| 1 | Demolition and breaking up drain pipe (SGSW) set in cement mortar of 150mm bore complete all as specified and directed including PCC benching complete all as specified and as directed. |
| 2 | Demolition and breaking up drain pipe (SGSW) set in cement mortar of 100mm bore complete all as specified and directed including PCC benching complete all as specified and as directed. |
| 3 | S&F PVC (SWR) pipes160 mm bore single socketed, in any length with rubber ring joints, laid in trenches, wall or in floors. |
| 4 | S&F PVC (SWR) pipes110 mm bore single socketed, in any length with rubber ring joints, laid in trenches,wall or in floors. |
| 5 | S&F in repair PVC (SWR) pipes 75 mm bore single socketed, in any length with rubber ring joints, laid in trenches,wall or in floors. |
| 6 | S&F in repairPVC bends any radius 110mm bore |
| 7 | S&F in repairPVC bends any radius 75mm bore |
| 8 | Excavation in trenches n,exc 1.5 m wide and n.exc 1.5 m deep for foundation and getting out in any type of soil. |
| 9 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point |
| 10 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. |
| 11 | M&L cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) to bed of drain pipes including packing under and haunching against the sides of pipes, after they are laid and tested for 160 mm bore pipe complete all as specified and directed |
| 12 | M&L cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) to bed of drain pipes including packing under and haunching against the sides of pipes, after they are laid and tested for 110 mm bore pipe complete all as specified and directed |
| 13 | Cleaning of bloackage EWC/IWC/urinal/bathroom & kitchen, including gully trap, nahani trap & removing of sludge/spoil/waste to a distance exc 100mtr & testing for proper working after cleaning complete all as specified and directed. |
| 14 | Cleaning of SGSW/PVC/AC/CI pipe line 100/110/150/160 mm bore size by roding or by pressure pump completely excludingconnected manhole , any depth & removal of sludge etc to a distance as specified under particular specification Note : Cleaning of man holes between sewage lines are included in the item, nothing extra will be paid on tic account) |
| 15 | Dewatering of Septic tank soakage well and manhole of any depth in any position by pumping out and removing outside Military/Defence land by mechanical means (trolley mounted) and burying in pits all as directed including digging of pits in any type of soil and covering pits with earth after absorption of water and including providing and spreading required quantity of bleaching powder around the pit or dispose of waste material as per state protocol and washing the top of septic tank & soakage wells and surrounds with fresh water and sprinkling lime to make hygeinic complete all as specified and directed by Engr - in Charge. |
| 16 | De-sludging of septic tank of any capacity including connected intercepting chamber, manhole shaft, sludge chamber & filterbeds of any description and in anmy position by pumping out and removing of sludgeoutside Military/ Defence land by mechanical means (trolly mounted) and burying in pits all as directed including digging of pits in any type of soil and covering pits with earth after filling of sludge and including providing and spearding required qty of bleaching powder or dispose of waste material complete as per state protocol,including taking down of slab cover and placing the same in existing postion complete all as specified and directed by Engineer-in-Charge. |
| 17 | Demolition of brick work or solid block /stone boulder masonry, built CM including all quoins, pillars etc. |
| 18 | Material and labour for providing precast cement concrete block masonry 1:3:6 type-C1(using 20mm graded crushed stone aggregate) solid blocks exceeding 10cm in width and set in cement mortar (1:4) complete all as specified and directed. |
| 19 | Demolition of precast reinforcement cement concretein ground floor and paving n.exc 15cm thickness (below or above ground level). |
| 20 | M&L precast cement concrete type B1, 1:2: 4 ( using 20mmgraded stoneaggregate) incover slab for manhole and similar articles with plain faces and set in CM 1:6. |
| 21 | S&F Mild steel TMT bars 8 mm dia and over, cut to length,bent to shape required, including cranking, bending spirally for hooping ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips(TMT) |
| 22 | Taking down of cement plaster of any description on brick including raking out joints,hacking for key,scrubbing down with water etc.complete all as specified and directed. |
| 23 | M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 and finished the surface even and smooth without using extra cement. |
| 24 | Demolition of cement concrete infloors n.exc 15 cm thick in ground floor (below or aboveground level all as specified |
| 25 | M&L PCC 1:4:8 type D2(using 40mm graded aggregate)as in foundation filling and mass concrete etc. |
| 26 | M&L for PCC 1:2:4 type B-1 (using 20 mm graded curshed storne agg) as in coping/bunching and similar work complete all as specified and directed. |
| 27 | Dismantling of floor hearth or wall tilling including cement mortar bedding but not backing , removing serviceable tiles to store and rubbish off the premise complete all as specified and directed. |
| 28 | M&L for glazed ceramic coloured tiles 200x300x5to6mm thick as in dado over and including 10mm thick rendering in CM (1:4) and set and ointed in neat cement slurry and pointed with white cement complete all as spfd and directed. |
| 29 | M&L joint free non skid ceramic coloured tiles 7-8mm thick (square/rectangular) area of each tile exc 0.06 Sqm but not exc 0.11 Sqm, over and including 15mm thick screed bed in Cement mortar (1:6)in flooring, set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed. |
| 30 | S&F in repairs vitreous china Orissa pattern size 580mm x440mm white with ‘P’ or ‘S’ trap front or back inlet and foot rest any pattern complete all as specified and directed. |
| 31 | S&F in repair Vitreous china wash down water closet pan (Pedestal pattern) with matching seat cover, excluding fixing bolts, flushing cister and flush pipe completeall as specified |
| 32 | S&F in repair vitreous china wash hand basin white flat back of size 550mmx400mm including bracketscomplete all as specified and directed NOTE :- The entire contract shall be operated for the period of 09 months from the date of acceptance. The work shall be executed on the requirement basis as directed by Eng-in-charge during currency of contract. It will be the responsibility of contractor to maintain the sewage system functional throughout contract periods irrespective of value of work that may be ordered during the period of contract.The contractor or his authorised representative shall report to Engineer-in-charge (or the person deputed by him) at 900 hours daily to receive the complaints pertaining to cleaning of sewage lines. The Engineer-in-charge will issue Job Card to attend the complaints and the Job Card shall be returned by the contractor to the Engineer-in-charge on the given date and time after attending the complaints. The Job Card should bear user?s signature of satisfactory completion of complaints. In case contractor or his authorised representative fails to report to Engineer-in-charge at 900 hours daily to receive the complaints pertaining to cleaning of sewage lines, the contractor shall be liable to pay the penalty @ Rs 1500/- per day and similarly he fails to attend the complaints pertaining to cleaning of sewage lines, the contractor shall be liable to pay the penalty @ Rs 500/- per day per complaint. In case of any dispute regarding imposition of penalty, the decision of Accepting Officer shall be final and binding. |