Tender For 8233 Repair / Maint Of Lt Distribution System, Lt Cable, Replacement Of Transformer, Dehydration, Lt Panel, Improvement To Mes Installation And Security Street Lights Gate Light / Ptls, Dg Sets At Rts And Depot Hempur Under Ge (East) Barei, bareilly-Uttar Pradesh

Military Engineer Services-MES has published Tender For 8233 Repair / Maint Of Lt Distribution System, Lt Cable, Replacement Of Transformer, Dehydration, Lt Panel, Improvement To Mes Installation And Security Street Lights Gate Light / Ptls, Dg Sets At Rts And Depot Hempur Under Ge (East) Barei. Submission Date for this Tender is 24-11-2022. Diesel Generators Tenders in bareilly Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

34651549
Corrigendum : Tender For 8233 Repair / Maint Of Lt Distribution System, Lt Cable, Replacement Of Transformer, Dehydration, Lt Panel, Improvement To Mes Installation And Security Street Lights Gate Light / Ptls, Dg Sets At Rts And Depot Hempur Under Ge (East) Barei
Open Tender
Indian
Uttar Pradesh
bareilly
24-11-2022

Tender Details

Repair / Maintenance Of Lt Distribution System, Lt Cable, Replacement Of Transformer, Dehydration, Lt Panel, Improvement To Mes Installation And Security Street Lights Gate Light / Ptls, Dg Sets At Rts And Depot Hempur Under Ge ( East ) Bareilly.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-Nov-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 24-11-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 59000.0 /-
Tender Value
INR 29.50 Lakhs /-

BOQ Items

NAME OF WORK: REPAIR / MAINT OF LT DISTRIBUTION SYSTEM, LT CABLE, REPLACEMENT OF TRANSFORMER, DEHYDRATION, LT PANEL, IMPROVEMENT TO MES INSTALLATION AND SECURITY STREET LIGHTS GATE LIGHT / PTLS, DG SETS AT RTS AND DEPOT HEMPUR UNDER GE (EAST) BAREILLY.
Sl. No. Item Description
1Dismantling cross arms of MS channel or angle section, MS clamps etc compelte all as specified and directed.
2Dismantlinginsulators of any type, any size carefullyandkeeping at site forre-use etc complete all as specified and directed.
3Dismantling stay assembly including demolition PCC and earth work compelte all as specified and directed.
4Dismantling of ACSR conductors of any type and size complete all as specified and directed.
5Dismantling earth wire of any type and size complete all as specified and directed.
6M&L forpin type porcelaine, vitreous,brown insulator including one galvanised mild steel spindle,two galvanised iron washers and galvanised iron nut, 50 mm height,65 mmdia for 550 Volts grade completed and directed.
7Supply and fixing shackle type insulator, porcelain, white brown, or green insulator of size 100x115mm (Height 100 mm and 115 mm dia) with section strip 31/5 mm and 14 mm boltcomplete all as specified and directed.
8M&L forpin type composite insulation/silicon rubber materialincluding one galvanishing MS spingle, nuts & washers of 150mm height, 150 mm dia for 11000 volt grade and fixing to the pole/structure and binding of conductor including taking down complete all as specified and directed.
9M&L fordisc type composite long rod insulator HT 11 KV out door type withcomposite insulating/silicon rubber materials type along with necessary acessories for connection of cables/ACSR conductors including taking down and making of cycle point complete, all as specified and directed.
10M&L for servicing and greasing GOD (gang operated air break switch) 200 Amps triple pole 11 KV including replacement of the following U/S parts :- (a)ACSR Jumper with RYB, PVC sleaves 1.5 m to 2.0 m long – 03 Nos (b)Brass connector brackets with bolts, nuts etc- 3 sets (c)Copper lugs of suitable size
11M&L for taking down HT 11 KV grade tripple pole gange operated Air break switchfrom 4 pole/2 pole structure and S & FNew gang operated Air break switch (GOD) HT 11 KV of 200 A capacity out door type suitable for vertical mounting fixed type complete with 3 no. silicon rubber polymeric insulator per phase all as specified and directed.
12S&F stay assembly set comprising of stay bow, galvanised 16mm dia 400mm long stay rod 16 mm dia GI stay bow, 1800 mm long with nuts, bolts, washers, MS stay plate, 02 Nos thimble and clamp etc required with all accessories as specified Note :- Loop type insulators, excavation, earth work, concrete for foundation shall be measured and paid separately under respective item of Sch "A". PCC shall be measured and paid separately) compelte all as specified and directed.
13S&F loop type insulator large size with over all dimension 90x140 mm clearance of hole 25.5 compelte all as specified and directed
14M&L for galvanised steel standard stay wire of size 3.15mm (70 Kg/Sqmm) grade for stay of poles including necesssary clamps of 50x6mm of flat iron complete all as specified in electtri 300x300x6 mm MS stay plate including thimbles, GI stay wire 7/2.24 mm SWG of required with all accessories as specified and directed.
15M&L aluminium conductor steel reinforcd (ACSR) of any sizefor LT / HT over head conductor on poles including stringing, tightening binding to insulators with aluminium wire making and connecting commissioning and testing compelte all as specified and directed.
16M&L for 7 SWG GI continuous earth wire of size 3.15 mm or 4.00 dia for cradles, gurading and earth continuity on LT / HT OH pole including suitable, binding wires etc completeall as specified and directed.
17M&L forpre-fabricated MSstructural steel (IS marked) work consisting of channels / angles / other sections etc of various sizes and shape, cut / weld / drilled holes etc hot / cold in position for cross arms with FI clamps (full, half D and earth clamp etc) incl necessary MS bolts, nuts etc and painting, all as specified and directed.
18M&L for opening the binding wire from pin / shackle insulator on steel pole of any height for re-stretching theACSR conductor, after re-stretching without kinks & bends, binding the pin/shackle insulator with appropriate size of aluminium binding wire, etc complete all as specified and directed. NOTE :- (i) The above work includes clearing/ prooning of tree branches faling around the conductors. (ii) Cost of binding wiredeemed to be included inthe quoted rate, No extra amount will be paid.
19M&L for preparation of old painted steel surfaces ofLT/HT steel tubular/swaged/rail poles of 9m to 11m long including brackets, clamps, channels and cross arms by cleaning of oils, lubricants, grease etc. complete above PCC coping and applying two coats of aluminium paint on surfaces 1m above PCC coping, applying two coats of synthetic enamel paint in zebra pattern with Aluminium and redcolour combination up to 1m height above PCC coping; writing MES No. of poles (Number size shall be 25mm and lettering shall be 40mm) complete including applying two coats of white wash on exposed concrete surfaces of coping to poles duly preparing the surfaces all as directed.
20Trimming of tree branches along the LT / HT overhead line up to 1.5 mtr from OH line to tree around the parameter, unit area complete all as specified and directed. Note:-Span shall be considered the distance betweenpole to pole.
21M&L in repairs for MCCB 4 pole, 415 volts, adjustable type, 160 Amps with breaking capacity 36 KA compelte all as specified and directed.
22M&L in repairs for MCCB 4 pole, 415 volts, adjustable type, 250 Amps with breaking capacity 36 KA compelte all as specified and directed.
23M&L in repairs for MCCB 4 pole, 415 volts, adjustable type, 630 Amps with breaking capacity 36 KA compelte all as specified and directed.
24M&L in repairs for MCCB 4 pole, 415 volts, adjustable type, 63 Amps with breaking capacity 36 KA compelte all as specified and directed.
25M&L for steel tubular poles complete with cast iron base plate, final taper plug, bolt, nuts and screws as specified type 410 SP-31(9 mtr long). Including painting pole with two coats of bituminous paint internally and external embedded portion in ground concrete and painting exposed surface with two coats of aluminum paint over one coats of aluminum paint over one coat of red oxide primer including taking down of existing LT pole of any size and re-fixing of chaneel, insulatorand electric connection etc, complete all as specified and directed.
26M&L for steel tubular poles complete with cast iron base plate, final taper plug, bolt, nuts and screws as specified type 410 SP-55(11mtr long). Including painting pole with two coats of bituminous paint internally and external embedded portion in ground concrete and painting exposed surface with two coats of aluminum paint over one coats of aluminum paint over one coat of red oxide primer including taking down of existing LT pole of any size and re-fixing of chaneel, insulatorand electric connection etc, complete all as specified and directed.
27Supply and laying XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked as per IS 7098-I laid in trenches ducts or fixing or passing through GI pipe across the road / path / drains / along wall / floor / pole / equipment etc. cross sectional area including cable lugs of following size including taking down of existing cable complete all as specified and directed.
28(a) LT cable 2 Core 10 Sqmm
29(b) LT cable 2 core 16 Sqmm
30(c) LT cable 3.5 core 35 Sqmm
31(d)LT cable 3.5 core 50 Sqmm
32(e)LT cable 3.5 core 70 Sqmm
33(f) LT cable 3.5 core 120 Sqmm
34Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope / gradient for laying cables/pipes etc. including removing cable protection PCC covers/ bricks & stacking serviceable covers / bricks for reuse and disposal of unserviceable covers within 50 m complete all as specified and directed. Note : Excavation shall be made carefully in order to avoid damage of existing cables and protection covers.
35Excavation in trenches not exceeding 1.5 mtr wide andexc 1.5 mtr but n exc 3.0 mtr in depth for foundation, laying of pipe etc and not exceeding 10 sqm on plan for manhole etc and getting out in soft/loose soil, complete all as specified and directed.
36Returning, filling in, including spreading levelling, watering and well ramming in layers not exceeding 25 cm in soft / loose soil complete all as specified and as directed.
37Removing excavated material (soils) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
38Supplying & Laying Sub Class `B’ bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection all as specified and directed
39Supply and laying new dry river sand laid in trenches 8.0cm below the cable and 15.0cm above the cable and gently punned to 18.0cm ascable cushioning and covering complete all as specified and directed. (Note:- Only punned 18 cm thick sand cushioning shall be measured and paid)
40M&L for Cutting/Boringof road/Hard standing to a size of 30 cm in width and not exceeding 60 cm in depth for laying of protection pipe/water line/Cableincluding returning filling, Including spreadingand providing PCC in 1:2:4 B1 using 20 mm grade stone aggregate for the top 100mm layer, complete all as specified and directed.
41Supply and laying galvanised iron pipe 50mm bore light gradefixedto poles withsteel clamps laid under road crossing, fixedto wall etc complete all as specifiedand directed by Engr-in-charge.
42All as per Srl item No. 35 here in before but 25 mm bore
43Material and labour for P.C.C (1:3:6) type C-2 using 40 mm graded aggregate as in foundation of pole and filling of mass concrete including providing necessary form work complete all as specified and as directed.
44M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in coping to poles including necessary form work and applying three coats of white wash over the surfaces of coping including demolition of existing disturbed coping andremoving the debris to a distance n.exc. 50m complete all as specified and as directed.
45M&L for filtration/ dehydration of transformer and servo voltage stabilizeroil including checking di-electric strength of oil before and after filtrationfor various transformers and servo voltage stabilizer located at RTS & Depot area with suitable machine having filtration, heating and pumping facility to improve the dielectric strength/ insulation value of oil. Notes :- (i) Di-electric strength of oil after filtration/ dehydration shall not be less than 60 KV/min. (ii) The contactor shall take shut down orders in writing from Engineer-in-charge before commencement of the work. (iii) The contractor shall ensure no wastage of transformer oil. (iv) The di-electric strength of oil shall be tested before & after filtration and test results shall be submitted to Engineer-in-Charge.
46M&L for spray painting with Silicon acrylic heat resistant paint of approved quality & colour to indoor / outdoor type, step up / step down transformer of up to 400 KVA capacity, installed at different locations at RTS & Depot Hempur area after thoroughly scraping the existing corroded paint / rust, filling of cavities complete without disturbing / damaging the electrical net work system including writing the details such as SM/MES No., capacity / rating / incoming & outgoing details complete, all as specified and as directed.
47Supply and filling new transformer oil for topping up the transformers duly filtered with filtration plant having dielectric strength not less than 60 KV complete all as specified and as directed. [Make : Poweroil/ Electrol/ Savitha/ Tashol/ Servo]. Note :-(a)The transformer oil shall be type EHV confirming to IS - 335/1983. (b)Mineral oil grade shall be used. (c)The IR value of transformer oil shall not be less than 60KV/min. (d)The unit rate shall be deemed to include the cost of filtration to achieve desired di-electric strength.
48S&F new gun metal gate valve of 32mm dia bore [Class-II, 1.6 Mpa] with ISI mark and iron wheel head, screwed both ends to GI pipes including taking down old unserviceable valve all as specified. [Make: Leader/ Bir/ Zoloto]
49Supply & replacement ofLV porcelain bushing of rating 1.1 KV/ 400 Amps complete suitable for indoor/outdoor type, step up/step down transformers of any make/model complete all as specified and directed.
50Supply & replacement ofHV porcelain bushing of rating 11 KV/ 250 Amps complete suitable for indoor/outdoor type, step up/step down transformers of any make/model complete all as specified and directed.
51Taking down unserviceable sheet gasket (Cork sheet), Supply and fix synthetic rubberized cork sheet gasket 6mm thick for top cover HT/LT bushes at places existing and tightening all the bushings and top cover to avoid any oil leakages for transformer of capacityupto 400 KVA complete all as specified and directed.
52Taking out existing oil level invisible glass from conservator tank of transformer and Supply and fix new glass with gasketincluding replacement of silica jell complete all as directed.
53M&L for removing the servo voltage stabilizerfrom the existing position after disconnecting all the connections from the system, servicing, overhauling of the same, checking of the same for proper operation, spring charge, ensuring control cables are fastened tightly to the terminals, checking any abnormality with servo voltage stabilizer, cleaning the surface of the insulators, fasten the bolts, checking and correctinginterrupting units, mechanism, linkages etc, including filteration of insulating oil. Proper checking of oil level top up if required.
54Supply, installation, Testing and Commissioning in repairs of three Phase four wire, 415 Volts outdoor type factory fabricated free floor standing type, including PCC foundation as per requirementof size(Minimum) , dust, rain and vermin proof cubical type, LT panel board fabricated from angle iron frameof size 50 x 50 X 6 mm with3.15mm thick CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint grey shade (RAL-7032) fully compartmentalized design with 04 Nos of bus bars each made of high conductivity 99.9% pure copper of ETP grade suitable for 300 Amps pre-wired with suitable size of copper cable/insulated copper strip including suitable Aluminum earth strips conforming to IS and all as specified with supply and fixing the following :- Incomming :- (i)MCCB four pole, 250 Amps, 36 KA, 415 volts adjustable thermal magnetic release type- 01 No (Incoming) (ii) Digital Ammeter 0-400 Amp 96 x 96mm with inbuilt selector switch and three current transformer of suitable ratio and capacity of make – AE/ENERCON/Conzerv - 01 No (iii) Digital Voltmeter 0-500 volts96 x 96mm with inbuiltselector switch of make – AE/ENERCON/Conzerv. - 01 No (iv) Three indication lamps for three phases. (v) Bus bar chamber having insulated copper bus bar (colour coded) each suitable for 300 Amps for three phases and neutral. Outgoing :- (i)MCCB four pole , 200 Amps, 36 KA, 415 volts adjustable thermal magnetic release type- 01 No (ii)MCCB four pole , 100 Amps, 36 KA, 415 volts adjustable thermal magnetic release type - 04 Nos (iii)MCCB four pole , 63 Amps, 16 KA, 415 volts adjustable thermal magnetic release type - 01 No
55Supply, installation, Testing and Commissioningin repairs of three Phase four wire, 415 Volts indoor type factory fabricated free floor standing type, including PCC foundation as per requirementof size(Minimum) , dust, rain and vermin proof cubical type, LT panel board fabricated from angle iron frameof size 50 x 50 X 6 mm with2.00mm thick CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint grey shade (RAL-7032) fully compartmentalized design with 04 Nos of bus bars each made of high conductivity 99.9% pure copper of ETP grade suitable for 300 Amps pre-wired with suitable size of copper cable/insulated copper strip including suitable Aluminum earth strips conforming to IS and all as specified with supply and fixing the following :- Incomming :- (i)MCCB four pole , 200 Amps, 36 KA, 415 volts adjustable thermal magnetic release type - 01 No (Incoming) Make : L&T (ii) Digital Ammeter 0-400 Amp 96 x 96mm with inbuilt selector switch and three current transformer of suitable ratio and capacity of make – AE/ENERCON/Conzerv - 05 Nos (Separately Digitalammeter for incoming and outgoing MCCB) (iii) Digital Voltmeter 0-500 volts96 x 96mm with inbuiltselector switch of make – AE/ENERCON/Conzerv. - 01 No (iv) Three indication lamps for three phases. (v) Bus bar chamber having insulated copper bus bar (color coded) each suitable for 300 Amps for three phases and neutral. Outgoing :- (i)MCCB four pole , 100 Amps, 36 KA, 415 volts adjustable thermal magnetic release type - 02 Nos (Outgoing)Make : L&T (ii) MCCB four pole, 63 Amps, 16 KA, 415 volts adjustable thermal magnetic release type - 01 Nos (Outgoing) (iii)Fully Automatic Star Delta Starter alongwth Three Phase Preventer suitable for25 HP Centrifugal pump & motor - 02 Nos (iv)On load change over 200 Amps, 415 Volt - 01 No
56Supply, installation, Testing and Commissioningin repairs of three Phase four wire, 415 Volts outdoor type factory fabricated free floor standing type, including PCC foundation as per requirementof size(Minimum) , dust, rain and vermin proof cubical type, LT panel board fabricated from angle iron frameof size 50 x 50 X 6 mm with3.15mm thick CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint grey shade (RAL-7032) fully compartmentalized design with 04 Nos of bus bars each made of high conductivity 99.9% pure copper of ETP grade suitable for 300 Amps pre-wired with suitable size of copper cable/insulated copper strip including suitable Aluminum earth strips conforming to IS and all as specified with supply and fixing the following :- Incomming :- (i)MCCB four pole, 200 Amps, 36 KA, 415 volts adjustable thermal magnetic release type- 01 No (Incoming) Make : L&T (ii) Digital Ammeter 0-400 Amp 96 x 96mm with inbuilt selector switch and three current transformer of suitable ratio and capacity of make – AE/ENERCON/Conzerv - 01 No (iii) Digital Voltmeter 0-500 volts96 x 96mm with inbuiltselector switch of make – AE/ENERCON/Conzerv. - 01 No (iv) Three indication lamps for three phases. (v) Bus bar chamber having insulated copper bus bar (color coded) each suitable for 300 Amps for three phases and neutral. Outgoing :- (i)MCCB four pole , 100 Amps, 36 KA, 415 volts adjustable thermal magnetic release type - 04 Nos (ii)MCCB four pole , 63 Amps, 16 KA, 415 volts adjustable thermal magnetic release type - 02 Nos
57M & L for installation ofOut Door Feeder piller box three phase four wire, 415 Volts fabricated free floor standing type, including PCC foundation as per requirement of size ( Minimum), dust, rain and verminproof cubical type LT Panel board on angle iron frame of size 35x35x6mm with 2 mm thick CRCA sheet with anticorrosive coating synthetic enamelsprey Grey paintwith fully compartmentalized designBus bar with 04 Nos of aluminium strips fixed on insulators & one Nos 100 Amp, 415 Volts, 16 KA,4 poles complete all as specified and as directed.
58M & L for carrying out servicing and repairs to Ring Main Unit (RMU) functional on 11000 Volts grade electric supply installed in Main Receiving Station (MRS) and pump house No. 2/ Sub station No. 2 at RTS & Depot Hempur after takingproper electric shut down & disconnectingand checking&includingreplacement of unserviceablespares of mechanical system such as bushes (Moving & fixed parts) of each 01 Nosincomer & 03 Nosout going, doing any Lathe & Machinigworketc, setting andtesting & making functional complete with one year duration guarntee for proper functioning.
59M & L for carrying out servicingand repairs totripping systemin ACB after takingproper electric shut down & disconnectingACBchecking and including replacement of unserviceable Battrey- 02 Nos&Battery charger for making the system proper functional complete with one year guarntee.
60M&L for preparation of existing painted surfaces of LT Panel Board indoor/outdoor type, area not exceeding 09 sq.m each and installed at various locations at RTS & Depotarea by scrapping with wire brushes etc., applying one spray coat of synthetic enamel paint of existing tint on external surfaces of panels including carrying out minor repairs to panel boards like welding of hinges, supports, re-writing the panel details and renewal of danger boards etc complete all as specified and as directed.
61M&L for Repairs & servicing to LT ACBs of any capacity (400 A to 1600 A) of any make by removing out the breaker from the respective panels after taking proper electric shut down & disconnecting the breaker, checking it thoroughly for the defects & tripping system of the ACB and rectifing them, lubrication of moving parts, overhauling of the ACB, replacement of wornout minor spares like springs, washers, levers, nuts & bolts etcreassembling, re-installation, testing & commissioning of ACB complete all as directed. [Note: Spare parts require replacement shall be measured as "Supply only"] Note :(i) Cost of lubricants, cleaning agents, testing tools and minor spares shall be deemed to be including in quoted rates
62Supply only Moving Arcing contacts and adjust the contact pressureof LT ACB including rectification of overheating and loose contact of any make any capacity (400 Amps to 1600 Amps) complete all as specified and as directed.
63Supply onlyclosing coilincluding rectification of manual and auto tripping arrangement of LT ACB of Exisiting make any capacity as per site requirement (400 Amps to 1600 Amps) complete all as specifed and as directed.
64Supply only shunt release of LT ACB of Existing make and capacity as per site requirement (400 Amps to 1600 Amps) complete all as specifed and as directed.
65Supply only auxillary contact 4NO+4NC suitable for LT ACB of Existing make and capacityas per site requirement (400 Amps to 1600 Amps) complete all as specifed and as directed.
66Material and labour for repairs andservicing to APPFC Panel for Trouble Free Operation including Control Wiring, testing etc, complete as directed by the Engr-in-Charge. [Note: Spare partsrequire replacement shall be measured as "Supply only"]
67Supply onlyLT Power capacitor, MPP, heavy duty, box type(Resin filled), 50 Hz, 440 volts of capacity 10 KVAR as per existingsize including taking down of existing unserviceable Capacitor complete as directed.
68Supply onlyLT Power capacitor, MPP, heavy duty, Cylindrical type, 50 Hz, 440 volts of capacity 5 KVAR as per existingsize including taking down of existing unserviceable Capacitor complete as directed.
69Supply onlyLT Power capacitor, MPP, heavy duty, Cylindrical type, 50 Hz, 440 volts of capacity 10 KVAR as per existingsize including taking down of existing unserviceable Capacitor complete as directed.
70Supply only Capacitor Duty Contactors type MO C5, includingFront mounting Auxiliary Contact Block 2 NO + 2 NC, 50 Hz, 415 Voltsof Rating Capacity5 KVAR as per existing sizeincluding taking down ofunserviceable Contactors,complete as directed.
71Supply only Capacitor Duty Contactors type MO C10, includingFront mounting Auxiliary Contact Block 2 NO + 2 NC, 50 Hz, 415 Voltsof Rating Capacity10 KVAR as per existing sizeincluding taking down ofunserviceable Contactors, complete as directed.
72Supply only automatic power factor controller RM-12 for measuring A.V.PF. Cos phi, W,V Ar,VA etc.including taking down of unserviceable automatic power factor controller RM complete as directed.
73Supply and fixing Push on Bottontype (Green Colour)and Push offBotton type (Red Colour)as per existing size, including taking down ofexisting unserviceable Push Botton, complete as directed.
74Taking down unserviceable indication lamp and supply, fix and testing indication lamp (LED type) with showing red, yellow and green in colour of 22.5mm dia monitor on LT panel board suitable for 240V AC supply all as specified and directed. Make :- L&T / Binay or equivalent as approved by GE
75Supply and fixDigitalelectronic type Voltmeter (0-500) Volts with in built selector switch and CT coil of existing size including taking down of existing unserviceable digital voltmeter, complete all as directed. Make : L&T, Conzerv or equivalent as approved by GE
76Supply and fixDigital electronic typeAmmeters(0-600A /1000A / 1200A), with in built selector switch including taking down of existing unserviceable digital ammeters,complete all as directed. Make : L&T, Conzerv or equivalent as approved by GE
77Taking down existing unserviceable Sreet lights / Flood lights / post top lightfittingscomplete and removing the items from site to store for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces to match with the existing surfaces of walls, ceiling etccomplete all as specified and directed all as specified and as directed.
78Supply and fixing in repairsLED 45 watt, decorative indirect post top, for garden landscape lighting with IP65 protection, resistant to impact and corrosion anti glare and uniform distribution and necessary modification of existing GI pole complete all as specified and as directed. Make : Crompton Cat No LPTOI-45-CDL or equivalent cat part in Havells / Bajaj / Philips
79Supply andfixingin repairsLED street light 45 Watt, 220V 50Hzmade up pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP65 protection and provision of bracket for fixing of street light fittings bend to shape, made out of bracketsuitable size GI pipe light grade upto 1.50m long fixed including MS clamps of size 40 x 4 mm, bolt, nuts & washer to fix with LT pole/Wall with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed. Make: CGCat No. LSTS-45-CDL-Mor equivalent in Bajaj/Philips/wipro
80Supply andfixingin repairsLED street light 60 Watt, 220V 50Hzmade up pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses withIP65 protection and provision of bracket for fixing of street light fittings bend to shape, made out of bracketsuitable size GI pipe light grade upto 1.50m long fixed including MS clamps of size 40 x 4 mm, bolt, nuts & washer to fix with LT pole/Wall with two coats of aluminium paint over a coat of red oxide primercomplete all as specified and as directed. Make: CGCat No. LSTS-45-CDL-Mor equivalent in Bajaj/Philips/wipro
81Supply andfixingin repairsLED street light 72 Watt, 220V 50Hzmade up pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses withIP65 protection and provision of bracket for fixing of street light fittings bend to shape, made out of bracketsuitable size GI pipe light grade upto 1.50m long fixed including MS clamps of size 40 x 4 mm, bolt, nuts & washer to fix with LT pole/Wall with two coats of aluminium paint over a coat of red oxide primercomplete all as specified and as directed. Make: CGCat No. LSTS-45-CDL-Mor equivalent in Bajaj/Philips/wipro
82Supply and fixing in repairsLED Floodlight120 Watt, 220V 50Hz made up pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses withIP66 protection along with mounting bracketfixing for LT pole all as specified and directed. Make: LFLN-120-CDL/60-M of Cromptonor equivalent in Wipro / Philips/Bajaj
83Supply and fixing in repairsLED Floodlight135 Watt, 220V 50Hz made up pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses withIP66 protection along with mounting bracketfixing for LT poleincluding necessary arrangment ofcable from floodlight to pole andall as specified and directed. Make: LFLN-135-CDL/60-M of Cromptonor equivalent in Wipro / Philips/Bajaj
84Supply and fixing in unique modular LED Floodlight250 Watt, 220V 50Hz made up pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses withIP66 protection along with mounting bracketfixing for LT pole/wall/gateincluding necessary arrangment ofcable from floodlight to pole/wall/gate andremoving the old defective light fitting complete ,all as specified and directed. Make: LFLPI-250-CDL/60-M of Cromptonor equivalent in Wipro / Philips/Bajaj
85Repairs/replacement of solar street light by dismantling panel, battery, PVC battery box, PVC wire LED light etc complete all as specified and directed.
86Supply only for PVC Battery box complete all as specified and directed-
87Supply only for solar LED light 12 Watt completeall as specified and directed
88Supply only for solar panel 50 watt completeall as specified and directed.
89Supply only for solar charger controller panel completeall as specified and directed.
90Supply only for battery 12 volt 40 AH fully completeall as specified and directed. Make: Exide/ SF/ Amaron
91Supply and fixingin repairsLED out door divices for street light 45/60/72 Watt, 220V 50Hz completeall as specified and directed.
92M&L for carrying out general servicing and repairs to Engine of DG set of the following capacity installed at varouse pump house at RTC & Depot Hempur including servicing of water pump, replacement of unserviceable spares, carrying out "B" Check as per manufacturer"s recommendations including replacement of oil filters, fuel/diesel filters with "O" rings, Turbo fileter, super bypass filter and Engine Oil and toping up of coolant up to required level complete all as specified and as directted by Engr-in-Charge. Notes :- (i) Supply only Engine Oil and coolant shall be measured and paid separetely. (ii) Rate quoted is inclusive of Oil filters, diesel filters with O rings, hose pipe and diesel pipe with clamps and turbo filter.. (iii) All the spares require replacement during servicing shall be measured and paid separately as "Supply only" (iv) Servicing of Radiator & self starter shall be measured and paid separately
93(a) 63 KVA DG set
94(b )40 KVA DG Set
95(c) 30 KVA DG Set
96(d) 25 KVA DG Set
97Supply only Air cleaner / filter of existing size suitable up to 63 KVA DG Set completeall as specified and directed.
98Supply only Engine oil15W-40W or as per manufacturer"s recommendation completeall as specified and directed.
99Supply only Radiator Coolant completeall as specified and directed.
100M&L for Cleaning and servicing of radiator assembly including cooler of the capacity DG Set upto 63 KVA by circulating de-scaling solution including repairs and replacement of worn out rubber hoses with clamps, mounting boots and bolts, recrification of leakages by welding/ brazing etc. completeall as specified and directed.
101M&L for supply and fixing against repairs Automatic Voltage Regulator (AVR) suitable for uptp 63 KVA, connecting with panel circuit, starting and testing on load all as specified and directed.
102Supply and replacement lead acid battery 12 V, 150 Ah complete (Initially charged) and connected to DG sets complete all as directed [Make: Exide/ SF/ Amaron]
103M&L for Junction boxes with PVC water tight encloser, ready made type, aluminium bus bar 25x3 mm, 200mm long fixed on post insulators, nut & bolts, MS Camps including 2.5 sqmm cable for street light connection completeall as specified and directed.
104S&F in repairssheet metal enclousers (DBS) when MCBs to be used 4 way, 240 Volts double door single pole & neutral with 200 Amps rated bus bar completeall as specified and directed.
105S&F MCB single phase and neutral 16A-32A,230V10KA. B" curve type complete all as specified and directed.
106S&F MCBSP 6A-32A, 230V. 10KA. B" curve type complete all as specified and directed.
107Supply only 1.5 sq. mm (nominal area) single core multi stranded FRLS copper conductor PVC insulated unsheathed cable 1100 volts grade ISI Marked completeall as specified and directed.
108Supply only 4.0 sq. mm (nominal area) single core multi stranded FRLS copper conductor PVC insulated unsheathed cable 1100 volts grade ISI marked completeall as specified and directed.
109Supply only 10.0 sq. mm (nominal area) single core multi stranded FRLS copper conductor PVC insulated unsheathed cable 1100 volts grade ISI marked completeall as specified and directed.
110Supply only heavy dutycable with PVC isulated, inner sheathing of PVC tape armoured with GI steel wire in service connection etc complete of size 10.0 sq.mm (nominal area)two core multi strandedwith aluminium conductormulti stranded 1100 volts grade completeall as specified and directed.
111M&L in repairs Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6 mm thick buried directly inground (Earth pit not less than 2.25 Mtr deep below normal ground level ) with topedge of the plate not less than 1.5 Mtr belownormal ground level connecting with GI earthstrip 32x6 mm dia by means ofbolt nut check nuts and washersof galvanizediron and provision of GI tubing light gra de (ISI marked) of 40 mm bore for protection of earthstrip of 32x6 mm includingPCC with 1:2:4 type B1 using 20mm graded crushed stone aggregate CI frame and cover of angle iron 40x40x6mm andhandle 6mm dia MS bar made toshape GI light grade20mm bore pipe for wateringperforatedatbottom 1.75 metre longplaced on top edge of earth plate, charcoal and common salt filling, test point made out of Bronze/Gun metalwith fixing arrangment , funnel, wire mesh andearth work insoft/loose soil, returning filling in and removal of surplus soil to adistance not exceeding 50 Metres , all asper electrical plate No 3 of SSR 2009 Pt -I to earth test point all as specified orindicatedincludingtesting on completion. NOTE :- The quoted rate of earthing shall be deemed to included cost of 7.5 m long galvanised wire 32x6 mm dia and protection pipe of 40 mm bore medium grade(ISI marked) any veriation in length shall be adjusted through deviation order based on SSR rates adjusted with quoted rates.
112All as per Srl item No. 97 here in before but4.0 mm GI wire as earthing lead with 15 mm dia light grade
113Supply only Rechargeable Torch LED 90W Flash light extra long Beam, 1.5 KMRange, 7-14 Hours battery back up, water proof with aluminium body, super Bright LED lightcompleteall as specified and directed. Make-Havells/Docoss/Philips
114Supply only Aluminium lugs tubular with suitable hole, heavy duty for cable of size 150 sqmm completeall as specified and directed.
115Supply only Aluminium lugs tubular with suitable hole, heavy duty for cable of size 240 sqmm completeall as specified and directed.
116Supply only Aluminium lugs tubular with suitable hole, heavy duty for cable of size 300 sqmm completeall as specified and directed.
117Supply only Aluminium lugs tubular with suitable hole, heavy duty for cable of size 400 sqmm completeall as specified and directed.
118Supply only Nut bolts with washers complete off sizes completeall as specified and directed.
119Supply only Ampare tapehigh intensity reflective, yellow, 50mm width, 50 mtr in length completeall as specified and directed.
120Supply onlyHTtapehigh intensity reflective, Black, 50mm width, 50 mtr in length completeall as specified and directed.
121Supply onlyCotton tape completeall as specified and directed.
122Supply only synthetic Rubber insulated mat 3mm thick for Voltage upto 33 KV of size 2 M x1 M completeall as specified and directed.
123Supply only Rubber insulated Hand Gloves for working on Voltage 33 KV tested.
124Supply only Hook Stick 5-18 feet long in three pices folding type, Fiber Glass for working on 11000 Volts grade power supply completeall as specified and directed.
125Supply only Tinedcopper Fuse wire 5Amp to 20 Amp completeall as specified and directed.
126Supply onyPVCLT over hèad electric supply line separator complete as specified length completeall as specified and directed.
127Supply onyMS Nut, bolts with washers off sizes complete as specified.
Disclaimer :