Tender For Land Development And Construction Of Boundary Wall For Girish Moran Memorial Cultural Multipurpose Complex Under One Time Special Grant For Development Of Moran Community For The Year 2021-22
Tender Value
57.46 Lakhs
Estimated cost
Bid Submission
09 Nov 2022
0 days left
EMD
1.14 Lakhs
Bank guarantee accepted
Document Fee
1150
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
moran → Assam
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Land Development And Construction Of Boundary Wall For Girish Moran Memorial Cultural Multipurpose Complex Under One Time Special Grant For Development Of Moran Community For The Year 2021-22
BOQ
| Sl. No. | Item Description |
| 1 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings. Bases of columns, etc. for mass concrete. |
| 2 | Centering and shuttering including strutting, propping etc. and removal of form for: Walls (any thickness) including attached pilasters, butteressess, plinth and string courses etc. |
| 3 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 4 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form for Stairs, (excluding landings) except spiral-staircases |
| 7 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 9 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 10 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 11 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 12 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Mild steel and Medium Tensile steel bars |
| 13 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flates, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding |
| 14 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 15 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) |
| 16 | Precast terrazo tiles 22 mm thick with graded marble chips of size upto 12 mm, laid in floors, and landings, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbingand polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement:4 coarse sand) : Light shade pigment using white cement |
| 17 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \"T\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC ( NoiseReduction Coefficient) of 0.85, with 50 mm thick rockwool of 48 kg /cum backing. |
| 18 | Providing wood work in frames of doors, windows, clerestory windows andother frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak wood |
| 19 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) Second class teak wood 35 mm thick shutters |
| 20 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : First layer of slurry of cement @0.488kg/sqm mixed with water proofing cement compound @0.253kg/sqm. This layer will be allowed to air cure for 4 hours. Second layer of slurry of cement @0.242kg/sqm mixed with water proofing cement compound @0.126kg/sqm. This layerwill be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 21 | Providing and applying intehral crystalline slurry of hydrophillic in nature for water proofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservoir, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5:2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3:1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self healing of cracks upto a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guaranteed for 10 years against any leakage. For vertical surface two coats @0.70 kg per sqm per coat. |
| 22 | Providing and applying intehral crystalline slurry of hydrophillic in nature for water proofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservoir, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5:2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3:1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self healing of cracks upto a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guaranteed for 10 years against any leakage. For horizontal surface one coat @ 1.10 kg per sqm. |
| 23 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete |
| 24 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification. Two or more coats on new work |
| 25 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid |
| 26 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. 10 litre capacity - White |
| 27 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 28 | Providing and fixing kitchen sink including making all connections excludingcost of fittings. White glazed fire clay sink of size 600x450x250 mm |
| 29 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Circular shape 450 mm dia |
| 30 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 31 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms |
| 32 | Providing and fixing soil, waste and vent pipes : 100 mm dia Sand cast iron S&S pipe as per IS: 1729 |
| 33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall. 32 mm nominal dia Pipes |
| 34 | Providing and fixing brass bib cock of approved quality : 20 mm nominal bore |
| 35 | Providing and fixing brass stop cock of approved quality : 20 mm nominal bore |
| 36 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 37 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 38 | Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubberinsertions etc. (The tail pieces if required will be paid separately) : 80 mm dia nominal bore |
| 39 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. All types of soil 300 mm dia |
| 40 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia |
| 41 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. |
| 42 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm dia |
| 43 | Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp |
| 44 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sq.m. on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto1.5m, as directed by Engineer-in-charge. All kinds of soil. |
| 45 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50m and lift upto 1.5m. |
| 46 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20mm nominal size). |
| 47 | 1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20mm nominal size). |
| 48 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size). |
| 49 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 50 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement Mortar 1:4 (1 cement : 4 coarse sand). |
| 51 | Providing soling in foundation and under floorwith stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labourand materials and if necessary dewatering, complete. (a) Brick on flat soling. |
| 52 | Neat cement punning. |
| 53 | Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg |
| 54 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 55 | Supplying and stacking at site. 63 mm to 45 mm size stone aggregate |
| 56 | Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density . |
| 57 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. |
| 58 | Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete. |
| 59 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 60 | Wiringforlightpoint/fanpoint/exhaustfanpoint/callbell pointwith1.5sq.mmFRLSPVCinsulatedcopperconductor singlecorecableinsurface/recessed steelconduit,with modular switch, modular plate, suitable GI box and earthing the pointwith1.5sq.mmFRLSPVCinsulatedcopperconductor single core cable etc. as required. Group-A |
| 61 | Wiringforlightpoint/fanpoint/exhaustfanpoint/callbell pointwith1.5sq.mmFRLSPVCinsulatedcopperconductor singlecorecableinsurface/recessed steelconduit,with modular switch, modular plate, suitable GI box and earthing the pointwith1.5sq.mmFRLSPVCinsulatedcopperconductor single core cable etc. as required. Group-B |
| 62 | Wiring for circuit/ submain wiring alongwith earth wire with the followingsizes of FRLS PVC insulatedcopper conductor,single core cable in surface/rcessed steel conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 63 | Wiring for circuit/ submain wiring alongwith earth wire with the followingsizes of FRLS PVC insulatedcopper conductor,single core cable in surface/rcessed steel conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 64 | Supplyingandfixingfollowingmodularswitch/socketon the existing modular plate & switch box includingconnectionsbut excluding modular plate etc. as required. 5/6 A switch |
| 65 | Supplyingandfixingfollowingmodularswitch/socketon the existing modular plate & switch box includingconnectionsbut excluding modular plate etc. as required. 15/16 A switch |
| 66 | Supplyingandfixingfollowingmodularswitch/socketon the existing modular plate & switch box includingconnectionsbut excluding modular plate etc. as required. 3 pin 5/6 A socket outlet |
| 67 | Supplyingandfixingfollowingmodularswitch/socketon the existing modular plate & switch box includingconnectionsbut excluding modular plate etc. as required. 6 pin 15/16 A socket outlet |
| 68 | Supplyingandfixingfollowingmodularswitch/socketon the existing modular plate & switch box includingconnectionsbut excluding modular plate etc. as required. Bell push |
| 69 | Supplyingand fixing twomodulestepped type electronicfan regulatorontheexistingmodularplateswitchboxincluding connections butexcluding modular plate etc. as required. |
| 70 | Supplyingand fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 4 Module (125mmX75mm) |
| 71 | Supplyingand fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 6 Module (200mmX75mm) |
| 72 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 4 Module |
| 73 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 6 Module |
| 74 | Wiring forlight/ power plug with4X4sq.mmFRLS PVC insulated copper conductor single core cable in surface/ recessed mediumclass PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 75 | Supplyingandfixing5Ato32A rating, 240/415V, 10kA,\"C\" curve,miniaturecircuitbreakersuitableforinductiveloadof followingpolesinthe existingMCB DBcompletewith connections, testing and commissioning etc. as required.Single Pole |
| 76 | Supplyingandfixing5Ato32A rating, 240/415V, 10kA,\"C\" curve,miniaturecircuitbreakersuitableforinductiveloadof followingpolesinthe existingMCB DBcompletewith connections, testing and commissioning etc. as required.Double Pole |
| 77 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia includingaccessories,andprovidingmasonryenclosurewith cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 78 | Supplyingandlaying 6 SWG G.I. Wire at 0.50 metrebelow groundlevel for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 79 | Providingandfixingof lightningconductorfinial,madeof 25mm dia 300 mm long, G.I. tube, having single prong at top, with 85mmdia6mmthickG.I.baseplateincludingholesetc. complete as required. |
| 80 | Supplyingandfixing3pin,5Aceilingroseontheexisting junction box/wooden block includingconnections etc. as required. |
| 81 | Installation,testing and commissioningof ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, includingprovidingandfixingphenoliclaminatedsheetcover on thr fan box etc. as required. |
| 82 | Laying ofone numberPVC insulated and PVC sheathed/ XLPE powercableof11KVgradeoffollowingsizedirectinground includingexcavation,sandcushioning,protectivecoveringand refilling the trench etc as required. Upto 120 sq. Mm |
| 83 | Supplying of following sizes XLPE insulated and PVC sheathed aluminium conductorarmored power cable of 11 KV grade conforming to IS 7098(Part - 1)/ 1988 with ammendment upto date etc. as required. 2X 10sq.mm. |
| 84 | Supply including fitting fixing of LED Tube Light 4 Ft. 20W 6500K, MAGIKmake CAT No. BWUA020W1295 as directed & specified by the deptt. |
| 85 | Supply of LED Bulb 15W, 1200 lumen, HPL make Product code HPLLEDB01265B22 as directed & specified by the deptt. |
| 86 | Supply including fitting fixing of A.C.Ceiling fanwith allaccessories like down rod, canopy etc. as directed & specified by the deptt.( HAVELLSmake) of MODEL- SS-390 METALIC 1200mm Sweep |
| 87 | Supply including fitting fixing of A.C.Exhaust fan of 300mm sweep in the existing holeincluding connections & making good damage done, complete as directed &specified by the deptt.( HAVELLSmake) of MODEL- Ventil Air - DSP METALLIC RANGE 300 mm. Sweep |
| 88 | Supplying fitting fixing of LED Street light uminaries with all acessories including connectionetc. complete as per direction of the department. |
| 89 | Supply including installation of Self Priming Mono Block Pump Set of 1 HP capacity as directed by the department.( Havells make ) |
| 90 | Payment to be made to APDCL authority for Load Security 6 k.w.load including installation of 3 phase Meter, Service connection etc. |
| 91 | Supply including fitting fixing of 1.5 Ton split type Air Conditioner, convertible, 3 Star rating including Voltage Stabilizer, with all acessories including connections etc. as specified and directed & by the department.(L G make) |
AI Tender Summary
Tender Timeline
Oct 29, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedNov 09, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedNov 09, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender