}

Bids Are Invited For Civil Related Work Of Aerosol Lab Devasthal - 1 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5M In Width Or 10 Sqm On Plan ) , , Nainital-Uttarakhand

Department Of Science And Technology has published Bids Are Invited For Civil Related Work Of Aerosol Lab Devasthal - 1 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5M In Width Or 10 Sqm On Plan ) , . Submission Date for this Tender is 31-10-2022. Coats and Jackets Tenders in Nainital Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

34570218
Bids Are Invited For Civil Related Work Of Aerosol Lab Devasthal - 1 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5M In Width Or 10 Sqm On Plan ) ,
Open Tender
Indian
Uttarakhand
Nainital
31-10-2022

Tender Details

Bids Are Invited For Civil Related Work Of Aerosol Lab Devasthal - 1 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Bottoms, Lift Upto 1.5M, Including Geting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M And As Directed By Engineer-In-Charge. All Kinds Of Soil. 2 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means Over Areas ( Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10Sqm On Plan ) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. All Kinds Of Soil. 3 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:4:8 ( 1 Cement : 4 Coarse Sand ( Zone-Iii ) : 8 Graded Stone Aggregate 40 Mm Nominal Size ) 4 Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) Complete All As Specified And Directed 5 Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In : Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) Complete All A Specified And Directed. 6 Providing And Laying Autoclaved Aerated Cement Blocks Masonry With 150Mm / 230Mm / 300Mm Thick Aac Blocks In Super Structure Above Plinth Level Upro Floor V Level With Rcc Band At Sill Level And Lintel Level With Appoved Block Laying Polymer Modified Adhesive Mortar All Complete As Per Direction Of Engineer -In-Charge. 7 Half Brick Masonry With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 In Superstructure Above Plinth Level Up To Floor V Level. Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) 8 Providing And Laying Damp Proof Course 40Mm Thick With Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand ( Zone-Iii ) Derived From Natural Sours : 4 Graded Stone Aggregate 12.5 Mm Nominal Size Derived From Natural Sourse Complete All As Specified And Directed. 9 Extra For Providing And Mixing Water Proofing Material In Cement Concrete Work In Doses By Weight Of Cement As Per Manufacturers Specification Complete All As Specified And Directed 10 Extra For Providing And Mixing Water Proofing Matproviding & Applying A Coat Of Residual Petroleum Bitumen Of Grade Of Vg-10 Of Approved Quality Using 1.7Kg Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With Apiece Of Cloth Lightly Soaked In Kerosene Oil Complete All As Specified And Direted. 11 Supply And Stacking 63 To 45 Mm Size Stone Aggregate 12 Laying, Spreading And Compacting Stone Aggregate Of 63 45Mm Size Complete All As Specified And Directed. 13 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level :1:2:4 ( 1 Cement : 2 Coarse Sand ( Zone-Iii ) : 4 Graded Stone Aggregate 40 Mm Nominal Size ) Complete All As Specified And Directed 14 Reinforced Cment Concrete Work In Beam, Suspended Floors, Roofs Having Slope Up To 15 Degree Landings, Balconies, Shelves, Chajjas, Lintels, Bands Plain Window Sills, Staircase And Spriral Stair Case Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 ( 1 Cement : 1.5: 3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Derived From Natural Sourse : 3 Graded Stone Aggregate 20Mm Nominal Size Derived From Natural Sourse ) . 15 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe 500D Or More. Complete All As Specified And Directed 16 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : Suspended Floors, Roofs, Landings, Balconies Complete All As Specified And Directed. 17 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : Lintels, Beams, Plinth Beams, Girders Complete All As Specified And Directed. 18 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : Edges Of Slabs And Breaks In Floors And Under 20Cm Wide Complete All As Specified And Directed. 19 Providing And Fixing Ms Tubular Frames For Doors, Windows Ventlators And Railing With Square / Rectangular / L-Type Sections, , Joints Mitred, Welded And Grinded Finish, With Profile Of Required Size Including Fixing Of Necessary Screws And Applying A Priming Coat Complete All As Specified And Direted. 20 Providing And Fixing Precoated Galvanised Iron Profile Sheets ( Size, Shape And Pitch Of Corrugation As Approved By Engineer-Incharge ) 0.50 Mm ( + 0.05 % ) Total Coated Thickness With Zinc Coating 120 Grams Per Sqm As Per Is: 277, In 240 Mpa Steel Grade, 5-7 Microns Epoxy Primer On Both Side Of The Sheet And Polyester Top Coat 15-18 Microns. Sheet Should Have Protective Guard Film Of 25 Microns Minimum To Avoid Scratches During Transportation And Should Be Supplied In Single Length Upto 12 Metre Or As Desired By Engineerin- Charge. The Sheet Shall Be Fixed Using Self Drilling / Self Tapping Screws Of Size ( 5.5X 55 Mm ) With Epdm Seal, Complete Upto Any Pitch In Horizontal / Vertical Or Curved Surfaces, Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 21 Providing And Laying Ceramic Glazed Floor Tiles Of Size 300X300 Mm ( Thickness To Be Specified By The Manufacturer ) Of 1St Quality Conforming To Is : 15622 Of Approved Make In Colours Such As White, Ivory, Grey, Fume Red Brown, Laid On 20 Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Jointing With Grey Cement Slurry @ 3.3 Kg / Sqm Including Pointing The Joints With White Cement And Matching Pigment Etc., Complete. 22 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 23 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:6 ( 1 Cement: 6 Fine Sand ) 24 20 Mm Cement Plaster Of Mix : 1:4 ( 1 Cement: 4 Fine Sand ) 25 Applying And Finishing Wall With Exterior Weather Coat Paint Of Required Shade With ( Two Or More Coat Applied @ 1.67 Ltr / 10 Sqm ) Over And Including Proming Coat Of Exterier Primer Applied @ 2.2 Kg / 10 Sqm ) ( Apex Ultima ) On Wall Surface Complete All As Specified And Directed By Engr-In-Charge Make : Asian 26 Distempering With 1St Quality Acrylic Distemper ( Ready Mixed ) Having Voc Content Less Than 50 Gms / Litre, Of Approved Manufacturer, Of Required Shade And Colour Complete, As Per Manufacturer’S Specification. Two Or More Coats On New Work 27 Applying Priming Coat: With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Work ( Second Coat ) 28 Providing And Fixing In Repairs White Vitreous China Pedestal Type Water Closet ( European Type W.C. Pan ) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device ( Handle Lever ) , Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required : W.C. Pan With Isi Marked White Solid Plastic Seat And Lid 29 Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm Dia Cp Brass Single Hole Basin Mixer Of Approved Quality And Make, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Required:- White Vitreous China Wash Basin Size 550X400 Mm With A 15 Mm Cp Brass Single Hole Basin Mixer 30 Providing And Fixing White Vitreous China Pedestal For Wash Basin Completely Recessed At The Back For The Reception Of Pipes And Fittings. 31 Providing And Fixing 8 Mm Dia C.P. / S.S. Jet With Flexible Tube Upto1 Metre Long With S.S. Triangular Plate To Eureopean Type W.C. Of Quality And Make As Approved By Engineer - In - Charge. 32 Providing And Fixing Cp Brass Single Lever Telephonic Wall Mixer Of Quality & Make As Approved By Engineer In Charge. 15 Mm Nominal Dia 33 Providing And Fixing P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete 32 Mm Dia 34 Providing And Fixing 600X450 Mm Beveled Edge Mirror Of Superior Glass ( Of Approved Quality ) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. 35 Providing And Fixing Toilet Paper Holder : C.P. Brass Complete All As Specified And Directed. 36 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge.20Mm Nominal Outer Dia Pipes 37 Providing And Fixing G.I. Tee 50X25mm As Per Isi Marked Complete All As Specified And Directed. 38 Providing And Fixing 15 Mm Nominal Bore Cp Brass Bib Cock Of Approved Quality Conforming To Is : 8931Complete All As Specified And Directed. 39 Providing And Fixing In Repairs15mm Nominal Bore Cp Brass Angle Valve Od Approved Quality Conforming To Is: 8931 Complete All As Specified And Directed. 40 Providing And Fixing Uplasticised Pvc Connection Pipe With Brass Unions : 30 Cm Length 15 Mm Nominal Bore 41 Providing And Fixing C.P. Brass Shower Rose With 15 Or 20 Mm Inlet : 100 Mm Diameter Complete All As Specified And Directed 42 Constructing Masonry Chamber 30X30x50 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) For Stop Cock, With C. I.Surface Box 100X100 X75 Mm ( Inside ) With Hinged Cover Fixed In Cement Concrete Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1Cement : 3 Coarse Sand ) 12Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 43 Providing And Fixing In Repairs Ptmt Towel Rail 600Mm Long Complete With Brackets Fixed To Wooden Cleats, Cp Brass Screws With Concealed Fitting Arrangement Of Approved Quaility Complete All As Specified And Directed. 44 Painting With Synthetic Enamel Paint To Steel Surface Of Approved Brand And To Give And Even Shade Two Or More Coats Over A Coat Of Primer On New Work Complete All As Specified 45 Providing And Fixing 15 Mm Nominal Bore Ptmt Pillar Cock Of Approved Quality And Colour, 107 Mm Long, Weighing Not Less Than 110 Gms All As Specified And Directed. 46 Providing And Fixing Factory Made Pvc Solid Door Frame Of Size 90X50mm Wpc Solid Door Frme With 1000 Kg / Cum Density, Uniform Structure, Symmetrical Dimension, Consistent Quality, Equivalent To Natural Wood, Virgin Polymers With Higher Natural Fibre Contents. The Door Frame To Be Fixed To The Wall Using Ms, Screws Of Of Suitable Size , Complete As Per Manifactutrts Specification And As Directed By Engineer-In-Charge. 47 Providing And Fixing Factory Made Panel 30 Mm Thick Pre Laminated Pvc Door Shutter Consisting Of Frame Made Out Of Ms Tubes Of 19 Gauge Thickness And Size Of 19Mmx19mm For Style And 15X15mm For Tp& Bottom Rails. Ms Frame Shall Have A Coat Of Steel Primers Of Approved Make And Manufacture.Ms Frame Covered With 5Mm Thick Heat Moulded Pvc C Channel Of Size 30Mm Thickness, 70Mm Width Out Of Which 50Mm Shall Be Flat And 20Mm Shall Be Tapered I 45 Degree Angle On Both Side Forming Styles And 5Mm Thick, 95Mm Wide Pvc Sheet Out Of Which 75Mm Shall Be Flat And 20Mm Shall Be Tapered In 45 Ddegree On The Inner Side Forming Styles And 5 Mm Thick, 95Mm Wide Pvc Sheet Out Of Which 75Mm Shall Be Flat And 20Mm Shall Be Tapered In 45 Degree On The Inner Side O Form Top And Bottom Rail And 115Mm Wie Pvc Sheet Out Of Which 75Mm Shall Be Flat And 20Mm Shall Tapered On Both Sides To Form Lock Rail. Tpop, Bottom And Lock Rails Shall Be Provided Both Side Of The Panel.10Mm ( 5Mm X2 ) Thick, 20Mm Wide Cross Pvc Sheet Be Provided As Gap Insert For Top Rail & Bottom Rail, Paneling Of 5Mm Thick Both Side Pvc Shett To Be Fitted In The Ms Frame Welded / Sealed To The Styles & Rails With 7Mm ( 5Mm+2Mm ) Thickx15mm Wide Pvc Sheet Beading On Inner Side, And Joined Together With Solvent Cement Adhesive. An Additional 5Mm Thick Pvc Strip Of 20Mm With Is To Be Stuck On The Interior Side Of The C Chaneel Using Pvc Solvent Adhesive Etc Etc, Complete As Per Direction Of Engineer-In-Charge, Manufacturers Specification & Drawing 48 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, Single Socketed Pipes. 75Mm Diameter 49 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, Single Socketed Pipes. 110 Mm Diameter 50 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion. Single Tee With Door 75X75x75 Mm 51 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion. Single Tee With Door 110X110x110 Mm 52 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion. Single Tee Without Door 75X75x75 Mm 53 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion. Bend 87.5°-75 Mm Bend 54 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion. Bend 87.5°-110 Mm Bend 55 Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50x50 Mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length, Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete.75 Mm 56 Providing And Fixing Unplasticised -Pvc Pipe Clips Of Approved Design To Unplasticised - Pvc Rain Water Pipes By Means Of 50X50x50 Mm Hard Wood Plugs, Screwed With M.S. Screws Of Required Length, Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete. 110 Mm 57 Providing And Applying White Cement Based Water Proof Putty Of Average Thickness 1Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete 58 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface Complete All As Specified And Directed. 59 Providing And Fixing 600X120x5mm Glass Shelf With Edges Round Off, Supported On Anodised Aluminium Angle Frame With Cp Brass Brackets And Guard Rail Complete Fixed With 40Mm Long Screws, Rawl Plugs Etc Complete 60 Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Makeconforming To Is: 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling Nd Dash Fasteners To Be Paid For Separately ) :For Fixed Portion Anodised Aluminium ( Anodised Transparent Or Dyed To Required Shade According To Is: 1868, Minimum Anodic Coating Of Grade Ac15 ) 61 Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer-In-Charge . ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item ) : With Float Glass Panes Of 5 Mm Thickness ( Weight Not Less Than 12.50 Kg / Sqm ) 62 Providing An Fixing Nahani Trap Complete As Per Site Requirement And As Specified And Direted By Engr -In-Charge. 63 Providing And Fixing Ptmt Liquid Soap Container 109 Mm Wide, 125Mm High And 112Mm Distance From Wall Of Standard Shape With Br Of The Same Materials With Snap Fittings Of Approved Quality And Colour, Weighing Not Less Than 105Gms. 64 Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate ) Finished With A Floating Coat Of Neat Cement, Including Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete. 40 Mm Thick With 20 Mm Nominal Size Stone Aggregate 65 Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath &Courtyard, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles, Including Rubbing And Cleaning Etc. Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) . Dark Shade Pigment Using Ordinary Cement 66 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix : 1:6 ( 1 Cement: 6 Fine Sand ) 67 20 Mm Cement Plaster Of Mix : 1:4 ( 1 Cement: 4 Fine Sand ) 68 Applying And Finishing Wall With Exterior Weather Coat Paint Of Required Shade With ( Two Or More Coat Applied @ 1.67 Ltr / 10 Sqm ) Over And Including Proming Coat Of Exterier Primer Applied @ 2.2 Kg / 10 Sqm ) ( Apex Ultima ) On Wall Surface Complete All As Specified And Directed By Engr-In-Charge Make : Asian 69 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge.25Mm Nominal Outer Dia Pipes 70 Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer In Charge.20Mm Nominal Outer Dia Pipes 71 Providing And Applying White Cement Based Water Proof Putty Of Average Thickness 1Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 72 Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface Complete All As Specified And Directed. 73 Excavation Holes More Than 0.10 Cum & Upto 0.50 Cum Including Getting Out The Excavated Soil, Then Returning The Soil As Required Layers In All Kind Of Soil. 74 Providing And Laying In Position Cement Concrete Of1:2:4 ( 1 Cement:2 Coarse Sand :4Graded Stone Afggregate ) In Post Holes 75 Stuctural Steel Work In Single Section, Fixed With Or Withot Connecting Plate, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete 76 Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflow Pipes But Without Fittings And The Base Support For Tank. 77 Providing And Fixing 20Mm Nominal Bore Ptmt Ball Cock Of Approved Quality, Colour And Make Complete With Epoxy Coated Aluminium Rod With Lp / Hphd Plastic Ball, 120Mm Long Weighing Not Less Than 198 Gms Complete All As Specified And Directed.

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail