size 40 mm complete all as specified and as directed. |
| 24 | supply only in repair LED driver suitable for 25/45 Watt 230 Volt AC, PF >0.95 Supply LED fitting complete all as specified and as directed. |
| 25 | Supply onlyin repair LED driver suitable for 60 Watt 230 Volt AC, PF>0.95 SupplyLED fitting complete all as specified and as directed. |
| 26 | M&Lfor PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundationfor electric pole etc. complete all as specified and as directed by Engr-in-Charge. |
| 27 | M & L for PCC (1:3:6) type C2 (using 40mm graded stone aggregate) in coping for electric poles or for stay assy etc. complete all as specified and directed . |
| 28 | Earthing complete with galvanised steel earth plate electrode 600mmx600mmx6 mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level connected to GI wire 4 mm dia by means of bolts, nuts, check nuts and washers completeincluding earthing pit, Chemical compound, Earthing leadup to 7.5 m, 20 mm dia medium grade GI watering pipe, G.I. protection pipe 40mm diaeath pit in PCC 1:2:4 type B-1 using 20 mm graded stone agggragate RCC pit cover including earth work complete all as shown electrical palte No-5 of SSR-2009 (Part-I) NOTE:-The unit rate shall include for excavation & earth work in any type of soil/strata, PCC 1:2:4 type B-I for pit & RCC 1:2:4 type B-I for cover with 8mm dia CTD Bar @150mm C/C both way, funnel with watering pipe 20 mm dia medium grade, 15mm dia light grade GI pipe up to 7.5 mtr long, wiremesh complete all as specified and directed. |
| 29 | M&L for PCC pole painting with first quality super enamelled paint and sign letter writing for pole numbers in letters or figure (Block, Roman, Italic or Indian) complete including surface preparation are as specified and directed.Note : Job will consisting 10 letters of 4 cm hight. |
| 30 | M& L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size |
| 31 | Supply and fix PVC rigid conduit pipe for junction box to street light for protection of aluminium wire including suitable clamp and fixing arrangement complete all as specified and directed |
| 32 | Supplying and fixing cross arms, bracings, stiffeners, supports, clamps and back plates fabricated from structural steel sections conforming to Fe-290 (Gde E-165) including nuts, bolts, washers, welding, binding cold or hot, drilling holes for bolts, in any shape or size as indicated or directedcomplete all as specified and directed by Engr-in-Charge. Note : Unexposed surface of steel sections shall be applied onecoat of red oxide primer and exposed surface shall be applied one finishing coat of aluminium over a coat of red oxide primer. cost of the same is included in the unit rate of the item. |
| 33 | Supply & Fixin replacement of MCCB3 Pole, 415 V, Adjustable type, up to 100 Amps with breaking capacity 16 KA all as specified and directed |
| 34 | Supply & Fixin replacement of MCCB 4 Pole, 415 V, Adjustable type, 100 Amps with breaking capacity 25 KA all as specified and directed |
| 35 | Supply & Fixin replacement of MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA all as specified and directed |
| 36 | Supply and fixing SPN 32amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) in the MCB DB complete with connection testing and commissioning complete all as specified and directed |
| 37 | Supply and fixing TPN, 100 Amps, 415V, 10KA\"B\" curve miniature circuit breaker (MCB)in the DB complete with connection testing and commissioning complete all as specified and directed |
| 38 | Supply and lay, jointing and testing of LT cable 1100 Volt grade 50 Sqmm 3.5 core with stranded aluminium conductor PVC sheathed armoured confirming to IS1556 laid in trenches/along poles/through pipe/through duct complete all as specified and directed |
| 39 | M&L for pre-stressed cement concrete pole, 9 metre long cross section 102mmx152mm at top and 102mmx289mm at bottom class 10 complying with requirement of IS-1678-1998 including painting of pols with two coats of synthetic enamel paint over a coat of primer in alternate strip of 30 cm each in black and white colour upto 1.5 mtr height from top of PCC pedestal/copping of poles and numbering of poles with synthetic enamel paint white in 80mm high letters over 150mmx230mm black base from synthetic enamel paint and dismentling of old U/s pole and removing from sitecomplete all as specified and directedNote :Earth work and PCC work shall be measured and paid separately |
| 40 | S&F MS clamps made out of MS flat iron of any size as required for fixing street light fitting and main switches, etc including nut, bolts washer and before fixing apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 41 | Supply and lay, jointing and testing of LT cable 1100 Volt grade 35 Sqmm 3.5 core with stranded aluminium conductor PVC sheathed armoured confirming to IS1556 laid in trenches/along poles/through pipe/through duct complete all as specified and directed |
| 42 | Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule \"A\"/BOQ |