| 1 | Supplying, laying GI water tubing, medium grade ISI marked, of 50mm bore confirming to IS-1239 [Part-1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, nipple, union etc laid in trenches / floors or fixed to walls / ceiling / roof etc including testing for leakage, rectifing etc complete all as specified and as directed by Engineer-in-Charge. |
| 2 | Supplying, laying GI water tubing, medium grade ISI marked of 25mm bore confirming to IS-1239 [Part-1] including all fittings such as bends, tees, short pieces, connectors, elbows, reducers, nipple, union etc laid in trenches / floors or fixed to walls / ceiling / roof etc including testing leakage, rectifing etc complete all as specified and as directed by Engineer-in-Charge. |
| 3 | Supply and fix Gun Metal, globe or gate valves ISI marked with iron wheel head screwed both ends for iron pipe and fixed of 50mm bore complete all as directed by Engineer-in-Charge. |
| 4 | Supply and fix Gun Metal, globe or gate valves ISI marked with iron wheel head screwed both ends for iron pipe and fixed of 25mm bore complete all as directed by Engineer-in-Charge. |
| 5 | S&F Rotational moulded polyetheylene (HDPE) 1000 ltr Water Tanks, Double layered ISI marked Cylindrical & Vertical Type, double layered,with 25mm bore tank nipple, ISI marked, hoisted and fixed in position including provision of 50mm / 25mm dia spouts for connecting inlet, outlet, over flow and washout pipes complete as directed by Engineer-in-Charge. |
| 6 | Supply and fix 25mm Ball brass valves,high pressure,with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed of bore complete all as directed by Engineer-in-Charge. |
| 7 | Material and labour for cutting existing GI/DI/CI pipe line of dia upto 150 mm bore and making connection for new 50 mm boreGI pipe including necessary connections, fittings complete all as specified and as directed by Engineer-in-Charge |
| 8 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil complete by Engineer-in-Charge. |
| 9 | M&L for hard core of gauge n.exc. 63mm deposited spread and levelled in layers n.exc. 15 cm thick watered and rolled / rammed to a true surface complete all as specified and as directed by Engineer-in-Charge |
| 10 | M&L for Plain Cement concrete type D2 1:4:8 nominal mix (using 40 mm graded stone aggregate) in foundations, filling and mass concrete including formwork complete all as specified and as directed by Engineer-in-Charge |
| 11 | M&L for sand filling under floors or in foundationincluding watering and consolidation complete all as specified and as directed by Engineer-in-Charge |
| 12 | M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade with grey cement and pigment including kerb stone complete all as specified and as directed by Engineer-in-Charge |
| 13 | Excavation in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-Charge |
| 14 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed by Engineer-in-Charge |
| 15 | Removing excavated material n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge |
| 16 | M&L precast cement concrete block masonry with solid block, exc 10cm in width in PCCtype C-1, 1:3:6 (using 20mm graded stone aggregate) set in CM (1:4) complete all as specified and as directed by Engineer-in-Charge |
| 17 | M&L for Rendering 15mm thick in concrete/masonry surfaces CM 1:4 finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge |
| 18 | M & L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed by Engineer-in-Charge. |
| 19 | Demolition of Reinforced Cement Concrete [reinforcement cut as required to facilitate demolition] of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engineer-in-Charge |
| 20 | Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Engineer-in-Charge |
| 21 | Demolition of precast concrete block walling built in Cement Mortar including all quoins arches pillars etc complete all as specified and as directed by Engineer-in-Charge |
| 22 | M&L for dismantling fencing wiremesh any type complete all as specified and as directed by Engineer-in-Charge |
| 23 | Dismantlingposts or struts (steel or RCC) embedded in concrete, any section, including taking out embedded portion and making good the disturbed surface complete all as specified and as directed by Engineer-in-Charge |
| 24 | M & L for providing plain cement concrete1:3:6, type nominal mix C 2 (using 40 mm graded stone aggregate) as in surface channel and drains including formwork etc complete all as specified and as directed by Engineer-in-Charge |
| 25 | M & L for Cement plaster Setting coat 3mm thick, CM 1:2 trowelled to even and smooth finish complete all as specified and as directed by Engineer-in-Charge |
| 26 | S&F 150mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed by Engineer-in-Charge |
| 27 | M&L for concrete bed (1:3:6) Type C2 to drain pipes including packing under and haunching against the sides of pipes after are laid and tested in 150mm dia pipe including formwork complete all as specified and as directed by Engineer-in-Charge |
| 28 | M&L for Providing, Precast RCC type B1 1:2:4 (using 20mm graded stone aggregate) in covers slabs over Manholes/drains including necessary formwork etc , set in cement mortar 1:4 complete all as specified and as directed by Engineer-in-Charge (Note: reinforcement shall be measured & paid separately) |
| 29 | M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer-in-Charge. |
| 30 | M & L for Cutting into existing manholes for connecting new drains size 150mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and as directed by Engineer-in-Charge. |
| 31 | Supplying fixing testing and installation of LLDPE septic tank designed to carry sewage & sullage water and waste of 25 users as per manufacture instruction complete all as specified and directed by Engineer-in-Charge.Make: United Polymers Cat Part No.750X2500 mm 1300 Ltr |
| 32 | Design, Manufacture, Supply, Installation, Testing & Commissioning of 11 KV / 0.415 KV, 500 KVA factory assembled, factory tested ready to install and connections typeCompact Sub Station with an outdoor enclosure consisting of the following items:(i) HT Switchgear: 11 KV, 630 Amps, 21 KA for 3 sec, SF6 insulated Non-Extensible RMU / compact switchgear consisting of 1 way RMU with 01 No riser module for direct cable connection and 01 No fixed Mannual VCB copper bus bar in SF6 insulated robotically welded stainless steel enclosure with degree of protection IP 67, manual spring charging, capacitive volateg presence indicator, operating mechanisms with integral mechanical interlocks, switch position indication,manometer for SF6 pressure monitoring with series trip, self powered microprocessor based numerical protection over current relay (IDMTL + Inst) protection. Protection CT of ratio 40/1 A of class 5P10 with minimum burden 2.5 VA. Item No.32.00 Contd.../- |
| 33 | (ii) Transformer: 500 KVA, 11KV/433V, Dyn11, 3 phase, 50 Hz, Dry cast resin with out enclosure type, copper wound, step down transformer with primary delta connected and secondary star connected, with off load tap changer links on HT side of tapping range of +5 % to -5% in step of 2.5% having insulation class F, temparature rise in winding will be 90degree C (Max).The losses shall be as per IS: 11171, percentage impedance of transformer shall not be less than 4.5% with winding temparature indicator with alarm & trip contacts.(iii) LT Panel:415 Volts, LT panel board double door CPRI approved of suitable size for 3 phase 415 volts of suitable size with bus bar of rating 1.25 times of rated incomer capacity (100% for phase & 50% for neutral) and made out of 2.00 mm thick CRCA sheet compartmentalised complete with internal wiring to accommodate the following: Item No.32.00 Contd.../- |
| 34 | Incomer:(a) ACB 800 Amps, 415 volts, 4P, 50 KA, 3 phase, 50 HZ electrical drawout type,microprocessor based release with overload, short circuit & in built earth fault protection and having short circuit capacities as Icu=Ics= 100% Icw for 1 sec (01 No).(b) LT metering CT of ratio 800/5 A, accuracy class CL-1.0 -01 Set(c) LED phase indication lamps for RYB phases, ACB on, off and trip - 01 Set (d) Digital voltmeter with range (0-500) V - 01 No and digital ammeter with range (0-1000) A - 01 No(e) Digital Multifunction Meter with A, V, KW, KWH, PF, class - 1.0 with port - 01 No Outgoing:(a) 250 Amps, 415 Volts, 4P, 25 KA thermal magnetic based release MCCB with overload and short circuit protection - 03 Nos Item No.32.00 Contd..../- |
| 35 | (iv) Outdoor Enclosure:Outdoor type Galvanised enclosure having modular construction with 3.15 mm thick Galvanised sheet steel in corrugated / Louvered design type wall design for better heat dissipation and providing robust construction. The degree of protection for HT & LT switchgear compartment shall be IP 54 & degree of protection for transformer compartment of the enclosure shall be minimum IP 34. Each compartment shall be provided with door and pad locking arrangement. Doors of transformer compartment are fitted with Arc reflectors from the inside for providing better safety. The compartment illumination lamp with door operated switch shall be provided for each compartment. Structure of the CSS shall be able to withstand the gross weight of all equipments. The CSS shall be provided with lifting beams and hooks for easy installation at site and it shall be possible to transport the equipment along with transformer, RMU, LT panel from one site to another. The enclosure exterior shall be painted with polyurethane paint / epoxy powder coated and tropicalised to Indian weather conditions.Item No.32.00 Contd.../- |
| 36 | (v) Interconnection & Earthing:Interconnection between RMU and Transformer using 11 KV (UE) 3C x 95 Sqmm, HT XLPE AL armoured cable & interconnection between transformer and LT switchgear using AL busbar of suitable size for carrying full load Transformer rated current & Internal earthing connections by using 50 x 6 mm AL bus strip.Note:(i) Interconnecting HT cable end termination kits deemed to be included in the quoted rate.(ii) Final Drawings (GA drawing, Power & Control wiring drawings) & Technical data sheet of Transformer, HV/LV switchgear, relay etc shall be submitted to GE for approval before placing the order. (iii) Compact Substation shall be outdoor plinth mounted type. The foundation for the CSS should be as per manufacturers recommendation / specifications. The foundation drawing for the same should be got approved by GE. The rate for the CSS foundation shall be measured and paid seperately.(iv) CSS shall be complete with internal connections and extending of earth bar of neutral body terminals to the frame of the CSS to earth pits. |
| 37 | Disconnecting the existing transformer of CT Scan of HT/ LT electrical connections of transformer terminals and shifting the transformer of capacity 250KVA from existing position to another location at INHS Dhanvantari and reinstalling the samein position including necessary testing after reinstalling the transformer complete all as specified and as directed. Note :- (i) Distance of Transformer shifting from existing position to another location at INHS Dhanvantari. |
| 38 | Dismantling and taking down all fitting fixture carefully the existing 2- pole structure and refixing the same in Power House complete all as specified and as directed by Engineer-in-Charge |
| 39 | M&L for steel tubular swaged poles type 410 SP-55 11 meter long complete with cast iron base plate, final taper plug, bolts, nuts & screws all as specified and directed complete all as specified and as directed by Engineer in Charge. Note: Earth work and PCC work in foundation / pole coping will be measured and paid seperately under relevant items. |
| 40 | Material and labour for cross arms, bracing, supports, clamps and back plate fabricated from structural MS section for gateincludingnuts, bolts, washers, welding, bending, cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of complete all as specified and as directed by Engineer-in -charge. |
| 41 | Supply and fix HT 11 KV out door type triple pole, gang operated air-break switch suitable for horizontal or vertical mounting rotating type complete for current rating upto 400 Amps complete all as specified and as directed by Engineer-in -charge. |
| 42 | Supply and fix pin type, composite silicon rubber polymeric type insulator 150 mm height, 150 mm dia for 11000 Volts grade, 5 KN with ECR glass rod, forged steel top and bottom, silicon rubber housing and weather sheds, including one galvanized mild steel spindle, galvanized iron washer, spring and one galvanized iron nut complete all as specified and as directed by Engineer-in -charge. |
| 43 | Supply and fix single phase drop out fuse 12KV, 400 Amps rating with single silicon rubber polymeric insulator complete all as specified and as directed by Engineer-in -charge. |
| 44 | Supply and install Lighting arrestors High Tension expulsion type complete with all fittings, Transmission class, discharge capacity 65 Kilo amp suitable for 11000 Volts self supporting station class type complete including taking down existing lighting arrestor complete all as specified and as directed by Engineer-in-Charge |
| 45 | Material and labour for earthingwith copper earth plate electrode 600 mm x 600 mm x 3.00 mm thick, (3.15) burried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to copper strip of size 20 x 3 mm as earthing leadmeans of copper brazing made out of galvanised iron mild steel and 40 mm dia GI pipe \"light grade\" for protection of earth lead and connected to contoll board or main switch or as directed by Engr -in-Charge including earthing pit in PCC (1:3:6) type C-1, RCC 1:1.5:3 cover slabof required size with one handle made out of 8 mm dia round bar 20 mm dia GI pipe light grade for watering funnels , wire mesh and provided charcoal or coke of alternative layers of 15 cm including necessary earth work complete shown in electrical plated No 3 and tesingcomplete all as specified and as directed by Engineer-in-ChargeNote : (i) The earthing pit should be provided with proper earth pit and pit cover. (ii) If the desired earth resistance is not achieved during testing as per IS the complete earthing shall be replaced out by the contractor at his own cost and no extra claim shall be admissable. |
| 46 | M & L for PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in coping of poles including formwork complete all as specified and as directed by Engineer-in-Charge. |
| 47 | M&L for road cutting, removing of excavated material, returning filling with PCC 1:2:4 for laying of LT UG cable /Galvanised Iron Pipe/Rex Pipe complete complete all as specified and as directed by Engineer-in-Charge |
| 48 | Supply , laying and testing HT UG cable XLPE cable of size 3 core 95 Sqmm insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable ( Heavy duty) with Aluminium conductor 11000 volts grade cross sectional area complete all as specified and as directed by Engineer-in-Charge |
| 49 | Supply & Laying of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 50mm and inner dia 38 mm polythylene including coupler & Bend with smoooth inernal and profiled external surface for non pressue under ground cable complete all as specified and as directed by Engineer-in-Charge |
| 50 | Supply & Laying of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 63mm and inner dia 50 mm polythylene including coupler & Bend with smoooth inernal and profiled external surface for non pressue under ground cable complete all as specified and as directed by Engineer-in-Charge. |
| 51 | Supply & Laying of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 120 mm and inner dia 103 mm polythylene including coupler & Bend with smoooth inernal and profiled external surface for non pressue under ground cable complete all as specified and as directed by Engineer-in-Charge |
| 52 | S & F for cable jointing kit for 1100Voltgrade cable for Straight through, cold shrinkabletype joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 10 to 16 Sqmm 3.5 core as in repairs complete all as specified and as directed by Engineer-in -charge. |
| 53 | S & F for cable jointing kit for 1100Voltgrade cable for Straight through, cold shrinkabletype joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 25 to 50 Sqmm 3.5 core as in repairs complete all as specified and as directed by Engineer-in -charge. |
| 54 | S & F for cable jointing kit for 1100Voltgrade cable for Straight through, cold shrinkabletype joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 70 to 150 Sqmm 3.5 core as in repairs complete all as specified and as directed by Engineer-in -charge. |
| 55 | S & F for cable jointing kit for 1100Voltgrade cable for Straight through,cold shrinkabletype joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 185 to 240 Sqmm 3.5 Core as in repairs complete all as specified and as directed by Engineer-in -charge. |
| 56 | S & F for cable jointing kit for 1100Voltgrade cable for Straight through, cold shrinkabletype joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 300 to 400 Sqmm 3.5 Core as in repairs complete all as specified and as directed by Engineer-in -charge. |
| 57 | S&F cable jointing and testing outdoor type cable end termination cold shrinkable end typejoint for 3 core 11KV 70 to 120 Sqmm complete all as specified and as directed by Engineer-in-Charge. |
| 58 | S&F cable jointing and testing outdoor type cable straight through termination cold shrinkablejoint for 3 core 11KV 50 to 95 Sqmm complete all as specified and as directed by Engineer-in-Charge. |
| 59 | Supply and fix cable jointing kit for 11 KV grade cable for indoor end termination,cold shrink type, joint complete with jointing material and accessories suitable for3 core XLPE, armoured, Al conductor cable of size 70 sqmm to 120 sqmm complete all as specified and as directed by Engineer-in-Charge |
| 60 | Suppy and laying testing and commissioning PVC insulated, PVC sheathed, galvanised steel strip or wire armoured electric power cables with stranded aluminium conductors 1100 Volts grade laid in trenches, fixed on walls pasing through pipes complete all as specified and as directed by Engineer-in-Chargefor the following size :-Note:The rates shall be include necessary Cable lugs, Cable Gland and joint kit (if required) in the subject item. |
| 61 | (a) 4 Core 16 Sqmm |
| 62 | (b) 3.5 Core 25 Sqmm |
| 63 | (c) 3.5 Core 50 Sqmm |
| 64 | (d)3.5 Core 70 Sqmm |
| 65 | (e) 3.5 Core 95 Sqmm |
| 66 | (f) 3.5 Core 120 Sqmm |
| 67 | (g) 3.5 Core 240 Sqmm |
| 68 | (h) 3.5Core 400Sqmm |
| 69 | M&L for cable route indicator made of cast aluminium disc 200mm dia, with inscription of HT cable fixed to MS angle of size 40x40x6mm, 600mm long with bolts & nuts, duly grouted in PCC 1:3:6, type C2 complete including necessary excavation and earth work including taking up existing indicators complete all as specified and as directed by Engineer-in-Charge |
| 70 | M&L for relaying of serviceable existing HT cable of size 95 sqmmtaking down , laid in trenches / duct with DWC pipe and suitable GI pole including necessary fixing arrengement such as road and soil etccomplete all as specified and as directed by Engineer-in-ChargeNote : excavation and earth work shall be measured and paid seperately. |
| 71 | M&L for relaying of serviceable existing LT cable of size 10 to 50 sqmm taking down , laid in trenches / duct with DWC pipe and suitable GI pole including necessary fixing arrengement such as road and soil etccomplete all as specified and as directed by Engineer-in-Charge.Note : excavation and earth work shall be measured and paid seperately. |
| 72 | M&L for relaying of serviceable existing LT cable of size 70 to 95 sqmm taking down , laid in trenches / duct with DWC pipe and suitable GI pole including necessary fixing arrengement such as road and soil etccomplete all as specified and as directed by Engineer-in-ChargeNote : excavation and earth work shall be measured and paid seperately. |
| 73 | M&L for relaying of serviceable existing LT cable of size 120 to 400sqmm taking down , laid in trenches / duct with DWC pipe and suitable GI pole including necessary fixing arrengement such as road and soil etccomplete all as specified and as directed by Engineer-in-Charge.Note : excavation and earth work shall be measured and paid seperately. |