Tender For Repair / Maintenance To Water Rising Mains, Bore Wells And Repair / Replacement Of Security / Perimeter Lights And Connected Works At Damana Under Ge Jammu, jammu-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Repair / Maintenance To Water Rising Mains, Bore Wells And Repair / Replacement Of Security / Perimeter Lights And Connected Works At Damana Under Ge Jammu. Submission Date for this Tender is 03-12-2022. LED Light Tenders in jammu Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

34602080
Corrigendum : Tender For Repair / Maintenance To Water Rising Mains, Bore Wells And Repair / Replacement Of Security / Perimeter Lights And Connected Works At Damana Under Ge Jammu
Open Tender
Indian
Jammu And Kashmir
jammu
03-12-2022

Tender Details

Tender For Repair / Maintenance To Water Rising Mains, Bore Wells And Repair / Replacement Of Security / Perimeter Lights And Connected Works At Damana Under Ge Jammu

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 04-Nov-2022 Corrigendum02 Other 19-11-2022
2 04-Nov-2022 Corrigendum01 BOQ 19-11-2022
3 12-Nov-2022 Corrigendum03 Date 26-11-2022
4 26-Nov-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-12-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : Repair / maint to water rising mains, bore wells and repair / replacement of security / perimeter lights and connected works at Damana under GE Jammu.
Sl. No. Item Description
1Dismantling and removing and setting aside PCC pole / struts any type by breaking PCC foundation after disconnecting electrical connection including site clearance complete all as specified and directed by Engineer-in-Charge.
2Material and labour for steel swagged poles complete poles 9 metre long complete with cast iron base plate, finial taperplug, bolts, nuts and screws as specified type 410 SP-31 with one coat of red oxide primer and two coats of aluminium paint and including marking alternate 5 no"s black and white strip 30 cm height with two coats of synthetic enamel paint over a coat of primer including preparation of new surface complete all as specified and as directed.
3Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out in any type of soil for taking up or laying of cable / mild steel / cast iron / galvanised iron pipes complete all as specified and directed.
4Excavation in trenches not exceeding 1.5 metre wide but not exceeding 3.0 metre in depth and getting out in any type of soil for taking up or laying of cable complete all as specified and directed.
5Returning, filling in, including spreading, levelling, watering and well ramming in layers notexceeding 25 cms complete all as specified and directed.
6Removing excavated material not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above starting point complete all as specified and directed.
7Supplying and laying bricks common burnt clay sub class "B" old size for cable protection including taking down old one complete all as specified and as directed.
8Supply and laying dry river sand laid in trenches as cable cushioning and covering all as directed. Sand cushioning to underground electric cable 8 cm before laying and 15 cm after laying the cable in trenches complete all as specified and as directed.
9Material and labour for PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate), mechanically crushed stone for mass filling in pole pit and foundation etc including provision of necessary form work to achieve fair finished surfaces complete all as specified and as directed.
10Material and labour for PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in pole foundation, stay pits etc including provision of necessary form work to achieve fair finishes surfaces complete all as specified and directed.
11Material and labour for PCC (1:2:4) type C-2 (using 20 mm graded crushed stone aggregate) as in pole foundation, coping etc including provision of necessary form work to achieve fair finishes surfaces complete all as specified and directed.
12Disconnecting and taking out defective underground cable any size and any type from trenches, pole, pipe, floor, wall etc complete all as specified and as directed.
13Material and labour for LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross-sectional area 10 Sq mm, 4 core complete all as specified and as directed.
14Material and labour for LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross-sectional area 16 Sq mm, 4 core complete all as specified and as directed.
15Material and labour for LT underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade cross-sectional area 25 Sq mm, 4 core complete all as specified and as directed.
16Supply and fix indoor / outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 / 4.0 x 10-25 Sqmm complete all as specified and as directed by Engineer-in-Charge.
17Material and labour in replacement of PVC insulated and sheathed cable of size 1.5 Sqmm 3 core copper conductor multistranded 1100 Volt grade 230 Volts running through PVC conduit of dia 20 mm with strip clamping on poles at 3 places complete all as specified and as directed by Engineer-in-Charge.
18Material and labour for fixing in replacement galvanised iron tubing 50 mm bore light grade, on poles, on walls, under floors, road crossing, as required at site complete all as specified and as directed by Engineer-in-Charge. Note: - Clamps, Nut bolts, saddle etc will be measured and paid separately.
19Supply and fixing in repair onload change over switch with sheet steel enclosure 415 V, 4 pole, 63 Amps capacity fixed on walls for electric supply distribution between main and DG set including necessary connection of cables from LT panels to change over switches complete all as specified and directed by Engineer-in-Charge.
20Supply and fixing in repair onload change over switch with sheet steel enclosure 415 V, 4 pole, 100 Amps capacity fixed on walls for electric supply distribution between main and DG set including necessary connection of cables from LT panels to change over switches complete all as specified and directed by Engineer-in-Charge.
21Supply and fixing in replacement MCCB TPN 160 Amps, 415 Volts, 25 KA, 4 pole, Ics=100% Icu, overload adjustable short circuit fixed type including complete connection all as specified and as per directions of Engineer-in-Charge.
22Supply and fixing in replacement MCCB TPN 100 Amps, 415 Volts, 25 KA, 4 pole, Ics=100% Icu, overload adjustable short circuit fixed type including complete connection all as specified and as per directions of Engineer-in-Charge.
23Supply and fixing and fabrication street light bracket made out of GI tubing suitable for 45 / 60 / 90 watt LED light grade upto 1.2 metre length, bend to shape suitable for security light fitting with necessary mild steel clamps with one coat of red oxide primer and two coats of aluminium paint including nut, bolt, washers etc and including taking out unserviceable bracket and removing from site of work complete all as specified and as directed.
24Labour for repair / maint to old / unserviceable LED security / street / flood light of any capacity including taking down existing fitting from pole / building for repair of driver, cable terminal block and connection wire and refixing the same in position after repair including testing all as specified and directed by Engineer-in-Charge. Note: - Spares shall be measured and paid seperately under respective item.
25Taking down unserviceable street / security light fitting of any type from the pole / building after disconnecting electric connection carefully for replacement of drivers complete all as specified and directed. Note: - Repair / replacement of spares shall be measured separately.
26Supply and fixing in replacement of electronic driver of capacity 45 watt of existing make for LED street light fitting complete all as specified and as directed by Engineer-in-Charge.
27Supply and fixing in replacement of electronic driver of capacity 60 watt of existing make for LED street light fitting complete all as specified and as directed by Engineer-in-Charge.
28Supply and fixing in replacement of electronic driver of capacity 90 watt of existing make for LED street light fitting complete all as specified and as directed by Engineer-in-Charge.
29Supply and fixing in replacement of electronic driver of capacity 120 watt of existing make for LED street light fitting complete all as specified and as directed by Engineer-in-Charge.
30Supply and fixing in replacement of electronic driver of capacity 200 watt of existing make for LED flood light fitting complete all as specified and as directed by Engineer-in-Charge.
31Dismantling and taking down old unserviceable street / security lights and material and labour for new LED street light fittings of 30 watt, suitable for upto 50 mm outer dia holder fixed on existing pole, system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, silicon gasket for IP-66 protection suitable for pole mounting SMD led array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 110 lm/W, 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor >0.95, working temperature range -20ºC to 60ºC, built in surge protection more than 10 KV with facility of power supply shall be removed without removing light fitting from pole including making proper connections complete including cutting, welding, drilling holes, nut bolts, washer complete all as specified and as directed by Engineer-in-Charge.
32Dismantling and taking down old unserviceable street / security lights and material and labour for new LED street light fittings of 45 watt, suitable for upto 50 mm outer dia holder fixed on existing pole, system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, silicon gasket for IP-66 protection suitable for pole mounting SMD led array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 110 lm/W, 240 Volts AC, 50 Hz, CRI >70% operating voltage range 160 V-270 V, Power factor >0.95, working temperature range -20ºC to 60ºC, built in surge protection more than10 kV with facility of power supply shall be removed without removing light fitting from pole including making proper connections complete including cutting, welding, drilling holes, nut bolts, washer complete all as specified and as directed by Engineer-in-Charge.
33Dismantling and taking down old unserviceable street / security lights and material and labour for new LED street light fittings of 60 watt, suitable for upto 50 mm outer dia holder fixed on existing pole, system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, silicon gasket for IP-66, top opening separate driver compartment with frame, suitable for pole mounting SMD led array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 110 lm/W, 240 Volts AC, 50 Hz, CRI >70% operating voltage range 160 V-270 V, Power factor > 0.95, working temperature range -20ºC to 60ºC, built in surge protection more than 10 kV with facility of power supply shall be removed without removing light fitting from pole including making proper connection complete including cutting, welding, drilling holes, nut bolts, washer complete all as specified and as directed by Engineer-in-Charge.
34Dismantling and taking down old unserviceable street / security lights and material and labour for new LED street light fittings of 90 watt, suitable for upto 50 mm outer dia holder fixed on existing pole, system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, silicon gasket for IP-66, top opening separate driver compartment with frame, suitable for pole mounting SMD led array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 110 lm/W, 240 Volts AC, 50 Hz, CRI > 70% operating voltage range 160 V-270 V, Power factor >0.95, working temperature range -20ºC to 60ºC, built in surge protection more than 10 kV with facility of power supply shall be removed without removing light fitting from pole including making proper connection complete including cutting, welding, drilling holes, nut bolts, washer complete all as specified and as directed by Engineer-in-Charge.
35Dismantling and taking down old unserviceable street / security lights and material and labour for new LED street light fittings of 120 watt, suitable for upto 50 mm outer dia holder fixed on existing pole, system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, silicon gasket for IP-66, top opening separate driver compartment with frame suitable for pole mounting SMD led array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 110 lm/W, 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range -20ºC to 60ºC, built in surge protection more than 10 kV with facility of power supply shall be removed without removing light fitting from pole including making proper connection complete including cutting, welding, drilling holes, nut bolts, washer complete all as specified and as directed by Engineer-in-Charge.
36Dismantling and taking down old unserviceable street / security lights and material and labour for new LED flood light fittings of 120 watt, system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, silicon gasket for IP-66 protection suitable for pole mounting SMD led array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 90 lm/W, 240 Volts AC, 50 Hz, CRI >70% operating voltage range 160 V-270 V, Power factor > 0.95, working temperature range -20ºC to 60ºC, built in surge protection more than 10 kV with facility of power supply shall be removed without removing light fitting from pole including making proper connection complete including cutting, welding, drilling holes, nut bolts, washer complete all as specified and as directed by Engineer-in-Charge.
37Dismantling and taking down old unserviceable street / security lights and material and labour for new LED flood light fittings of 200 watt system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, silicon gasket for IP-66 protection suitable for pole mounting SMD led array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 90 lm/W, 240 Volts AC, 50 Hz, CRI >70% operating voltage range 160 V-270 V, Power factor > 0.95, working temperature range -20ºC to 60ºC, built in surge protection more than 10 kV with facility of power supply shall be removed without removing light fitting from pole including making proper connection complete including cutting, welding, drilling holes, nut bolts, washer complete all as specified and as directed by Engineer-in-Charge.
38Taking down old unserviceable timer switches and supply and fixing of automatic street light control with infrared sensor based nature switch and voltage monitoring system (VMS) single phase load of 8 KW for automation of street lights. Nature switch operation should be based on natural light lux level. Required illuminance level for switching ON is < 30 Lux and for switching OFF > 30 Lux. The sensor should also have part night operation facility of minimum 4 hours to maximum 12 hours. VMS should have adjustable over and under voltage trip level and protection against phase loss, neutral loss and phase reverse including power contactors (1 no"s of capacity 63 amps per phase each) and incoming (1 no"s of capacity 63 amps each) - outgoing MCB (1 no"s of capacity 63 amps each) and main load circuit wiring (Copper) of minimum 16 Sqmm. The sensor, VMS, Power contactor, MCB"s including connected items should be enclosed in a pole / wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP-54 complete all as specified and as directed.
39Supply and fixing SMC pole mounted box of size 10" x 8" x 4" with hinged door including clamp, nuts, bolts and washers complete all as specified and directed and including taking down of old unserviceable junction boxes. The Box includes: - (a) MCB single pole 10 Amp, 10 kA "C" series mounted on din rail - 1 No. (b) Connector block suitable for 3 phase, 4 wire minimum 16 Sqmm cable - 1 No. Make:- Syntex or equivalent of Hansel / Press fit.
40Material and labour for replacement of old unserviceable switch fuse unit / MCB of any type / capacity with new MCB FP 40 Amps 415 AC, 50 Hz, 25 kA with sheet metal enclosure complete all as specified and as directed.
41Material and labour for replacement of old unserviceable switch fuse unit / MCCB of any type / capacity with new MCCB FP 63 Amps 415 AC, 50 Hz, 25 kA with sheet metal enclosure complete all as specified and as directed.
42Material and labour for welding / cutting work for mild steel pipe of dia 80 to 150 mm at leakage pipe and fixing the pipe with new pipe of existing dia of and welding both side joints with required length of mild steel pipe to restore the water supply all as specified and as directed by Engineer-in-Charge. Note: - Rates are deemed to be including hiring of T&P required at site.
43Supply and fixing cast iron rising sluice valve both end flanged class PN 1.6 conforming to IS-14846-2000 with iron wheel head and brass spindle including necessary joint with nuts, bolt, washer, rubber or fibre board gasket, etc and testing complete all as specified and directed including taking down old one complete suitable for the following bore of pipes: -
44100 mm bore
45150 mm bore
46Note: - Rates quoted by the contractor inclusive of necessary arrangement required for fixing of the item.
47Supply and fixing cast iron non return valve both end flanged and fixed to the existing pipe line including joint with nut, bolt, washers, rubber or fibre board gasket, etc testing complete all as specified and directed including taking down old one complete suitable for the following bore of pipes: -
48100 mm bore
49150 mm bore
50Supply and fixing cast iron foot valve flanged end and swing type operating with rubber sheet as per IS : 4038 fixed to underground sump pipe 80 mm dia including joint with necessary fittings as required at site, including taking down old one complete all as specified and directed.
51Supply and fixing cast iron double orifice air release valve ISI marked IS: 14845 type DS2 in PN 1.0 flanged end with provision for inbuilt isolating valve to the existing pipe line including joint with necessary fittings as required at site, testing complete all as specified and directed including taking down old one complete suitable for the following bore of pipes: -
5280 mm dia
53100 mm dia
54150 mm dia
55Labour for repair / rectification of leakage of underground cast iron / DI pipe line of size 80 to 150 mm bore dia in position complete with excavation approximate 1.5 X 1.5 X 1.5 metre around the leakage, returning filling in, removal, cutting / dismantling of leakage complete with and including cocking to existing lead joint, filling new lead joint burning and taking out existing lead joint as per site requirement and restore the water supply complete all as specified and as directed. Note: - Spare / fitting shall be measured and paid separately.
56Material and labour for run lead joint for cast iron spigot and socket pipes and fittings of dia 150 mm bore with new lead complete all as specified and directed.
57Taking up cast iron / DI water mains (including all fittings) of dia 80 mm with spigot and socket ends and lead joints including burning out joints or flanged ends including disconnecting pipes and fittings complete all as specified and directed by Engineer-in-Charge.
58Taking up cast iron / DI water mains (including all fittings) of dia 100 mm with spigot and socket ends and lead joints including burning out joints or flanged ends including disconnecting pipes and fittings complete all as specified and directed by Engineer-in-Charge.
59Taking up cast iron / DI water mains (including all fittings) of dia 150 mm with spigot and socket ends and lead joints including burning out joints or flanged ends including disconnecting pipes and fittings complete all as specified and directed by Engineer-in-Charge.
60Supply and laying mild steel black pipe P/E ISI marked conforming to IS : 1239 Part - 1 (2004) of 80 mm dia bore medium grade (B class) with flanged joints at both ends as per site requirement in trenches, on ground or on the support above ground level by continuous welding joints 15mm thick flange joint, nuts and bolts and gaskets and testing complete, duly painted with two coats of bituminous paint externally all as specified and directed by Engineer-in Charge.
61Supply and laying mild steel black pipe P/E ISI marked conforming to IS : 1239 Part - 1 (2004) of 100 mm dia bore medium grade (B class) with flanged joints at both ends as per site requirement in trenches, on ground or on the support above ground level by continuous welding joints 15mm thick flange joint, nuts and bolts and gaskets and testing complete, duly painted with two coats of bituminous paint externally all as specified and directed by Engineer-in Charge.
62Supply and laying mild steel black pipe P/E ISI marked conforming to IS : 1239 Part - 1 (2004) of 150 mm dia bore medium grade (B class) with flanged joints at both ends as per site requirement in trenches, on ground or on the support above ground level by continuous welding joints 15mm thick flange joint, nuts and bolts and gaskets and testing complete, duly painted with two coats of bituminous paint externally all as specified and directed by Engineer-in-Charge.
63Notes for Ser Item No 52.00 to 54.00: - (a) Rates quoted by the contractor inclusive of necessary arrangement required for fixing of the item. (b) Flange joint and flange jointing materials, welding etc shall be deemed to be included in the quoted rates of pipe. (c) During execution of work if any damage to civil building, internet cables, electric cables, electric poles, road, nallah, the contractor is fully responsible and repair to damage will be executed by the contractor under own arrangements.
64Material and labour for mild steel fititngs such as bends (any type, radius and angles) bend to required shape by cutting and welding including flanges as required at site and testing complete all as specified for required size of bore 80 to 150 mm including taking down of old unserviceable materials complete all as directed. Notes: - (i) Mild steel fittings shall be of same make as of mild steel pipes or of make as recommended by manufacturers. (ii) The weight of the fittings shall be measured and paid as given in relevant IS or actually provided which ever is less. (iii) All fittings shall bear relevent IS stamping marking. (iv) Excavation and earth work shall be measured and paid for separately. (v) Cost of the joints and jointing materials shall be deeemed to be included in the relevant items.
65Material and labour for replacement of tubing galvanised iron "medium grade" of size 80 mm dia with flange ends and all fittings like nuts and bolts and gaskets laid in floor or borewells or trenches including taking out old unserviceable pipe of size 80 mm dia complete all as specified and directed.
66Material and labour for replacement of tubing galvanised iron "medium grade" of size 100 mm dia with flange ends and all fittings like nuts and bolts and gaskets laid in floor or borewells or trenches including taking out old unserviceable pipe of size 100 mm dia complete all as specified and directed.
67Material and labour for replacement of tubing galvanised iron "medium grade" of size 150 mm dia with flange ends and all fittings like nuts and bolts and gaskets laid in floor or borewells or trenches including taking out old unserviceable pipe of size 150 mm dia complete all as specified and directed.
68Supply and fixing cast iron / ductile iron specials for spigot and socketed / flanged cast iron / ductile iron pipes 150mm dia, such as bends (any type, radius and angle) tapers any type (straight bends, increasing, decreasing or double socket etc) tee, pieces, single branches "Y" junction, double branches cross (all sockets or socket and spigot) collars, caps and plugs, including taking out old unserviceable specials etc complete all as specified and as directed.
69Supply and fixing cast iron / ductile iron specials for spigot and socketed / flanged cast iron / ductile iron pipes 150mm dia, such as connecting pieces one end flanged and other socket or spigot and bell mouth pieces one end flanged other end tapering as bell mouth, including taking out old unserviceable specials etc. all as specified and directed by Engineer-in-Charge.
70Material and labour for cleaning to overhead RCC reservoir of any capacity internally at approximate 40 feet high stagging by using water treatment chemical / bleaching powder / sodium hypochloride chemical including cleaning internally entire wall surface, removing deposited particular, scrubbing complete wall surface and applying coat treatment water chemical on complete wall and drain out the water after disconnecting all rising / distrbution sluice valves complete with painting to mild steel / steel railing / rising / distribution / wash out cast iron pipe with different colour all as specified and directed and writing date of tank cleaning.
71Material and labour for rectification of leakage in distribution cast iron pipe line 150 mm bore dia of RCC overhead reservoir approximate at 40" to 60" height outside the reservoir near doom complete with replacement / cocking of lead, spun yarn, rubber gaskets, nut, bolt, washers of suitable size and made the pipe line leakage free all as specified and directed. Notes: - (i) Rates are deemed to be included charges of hiring T&P, Veh, Ladders, steel shuttering or any equipment required at site. (ii) Contractor shall be fully responsible for life insurance of the person deployed at site and get the repair under his supervision visitor from the qualified technician.
72Supply and fixing in replacement of electrical chemcal dozing systems complete suitable to injection of disinfection of water treatment having injection capacity 15 LPH comprising of FRP tank 100 litre capacity and chemical dosing pump at 10 Kg / cm² working pressure solenoid driven electrically controlled 220 Volt, maximum current 3.3 Amp, power 70 watt, single phase with IP-65 protection and F-Class insulated with standard fittings with stroke length suitable from 0-100% including all accessories such as foot valves / chemical mixing motor of suitable capacity / agitator with shaft and impeller, PE tubing, dosing tank FRP chemical resistant, inlet / outlet valve, drain valve, gauge, connection lead with plug and mild steel angle iron frame made out from 40 X 40 X 6mm to take the load of complete system all as specified and as directed. Make: - Jesco / Declibac / Prominent / Sathya Sai
73Supply and fixing in replacement of electrical chemcal dozing systems complete suitable to injection of disinfection of water treatment having injection capacity 15 LPH comprising of FRP tank 150 litre capacity and chemical dosing pump at 10 Kg / cm² working pressure solenoid driven electrically controlled 220 Volt, maximum current 3.3 Amp, power 70 watt, single phase with IP-65 protection and F-Class insulated with standard fittings with stroke length suitable from 0-100% including all accessories such as foot valves / chemical mixing motor of suitable capacity / agitator with shaft and impeller, PE tubing, dosing tank FRP chemical resistant, inlet / outlet valve, drain valve, gauge, connection lead with plug and mild steel angle iron frame made out from 40 X 40 X 6mm to take the load of complete system all as specified and as directed. Make: - Jesco / Declibac / Prominent / Sathya Sai
74Supply and fixing in replacement of OT solution chlorine test (500 ml) complete all as specified and as directed.
75Supply and fixing in replacement of chlorine test kit with coloured sample complete with all testing filaments and OT solution in rexin finish wooden box all as specified and directed.
76Supply and fixing in replacement of oil immersed star delta starter heavy duty manual operated suitable for submersible / VT pumping set with overload relay range 40 to 63 Amp, 415 volts, 50 Hz, 3 phase confirming to IS complete with initial filling of oil all as specified and as directed.
77Supply and fixing in replacement of oil immersed star delta starter heavy duty manual operated suitable for submersible / VT pumping set with overload relay range 63 to 100 Amp, 415 volts, 50 Hz, 3 phase confirming to IS complete with initial filling of oil all as specified and as directed.
78Supply and fixing in replacement of fully automatic star delta starter 3 phase, 415 volt, 50 Hz, suitable for submersible pumping set heavy duty with overload relay range suitable for 40 HP MU-G40 model L&T complete with provision of power contactor volt / Amp meter, push ON / OFF switch, selector switch, indicator etc. complete all as specified and as directed.
79Supply and fixing in replacement of fully automatic star delta starter 3 phase, 415 volt, 50 Hz, suitable for submersible pumping set heavy duty with overload relay range suitable for 50 HP MU-G50 model L&T complete with provision of power contactor volt / Amp meter, push ON / OFF switch, selector switch, indicator etc. complete all as specified and as directed.
80Supply and fixing in replacement of fully automatic star delta starter 3 phase, 415 volt, 50 Hz, suitable for submersible pumping set heavy duty with overload relay range suitable for 75 HP MU-G75 model L&T complete with provision of power contactor volt / Amp meter, push ON / OFF switch, selector switch, indicator etc. complete all as specified and as directed.
81Supply and fixing in replacement of submersible motor rotor for 20 to 25 HP motor complete with bearing upper / lower bearing housing, sleeves, tee bolts and bush complete all as specified and directed by Engineer-in-Charge.
82Supply and fixing in replacement of submersible motor stater for capacity 20 to 25 HP complete with thrust plate, thrust bearing with housing, studes, water seal, sand guard, rubber diaphragm with plate, sealing bush complete all as specified and directed by Engineer-in-Charge.
83Supply and fixing in replacement of submersible cable 10 Sqmm 3 core flat copper conductor heavy duty 1100 volts grade confirming to ISI including taking down of old unserviceable submersible cable all as specified and directed by Engineer-in-Charge.
84Supply and fixing in replacement of submersible cable 16 Sqmm 3 core flat copper conductor heavy duty 1100 volts grade confirming to ISI including taking down of old unserviceable submersible cable all as specified and directed by Engineer-in-Charge.
85Supply and fixing in replacement of submersible cable 25 Sqmm 3 core flat copper conductor heavy duty 1100 volts grade confirming to ISI including taking down of old unserviceable submersible cable all as specified and directed by Engineer-in-Charge.
86Supply and fixing in replacement of onload open execution change over switch front handle operated 4 pole, 415 volt, 50 Hz, 125 Amp confirming to IS all as specified and directed by Engineer-in-Charge.
87Supply and fixing in replacement of onload open execution change over switch front handle operated 4 pole, 415 volt, 50 Hz, 200 Amp confirming to IS all as specified and directed by Engineer-in-Charge.
88Transporting air compressor and other allied equipment / material at site of tube well and installation of complete machinery for re-development of tube well all as specified and as directed by Engineer-In-Charge.
89Re-development of tube well with air compressor of adequate capacity (not less than 250 Cfm) as per specification till the availability of sand free clear water, subject to minimum of 60 hours of operation of air compressor (60 x 4500) complete all as specified and as directed.
90Providing of pea shaped gravel as per specification and gravel shrouding in annular space between well and liner assembly required during re-development complete all as specified and as directed.
91Material and labour for strip opening complete submersible pumping set having capacity 20 to 50 HP any stage / discharge and dismantling all spare parts by opening studs complete with machine / lathe work / grinding / polishing and fitting of all spare parts and re-assembling / installation in position after necessary repair / replacement of unserviceable / defective spare parts complete all as specified and as directed. Note: - Spare parts shall be measured and paid separately under respective items as under: -
92Supply only cast iron stage bowl.
93Supply only cast iron suction discharge chamber.
94Supply only stainless steel neck ring.
95Supply only stainless steel bowl bush.
96Supply only stainless steel coupling sleeves.
97Supply only cast iron impeller with key.
98Supply only body studs fully threaded.
99Supply only stainless steel pump shaft.
100Supply only stainless steel pump shaft coupling with key.
101Supply only cast iron NRV with NRV seat and cone.
102Supply only stainless steel sleeves for bowl.
103Supply only rubber bush.
104Supply only strainer for pump.
105Material and labour for strip opening to submersible motor / VT motor having capacity 20 to 50 HP and re-winding with super enamelled copper winding wire heavy duty heat resistance confirming to IS of same gauge and numbers of turns complete with realignment of motor slotes and insulating mateials i.e. varnishing, bamboo strips, leather papers, cotton tapes including replacement of unserviceable / defective spare parts and drying complete and re-assembling after repair / rewinding and testing at site on full head complete all as specified and as directed. Note: - Spare parts shall be measured and paid separately under respective item as under: -
106Supply only thrust plate with circlip and key.
107Supply only thrust plate bearing housing.
108Supply only bearing for motor.
109Supply only rubber oil seal.
110Supply only cast iron sand guard.
111Supply only rubber diaphragm with plate.
112Supply only stainless steel sealing bush.
113Supply and fixing Altoch packing of 45 Kg complete all as specified and as directed.
114Material and labour for replacement of cast iron pipe with flanged ends centrifugally cast class "B" of any length including suitable nuts and bolts and gaskets conforming to ISI laid in trenches of size 150 mm bore complete all as specified and as directed.
Disclaimer :