}

Tender For Repair Replacement Of Unsv Lt Ug Cable And Distribution System Capacitor Banks Apfc Panel Lt Control Panel And Other Allied Works In Ph I Under Ge Narangi, narangi-Assam

Military Engineer Services-MES has published Tender For Repair Replacement Of Unsv Lt Ug Cable And Distribution System Capacitor Banks Apfc Panel Lt Control Panel And Other Allied Works In Ph I Under Ge Narangi. Submission Date for this Tender is 14-11-2022. Control Panel Tenders in narangi Assam. Bidders can get complete Tender details and download the document.




Tender Notice

34632698
Tender For Repair Replacement Of Unsv Lt Ug Cable And Distribution System Capacitor Banks Apfc Panel Lt Control Panel And Other Allied Works In Ph I Under Ge Narangi
Open Tender
Indian
Assam
narangi
14-11-2022

Tender Details

Repair Replacement Of Unsv Lt Ug Cable And Distribution System Capacitor Banks Apfc Panel Lt Control Panel And Other Allied Works In Ph I Under Ge Narangi

Key Value

Document Fees
INR 500 /-
EMD
INR 66000.0 /-
Tender Value
INR 33 Lakhs /-

BOQ Items

NAME OF WORK : REPAIR /REPLACEMENT OF UNSV LT UG CABLE AND DISTRIBUTION SYSTEM , CAPACITOR BANKS, APFC PANEL, LT CONTROL PANEL, AND OTHER ALLIED WORKS IN PH-IUNDER GE NARANGI.
Sl. No. Item Description
1Excavation in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth for laying of cable , etc. n.exc 10 Sqm on planand getting out in soft/loose soil complete all as specified and as directed.
2Returning filling in including spreading, levelling watering and well ramming in layers not exc 25 cm thickin soft /loose soil complete all as specified and as directed.
3Removing surplus soil to a distance not exc 50m and depositing at level not exc 1.5m above the starting point complete all as specified and as directed.
4Taking out old unserviceable UG cable of any size/ type from trenches / wall / roof etc. for necessary repair/ replacement / re-laying works complete all as specified and as directed.
5M&L for relayingold serviceable UG cable of any size/ typealongwith brick protection, sand cushioning etc as obtained from taking up/down old cable here in before intrenches/ wall/ roof etc. after necessary repair/ rerouting if directedcomplete all as specified and as directed.
6M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 185 sqmm 3.5 core laid in trenches /floor or fixed on wall /poleincluding brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
7M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 120 sqmm 3.5 core laid in trenches /floor or fixed on wall /poleincluding brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
8M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 95 sqmm 3.5 core laid in trenches /floor or fixed on wall /poleincluding brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
9M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 50 sqmm 3.5 core laid in trenches /floor or fixed on wall /poleincluding brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
10M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 25 sqmm 3.5 core laid in trenches /floor or fixed on wall /poleincluding brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
11M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with stranded aluminium conductor, 1100 Volts grade of size 16 sqmm 4 core laid in trenches /floor or fixed on wall /poleincluding brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
12M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with solid aluminium conductor, 1100 Volts grade of size 10 sqmm 2 core laid in trenches /floor or fixed on wall /poleincluding brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
13M & L for XLPE insulated, PVC sheathed, armoured, heavy duty electric under ground cable, with solid aluminium conductor, 1100 Volts grade of size 6 sqmm 2 core laid in trenches /floor or fixed on wall /poleincluding brass compression cable glands, terminal lugs etc, complete all as specified and as directed.
14Supply and spreading clean dry river sand in cable trenches as in cable cushioning complete all as specified and as directed. (Note: Punnedthickness shall be measured and paid)
15M&L for Sub class ‘B’ old size well burnt brick laid flat in trenches over the cable forprotection of LT cable complete all as specified and as directed.
16M& L for Manual boring under roads / hard standingby required T&P without disturbing the top surface of the road for passingthe cable in GI Pipe of 40 mm to 80mm dia complete all as specified and as directed.
17M&L for GI pipe light grade 40mm bore with all fittings laid in trenches or in floors,including taking up/ down old pipecomplete all as speciffied and as directed
18M&L for GI pipe light grade 80mm bore with all fittings laid in trenches or in floors,including taking up/ down old pipecomplete all as speciffied and as directed
19S&F in repair cable jointing kit for LT (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable foraluminium Conductor cableofsize 25-50 Sqmm 3.5 core complete all as specified and as directed.
20S&F in repair cable jointing kit for LT (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable foraluminium Conductor cable of size 70-120 Sqmm 3.5 core complete all as specified and as directed.
21S&F in repair cable jointing kit for LT (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for aluminium Conductor cable of size 150-185 Sqmm 3.5 core complete all as specified and as directed.
22S&F in repair cable jointing kit for LT (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable foraluminium Conductor cableofsize 240-300 Sqmm 3.5 core complete all as specified and as directed.
23Demolition of cement concreteof any descriptionand in any position not otherwise specifically provided forcomplete all as specified and directed.
24M & L for preparation of old painted surfaces of LT steel tubular pole 9.00 m long, cross arms, bracings, supports, clamps, back plate with nut bolts washersand providing one coat of aluminium paint including numbering and making strips in circular shape of diameter 150 mm black colour letter of hight 50 mm complete all as directed by Engr in Chargeupto1.5 mtr above ground level with alternate layer of white and black paintcomplete all as specified & as directed.
25S &F street light fitting of60 Watt LED made ofpressure die cast aluminium housing with toughned glass and LEDs with secondary optics and IP 66 protectionand lens embedded PC Cover having top opening seperate driver compartment,should have luminaire efficacy =110 lumens/watt,CRI>70 ,PF > 0.95,CCT=5500,IP66,impact resistance IK 07 ,inbuiltprotection against lightning , over voltage , short circuit and surge/spike protection device upto10 kV complete also tested for 440 Volt for 8 hour Phase to phase without any damageincluding taking down old unserviceable light fittings complete allas specified and as directed. ( NOTE :(i) PVC insulated PVC sheathed, multistranded aluminium or copper conductor cable of size 1.5 sqmmX 3 core from light fitting to Street light feeder (max 2.0 mtr ) deemed to be included in quoted rate. (ii) Manufacturer’s test certificate of LED light fitting in respect to LM 79 and LM 80 shall be submitted by the contractor.)
26S &F street light fitting o f 45 Watt LED made ofpressure die cast aluminium housing with toughned glass and LEDs with secondary optics and IP 66 protectionand lens embedded PC Cover having top opening seperate driver compartment,should have luminaire efficacy =110 lumens/watt,CRI>70 ,PF > 0.95,CCT=5500,IP66,impact resistance IK 07 ,inbuiltprotection against lightning , over voltage , short circuit and surge/spike protection device upto10 kV complete also tested for 440 Volt for 8 hour Phase to phase without any damageincluding taking down old unserviceable light fittings complete allas specified and as directed. ( NOTE :(i) PVC insulated PVC sheathed, multistranded aluminium or copper conductor cable of size 1.5 sqmmX 3 core from light fitting to Street light feeder (max 2.0 mtr ) deemed to be included in quoted rate. (ii) Manufacturer’s test certificate of LED light fitting in respect to LM 79 and LM 80 shall be submitted by the contractor.)
27S &F in repair Post Top LED light of capacity 40 Watt, housing made of aluminium alloy with polycarbonate diffuser having anti-aging spray treatment complete allas specified and as directed.
28S&F in repair MCCB with Thermal - magnetic release of 80-100 Amps, 4 Pole, 415V, 25 kA, Ics=100%Icuwith adjustable over load settingand adjustable short circuit setting including all accessoriescomplete all as specified and as directed.
29S&F in repair MCCB with Thermal - magnetic release of 125-160 Amps, 4 Pole, 415V, 25 kA, Ics=100%Icuwith adjustable over load settingand adjustable short circuit setting including all accessoriescomplete all as specified and as directed.
30S&F in repair MCCB with Thermal - magnetic release of 200-250 Amps, 4 Pole, 415V, 36 kA, Ics=100%Icuwith adjustable over load settingand adjustable short circuit setting including all accessories complete all as specified and as directed.
31S&F in repair MCCB with Thermal - magnetic release of 320-400 Amps, 4 Pole, 415V,50 kA, Ics=100%Icuwith adjustable over load settingand adjustable short circuit setting including all accessories complete all as specified and as directed.
32S&F in repair MCCB with Thermal - magnetic release of 500-630 Amps, 4 Pole, 415V,70 kA, Ics=100%Icuwith adjustable over load settingand adjustable short circuit setting including all accessoriescomplete all as specified and as directed.
33S&F in repair SS enclosure for MCCB of rating 250 Amps in built neutral link for TPN system 1 IK08 and IP 30 protection having louvers for better heat dissipation suitable to accommodate upto 185 Sqmm 3.5 core Aluminium armoured cable including taking down and refixing serviceable/ new MCCB in enclodsure and conectingexisting IC/OG cable with proper dimension lugs complete all as specified and as directed. ( Note : The cost of New MCCB if provided under the item shall be measured and paid seperately).
34Taking down old unsv / corrodedLT feeder pillar box / DB Box / Busbar Chamber of any sizes or types and disconnection of all electrical connections complete for replacement with new one, complete all as specified and as directed.
35Supply, installation, testing and commissioning of factory made powder coated (CPRI approved) outdoor type, dust & vermin proof feeder pillar box made out of 3.15mm CRCA steel sheet of suitable size and angle iron 40 mm x 40mm x 6 mm ,factory made duly fixed on the ground by PCC foundation (1:2:4 Type B-1) of size700mm x300mm x600mm on the adjacent pairs of leg & net cementing the same. The feeder pillar box shall beduly painted with two coats of epoxy based powder quoted paint over a coat of red oxide primer (internally &externally) on thesurface all as specified and directed by Engr-in-Charge.The feeder pillar box is cubicle shaped, roof canopy type, with special type of heavy duty industrial door hingesand totally enclosed dust proof and vermin prooffront and backopening with locking arrangements. The box shall have provision/accommodation of the following electrical items:- INCOMING: (i) Aluminium bus bar 4 strips (covered with colour coded insulated PVC sleeves)ofrating 1.5 times currrent carrying capacity of incoming switch gear or not less than 200 Amps whichever is higher of suitable length including connection etc complete – 01 Set(ii) Indicator lamp for RYB phase(iii) Moulded case circuit breaker 80-100 Amps 415 Volts, Thermal Magnetic release with adjustable over load setting and adjustble short circuit setting,4 pole, ,Ics=100% Icu,25 kA breaking capacity.= 01 Nos.(iv) VAF+PF multifunction meter CI flush mounting 96x96mm CT/PT site programmable including CTs.
36OUTGOING: (i) MCB Four pole of capacity 40 Amps, C curve of breaking capasity 10 Ka- 04 Nos(ii)MCB DP of capacity 32 Amps, C curve of breaking capasity 10 Ka- 05 Nos. Note : All cables in the feeder pillar box shall be properly thimbled as directed and specified.
37Supply, installation, testing and commissioning of factory made powder coated (CPRI approved) outdoor type, dust & vermin proof feeder pillar box made out of 3.15mm CRCA steel sheet of suitable size and angle iron 40 mm x 40mm x 6 mm ,factory made duly fixed on the ground by PCC foundation (1:2:4 Type B-1) of size700mm x300mm x600mm on the adjacent pairs of leg & net cementing the same. The feeder pillar box shall be duly painted with two coats of epoxy based powder quoted paint over a coat of red oxide primer (internally &externally) on thesurface all as specified and directed by Engr-in-Charge.The feeder pillar box is cubicle shaped, roof canopy type, with special type of heavy duty industrial door hingesand totally enclosed dust proof and vermin prooffront and backopening with locking arrangements. The box shall have provision/accommodation of the following electrical items:- INCOMING: (i) Aluminium bus bar 4 strips (covered with colour coded insulated PVC sleeves)ofrating 1.5 times currrent carrying capacity of incoming switch gear or not less than 200 Amps whichever is higher of suitable length including connection etc complete – 01 Set(ii) Indicator lamp for RYB phase(iii) Moulded case circuit breaker 80-100 Amps 415 Volts, Thermal Magnetic release with adjustable over load setting and adjustble short circuit setting,4 pole, ,Ics=100% Icu,25 kA breaking capacity.= 01 Nos.(iv) VAF+PF multifunction meter CI flush mounting 96x96mm CT/PT site programmable including CTs.Note: In bus bar there must be provision of connecting of minimum 4 outgoing cable
38OUTGOING: (i) Moulded case circuit circuit breaker 63-80 Amps 415 Volts, thermal Magnetic release with adjustable over load settingand adjustable short circuit setting, four pole, Ics=100% Icu , 25 KA braking capacity= 01 No.(ii) MCB Four pole of capacity 32 Amps, C curve of breaking capasity 10 Ka- 02 Nos(iii)Astronomical timer (Astro mini) 110-240 VAC, 1 phase, Cat part No. T2DDT7 of make L&T or equivalent in Havells/C&S. (iv) 3 Pole contactor of current rating AC1 50 Amps, with inbuilt surge suppressor . Make : L&T Cat part No. CS94568 or equivalent in Havells/C&S (v) 2A, SP, 10 KA MCB- 01 No. ( For timer protection)Note : All cables in the feeder pillar box shall be properly thimbled as directed and specified.
39Repairs/maintenance ofLT Panel board/box upto 100 KVAR capacity including disconnecting all incoming and outgoing connection after taking necessary shut down, cleaning the carbon/rust from bus-bar, re-thimbling with new lugs/thimble of existing size,removing old burn out wiring and re-wiring with new cable of exising size, including replacement of unserviceable parts complete all as specified & directed :- Note :- (i) New spares shall be measured and paid separately under relevants items as supply only. (ii) Cost of unsheathed multistranded copper conductorof size upto 2.5 Sqmm for internal wiring like connection of CTs deemed to be included in quoted rate.(iii) All calibration of meters and APFC controller shall be done by the contractor after fixing in position. (iv) Suitable size of copper/aluminium cable lugs shall be provided by contractor for fixing/jointing the cable in bus bar etc.
40Supply only3 phase single function LED Voltmeter flush mounting 96X96 mm of input voltage measurement range 50-520 VAC (P-P), 5 A, accuracy class 1 for LT panel board complete all as specified and directed. Make : L&T Cat Part No. WL132010 OOOO or equivalent in Conserve/ Siemens
41Supply only3 phase single function LED Ammeter flush mounting 96X96 mm , CT secondary site selectable 1A/5A, accuracy class 1 for LT panel board complete all as specified and directed. Make : L&T Cat Part No. WL131010 OOOO or equivalent in Conserve/ Siemens
42Supply only3 phase VAF+PF digital meter flush mounting 96X96mm of input voltage measurement range 50-520 VAC (P-P)5A, , accuracy class 1 for LT panel board complete all as specified and directed. Make : L&T Cat Part No.WL411021 OOOO or equivalent in Conserve/ Siemens
43Supply onlyindoor type insulated ring type low tension current transformer of ratio 500/5A, accuracy class 1 for LT panel board complete all as specified and directed.
44Supply onlyLED indicator lamp to be mounted on LT panel for R-Y-B phase ( Of colour Red, Yellow, Green) operates on 240V AC for fixing in the existing place in LT panel board complete all as specified and directed. Make : L&T or equivalent in Coserve/AE .
45Supply only 25 sqmm single core FRLS insulated unsheathed multistranded copper conductor for voltage 1100 V , complete all as specified and as directed.
46Supply only 50 sqmm single core FRLS insulated unsheathed multistranded copper conductor for voltage 1100 V , complete all as specified and as directed.
47Repairs/maintenance ofAPFC LT Panel board/box upto 100 KVAR capacity including disconnecting all incoming and outgoing connection after taking necessary shut down, cleaning the carbon/rust from bus-bar, re-thimbling with new lugs/thimble of existing size,removing old burn out wiring and re-wiring with new cable of exising size, including replacement of unserviceable parts complete all as specified & directed :- Note :- (i) New spares shall be measured and paid separately under relevants items as supply only. (ii) Cost of unsheathed multistranded copper conductorof size upto 2.5 Sqmm for internal wiring like connection of CTs deemed to be included in quoted rate.(iii) All calibration of meters and APFC controller shall be done by the contractor after fixing in position. (iv) Suitable size of copper/aluminium cable lugs shall be provided by contractor for fixing/jointing the cable in bus bar etc.
48Supply only Switch disconnector-fuse unit of current rating 100 Amp having terminal shrouds on both sides including phase barrier open execution type suitable for DIN fuse-link(4P) complete all as specified as directed. Make : L&T Cat Part No. SK90496 or equivalent in Havells/C&S.
49Supply only digital 8 step APFC controller of size 96X96 for contractor switching, operating voltage 415V Volts complete all as specified and as directed.Make : L&T, Cat No CS90902OOOO or equivalent make of Schneider/ABB.
50Supply only Indoor tape insulated ring type low tension current transformers of ratio 100/5A accuracy class 1.0 for LT panel board, complet all as specified and directed by Engr-in-Charge.
51Supply only Indoor tape insulated ring type low tension current transformers of ratio 200/5A accuracy class 1.0 for LT panel board, complet all as specified and directed by Engr-in-Charge.
52Supply only 3 Phase, 415 V capacitor duty contactorwith built in surge suppressor and endcapsulated with damping resistor assembly suitable for 5 KVAR ratingcomplete all as specified and as directed. Make : L&T Cat Part No CS96127 or equilvalent in Havells/ABB.
53Supply only 3 Phase, 415 V capacitor duty contactorwith built in surge suppressor and endcapsulated with damping resistor assembly suitable for 10 KVAR ratingcomplete all as specified and as directed. Make : L&T Cat Part No CS96156 or equilvalent in Havells/ABB.
54Supply only 3 Phase, 415 V capacitor duty contactorwith built in surge suppressor and endcapsulated with damping resistor assembly suitable for 20 KVAR ratingcomplete all as specified and as directed. Make : L&T Cat Part No CS90021 or equilvalent in Havells/ABB.
55Supply only 3 Phase, 415 V power contactor of AC3 rating 25 Amp complete all as specified and as directed. Make : L&T Cat Part No CS94110 or equilvalent in Havells/ABB.
56Supply only 3 Phase, 415 V power contactor of AC3 rating 32 Amp complete all as specified and as directed. Make : L&T Cat Part No CS94111 or equilvalent in Havells/ABB.
57Supply only 3 Phase, 415 V power contactor of AC3 rating 40 Amp complete all as specified and as directed. Make : L&T Cat Part No CS94190 or equilvalent in Havells/ABB.
58Supply only coil for MNX 25-MNX 40 contactor 240 V AC complete all as specified and as directed. Make : L&T Cat Part No CS94105 or equilvalent in Havells/ABB.
59Supply onlyMNXcontactor contact kit complete all as specified and as directed. Make : L&T Cat Part No CS94147 or equilvalent in Havells/ABB.
60Supply only heavy duty cylindrical type capacitor of capacity 5 k VAR, suitable for operating on 440 Volts 3 Phase complete all as specified and as directed.
61Supply only heavy duty cylindrical type capacitor of capacity 10 k VAR, suitable for operating on 440 Volts 3 Phase complete all as specified and as directed.
62Supply only heavy duty cylindrical type capacitor of capacity 12.5 k VAR, suitable for operating on 440 Volts 3 Phase complete all as specified and as directed. Make : L&T or equivalent in Havells/ABB.
63Supply only heavy duty cylindrical type gas filled capacitor of capacity 20 k VAR, suitable for operating on 440 Volts 3 Phase complete all as specified and as directed.
64Supply only heavy duty cylindrical type capacitor of capacity 25 k VAR, suitable for operating on 440 Volts 3 Phase complete all as specified and as directed. Make : L&T or equivalent in Havells/ABB.
65M&L for Cross arms, bracings, supports, clamps, eye hook and back plates fabricated from structural steel sections including pole clamps, stay clamps, D clamps nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including painting with twocoats ofaluminiumpaintover a coat of red oxide primer including taking down the old unserviceable cross arms, clamps etccomplete all as specified and as directed.
66M&L for ACSR conductors (weasel type)for LT OH lines on poles including stringing, binding with aluminium wire 14 SWG or aluminium tape includingjumpers complete connecting of disconnected cable, service cable and street light connection including dismantling of unserviceable ACSR conductor of any size from any position complete all as specified and as directed.
67M & L for Prunning / trimming the branches of trees if any along overhead line, 3 m on all side below/ above/ sides of overhead line and removing the same upto a distance of 150m, each span not exceeding 45 m complete all as specified and as directed.
68M & L cutting grasses, shrubs/herbs surrounding LT poles, feeder pillar box installations by mechanical or manual T&P, removing the debris at a distance not exceeding 50m and depositing where directed complete all as specified and as directed.
69M & L for Stringing / stretching, including jointing in situ of each span not more than 45 m betweentwo electric poleshaving 4 Nos of ACSR conductors of any size including GI earth continuity wire, with/ withoutguarding wires onelectric poles of any size at different locations all as directed to the extent of permissible sag or tension by removing jumpers or bindings from insulators and making fresh binding with aluminium tapes after stringing complete all as specified and as directed. (Note :- One span measured as 4 Nos wire of LT over head line and 2 Nos of earth wire.)
70M & L for Stringing / stretching, including jointing in situ of each span not more than 45 m betweentwo electric poleshaving 2 Nos of ACSR conductors of any size including GI earth continuity wire, with/ withoutguarding wires onelectric poles of any size at different locations all as ordered to the extent of permissible sag or tension by removing jumpers or bindings from insulators and making fresh binding with aluminium tapes after stringing complete all as specified and as directed. (Note :- One span measured as 2 Nos wire of LT over head line and 1 Nos of earth wire.)
71M&L for cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in foundation fillingand mass concrete complete all as specified and as directed.
72M&L for cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in foundation fillingand mass concrete complete all as specified and as directed.
73M&L for PCC 1: 3 : 6 type C-1 using 20 mm graded stone aggregatefor coping to the new/ existingSteel Poles including necessary form work complete all as specified and as directed.
74M&L forerection and fixing of steel tubular swaged pole type 410 SP - 31 (9.00 metres long) confirming to IS- 2713 Part I to III 1980 with and including cast iron base plate, finial taper plug, nuts, bolts and washers etc. fixed in PCC foundationduly painted painted with two coats of Aluminium paint over a coat of red oxide primer including preparation of surface and including dismsntling of old pole of any size and description with foundation, PCC coping etc. complete all as specified and as directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail