Tender For Maintenance And Operations Of Electrical Repairs And Mccb, Contracts Cables Etc And Other Installation Along With Maint Misc Works At Af Stn Suryalanka
Tender Overview
Project Description
Maintenance And Operations Of Electrical Repairs And Mccb, Contracts Cables Etc And Other Installation Along with Maint Misc Works At Af Stn Suryalanka As Per Tender Documents
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 07-Nov-2022 | Corrigendum BOQ and Sch of Credit | BOQ | 21-Nov-2022 |
| 2 | 21-Nov-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 28-Nov-2022 |
BOQ
| Sl. No. | Item Description |
| 1 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat or circular stranded/solid of size 10 Sqmmincluding taking down old unsv service cablecomplete all as specified |
| 2 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat or circular stranded of size 16 Sqmm including taking down old unsv service cable complete all as specified |
| 3 | Supply and fix in repair PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 3 core 1.5 sqmm 1100 Volt, conforming to IS 694, multistranded with Rigid Heavy duty PVC Conduit of 20 mm dia with bends from Junction box to connector of Street light fitting complete all as specified and as directed. Make Polycab/ Finolex/ Havells/ Gloster/ Nicco |
| 4 | Supply and fixing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 4 core including necessary arrangement for fixing on wall, roof etc by using clamps, screws, porceilane insulators etc including taking down old unsv service cablecomplete all as specified and directed |
| 5 | Supply & fixing of cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 4 core including necessary arrangement for fixing on wall, roof etc by using clamps, screws, porceilane insulators etc including taking down old unsv service cablecomplete all as specified and directed |
| 6 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat or circular stranded/solid of size 6 Sqmmincluding taking down old unsv service cablecomplete all as specified |
| 7 | Excavation in trenches,in soft/loose soilnot exceeding 1.5 m deep and not exceeding 1.5 m in wide for laying of cable,RCC Poles/stays and struts etc and getting out including trimming sides and forming bottom surface all as specified and as directed. |
| 8 | Returning, filling-in, including spreading, watering and well ramming in layers notexceeding 25 cm thick each, in soft /loose soil complete all as specified. |
| 9 | M & L for sand cushioning to underground cable including punning down of sand in layer complete all as specified and directed. Note :- Punned down thickness shall be measured for payment |
| 10 | M&L for laying common burnt bricks, sub class \"B\", of size 230 x 115 x 75 mm in trenches for cable protection complete all as specified and as directed. |
| 11 | M&L Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting complete all as specified and directed |
| 12 | S&F in replacement Street light timer analog clock type 3 module with battery backup, programable for every 15 Min, and connected to existing power contact for controlling complete all as specified and as directed. |
| 13 | S&F in replacement of Power Contactor of 3 Phase, 40 Amps, 4 Pole, in existing Street light panel and connection with bus bar / cable with copper wire complete all as specified and as directed |
| 14 | Material & Labour for MCB TPN in repair/replacement of 63 Amp 415 V unserviceable existing MCB including taking down by removing burn out cable and fixing of new MCB and provn of connection by using suitable PVC copper cable not less than 1.5 Sqmm as existing complete all as specified and directed |
| 15 | Material & Labour for fixing of MCCB 415 V, 16 KA, 3 Pole 63 A including taking down old burn out MCCB and making necessary arrangement for fixing the new one like cutting, welding, thimble of suitable size, nuts & bolts etc complete required for fixing the new one all as specified and directed |
| 16 | Material & Labour for fixing of MCCB 415 V, 16 KA, 3 Pole 125 A including taking down old burn out MCCB and making necessary arrangement for fixing the new one like cutting, welding, thimble of suitable size, nuts & bolts etc complete required for fixing the new one all as specified and directed |
| 17 | Material & Labour for fixing of on load change over 415 V, 4 Pole 63 A including taking down old burn out Change over and making necessary arrangement for fixing the new one like cutting, welding, thimble of suitable size, nuts & bolts etc complete required for fixing the new one all as specified and directed |
| 18 | S&F in replacement of LT junction box outdoor, single door opening front side with aldrop sliding locking arrangement suitblesize made out of CRCA Sheet of 3.15 mm thick with powder coated painting frame made out of flat iron 45 x 45 x 6 mm and four numbers of 100 Amps aluminumbars duly insulated on insulators / suitable size Bakelite sheet fixed horizontally including making necessary drilling on bus bars for fixing of out going cable upto 95 Sqmm XLPE - 05 Nos with minimum gap as per IE standards and one No MCCB of capacity 63 A, 4 Pole, 415 V 25 KA complete ( free space between MCCB / busbar and other connection items should be provided,) including fixing arrangement on poles at the height upto 1.5 Mtrsby using suitable size of iron flat bracket, nuts & bolts, danger notice sticker, cable glands, internal wiring with FRLS copper wires of suitable size complete all as specified and directedNote :Before placing the order the contractor should submit the Drg for approval of AGE(I) |
| 19 | Dismantiling / taking down LED street light / security lights of any capacity & description from exising LT pole/octaganol street light pole of height 7.5 mtr and refixing the fittings in existing / another location after repair work or carrying to credit complete all as specified and as directed.Note for item No. 19 above:- (i)Replacement of defective parts accessories shall be measured and paid separately under relevant item of Sch \"A\" as supply and fix in repair.(ii)Transport and T & P i.e. Ladder/crane for replacement of light from PCC/Octagnol pole of height 7.5 mtr, spanners or any other equipment for repair of street light shall be provided by Contractor and cost for the same deemed to be included in respective item of Sch \"A\" |
| 20 | Supply & fix in repair LED Driver of 45 Watt of suitable make and model as per exisiting LED 45 Watt Street light fitting.Make: Havells/ Crompton / Bajaj |
| 21 | Supply & fix in repair LED Driver of 45 Watt of suitable make and model as per exisiting LED 45 Watt Street light fitting.Make: Havells/ Crompton / Bajaj |
| 22 | Supply and fixing LED street light fitting with and including individual high power 45 watt LED new generation energy saving and environmental friendly long life LED street light made up of pressure die cast alu with secondary optics, suitable for outdoor use IP 66, connected withconnecting cable complete all as specified and as directed |
| 23 | Supply and fixing LED street light fitting with and including individual high power 25 watt LED new generation energy saving and environmental friendly long life LED street light made up of pressure die cast alu with secondary optics, suitable for outdoor use IP 66, connected withconnecting cable complete all as specified and as directed |
| 24 | S&F in replacement of Flood light of any wattage and type with LED Flood light of 150 Watt Symetrical illumination, along with Driver assembly as per OEM Specifications, Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light and connecting up existing cable complete all as specified and as directed. Make: Havells, Model: JETAIRISFLS150WLED757PSYMLTG or its equivalent in Philips/ Wipro/ Crompton |
| 25 | S&F in replacement of existing Post light of any type and wattage with New generation, LED Post Top light of wattage 45 Watt, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source complete and connecting up with exisitng cable complete all as specified and as directed. |
| 26 | S&F in replacement of existing loop in-out junction box with non metalic PVC junction box suitable of size 350 x 250 x 150 with connector 4 way and including one MCB SP 6 A, 230V alongwith 2 Nos \"C\" Clamps and back clamp made up of 20x3 flat iron and fixing on pole with necessary nuts bolts, washers, 2 Nos cable glands of size not exc 4 core 25 sqmm, Cable lugs as required complete all as specified and as directed. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender