}

Tender For Design, Engineering, Procurement, Construction And Redevelopment Of Dhawari Stadium With Complete Internal Infrastructure And Modern Facilities And ... Facility For A Period 3 Three Years Including 3 Years Defect Liability Period At Satna, satna-Madhya Pradesh

Municipal Corporation-MC has published Tender For Design, Engineering, Procurement, Construction And Redevelopment Of Dhawari Stadium With Complete Internal Infrastructure And Modern Facilities And ... Facility For A Period 3 Three Years Including 3 Years Defect Liability Period At Satna. Submission Date for this Tender is 19-11-2022. Stadium Tenders in satna Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

34666658
Tender For Design, Engineering, Procurement, Construction And Redevelopment Of Dhawari Stadium With Complete Internal Infrastructure And Modern Facilities And ... Facility For A Period 3 Three Years Including 3 Years Defect Liability Period At Satna
Open Tender
Indian
Madhya Pradesh
satna
19-11-2022

Tender Details

Design, Engineering, Procurement, Construction And Redevelopment Of Dhawari Stadium With Complete Internal Infrastructure And Modern Facilities And ... Facility For A Period 3 Three Years Including 3 Years Defect Liability Period At Satna ( M.P. )

Key Value

Document Fees
INR 20000 /-
EMD
INR 636200.0 /-
Tender Value
INR 6.36 Crore /-

BOQ Items

Name of Work: Design, Engineering, Procurement, Construction and Redevelopment of Dhawari Stadium with complete internal infrastructure & modern facilities and Maintenance of entire facility for a period [3] Three Years including 3 [Three] years Defect Liability Period at Satna, Madhya Pradesh
Sl. No. Item Description
1Demolition of parts of existing Stadium
2Demolishing cement concrete manually/by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in Charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix).
3Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in Charge.In cement mortar.
4Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in Charge: In cement mortar.
5Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
6Carriage of material By Mechanical Transport including loading, unloading and stacking:- excavated rock
7Building works in the Stadium
8Earth work in excavation for foundation, trenches for pipes / cables or drains etc. by mechanical means /manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides, disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed. All kinds of soil
9Filling by available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
10Carriage of material By Mechanical Transport including loading, unloading and stacking:-Excavated rock,2 KM lead
11Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : Cement concrete grade M-10 (Nominal Mix) with 20mm maximum size of stone aggregate
12Centering and shuttering including strutting, propping etc. and removal of form for :
13Foundations, footings, bases of columns, etc. For mass concrete.Sides of bottom
14Centering and shuttering including strutting, propping etc.and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts.
15Centering and shuttering including strutting, propping etc.and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers.
16Centering and shuttering including strutting, propping etc.and removal of form for :Suspended floors, roofs, landings, balconies and access platform.
17Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/Cum. Excess/less cement used as per design mix is payable/recoverable separately).
18All work up to Plinth level
19All work above Plinth level up to 2 floor level
20Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/ inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of IS : 13920; IS 456 & SP : 34) etc. complete. Thermo-Mechanically Treated bars. (TMT/TMX) FE 500 or more conforming to IS 1786
21Brick work with chimeny brick of class designation 40 in superstructure above plinth level upto floor 2 level including the cost of scaffolding in : Cement mortar 1:6 (1 cement : 6 coarse sand)
22Half brick masonry with of class designation 40 in super structure above plinth level up to floor 2 level including the cost of scaffolding. Cement mortar 1:4 (1 cement : 4 coarse sand)
23Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position : Second Class Teak wood
24Providing and fixing panelled or panelled and glazed wooden shutters for doors, windows and clerestory windows including ISI marked M.S pressed bright finished butt hinges with necessary screws excluding, panelling / glazing which will be paid for separately. 35 mm thick shutters second class teak wood
25Providing and fixing factory made UPVC door frame made of UPVC extruded section having an overall dimension as below (tolerance±1mm) with wall thickness 2.0mm±0.2mm, corners of the door frame to be mitred and welded of plastic, galvanized brackets and stainless steel screws.The hinge side vertical of the frames reinforced by galvanized M.S.tube of size 19 X 19mm and 1mm ±0.1mm wall thickness and 3nos. stainless steel hinges fixed to the frame complete as per manufacturers specification and direction of Engineer-in-charge
26Providing and fixing panelled or panelled and glazed wooden shutters for doors, windows and clerestory windows including ISI marked M.S pressed bright finished butt hinges with necessary screws excluding, panelling / glazing which will be paid for separately. 35 mm thick shutters second class teak wood
27Providing andfixingaluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriateZsectionsand othersections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or withfixingclips,orwithexpansionhold fasteners including necessary filling up ofgaps at junctions,at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and thedirections of Engineer-in-charge. (Glazing and paneling to be paid for separately) :Powder coated aluminium (minimum thickness of powder coating 50 micron)
28For shutters of doors, windows & ventilatorsincluding providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately).Anodised aluminium(anodised transparent or dyed to required shade according to IS:1868,Minimum anodic coating of grade AC15) Powder coated aluminium (minimum thickness of powder coating 50 micron)
29Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in- charge (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness
30Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete. Fixed to steel windows by welding.
31Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete :250 x 16 mm
3212 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
3315mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand)
346 mm cement plaster of mix :1:3 (1 cement: 3 fine sand) for soffit of beam ,slab ,ceiling etc.
35Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade
36Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm).
37Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
38Providing and laying vitrified floor tiles (without Soluble salt) or printed (with soluble salt) Nano polished (Glossy finish) in different sizes with water absorption less than 0.05% and conforming to IS : 15622 of approved make in all colours & shades, Ist quality/ premium quality in flooring laid on 20mm thick cement mortar 1:4 (1 cement : 4 sand) including grouting the joints with white cement and matching pigments etc. complete. Size 600x600mm as per manufacturer specification.
39Providing and laying vitrified floor tiles (without soluble salt) or printed (with soluble salt) Nano polished (Glossy finish) in different sizes with water absorption less than 0.05% and conforming to IS : 15622 of approved make in all colours & shades, Ist quality/ premium quality in skirting laid on 12mm thick cement mortar 1:4 (1 cement : 4 sand) including grouting the joints with white cement and matching pigments etc. complete. Size 600x600mm thickness as per manufacturer specification).
40Providing and laying rectified Glazed Ceramic floor tiles 300x300 mm or more (8mm to 10mm thick) of 1st quality conforming to IS : 15622 of approved make in and colours laid on 20mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including grouting the joints with white cement and matching pigments etc., complete.
41Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (6 to 7mm thick) of approved make in all colours, shades of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry including pointing in white cement mixed with pigment of matching shade complete.
42Granite work gang saw cut (polished and machine cut) of thickness 18mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement : 3 sand) including pointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade: (To be secured to the backing by means of cramps, which shall be paid for separately). Fine grained granite dark Black/dark Red/ White with self design/ pattern/crystals of other colors of glitter
43Cement concrete flooring M-15 (nominal mix) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm maximum size of stone aggregate.
44Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete
45Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer"s specifications including appropriate priming coat, preparation of surface, etc. complete.
46Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing andmakingcurvature(whereverrequired)andfittingthesamewith necessary stainless steel nuts and bolts complete i/c fixing the railing with necessary accessories and stainless steel dash fasteners , stainless steel bolts etc.,of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval ofEngineer-in-charge. ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
47Making plinth protection 50mm thick of Cement concrete grade M10 (Nominal Mix with 20 mm maximum size of stone aggregate) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
48Providing and fixing sheet covering over expansion joints with iron screws as per design.Aluminium fluted strips 3.15mm thick.150 mm wide.
49Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) After surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. b) Laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) Third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all around.
50Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with on prepared surface, mixing by mix in place method at OMC, and compacting with vibratory roller to achieve the desired density, complete in all respect and as per relevant clauses of section-400.for grading- I Material
51MISCALLANEOUS WORK - finishing works for Sitting arrangements - Steps
5218mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 (1 cement :5 coarse sand finished with a top layer 6mm thick cement plaster 1:4 (1 cement: 4 fine sand).
53Floor painting with floor enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work.
54Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : Old work (one or more coats)
55Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing andmakingcurvature(whereverrequired)andfittingthesamewith necessary stainless steel nuts and bolts complete i/c fixing the railing with necessary accessories and stainless steel dash fasteners , stainless steel bolts etc.,of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval ofEngineer-in-charge. ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
56Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:
57Storm Drain
58Earth work in excavation for foundation, trenches for pipes / cables or drains etc. by mechanical means /manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides, disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed.All kinds of soil
59Filling by available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
60Carriage of material By Mechanical Transport including loading, unloading and stacking:- Excavated Earth,5 KM lead
61Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : Cement concrete grade M-10 (Nominal Mix) with 20mm maximum size of stone aggregate
62Centering and shuttering including strutting, propping etc. and removal of form for :
63Foundations, footings, bases of columns, etc. For mass concrete.Sides of bottom
64Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc
65Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/Cum. Excess/less cement used as per design mix is payable/recoverable separately). Cement concrete grade M-25 (Nominal Mix) with 20mm maximum size of stone aggregate. For Drain Wall and Raft
66Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/ inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of IS : 13920; IS 456 & SP : 34) etc. complete. Thermo-Mechanically Treated bars. (TMT/TMX) FE 500 or more conforming to IS 1786
67Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/Cum. Excess/less cement used as per design mix is payable/recoverable separately). Cement concrete grade M-25 (Nominal Mix) with 20mm maximum size of stone aggregate. For Drain Cover
68Chain Link Fencing
69Providing and fixing Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete.
70Cement concrete grade M-7.5 (Nominal Mix) with 40 mm maximum size of stone aggregate for footing of posts
71Providing and fixing G.I. chain link fabric fencing of required width and mesh size including strengthening with 2mm dia wire or nuts, bolts and washers as required complete with posts of specified material and of standard design placed and embedded in cement concrete blocks 45x45x60cm of mix 1:5:10 (1cement :5 sand :10 graded stone aggregate 40mm nominal size) every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and struts embedded in cement concrete blocks 70x45x50cm of the same mix, as per the direction of Engineer- in charge. (Cost of post, painting, earthwork and CC to be paid separately)Made of G.I. wire.
72Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture
73Road, Parking and Turfing
74Earth work in excavation for foundation, trenches for pipes / cables or drains etc. by mechanical means /manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides, disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed.
75Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m.
76Carriage of material By Mechanical Transport including loading, unloading and stacking, Carting away of excavated earth up to 5 KM lead
77Providing and laying 80 mm thick factory made cement concrete interlocking paver block of M -40 grade made by block making machine with strong vibratory compaction and of approved size and design/ shape laid in required colour and pattern over and including 50mm thick compacted bed of Stone dust sand, filling the joints with coarse sand etc. all complete as per the direction of Engineer-in-charge.
78Providing and laying Selected type of Grass turf with earth 50mm to 60mm thickness on existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller,making the surface smoothen and light watering the same, as per direction of Engineer-in-Charge.
79Plumbing
80Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : Flat back wash basin of size 630x450mm.
81Providing and fixing 16mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand)withjoints treated withwhitecement, mixed with matching pigment, epoxy touch ups,includingrubbing,curing,moulding and polishing to edge to give high gloss finish etc. complete at all levels.Granite of any colour and shade.Area of slab over 0.50 sqm.
82Providing and fixing CP brass waste coupling of approved quality and make for sink and wash basin. Waste coupling 38mm of 83mm length and 77mm breadth, weighing not less than 60gms.
83Providing and fixing PTMT soap Dish Holder having length of 138mm,breadth 102mm, height of 75mm with concealed fitting arrangements. Weighing not less than 106 gms.
84Providing and fixing hand dryer - Polycarbonate ABS body, Blowing volume of 90-270 cum/hr, air speed 90m/s and with auto cut offtime of 15 sec.Make - ANY approved by Engineer -in -charge .
85Providing and fixing Tissue paper dispenser - wall mounted napkin dispenser with a maximum number of wipes tissue holding capacity of 200.Overal size of dispenser should not be less than 315mmL 79mmW 325mmD. Make ANY approved by Engineer -in -charge .
86Supply & fixingof Modular Restroom Cubicles including all accessories like Adjustable foot, Gravity hinges (Right /Left), Coat Hook with door Stopper, Door Knob ,Lockset with indicator, Wall Bracket, Corner connector,Top Rail ,Screws & Wall Plugs, Noise Deafening tapes for grooves in doors complete as per the scope of work and directed by Engineer in Charge
87Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing and fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
88Providing and fixing in position best Indian Health Faucet with 8mm dia 1 meter long Flexible Tube and wall bracket with N. R. V. (non-return valve).(Premium Range Sanitary Ware)
89Providing and fixing PTMT bib cock of approved quality and colour.15 mm nominal bore, 165mm long. Weighing not less than 110 gms.
90Providing and fixing toilet paper holder :C.P. brass
91Providing and fixing in position best Indian Auto Closing 32mm, Flush valve (for W. C. European and Wall Hung Type) concealed type (with DECOL technology/cartridge). (Premium Range)
92Providing and fixing UPVC trap of self cleaning design complete. Including cost of cutting and making good the wall and floors. 100 mm inlet and 75 mm outlet
93Providing and fixing uPVC soil and waste pipes conforming to IS:13592 Type B including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.Single socketed pipes for working pressure of 4 kg/sqcm. (straight type syphon uPVC WC pan connecter with neoprene rubber ring) and necessary accessories etc.,complete- 110mm dia minimum wall thisckness 3.2mm
94Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre and post flushing with water ( 250 ml and 500 ml consumption), having water inlet from back side, including fixing to wal
95Providing & Fixing 8mm thick froasted Urinal glass partition size 900x450mm brass made bracket with. (Premium Range)
96Electrical
97Compact Substation: Design, supply, installation, testing and commissioning of compact outdoor substation comprising of HV compartment for 33/.433KV, Dyn11, oil or dry type resin cast transformer (copper wound) with standard accessories 1 no. of 33 KV, 630A, 25KA, 3 phase 50 HZ vacuum circuit breaker and 1 no. of 33 KV, 100A, 50KA, 3 phase 50 HZ Isolator (non - extensible RMU)connection on H.T side with single core H.T. cable and standard accessories, connection on LV side insulated aluminium busbar of required rating, compartment comprising of MCCB"s 4 pole, and standard voltmeter 0 - 500 V with VSS, ammeter with ASS of required rating, LED indicator (RYB) 22.5mm dia.315KVA, 33/0.4KV O/G MCCB 4P - 1 Nos 630A 36KA, 1 No 300A 36KA
98Silent DG SET Supplying, installation, testing and commissioning of Silent Type DG Sets, AMF Panel, Bus Ducting/ Cables from DG Sets to Essential Panel, Synchronizing Panel where required, DG Set enclosure room sound insulation/ ventilation/ smoke exhaust as required, Earthing of DG Set system, control cabling, Fuel tank/ piping, DG set Exhaust piping/ Exhaust Chimney as per CPCB norms, Civil works connected with DG Sets including Foundation as required. DG set of 300 KVA complete
99LT Panel (PCC) & Accessories: Panel Enclosure: SITC of wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel made out of CRCA sheet, required hardware, duly painted by two coats of zinc/ red oxide primer followed by Powder coated/ epoxy/ PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel, hinged door with locking arrangement for equipment/ switchgear. Thickness of sheet shall not be less than 1.6mm up to 600mm length/ width of any compartment and be of 2.0mm above 600mm. Load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel, if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator).
100Aluminium Bus Bar Supplying and fixing of Aluminiumbus bar by means of SMC/ DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending, cutting in required shape and size and colour coding with heat shrinkable PVC sleeves.
101Incomer/(s):- SITC of quick make and quick break 4 POLE current limiting MCCB having following current rating, short circuit breaking capacity at 440/ 415 V, 50 Hz; O/L & S/C settings and conforming to IS 13947-2 / IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR, shunt trip, earth fault trip, push (test) to trip, including making connections with lugs/spreaders etc. as required (With Microprocessor Release) 630 Amp , 35/50 kA, adjustable O/L & adjustable S/C
102MCCB Accessories: Supply and fixing of following accessories for MCCB Shunt Trip Rease
103SF of CT operated direct reading type Ampere meter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Analog type (96 mm x 96 mm ) - 1 no for each incomer
104SF of Current Transformer, with all necessary support in existing panel including connection etc. as required. from 500 / 5 to 1600/5 Ratio , 15 VA , class 1 accuracy (Set of 3 nos each for Mains & DG supply incomer)
105SF of Current Transformer, with all necessary support in existing panel including connection etc. as required. from 500 / 5 to 1600/5 Ratio , 15 VA , class 1 accuracy (1 no for APFC load sensing ckt)
106SF of CT linked selector switch of 10A for Ampere meter (4 position) including making connection etc. as required. (1 no for each Ameter)
107Phase Indicating Lamps- Supply & fixing of 240/ 220 V, LED (22.5 mm dia) Pilot lamp with integral circuit, terminal block, including connection etc. as required. Red/ Yellow/ Blue (Set of 3 nos for each incomers)
108P & F of energy analyser (multy function energy meter) with LCD/ LED display capable of minimum 20 numbers electrical parameters display with 1A/5A CT input for LV/ HV network, RS 485 communication port etc. complete in all respect. (1 no for each Incomer)
109Outgoing/(s): SITC of quick make and quick break 3 POLE current limiting MCCB having following current rating, short circuit breaking capacity at 440/ 415 V, 50 Hz; O/L & S/C settings and conforming to IS 13947-2/ IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR, shunt trip, earth fault trip, push (test) to trip, including making connections with lugs/spreaders etc. as required (With Thermal Magnetic Release) up to 100 Amp, 16/ 25 kA, adjustable O/L & fixed S/C setting
110160 Amp, 25 kA, adjustable O/L & fixed S/C setting
111ON/ OFF Indicating Lamps- Supply & fixing of 240/220 V, LED (22.5 mm dia) Pilot lamp with integral circuit, terminal block, including connection etc. as required. Red/ Green (Set of 2 nos for each outgoing)
112Internal Illumination System: Lighting Distribution Boards: (Location - Indoor) Supplying of approved make TPN MCB DB Metal Double Door IP 43 protection with provision for FP MCB/ Isolator/ RCCB/ RCBO as incomer and SP MCBs as outgoing inclusive of Bus bar, Neutral bar, Earth bar & two earth terminals etc. complete as per IS:13032 (exclusive of MCB & isolator); 4way (8 +12)
113Supplying of approved make TPN MCB DB Metal Double Door IP 43 protection with provision for FP MCB/ Isolator/ RCCB/ RCBO as incomer and SP MCBs as outgoing inclusive of Bus bar, Neutral bar, Earth bar & two earth terminals etc. complete as per IS:13032 (exclusive of MCB & isolator); 8way (8 +24)
114Labour charges for fixing sheet steel enclosures, MCB DB flush mounting type, as per accepted practice, duly embedded and end plate completely flushed in wall, cable connection etc. complete.
115Supplying and installing of RCBOs (Residual current circuit breaker with overload and short circuit protection) ISI marked complete as per I.S. standard confirming to IEC: 61009-2-1 & IS:12640-2:2001, 240/ 415V 50 Hz with 10 kA short circuit withstand capacity for earth leakage, overload & short circuit protection including connection in existing enclosure in approved manner as per specification; 4 pole 25-32 Amps, 30 mA sensitivity
116Supplying of ISI Marked and accepted standard of Miniature Circuit Breaker (MCB) of "C" series suitable for 240/415 Volts, 50 Cycle , 10 kA Value AC supply confirming to IS: 8828: 1996, IEC: 60898: 2002 but without enclosures; 6 Amp to 32 Amp Rating
117Fixing of MCB/ MCCB/ Isolator in sheet steel enclosure as required as per accepted practice, including mounting on busbar and cable connection etc. complete (Labour only); MCB / Isolator SP/DP
118Sub Lighting Distribution Boards: (Location - Indoor) Supply of approved make powder coated sheet steel encloser SPN MCB DB inclusive of Bus bar, Neutral bar, Earth bar & two earth terminals etc. complete as per IS:13032 (exclusive of MCB & isolator); 4 way Double Door IP 43 protection
119Labour charges for fixing sheet steel enclosures, MCB DB flush mounting type, as per accepted practice, duly embedded and end plate completely flushed in wall, cable connection etc. complete.
120Supplying and installing of RCBOs (Residual current circuit breaker with overload and short circuit protection) ISI marked complete as per I.S. standard confirming to IEC:61009-2-1 & IS:12640-2:2001,240/415V 50 Hz with 10 kA short circuit withstand capacity for earth leakage, overload & short circuit protection including connection in existing enclosure in approved manner as per specification; 2 pole, 6-25 Amps, 30 mA sensitivity
121Supplying of ISI Marked and accepted standard of Miniature Circuit Breaker (MCB) of "C" series suitable for 240/415 Volts, 50 Cycle , 10 kA Value AC supply confirming to IS: 8828: 1996, IEC: 60898: 2002 but without enclosures; 6 Amp to 32 Amp Rating
122Fixing of MCB/ MCCB/ Isolator in sheet steel enclosure as required as per accepted practice, including mounting on busbar and cable connection etc. complete (Labour only); MCB / Isolator SP/DP
123Point Wiring - Light/ Fan Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp, holders, ceiling roses etc) with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI Marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit etc. as required as per specification for Light/ Fan Points (using modular accessories); Short Point (up to 3 mtr.)
124Medium point (above 3 mtr up to 6 mtr.)
125Long point (above 6 mtr up to 10 mtr)
126Point Wiring- Light Plug Point Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp, holders, ceiling roses etc) with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI Marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit etc. as required as per specification for 3 Pin 6 Amp Socket outlet on separate box (using modular accessories); Short Point (up to 3 mtr)
127Medium point (above 3 mtr up to 6 mtr.)
128Long point (above 6 mtr up to 10 mtr)
129Point Wiring-Call Bell/ Buzzer Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp, holders, ceiling roses etc) with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI Marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit etc. as required as per specification for Call bell/ Buzzer Points (using modular accessories) Short Point (up to 3 mtr,)
130Medium point (above 3 mtr up to 6 mtr.)
131Long point (above 6 mtr up to 10 mtr)
132Point Wiring -Twin Control Light Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp, holders, ceiling roses etc) with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI Marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit etc. as required as per specification for Twin Control Light Points (using modular accessories); Short Point (up to 3 mtr.)
133Medium point (above 3 mtr up to 6 mtr.)
134Long point (above 6 mtr up to 10 mtr)
135Circuit/ Submain Wiring Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
1362 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1372 X 4 sq. mm + 1 X 4 sq. mm earth wire
1384 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
1394 X 4 sq. mm + 2 X 4 sq. mm earth wire
140Point Wiring- Light Power Point Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. Socket Outlet Point With 4 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in Concealed rigid P.V.C Conduit (HMS) ISI Marked of suitable size etc. with 16 Amp. F.T. Switch & Socket/ S.S. Combined 6/16 Amp. of ISI Marked and 4 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit as per specification for same board switch socket 6/16A (using modular accessories);
141Modular Type Metal Box Supplying and fixing of approved make modular type metal box with modular frame/ base plate and cover plate including fixing in concealed / surface excluding switch, socket etc. as required for; 3 module
1424 module
1436 module
1448 module
145Modular Type PVC Box Supplying and fixing of approved make modular type P.V.C. box with modular base and cover plate including fixing on surface excluding switch, socket etc. as required for; 3 module
1464 module
1476 module
1488 module
149Call Bell/ Buzzer Supplying and fixing as per specification Call bell / buzzer of approved make with necessary materials complete.
150Modular Bell Push Switch Supplying and fixing as per specification 6 Amp 250 Volt Bell Push switch of approved make ISI marked with necessary material complete. 6/10 Amps S.P. 250 Volt Modular Switch Bell Push
151Electric Ceiling Fan Supplying, erection and testing of approved make electric Ceiling fan of double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, AC 230-250 volts including connections with all necessary material complete of approved as required confirming to IS :374/1979 with up to date amendments. Ceiling Fan (5 star & ISI)-1200 mm Sweep
152Ceiling rose Supply and fixing as per specification polycarbonate ceiling rose 3 plate of approved make ISI marked with necessary material complete.
153Modular Electronic Fan Regulator Supplying and fixing of approved make step type Modular electronic Fan regulator including connection etc. as required on existing board 100 Watt (2 module)
154Exhaust Fan (Heavy Duty) Supplying, erecting and testing of approved make Exhaust Fan heavy duty with mounting frame, blades AC 230-250 complete connection and including, frame bolt/ Anchor hole fastners etc. complete finished of approved as required. 300mm sweep 900 RPM
155Exhaust Fan Louvers Supply and fixing of GI sheet 24 SWG Exhaust fan Louvers including grouting bolt, nut, & finishing etc on existing hole to complete the job as mentioned below: Sweep 300mm
156Bulk Head Light P & F of IP65 IK10 rated LED bulk head type ligh fixture made from CRCA sheet steel housing suitable for mounting LED tube system (integral driver), Powen consumption of 10-15W, 500-600 lumens system lumen efficiecy 70 lm/ watt output suitable for1x100 W GLS/ 9W CFL bulk head fixtures, life time of 50000 burning hours with 70% initial lumen maintained. CCT 3000° K, 4000° K and 6000° K. Fixture shall be in compliance with CE & KEMA standards. 9/10W Bulk Head LED
157Supplying, fixing and testing of approved make modular integral step / skirt LED light suitable for 3 module box and plate including fixing on wall as required, with necessary material complete
158LED Downlighter P&F of 24W, High efficient Surface mounted LED round downlighter with white powder coated, pressure die cast aluminium housing. High transmittivity PS diffuser provides soft light. CRI>80, IP40 Housing , Ambient temp -0 to 45 DegC, CCT - 4000/5700K, 50,000 hrs @ L70 life. Driver efficiency>85%, THD<10%, Powerfactor > 0.95, Surge protection -2.5 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 90-265V AC and Safety Extra Low Voltage Safe level <60V DC as per IEC standard.Luminaire lumen = 2400 lm. (100 lm/W) - Cutout Dia- ø168 mm, similar to Wipro LD06-301-XXX-57-WSM Mollis Surface DownLighter/ equivalent Make & Model.
159LED Street Light Supply of SMD 45W LED Streetlight fixture with System efficacy of 110 lm/W (4950 lumens). Luminaire shall be made up of die cast Aluminium housing with PC lens and ploycarbonate diffuser. Luminaire shall be designed with street optic LENS for uniform light distribution. LM 80-08 compliant LEDs from reputed makes such as Nichia/Cree/ Bridgelux/ Lumiled/ Osram/Seoul should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Luminaire shall be with IP66 protection. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K and CRI of Minimum 70. LED Driver shall be potted, Integrated type, Multistage, Isolated, APFC Constant Current-Constant Voltage operated driver with range 150-270V AC and Safety Extra Low Voltage < 60V DC as per IEC standard., Driver Efficiency > 85% & 4 KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Compliance to Indian Standards of IS10322 Part 5 / Sect 1:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012.
160Lighting Poles & Accessories Octagonal Pole: Providing and erecting hot dipped galvanized octagonal poles in single section made from 3mm thick sheet having lockable weather proof flush door junction box complete erected in an approved manner on provided foundation. Suitable size & type of foundation bolts 4 nos. "J" type (EN8 grade) 6 mtrs. Height 130 x 70mm A/F, 220x220x12mm base plate, 4 nos. x M20 x 600mm bolt for above Solar Light.
161GI Bracket: Providing and fixing of sword canopy type single arm GI bracket up to 2 Mtr. Long for 70mm A/F top octagonal pole
162RCC Foundation (6 M Octagonal Pole): Designing & casting with M-20 reinforcement cement concrete foundation of size 50 x 50 x 120 cms. deep in below ground level with plinth of 50 cms x 50 cms (or 50 cms dia) x 20 cms above ground level suitable for Conical Poles considering the safe soil bearing capacity at site as 10 T/sqm at 2 mtrs. depth including excavation, foundation nut bolts with necessary curing and finishing in an approved manner.
163Power & Control Cables: 11kV Grade XLPE Insulated (AL) Cables Supplying 11kV(E) 3 core power cable of following size 150 sqmm
1641100V Grade XLPE/ PVC Insulated (AL) Cables Supply of XLPE Insulated power cable (confirming IS-7098 Part-I) 1100 Volt grade, 1 core/ 2 core/ 3½ core/ 4 core ISI MARKED with Alu. Stranded conductor 3 CORE ARMOURED - 10 sq.mm
1653 CORE ARMOURED - 25 sq.mm
1663 CORE ARMOURED - 50 sq.mm
1671100V Grade XLPE/ PVC Insulated (AL) Cables Supply of XLPE Insulated power cable (confirming IS-7098 Part-I) 1100 Volt grade, 1 core/ 2 core/ 3½ core/ 4 core ISI MARKED with Alu. Stranded conductor 3½ CORE ARMOURED - 50 sq.mm
1683½ CORE ARMOURED - 150 sq.mm
1693½ CORE ARMOURED - 240 sq.mm
1703½ CORE ARMOURED - 300 sq.mm
1711100V Grade XLPE/ PVC Insulated (AL) Cables Supply of XLPE Insulated power cable (confirming IS-7098 Part-I) 1100 Volt grade, 1 core / 2 core / 3½ core/ 4 core ISI MARKED with Alu. Stranded conductor 4 CORE ARMOURED- 16 Sq. mm
1724 CORE ARMOURED - 25 Sq. mm
1731100V Grade XLPE/ PVC Insulated Copper Cables: Supply of XLPE Insulated power cable (conforming IS7098) 1100 Volt grade/ Heavy duty power cable 2 core / 3 core ISI MARKED with copper stranded / solid conductor 2 CORE ARMOURED - 2.5 sq.mm
1743 CORE ARMOURED - 2.5 sq.mm
1754 CORE ARMOURED - 2.5 sq.mm
1761100V Grade XLPE/ PVC Insulated Copper Multicore Cables: Supply of XLPE/ PVC Insulated multicore control cable (conforming IS7098/ IS 1554), 650/ 1100 Volt grade ISI MARKED with copper stranded conductor of following size; 5 CORE ARMOURED - 1.5 sq.mm
1777 CORE ARMOURED - 1.5 sq.mm
17810 CORE ARMOURED - 1.5 sq.mm
17912 CORE ARMOURED - 1.5 sq.mm
1801100V Grade HRFR/ FRPVC Insulated Copper Cables: Supplying and fixing of multi core round HRFR/ FR PVC insulated copper (flexible) conductor & PVC sheathed cables 1100 Volts as per IS:694-1990 of approved make of following size. (30/ 0.25 mm) Three core 1.5 sq.mm. (for JB to Lighting fixtures)
181(50/ 0.25 mm) Three core 2.5 sq.mm. (for JB to lighting fixtures)
182(56/ 0.3 mm) Three core 4.0 sq.mm. (for AC/ lighting power circuit etc)
1831100V Grade PVC Insulated Copper Submersible Cables: Providing and laying ISI marked P.V.C. insulated submersible cable confirming to IS:694 with flexible copper conductor including making connection etc. as required 3c x 4 Sqmm PVC Submersible Cable (Cu)
1843c x 6 Sqmm PVC Submersible Cable (Cu)
185Cable End Terminations: HT Cable End Terminations- Supplying & making Indoor/ outdoor cable end termination of following size(s) of 3 core aluminium conductor cable. 120 -185 sq. mm, Heat Shrinkable (Indoor)
186120 -185 sq. mm, Heat Shrinkable (Outdoor)
187LT Cable End Terminations- Supplying and making end termination with brass compression gland and aluminium lugs for following size of XLPE/ PVC insulated and PVC sheathed aluminium conductor cable as required. 3½ X 35 sq. mm (32mm)
1883½ X 50 sq. mm (35mm)
1893½ X 70 sq. mm (38mm)
1903½ X 150 sq. mm (50mm)
1913½ X 185 sq. mm (57mm)
192LT Cable End Terminations- Supplying and making end termination with brass compression gland and aluminium lugs for following size of XLPE/ PVC insulated and PVC sheathed aluminium conductor cable as required. 4 X 10 sq. mm (25mm)
1934 X 16 sq. mm (28mm)
194RCC Hume/ Metal/ HDPE Pipes for Cables: RCC Hume Pipe- Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 150 mm dia
195GI Pipe Sleeves- Supplying & installing G.I. Pipe for protection of underground cable fixed on wall/support/in trench/fixed between two rigid existing support of wall/beam for erection of ceiling Fan/down rod for stiff pendent for light luminaries/ fan/ protective for earthing, lightening conductor down strip/overhead service line/for submersible cable or centrifugal pump for water supply with necessary iron clamp coupler, bend, tee, elbow, nuts and bolts etc. complete in an approved manner as required to complete excluding cost of excavation/ dismantling & other finished masonry Item complete. 15 mm -"A" Class pipe ISI Marked (IS-1161-68)
19625 mm -"A" Class pipe ISI Marked (IS-1161-68)
19750 mm -"A" Class pipe ISI Marked (IS-1161-68)
198100 mm -"A" Class pipe ISI Marked (IS-1161-68)
199150 mm -"B" Class pipe ISI Marked (IS-1161-68)
200HDPE Pipes- Supplying and installing of double wall corrugated pipes (DWC) HDPE Pipe (IS 14930 Part II -marked ) for cable laid under ground with necessary material and at required depth up to 90cm. below road/ground surface, including excavation, back filling with excavated material, ramming and making the surface good. 63 mm outside dia.
20190 mm outside dia.
202Cable Trays & Accessories: Supply & laying GI ladder type cable trays with side channels of size - 75 x 15 x 15 mm/ 100 x 15 x 15 mm & rungs of size - 35 x15 x 15 mm spaced at 250 mm apart, fabricated from 2 mm thick sheet steel in standard length of 2.5 meter, duly hot dipped galvanized after fabrication as per IS 2629- 1989/ IS 4759-1984 including accessories such as coupler plates/ fish plates, bends, tees, reducers, elbows, covers and electro-galvanized hardware etc, erected on existing support as per specification and instruction of engineer in charge. 300(W) x 75(H) x 2.0 mm Thick
203450(W) x 75(H) x 2.0 mm Thick
204600(W) x 75(H) x 2.0 mm Thick
205Supply & laying GI perforated type cable trays with returned edge/ flange, fabricated from 2.0 mm thk sheet steel in the standard length of 2.5 mtrs, duly hot dipped galvanized after fabrication as per IS 2629-1989/ IS 4759-1984 including accessories such as coupler plates/ fish plates, bends,tees, reducers, elbows, covers and electro-galvanized hardware etc, erected on existing support as per specification and instruction of engineer in charge. 100(W) x 35(H) x 2.0 mm Thick
206150(W) x 35(H) x 2.0 mm Thick
207300(W) x 35(H) x 2.0 mm Thick
208Cable Laying: HT Cable Laying- in existing RCC Hume/ Metal Pipe Laying one number 3 core power cable of following size in the existing RCC/ Hume/ Metallic pipe as required. above 120 sqmm and up to 400 sq. mm.
209LT Cable (Single Run) Laying-directin ground Laying of one number XLPE/ PVC insulated and PVC sheathedpower cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Up to 35 sq. mm
210Above 35 sq. mm and up to 95 sq. mm
211Above 95 sq. mm and up to 185 sq. mm
212Above 185 sq. mm and up to 400 sq. mm
213LT Cable (Additional Run) Laying -directin ground Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. Up to 35 sq. mm
214Above 35 sq. mm and up to 95 sq. mm
215Above 95 sq. mm and up to 185 sq. mm
216Above 185 sq. mm and up to 400 sq. mm
217LT Cable Laying- in existing RCC Hume/ Metal/ HDE Pipe Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Up to 35 sq. mm
218Above 35 sq. mm and up to 95 sq. mm
219Above 95 sq. mm and up to 185 sq. mm
220Above 185 sq. mm and up to 400 sq. mm
221LT Cable Laying- on existing Cable Trays Laying and fixing of one number XLPE/ PVC insulated and PVC sheathed power cable of 1.1 KV grade of following size on cable tray as required.Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Up to 35 sq. mm (clamped with 1mm thick saddle)
222Above 35 sq. mm and up to 95 sq. mm (clamped with 25x3mm MS flat clamp)
223Above 95 sq. mm and up to 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
224Above 185 sq. mm and up to 400 sq. mm (clamped with 40x3mm MS flat clamp)
225Cable Pull Pits/ Chambers: Construction of brick masonry pulling chamber of required size and depth up to 0.6 meter with 230 mm thick masonry in cement mortar proportion 1:6, 12 mm thick cement plaster in CM 1:4in both side, 150 mm thick PCC M-10at bottom, 100 mm thickR.C.C M-20 coping at top of wall, 100 mm thick precast concrete cover in RCC M-20. including excavation and back filling & clearing the site by removing debris & Shiftingof the debris & making site good as per the Instruction of the Engineer In charge complete in all respect. 450 mm x 450 mm inside clear size
226600 mm x 600 mm inside clear size
2271000 mm x 1000 mm inside clear size
228Excavation Work Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift up to 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. (for equipment foundation/ embeddingmetalic pipe sleeve/ Earth Wire/ Strips etc wherever required)
229Excavation for cable trenches of depth up to 1.2 m in soft soil including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres.
230Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift up to 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres.
231Steel Fabrication work: Supply, fabrication and erection of Angle/ Chanel/ Flat iron fitting for cable tray supports, over head line/ sub-station etc such as "D" bracket, cross arms, top clamp, "V" cross arms, Back/ Support clamps or other similar work etc. including nut bolts of required size, making holes, fabrication, welding, cutting, etc. and painting with one coat of red oxide paint & two coat of aluminium paint as required as per specification.
232Cable Route Marker - Supply & Fixing Cable Route Marker round / square size 100mm, 5mm. Thick, G.I. Plate duly bolted/welded on 35mm x 35mm x 5mm angle iron 60cm long including excavation, grouting in cement concrete 1:2:4 (1cement and 2 coarse sand :4 graded stone aggregate 20mm nominal size) foundation of size 20cm x 20cm x 30cm duly embedded in ground 30cm depth or as required.
233Earthing System: Earth Electrodes (for 33/ 11kV DP/ Trafo/ DG/ Motor/ SWGR) Pipe Earthing as per IS:3043 with perforated 3.0 Mtr. Long, 40 mm dia. " B " class G.I. Pipe including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size- 300mm x 300 mm and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance as required.
234Earth Electrodes (for Trafo/ DG Neutral) Plate Earthing as per IS:3043 with copper Earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. "B" class watering Pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size- 300mm x 300mm complete with alternate layers of salt and coke/ charcoal, testing of earth resistance as required.
235Earth Wire/ Strps S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. 8 SWG GI Wire (for LPBs, JBs & Lighting Pole etc)
23632mm x 6mm copper strip (for small rating trafo/ DG neutral)
23725x6 mm size GI earth strip (for small rating equipment/ cable tray
23832x6 mm size GI earth strip (For small rating equipment - Trafo/ DG, SWGRetc and for use as ground conductor)
23950x6 mm size GI earth strip (For higher rating equipment - Trafo/ DG, SWGRetc and for use as ground conductor)
240GI Pipe (Class A) S & Laying following size" A" class G.I. Pipe with accessories for laying earth conductor/strip in ground/surface/recess as required 15 mm dia.
24120 mm dia.
242Earthing for Lighting Pole Providing MS Rod Earth Electrode (20 mm dia x 1.5 m long) with required length of 6SWG GI wire for individual lighting pole earthing.
243Electrical & Fire Safety Equipment: Supplying & fixing of Fire Extinguisher/ Refills as per IS specification ABC type duly refilled 4 Kg & ready to use
244ABC type refill only 4 Kg
245Providing 4 buckets set with sand, self supported M.S.stand including shed duly painted with red colour as per IS.
246Rubber mat 2m x 1m, 1100V
247Hand Gloves 11KV Tested
248Fiber Discharge Rod includingConn copper Lead Tested
249Supply of First Aid Box complete with medicine & bandage as per specification. First Aid Box shall consists of standard makes- antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-aid) adhesive tape for medicinal user, Scissors, anti-septic solution (Savlon or similar) etc.
250Electric Shock Instruction Chart duly framed with glass, as reqd.
251Supplying and fixing as per specification Caution/ Danger Board as of approved make & design with necessary material complete. (Large Size)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail