Tender For Repair And Maintenance Of Summer Winter Appliances And Bldg Security And Perimeter Lights At Haft Chinar And Tattoo Grd Under Ge 970 Ews, SRINAGAR-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Repair And Maintenance Of Summer Winter Appliances And Bldg Security And Perimeter Lights At Haft Chinar And Tattoo Grd Under Ge 970 Ews. Submission Date for this Tender is 26-11-2022. Bath and Body Tenders in SRINAGAR Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

34580612
Corrigendum : Tender For Repair And Maintenance Of Summer Winter Appliances And Bldg Security And Perimeter Lights At Haft Chinar And Tattoo Grd Under Ge 970 Ews
Open Tender
Indian
Jammu And Kashmir
SRINAGAR
26-11-2022

Tender Details

Repair And Maintenance Of Summer Winter Appliances And Bldg Security And Perimeter Lights At Haft Chinar And Tattoo Grd Under Ge 970 Ews

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Nov-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 26-11-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 52000.0 /-
Tender Value
INR 26 Lakhs /-

BOQ Items

Name of Work: REPAIR AND MAINT OF SUMMER WINTER APPLIANCES AND BLDG SECURITY AND PERIMETER LIGHTS AT HAFT CHINAR AND TATTOO GRD UNDER GE 970 EWS
Sl. No. Item Description
1M&L for opening the unserviceable/burnt ceiling fan 1200/1400 mm sweep and cutting of old burnt copper windingand rewinding the same with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnish, reassembling, testing and connecting for satisfactory run, complete all as specified and directed (NOTE:- Taking down/dismantling of ceiling fan and refixing after repair shall deemed to be include in this unit rate.)
2Supply and fixing in repair of ball bearing of the ceiling fan (any sweep) as per existing size incl greasing/oiling, complete all as specified and directed by engr-In-Charge. Make:- SKF/ NBC or Equivalent
3Supply and fixing in repair of gun metal bushes of suitable size for ceiling fan incl necessary mechanical work, complete all as specified and directed by Engr-In-Charge.
4Supply and fixing in repair of flexible cable, three core 0.5 SqmmPVC insulated copper conductor cable for connecting ceiling fan, complete all as specified and directed. Make:- Plaza, Havells .
5Supply and fixing in repair capacitor of of 3.15 MFD for ceiling fan, complete all as specified and directed.
6Supply and fixing in repair capacitor of 4 Mfd for exhaust fan, complete all as specified and directed.
7Supply and fixing in repair of ceiling fan blade set of three, heavy duty suitable for 1200/1400mm sweep of as per existing make as direcetd.
8Supply and fixing in repair of PVC canopy for ceiling fan 1200/1400mm sweep complete for existing various makes/model of fan, complete all as specified and directed by Engr-in-Charge.
9M&L in repair for opening and cutting of old burnt copper winding of exhaust fan and rewinding of exhaust fan motor of sweep 450mm with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnish, re-assembling, testing and connecting for satisfactory run, complete all as specified and directed as specified and directed. (NOTE:- Taking down/dismantling of exhaust fan and refixing after repair shall deemed to be include in this unit rate.)
10All as per srl item No. 9 here-in-before, but 300mm sweep.
11Supply and fixing in repair ball bearing of exhaust fan of any size/make as per the existing, complete all as specified and directed. Make: SKF/NBC or equivalent .
12M&L for painting the exhaust fan including louvers of size 300/450mm sweep with two coats of synthetic enamel paint after cleaning and making the surface of oil/dust free, complete all asspecified and directed.
13M&L for servicing of geyser by disconnecting the electric and water supply connections, dismantling the geysers of any size, type & capacity and opening the top and bottom cover, thermostat, heating element, safety valve, vent pipe, separating inner & outer tank, removing glass wool insulation complete and keeping aside for re-use after de-scaling of inner tank by liquid chemical and with pressure water jet and assembling back the geyser including re-installation on wall with studs, nuts & bolts complete and testing after reconnecting electric and water connections, complete all as specified and directed.
14Supply and fixing in repair heating element for geyser of capacity 1.5KW, AC 230 Volts, 50 Hz (as per sample), complete all as specified and directed. Make:-Micron/ Bajaj/ Havells
15Supply and fixing in repair Heating element for geyser of capacity 2.0KW, AC 230 Volts, 50 Hz (as per sample), complete all as specified and directed. Make:-Micron/ Bajaj/ Havells
16Supply and fixing in repair thermostat for Geyser of capacity 25/35/50/100 ltr (long size) with temperature setting adjustment range from 40 to 85°C, ISI Marked, complete all as specified and directed. Make:- Philips/ Bajaj/ Venus
17Supply and fixing in repair geyser syphon assembly Set suitable for 25 ltr capacity geyser, fixed in replacement, as per existing complete all as specified and directed by engr-in-Charge.
18All as per item Srl No. 17 above butfor 35 Ltr capacity.
19All as per item Srl No. 17 above butfor 50 Ltr capacity.
20Supply and fixing in repair rubber gasket for water heater storage type of any capacity and suitable as per the existing, complete all as specified and directed
21Supply and Fixing in repair plug top 15/16 Amps for Geyser, complete all as specified and directed. Make:- Havells/ Anchor/Leader/Plaza
22Supply and fixing in repair PVC sheathed three core copper conductor flexible wire of size 2.5 Sqmm for connecting geyser, complete all as specified and directed. Make:- Finolex/Polycab/L&T
23Supply and fixing in repair of safety valve for geyser of 25/35/50 litre capacity, as per existing make complete all as specified and directed
24Supply and fixing in repair of non return valve 15mm dia for geyser of 25/50 litre capacity, complete all as specified and directed.
25Supply and fixing in repair heavy duty PVC connector 600mm long 15mm dia with PTMT nut for geyser of 25/50 litre capacity, complete all as specified and directed.
26Supply and fixing in repair copper inner tank of geyser capacity 15/25 litre and refilling of glass wool, refixing, connecting and testing, complete all as specified and directed.
27All as per item Srl No. 26 above butfor 35 Ltr capacity.
28All as per item Srl No. 26 above butfor 50 Ltr capacity.
29Supply and fixing in repair of GI anchor Bolt100 mm long with nut & washers for geyser, complete all as specified and directed
30Supply and fixing in repair of compressor fo refrigerator of 165 to 200 ltr capacity as per the existingcomplete all as specified and directed.
31Supply and fixing in repair of thermostatfor refrigerator of 335 ltr capacity.
32Supply and fixing in repair of thermal relay for refrigerator of 335 ltr capacity.
33M&L for Charging refrigerant R134A and testing for proper cooling and leakage complete for refrigerator of 165 to 335 ltr capacity all as specified and directed.
34Supply and fixing in repair of compressor fo refrigerator of 210 to 335 ltr capacity as per the existingcomplete all as specified and directed.
35Supply and fixing in repair of thermostatfor refrigerator of 210 to 335 litre capacity.
36Supply and fixing in repair of thermal relay for refrigerator of 210 to 335 litre capacity.
37M&L charging refrigerant R134A and testing for proper cooling and leakage complete for refrigerator of 210 to 335 ltr capacity all as specified and directed.
38Supply and fixing in repair of thermostatfor deep freezer of 210 to 335 litre capacity.
39Supply and fixing in repair of thermal relay for deep freezer of 210 to 335 litre capacity.
40M&L for Charging refrigerant R134A and testing for proper cooling and leakage complete for deep freezer of 210 to 400 ltr capacity all as specified and directed.
41M&L for disconnecting the electric supply from the mains, transporting the window/split type air conditioner capacity 1.5/2.0 ton from original location to workshop to carry out the servicing complete and re-fixing at the original position after repairs and making the ACs fully functional and testing for satisfactory working, complete all as specified and directed.
42Taking out old burnt/unserviceable compressor from the air conditioner 1.5/2.0 ton capacity and supply and fixing new compressor as per the existing, re-fixing in position incl testing satisfactory working complete all as directed.
43M&L for charging refrigerant gas R134A in 1.5/2.0 ton capacity window /Split type air conditioner complete including testing for satisfactory working after flushing out and cleaning the surface with nitrogen gas for checking the leakage, complete all as specified and directed.
44Supply and fix in repair blower motor suitable for 1.5/2.0 ton capacity air conditioner all as directed.
45Supply and fix in repairthermostat suitable for 1.5/2.0 ton capacity air conditioner all as directed.
46Supply and fix in repair of running condenser 36 Mfd, complete all as directed.
47Supply and fix in repair of starting condenser 100/120 Mfd, complete all as directed.
48Supply and fix in repair of relay suitable for 1.5/2.0 ton capacity air conditioner, complete all as directed.
49Taking out unserviceable/burnt stabilizer of 3 KVA to 5 KVA capacity, rewinding the same with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnish, reassembling, replacement of knobs, LED"s etc. and making fully functional on load as connected to Refrigerator/Deep freezer/AC complete all directed.
50All as per item Srl No. 49 above butforcapacity 1 to 2 KVA .
51M&L for Dismantling the complete fuel injector pump of water heating plant of various capacity upto 2000 ltrs, transporting to trade workshop for repairs and complete servicing and refixing the same after satisfactory repairs, reinstallation, testing and commissioning complete, all as specified and directed.
52Material and labour for calibration and complete repair of fuel injection pump of water heating plant of various capacity upto 2000 ltrs, on work bench for fine spray and machining work and refixing the same for satisfactory functioning, complete all as specified and directed.
53Supply and fix in repair nozzleof hot water plant as per existing size complete all as specified and directed.
54Supply and fix in repair pressure meter suitable for hot water generator as per existing size complete all as specified and directed.
55Supply and fix in repair fuel filter suitable for hot water generator as per existing sizecomplete all as specified and directed.
56Supply and fix in repair solenoid switch for hot water generator as per existing size complete all as specified and directed.
57Supply and fix in repair burner gasket suitable for hot water generator as per existing size complete all as specified and directed.
58Supply and fix in repair digital type electronictemprature gauge with thermostat control relay suitable for 2,00,000 K Cal/hr capacity hot water generator as per existing size and testing complete all as specified and directed.
59Supply and fix in repair indicator assembly, complete all as specified
60Supply and fix in repair bimetallic overload relay 4.0 - 6.5 Amps type ML complete all as specified
61Supply and fix in repair electromagnetic rod combined with positive/ negative terminals suitable for hot water generator of any capacity as per existing size and testing complete all as specified and directed.
62Supply and fix in repair photo censor suitable for hot water generator/plant as per existing size and make incl testing complete all as specified and directed.
63Supply and fix in repair high pressure diesel/fuel pipe with internal and outer threads suitable for hot water generator/plant as per existing size incl testing complete all as specified and directed.
64M&L for dismantling fuel tank of water heating plant, servicing, decarboning, cleaning, removing ofof complete water plant and reassembling the same after cleaning properly by removing all deposited particles, dust, carbon etc, complete all as specified and directed.
65M&L for disconnecting and taking out burnt hot water plant blower motor, transporting to workshop, dismantling carefully, cutting out burnt windings, cleaning the slots and rewinding with super enamelled copper winding wire of appropriate gauge & weight incl all insulating materials, varnishing, drying, heating etc and incl replacement of ball bearings as per existing, reassembling and refixing at original site and testing, complete all as specified and directed.
66Supply and fix LED bldg security light fitting 24 watts with high efficiency long life LEDs In-built replaceable electronic driver complete housed in pressure die-cast aluminium alloy covered with polycarbonate cover with IP65 degree of protection and fixing on existing bracket including taking down existing unserviceable street light fitting complete all as specified and directed. Make:Bajaj Cat No. ENXT P 24L WH CR PC SDorlatest upgraded equivalent model in Havells/ Wipro/Crompton Greaves
67Supply and fix LED street light fitting 45 watts with high efficiency long life LEDs In-built replaceable electronic driver complete housed in pressure die-cast aluminium alloy covered with polycarbonate cover with IP65 degree of protection and fixing on existing bracket including taking down existing unserviceable street light fitting complete all as specified and directed. Make:Bajaj Cat No. ENXT P 54L WH CR PC SDorlatest upgraded equivalent model in Havells/ Wipro/Crompton Greaves
68All as per item No. 67 here-in-before but of 60 watt---ditto--- Make:Bajaj Cat No. ENXT P 72L WH CR PC SDorlatest upgraded equivalent model in Havells/ Wipro/Crompton Greaves
69Supply and fixing in repair electronic driver with Input Voltage 220 to 240 Volt and Output Voltage suitable for LED Light Fitting of capacity 45 to 60 Watt, complete all as specified and as directed. Make: Philips/Havells/ Crompton Greaves/ Wipro/Bajaj/Surya
70S & Fin repairs Thermoplastic Cable Junction Box/Distribution Board size 333 x 233 x 105 mm, IP 65 with metric knockouts for cable entry of size 10 to 25 sq mm, 2 core including fastening clamp with LT pole, box hinged cover with locking arrangements including with terminals TPNstrip,with 01 No MCB SP 6A "B" Serials complete allasspecifiedanddirected.
71Supply and fixing in repair PVC insulated, 3 core cable with stranded copper conductor of size 1.5 sqmm for street light complete all as specified and directed. Make: Finolex/ Polycab/ Havells
72Excavationintrenchesnotexc 1.5 M wideandnotexc1.5 Mindepthandgettingoutin soft/loosesoilorhard/densesoilfortakingup orlaying ofcable & electrical poles etc. complete allasspecifiedanddirected.
73Returning, filling inincludingspreading, levelling, wateringandwellramminginlayersnotexceeding25 cms complete allasspecifiedanddirected.
74Removing surplus soil to a distance not exc. 50m and depositing where directed at a level n. exc. 1.5m above the starting point complete all as specified and directed.
75Supplyandlayingdryriversand to belaidin 8 cms before laying of cable and 15 cms above cable in trencheascablecushioningandcovering complete allasspecifiedanddirected. Note: for payment purpose punned thickness shall be measured
76M/Lfor brickwell burntlocallyavailablesubclass "B" laid over sand cushioningtocableintrencheskeepingwidthofbrickparalleltothelengthofcable complete allasspecifiedanddirected.
77Supply and laying, of XLPE under groundinsulated, armoured,heavy duty LT 1100 volts 25 Sqmm 4 core grade cable with aluminium conductor ISI markedas per IS-70098 (Part-I), laid in trenches/pipes, fixed topoles/walls with suitable saddle & glands complete all as directed incl taking out the old burnt out cables all as specified and directed. NOTE - Excavation, earthwork, sand cushioning and brick protection shall be measured and paid separately under respective items.
78All as per item No. 77 above but 35 Sqmm 4 core -ditto-
79All as per item No. 77 above but 16 Sqmm 4 core -ditto-
80Supply and fixing in repair of steel tubular poles complete with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410 SP-31 (9.0 mtr long) and shifting of conductors and insulators etc incl painting the exposed portion of the pole with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer. Marking of pole number with black paint in yellow circle complete all as specified and directed.
81Material & labour for cement concrete 1:4:8 typeD-2 (using 40mm graded stone aggregate) for foundation of pole complete all as specified and directed.
82Material & labour for cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) as in coping of pole complete all as specified and directed.
83Material & labour for cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in coping of pole complete all as specified and directed.
84Supply and Fix in repair for street light fitting bracket made out of 32mm bore GI pipe, light grade,bend to shape, 1.2 metre long, fixed to pole/wall with and including two sets of clamps made out of flat iron of size 50 x 6 mm with bolts, nuts and washers, complete all connected accesories for fixing of GI bracket with pole including one coat of anti corrosive primer and two coats of aluminium paint, all as specified and directed.
85Supply and fix in repairs galvanised iron tubes 50mm bore, light gradeincluding all fittings fixed to wall, ceilings andor laid in floors/tenches/under road etc complete for cable protection all as specified and directed.
86S&F moulded case circuit breaker four pole 100 Amps,16 KA capacity 415V 50Hz with adjustable thermal and fixed magnetic relay incl taking out the old unserviceable complete all as specified and directed.
87Supply and Fix in repairOn load change over switch in sheet metal enclosure of capacity 100 Amps, 4P, 415V complete all as specified and directed.
88Supply and fix LED ?ood light fitting of 150 Watts with driver inside a pressure die cast aluminium housing with toughened front glass cover, IP65 degree of protection includig taking down of existig unserviceable flood light fitting of any description complete all as specified and directed. Make: Bajaj Cat No. BJFL 150W LED I orlatest upgraded equivalent model in Havells/ Wipro/Crompton Greaves
89All as per Ser Item No. 88 here-in-before but of 240 Watts ---ditto--- Make: Bajaj Cat No. BJFL 200W LED Iorlatest upgraded equivalent model in Havells/ Wipro/Crompton Greaves
90Supply and fix LED post top light fitting made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection20 watts with high efficiency long life LEDs In-built replaceable electronic driver complete fixing on existing bracket including taking down existing unserviceable street light fitting complete all as specified and directed.. Make:Bajaj Cat No. BGCL 40W LED WHorlatest upgraded equivalent model in Havells/ Wipro/Crompton Greaves
91M&L painting of steel tubular pole 9.0 mtr long, by applying one coat of alluminium paint after scraping / brushing and cleaning the rust on pole and cross arms . Alluminium painting will be done on pole above 1.5 Mtr hight from ground level and balance 1.5 mtr from groundlevel will be painted by alternate layer of black and white enammelled paint ( 30 cms each) Pole Nos will be written on pole by black paint in yellow circle of 150mm diacomplete allasspecifiedanddirected.
92M&L for disconnectiong existing defective 500Ltr capacity Heating plant/ Hamam from electric mains, water mains and fuel pump, isolatE the necked connections, removing from foundation by unscrewing the nuts, bolts etc, discouple from pump and motor, opening of Heating plant/ Hamam and motor for inspection in presence of Engr-in-Charge and to carry out major repairs transporting to workshop and back, reassembling the Heating plant/ Hamam after repair, refixing in position reconnecting same as prior to removing from foundation including replacement of nuts, bolts washers of suitable size, testing and commissioning complete all as specified and directed. Disconnecting the Heating plant and remove the SS inner and outer tank carefully, carry to trade workshop for necessory repairs such as :- (a) Cut the rust out parts of 500 Ltr capacity Heating plant/ Hamam. (b) Moulding of inner tank of 500 Ltr capacity Heating plant/ Hamam and welding work. (c) Moulding of outer tank of 500 Ltr capacity Heating plant/ Hamam and welding work. (d) Supply and filling in replacement of Glass wool between the inner and outer tank. (e) Supply and fixing in replacement upper and lower aluminium strap for suitable size. (f) Supply and fixing in replace ment of necessory quanty and size of nut,bolt and washer. (g) Supply and fixing in replacement of Base plate of 500 Ltr capacity Heating plant/ Hamam of existing size with GI plate of minimum 5 mm thick (h) Supply and fixing in repair of water connection arrangement of water Heating plant/Hamam i.e, Nipple,socket, reducer socket and Gate valve/ ball valve etc. (j) Repair/ replacement of Top and bottom cover. (k) Other miscellanious Repairs. (l) Supply and eplacement of inner (Dollaky) Plates 5 mm thick. (m) Supply and replacement of Vertical MS tubes size of 50 mm. Note:- (i) Replacement of defecting shall deemed to be include in the qouted rate. (ii) Major repairs are not possible at site, the Heating plant/ Hamam shall be shifted to Civil workshop, and cost of shifting to workshop and back to site after repair will be include in the quoted rates. Loc: 54 RVC - 01, ARO - 1
Disclaimer :