Tender For Repair To Internal Electrification Including Meters Ceiling Fan Geyser And External Electrification Including Fps Dbs Lt Panel Cable Street Light And Apfc At Akash Vihar Under Ge Af Marathahalli, marathahalli-Karnataka

Military Engineer Services-MES has published Tender For Repair To Internal Electrification Including Meters Ceiling Fan Geyser And External Electrification Including Fps Dbs Lt Panel Cable Street Light And Apfc At Akash Vihar Under Ge Af Marathahalli. Submission Date for this Tender is 30-11-2022. Electrification Work Tenders in marathahalli Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

34542117
Corrigendum : Tender For Repair To Internal Electrification Including Meters Ceiling Fan Geyser And External Electrification Including Fps Dbs Lt Panel Cable Street Light And Apfc At Akash Vihar Under Ge Af Marathahalli
Open Tender
Indian
Karnataka
marathahalli
30-11-2022

Tender Details

Repair To Internal Electrification Including Meters Ceiling Fan Geyser And External Electrification Including Fps Dbs Lt Panel Cable Street Light And Apfc At Akash Vihar Under Ge Af Marathahalli

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 07-Nov-2022 DATE POSTPONEMENT CORRIGENDUM Date 23-11-2022
2 10-Nov-2022 BOQ CORRIGENDUM_2 BOQ 23-11-2022
3 10-Nov-2022 OTHER CORRIGENDUM3 Other 23-11-2022
4 23-Nov-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 30-11-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 39800.0 /-
Tender Value
INR 19.90 Lakhs /-

BOQ Items

Name of Work: REPAIR TO INTERNAL ELECTRIFICATIONINCLUDING METERS, CEILING FAN, GEYSER AND EXTERNAL ELECTRIFICATION INCLUDING FP"S, DB"S, LT PANEL, CABLE, STREET LIGHT AND APFC AT AKASH VIHAR UNDER GE(AF) MARATHAHALLI
Sl. No. Item Description
1Taking down unserviceable wire carefully copper/ aluminum point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, regulators, sockets, light fittings, fans etc., and making good the disturbed surfaces of walls, ceiling etc., including painting with same colour of the background, complete all as specified and as directed.
2Wiring complete with 1.5 Sqmm single core FRLSPVC insulated unsheathed cable 1100 volts grade multi stranded with copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit incl accessories surface type run on walls/ ceiling incl MS terminal boxesmounted concealed on walls with hylon laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket andoutlets, fan regulators etc., incl provision of 1.5 Sqmm FRLS PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. (a)One Light point controlled by one switch
3(b)One fan/Ex. fan point controlled by one switch.
4(c)One 5A 2pin/3pin switch socket out let multipurpose on independent Board.
5(d)One call bell point controlled by one bell push
6All as per item No -02 above but wiring complete with 2.5Sqmm for 5 pin 5/15A socket multipurpose on independent board. Note:- Item No2.00 to 3.00 (i) The earth wire for the points shall be laidfrom the respective switch board only . (ii) Earth wire shall be taken inside the conduit. (iii)Cost of terminal box is deemed to be included in the item rate quoted for point wiring
7S & FSwitch piano flush type, single pole, one way5 Amps.
8S & F Switch socket combination 2 -in-1, 3 pin/5 pin, 5 Amps 230 volts.
9S & FSwitch Socket Combination 2 in 1, 3 pin 5 Amps and 15 Amps flush type , 230 volts .
10S & Fstep type electronic fanregulator, - 2 module.
11S& F PVC ceiling rosetwo to threeterminalsall as specified.
12S & Fding dong bell AC, 230 volts, single pole complete.
13S & F Socket outlet 2 in 1, 3 pin, 5A Flush type 230 volts.
14S & F Socket Outlet 2 in 1, 3 pin, 5 and 15 amp flush type 230 volts
15S & FSwitch Piano Flush type, Single pole, One way 230 volts 15 / 16 Amps
16S&FAngle holder PVC/polycarbonate type all as specified and as directed
17Supply and fixing 600x600mm surface/ recessed mounted LEDLight fitting 36 /35 W,glare freeuniform illuminationacrylic diffuser,connector block etc., complete with all accessoriesand including connecting up with 3 core 0.5sqmm copper wire between ceiling rose and fitting terminal complete all as specified and as directed.
18Supply and FixingLED Tube light fitting 1 x20 W,220VCRCAhousing withPC diffuserbox type with driver,holder including LED tube light connecting upwith 3 core 0.5sqmm copper wire between ceiling rose and fitting terminal all as specified and as directed.
19Supply and fixing LED light fitting mirror type high out put diffuser 2 feet 10 W 220 V AC recessed/surfaced type high efficieny with drivers, holders LED lamp including connecting up with three core flexible copper conductor cable of suitable size
20Supply and fix LED light fittings 1X9/1X10 bulkhead luminaries including LED drive holder connecting up with thre core flexiable copper conductor cable
21Supply and fix LED 20 Wattstube light ultra bright polycarbonate suited forwith G 13 Lamp holder all as specified and directed
22Supply and fixinground shape LED recessed/ surface light fitting 15Wcomplete withdrivers ,holders LED lampsincluding connecting up with 3 core 0.5sqmm copper wire between ceiling rose and fitting terminal Complete all as specified and as directed.
23Supply and FixingLED Bulb of 9 watts pin type all as specified and as directed. Make:Bajaj / CG / Havells
24Supply and Fixing MCB SP 5 to 32 Amps rating, 10 KAÇ "curve240V, 50 Hz AC Complete all as specified and as directed.
25Supply and FixingMCB SPN 32 Amps rating,10 KA "C"curve, 240V, 50 Hz AC Complete all as specified and as directed.
26Supply and Fixing MCB TP 25- 63 Amps rating, , 10 KA Ç" crve415V, 50 Hz AC complete all as specified.
27Supply and Fixing in repairs MCB TPN 63 Amps rating,, 10 KA Çcurve , 415V, 50 Hz AC Complete all as specified and as directed.
28Material and Labour forsub main wiring1100 volts grade PVC insulatedFRLS multistranded copper conductors, two runs of single core4 Sqmm along with one run 4 Sqmm PVC insulated single core FRLS multistranded copper conductor cable as earth continuity conductor along with one run of PVCconduit all as specified and as directed Note :-3 run ofmultistranded copperconductorand 1 run of PVC conduit shall be measured as one unit,
29Disconnecting the powersupply and taking down Ceiling fan ,Dismantling the defective Ceiling fans motor 1200mm sweep taking to work shop and by taking out burnt copper winding and rewinding with super enamelled copper wire of existing gauge and weight including replacement of all insulation material and other petty items required for making motor functional Complete all as specified and as directed.
30Dis connecting the power supply and taking down the exhaust fan , dismantling the defective Exhaust fans motor up300 mm sweeptaking to work shop and by taking out burnt copper winding and rewinding with super enamelled copper wire of existing gauge and weight including replacement of all insulation material, andother petty items required for making motor functional Complete all as specified and as directed. Note: item No -26&27 - Servicing ofExhaustfans and Spares will be measured and paid separately under relevant items of this schedule.
31Supply Only GM bush suitable for Ceiling fan 1200 Sweep Complete all as specified and as directed.
32Supply Only Ball bearings suitable for Ceiling fans / Exhaust fans / Wall mounting fans of 1200 Sweep Complete all as specified and as directed. Make: SKF / NBC / TATA or equivalent.
33Supply Only 2.5 MFD Capacitors for the fan in position Complete all as specified and as directed. Make - Usha / CG/ Havells
34Supply and fix ceiling fan complete with blades down rod electronic rerulator and accessories 230 V 1200 mm sweep Min air delivery 210 CFM five star brushless (BLDC)
35Supply and fix Exhaust fansteel body AC single phase 230 V 300 mm sweep with blades and frame with louvers
36Taking out unserviceable geyser elementSupplyandfixingheating elementsuitable to existing model and make 1.5 / 2 KW Dual clip type/tri angle type / round type with rubber gasketsuitable for geysers up to 25 Ltr capacity . Make: Theeta /Elteck or equivalent
37Taking out unserviceable thermostat Supplyandfixingthermostat clip type (Range 30 C° to 80 C and acting at 70C°) forgeysers up to 50 Lts all as specified . Make: Elcon or equivalent
38Takingout un serviceable PVC connectionSupplyand fixing15mmborePVC connections with brass nuts650 mm in length suitable to connect GI pipe 15 mm dia to hot /Cold water outlet of geyser. Complete all as specified and directed by Engr-in- chargeMake: Kohinoor or eqivalent
39Taking out unservice pressure release valveSupplyand fixing pressure release valves suitable for geyser up to 50 ltrs capacity type asper existing PR valve complete all as specified and directed by Engr-in- charge
40Taking out the unservieable 3 core wire supply and fix FRLS PVC Round insulated copper flexible cable 2.5 sqmm , 3 core PVC sheathed,1100 Volts grade complete allas specified and directed by Engr-in-charge
41Excavation in trenches in Soft / Loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables etc, getting out and forming bottom surface to required gradient Complete all as specified and as directed.
42Returning filling including Spreading levelling watering and well ramming to excavated soil in layers not exc 25 cm thick Complete all as specified and as directed
43Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point in soils Complete all as specified and as directed.
44Material and labour forriddledSandCushioning to cablesa layer of 8 cm thick beforelaying the cable and second layer of 15 cmthick after layingthe cable Complete all as specified and as directed. Note :- Sand shall be measured after punned down.
45S & Fsub classburnt Bricks for cable protection Complete all as specified and as directed
46Material and Labour for G.I. tubinglightgrade of size 50mm bore for protection of cables to be laid under roads, crossings / culverts Complete all as specified and as directed.
47Taking out old unserviceable UG cable, Supply and laying 25 Sqmm, 4 Core LT UG cable grade PVC XLPE insulated, PVC sheathed armoured, heavy duty, in trenches / walls / poles / passing through pipes with multistranded aluminium conductor including lugs / thimbles / ferrules connection, testing and commissioning Complete all as specified and as directed.
48Taking out old unserviceable UG cable, Supply and laying 16 Sqmm, 4 Core LT UG cable grade PVC XLPE insulated, PVC sheathed armoured, heavy duty, in trenches / walls / poles / passing through pipes with multistranded aluminium conductor including lugs / thimbles / ferrules connection, testing and commissioning Complete all as specified and as directed.
49Taking out old unserviceable UG cable, Supply and laying 10 Sqmm, 2 Core LT UG cable grade PVC XLPE insulated, PVC sheathed armoured, heavy duty, in trenches / walls / poles / passing through pipes with multistranded aluminium conductor including lugs / thimbles / ferrules connection, testing and commissioning Complete all as specified and as directed.
50Supply and FixingMCCB DB TPN 4 way,Double door, 415V, AC, 50 Hz, with 200 Amp rated bus bar
51Supply and fix 415 KA"B" Curveminiature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commission TPN/FP 40 to 100 Amps all as directed and directed
52Supply and Fixing MCCB Triple pole 415 volts 50 HZ AC suitable for current carrying capacity 25 to 100 Amps rating, fixed typewith rupturing capacity 16 KA all as specified and directed.
53Supply and Fixing in repairs MCCB 3 Pole, 415 volts 50 HZ AC suitable for current carrying capacity 160 Amps rating, fixed and thermal magnetic release with rupturing capacity 25 KA all as specified and directed.
54Supply and Fixing in repairs MCCB 4 Pole, 415 volts 50 HZ AC suitable for current carrying capacity 200 Amps rating, fixed and thermal magnetic release with rupturing capacity 35 KA all as specified and directed.
55Supply and Fixing in repairs MCCB4Pole, 415 volts 50 HZ AC suitable for current carrying capacity400 Amps rating, fixed and thermal magnetic release with rupturing capacity 36 KA all as specified and directed.
56Supply and fixingmoulded (FRP) junction boxwith IP 65 protection of size 300x200x80mm with 32 Amp 4 way heavy duty terminal block with 6Amp MCBSP and two number of cable entry gland of standard size with suitable stainless steel bracket to fix with pole complete all as directed
57Supply and Fixing in repairs Voltmeter digital type 0-500 Volts Complete all as specified and as directed.
58Supply and Fixing in repairs Ammeter digital type 0-200 Amps Complete all as specified and as directed.
59Taking out the unserviceable HPSV /CFL street light fitting any watts , Supply and fixing 35 WLEDstreetlight fitting with pressure die-cast housing with toughened glass and individual LEDs with secondary optics and IP 66 protection.
60Taking out the unserviceableflood light fittingsSupply and fixing 70 WLED flood light fitting230V out door type with thermal management in multiple optics and equipped with IP-66 protection with impact and corrosion resistants complete with driver and lamp
61Taking out the unserviceable post top latern fitting ,Supply and Fixingpost top lantern LED type 20 W 230 VoltsAC out door typewith decorativepost top for 360 degree indirect light IP65protection with impact and corrosionresistantCompletewith driver and lamp
62Repair/ servicing of out door typeAPFC panelat Akash Vihar :- (i) APFC panel (out door Type) 100 (8x12.5) KVAR - 02 No , (ii) APFC panel ( Out door Type) 125 (20x5,2X12.5) KVAR - 01 No capacitors, internal wiring,inresh current limiting coil ., auxillary contactor, indicating lamps, auto-manual selector switch, MCCB, axial flow fan and replace the unserviceable parts complete all as specified and as directed. The following checking will be carried outto ensure smooth and effective operation all the timeall as specified and directed. (a) Checking of the control panel, power supply, fuses, circuits etc and tighten to any loose contact.(b) Checking of the healthiness of capacitors, contactors and APFC relays. (c) Cleaningof the panel by using blower without any disturbance/ damages. Note:- spare parts materialwill be measured and paid separately under relevant items of this schedule.
63Supply Only in repairs10/12. 5 KVAR Capacitor heavy duty existing make and type440 volts with inrush current Limiting Coil Complete all as specified and as directed.
64Supply Only in repairs 20KVAR Capacitor heavy duty existing make and type440 volts with inrush current Limiting Coil Complete all as specified and as directed.
65Supply Only Automatic power factor relay ( APFCR )8 stage Complete all as specified and as directed. Make - Neptune
66Supply only duty contactor suitable for 20Kvar capacitor
67Supply only duty contactor suitable for12.5 Kvar capacitor
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail