Tender For Amc, Repairs And Other Emergent Works (Electrical) At Cuk, ganderbal-Jammu And Kashmir

Central University Of Kashmir-CUK has published Tender For Amc, Repairs And Other Emergent Works (Electrical) At Cuk. Submission Date for this Tender is 21-11-2022. Coats and Jackets Tenders in ganderbal Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

34532406
Corrigendum : Tender For Amc, Repairs And Other Emergent Works (Electrical) At Cuk
Open Tender
Indian
Jammu And Kashmir
ganderbal
21-11-2022

Tender Details

Annual Maintenance, Repairs And Other Emergent Works ( Electrical ) Across Different Campuses Of Central University Of Kashmir At Ganderbal. - Wiring For Light Point / Fan Point / Exhaust Fanpoint / / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required 2 Rewiring For Light Point / Fan Point / Exhuast Fan Point / Call Bell Point With 1.5 Sqmm Frls Pvc Insulated Copper Conductor Single Core Cable And 1.5 Sqmm Frls Pvc Insulated Copper Conductor Single Core Cable As Earth Wire In Existiing Surface / Recessed Steel / Pvc Conduit Including Dismantling As Required. 3 Supply And Drawing Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. ( 3X4sqmm ) 4 Supply And Fixing 3 Pin, 5 A Ceiling Rose On The Existing Junction Box / Wooden Block Including Connections Etc. As Required. 5 Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections Butmodular Plate Etc. As Required. 6 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required:1Or 2 Module ( 75 Mmx75 Mm ) 7 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required:3 Module ( 100Mmx75 Mm ) 8 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required:4 Module ( 125Mmx75 Mm ) 9 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required:6Module ( 200Mmx75 Mm ) 10 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required:8 Module ( 125Mmx125 Mm ) 11 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required :5 / 6 A Switch. 12 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.2 Way 5 / 6 A Switch 13 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15 / 16 A Switch 14 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.3 Pin 5 / 6 A Socket Outlet 15 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15 / 16 A Socket Outlet 16 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required.2 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 17 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. 2 X 4Sq. Mm + 1 X 4 Sq. Mm Earth Wire 18 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required.2 X 6Sq. Mm + 1 X 6Sq. Mm Earth Wire 19 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. 2 X 10 Sq. Mm + 1 X 6 Sq. Mm Earth Wire 20 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required.2 X 16Sq. Mm + 1 X 6 Sq. Mm Earth Wire 21 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required.4 X 2.5Sq. Mm + 2 X 2.5Sq. Mm Earth Wire 22 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required.4 X 4Sq. Mm + 2 X 4Sq. Mm Earth Wire 23 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. ( 4 X 6Sq. Mm + 2 X 6Sq. Mm Earth Wire ) 24 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required ( 4 X 10Sq. Mm + 2 X 6Sq. Mm Earth Wire ) 25 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required. ( 4 X 16Sq. Mm + 2 X 6Sq. Mm Earth Wire ) 26 Supply And Fixing Pvc Batten / Angle Holder Including Connections Etc. As Required. 27 Dismentaling Of Ceiling Fan And Painting The Same With One Or More Coats Of Spray Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade, Including Cleaning The Surface With Detergent And Replacing The Damaged Rubber Reet, Nuts, And Bolts With Washers And Safety Pins, Reinstalling The Same As Required. 28 Providing And Fixing M.V Danger Notice Plate Of 200Mmx150mm, Made Of Mild Steel, At Least 2Mm Thick And Vitreous Enameled White On Both Sides, And With Incription In Single Red Colouron Front Side As Required. 29 Providing And Fixing H.T Danger Notice Plate Of 250Mmx200mm, Made Of Mild Steel, At Least 2Mm Thick And Vitreous Enameled White On Both Sides, And With Incription In Single Red Colouron Front Side As Required. 30 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5 / 6 A Modular Socket Outlet And 5 / 6A Modular Switch, Connections Etc. As Required. 31 Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5 / 6 A & 15 / 16 A Modular Socket Outlet And 15 / 16 A Modular Switch, Connections Etc. As Required. 32 Supply And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 2No.S 3 Pin 5 / 6 Amp Modular Socket Outlet And 2 No. 5 / 6 Amp Modular Switch Connections Etc As Required. 33 Supplying And Fixing 20 A, 240 V, Spn Industrial Type Socket Outlet, With 2 Pole And Earth, Metal Enclosed Plug Top Alongwith 20 A, “C” Curve, Sp, Mcb, In Sheet Steel Enclosure, On Surface Or In Recess, With Chained Metal Cover For The Socket Out Let And Complete With Connections, Testing And Commissioning Etc. As Required. 34 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.With 20 Mm. 35 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.With 25 Mm. 36 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.With 32 Mm. 37 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.With 40Mm. 38 Supply And Fixing Of Single Pole And Neutral Sheet Steel Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Busbar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted, Including Earthing Etc As Required ( But Without Mccb / Rccb / Isolator ) 6 Way Double Door 39 Supply And Fixing Of Single Pole And Neutral Sheet Steel Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Busbar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted, Including Earthing Etc As Required ( But Without Mccb / Rccb / Isolator ) 8 Way Double Door 40 Supply And Fixing Of Single Pole And Neutral Sheet Steel Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Busbar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted, Including Earthing Etc As Required ( But Without Mccb / Rccb / Isolator ) 12 Way Double Door 41 Supply And Fixing Of Single Pole And Neutral Sheet Steel Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Busbar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted, Including Earthing Etc As Required ( But Without Mccb / Rccb / Isolator ) 16 Way Double Door 42 Supplying And Fixing 5A To 32A Rating, 240 / 415V 10 Ka, “C” Curve, Ssuitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. ( Single Pole ) 43 Supplying And Fixing 5A To 32A Rating, 240 / 415V 10 Ka, “C” Curve, Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. ( Single Pole And Neutral ) 44 Supplying And Fixing 5A To 32A Rating, 240 / 415V 10 Ka, “C” Curve, Ssuitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. ( Double Pole ) 45 Supplying And Fixing 5A To 32A Rating, 240 / 415V 10 Ka, “C” Curve, Ssuitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. ( Triple Pole ) 46 Supplying And Fixing 5A To 32A Rating Triple Pole And Neutral, 415 V, 10 Ka, “C” Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required ( Triple Pole And Neutral ) 47 Supply, Installing, Testing And Commissioning Of Tpn Tap Off Box Made Of 1.6Mm Of Thick Sheet Steel Enclosure Duly Painted With Powder Coating On Exixting Rising Mains Complete With Tpn Disconnecter Fsu And Hrc Fuses, Connections, Earthing, Etc As Required. ( 16Amp Tpn ) 48 Supply, Installing, Testing And Commissioning Of Tpn Tap Off Box Made Of 1.6Mm Of Thick Sheet Steel Enclosure Duely Painted With Powder Coating On Exixting Rising Mains Complete With Tpn Disconnecter Fsu And Hrc Fuses, Connections, Earthing, Etc As Required. ( 32Amp Tpn ) 49 Supply, Installing, Testing And Commissioning Of Tpn Tap Off Box Made Of 1.6Mm Of Thick Sheet Steel Enclosure Duely Painted With Powder Coating On Exixting Rising Mains Complete With Tpn Disconnecter Fsu And Hrc Fuses, Connections, Earthing, Etc As Required. ( 63Amp Tpn ) 50 Supply, Installing, Testing And Commissioning Of Tpn Tap Off Box Made Of 1.6Mm Of Thick Sheet Steel Enclosure Duely Painted With Powder Coating On Exixting Rising Mains Complete With Tpn Disconnecter Fsu And Hrc Fuses, Connections, Earthing, Etc As Required. ( 100Amp Tpn ) 51 Supply, Installing, Testing And Commissioning Of Tpn Tap Off Box Made Of 1.6Mm Of Thick Sheet Steel Enclosure Duely Painted With Powder Coating On Exixting Rising Mains Complete With Tpn Disconnecter Fsu And Hrc Fuses, Connections, Earthing, Etc As Required. ( 200Amp Tpn ) 52 Supply, Installing, Testing And Commessioning Of Tpn Tap Off Box Made Of 1.6Mm Of Thick Sheet Steel Enclosure Duely Painted With Powder Coating On Exixting Rising Mains Complete With Tpn Disconnecter Fsu And Hrc Fuses, Connections, Earthing, Etc As Required. ( 315Amp Tpn ) 53 Supply, Installing, Testing And Commessioning Of Tpn Tap Off Box Made Of 1.6Mm Of Thick Sheet Steel Enclosure Duely Painted With Powder Coating On Exixting Rising Mains Complete With Tpn Disconnecter Fsu And Hrc Fuses, Connections, Earthing, Etc As Required. ( 400Amp Tpn ) 54 Supplying, Installing, Testing And Commissioning Of Following Capacity End Feed Unit Made Of 1.6Mm Thick Sheet Steel Enclosure Duly Painted With Powder Coating To Existing Rising Mains Complete With Tpn Disconnector Fsu And Hrc Fuses, Mounting Stands, Cable End Box, Brass Compression Gland, Connections, Earthing Etc. As Required. ( 200Amp Tpn ) 55 Supplying, Installing, Testing And Commissioning Of Following Capacity End Feed Unit Made Of 1.6Mm Thick Sheet Steel Enclosure Duly Painted With Powder Coating To Existing Rising Mains Complete With Tpn Disconnector Fsu And Hrc Fuses, Mounting Stands, Cable End Box, Brass Compression Gland, Connections, Earthing Etc. As Required. ( 300Amp Tpn ) 56 Supplying, Installing, Testing And Commissioning Of Following Capacity End Feed Unit Made Of 1.6Mm Thick Sheet Steel Enclosure Duly Painted With Powder Coating To Existing Rising Mains Complete With Tpn Disconnector Fsu And Hrc Fuses, Mounting Stands, Cable End Box, Brass Compression Gland, Connections, Earthing Etc. As Required. ( 400Amp Tpn ) 57 Supplying, Installing, Testing And Commissioning Of Following Capacity End Feed Unit Made Of 1.6Mm Thick Sheet Steel Enclosure Duly Painted With Powder Coating To Existing Rising Mains Complete With Tpn Disconnector Fsu And Hrc Fuses, Mounting Stands, Cable End Box, Brass Compression Gland, Connections, Earthing Etc. As Required. ( 600Amp Tpn ) 58 Supplying, Installing, Testing And Commissioning Of Following Capacity End Feed Unit Made Of 1.6Mm Thick Sheet Steel Enclosure Duly Painted With Powder Coating To Existing Rising Mains Complete With Tpn Disconnector Fsu And Hrc Fuses, Mounting Stands, Cable End Box, Brass Compression Gland, Connections, Earthing Etc. As Required. ( 800Amp Tpn ) 59 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Direct In Ground Including Excavation And Refilling The Trench Etc As Required, But Excluding Sand Cushioning And Protective Covering. ( Upto 35 Sq.Mm ) 60 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Direct In Ground Including Excavation And Refilling The Trench Etc As Required, But Excluding Sand Cushioning And Protective Covering. ( Above 35 Sq.Mm And Upto 95Sq.Mm ) 61 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Direct In Ground Including Excavation And Refilling The Trench Etc As Required, But Excluding Sand Cushioning And Protective Covering. ( Above 95 Sq.Mm And Upto 185Sq.Mm ) 62 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Direct In Ground Including Excavation And Refilling The Trench Etc As Required, But Excluding Sand Cushioning And Protective Covering. ( Above 185 Sq.Mm And Upto 400Sq.Mm ) 63 Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1Kv Grade Of Following Size On Wall Surface As Required. ( Upto 35Sq.Mm, Clamped With 1Mm Thick Saddle ) 64 Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1Kv Grade Of Following Size On Wall Surface As Required. ( Above 35Sq.Mm And Upto 95Sq.Mm, Clamped With 25X3mm Ms Flat Clamp ) 65 Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1Kv Grade Of Following Size On Wall Surface As Required. ( Above 95Sq.Mm And Upto 185Sq.Mm, Clamped With 25 / 40X3mm Ms Flat Clamp ) 66 Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1Kv Grade Of Following Size On Wall Surface As Required. ( Above 185Sq.Mm And Upto 400Sq.Mm, Clamped With 40X3mm Ms Flat Clamp ) 67 Supply, Installation, Testing And Commissioning Of 1200Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current ( Bldc ) . Motor, Class Of Insulation:B, 3 Nos. Blades, 30 Cm Long Down Rod, 24Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factor Not Less Than 0.9, Service Value ( Cm / M / W ) Minimum 6.00, Air Delivery Minimum 210 Cum / Min , 350 Rpm ( Tolerance As Per Is : 374-2019 ) , Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speed Control And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C ( Max. ) , Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Ac , Supply, Earthing Etc. Complete As Required. 68 Supply, Installation, Testing And Commissioning Of Led Rods 4Ft In Length. 69 Supplying, Erection And Testing Of Approved Make Electric Wall Fan Ofcomplete With Standard Down Rod, Canopy, Hanging Shackle, Aluminium Blades, A.C. 230-250 Volts Including Connectionswith All Necessary Material Complete Of Approved As Required -300 / 400 Mm Sweep, 80-90W. 70 Supplying Ofapproved Make Exhaust Fan Of 250 / 300Mmsweep With Mounting Frame, Blades Ac 230-250 Complete Connection And Including, Frame Bolt / Anchor Hole Fastners Etc. Complete Finishedas Required. 71 Installation Of Exhaust Fan In The Existing Opening, Including Making Good The Damage, Connection, Testing, Commissioning Etc. As Required.:Upto 250 / 300 Mm Sweep 72 Supply , Installation , Testing And Commissioning Of Flood Lights Of 45-70 Watt Capacity ( Havells Anchor Syska Bajaj Anchor ) 73 Providinginstallation Testing And Commissioning Of Chemical Earthing With 03 Meter Galavnised Electrode Etc As Required. 74 Providing And Fixing Of Testing Terminal Brass Type 75 Providingand Fixing 25Mmx 5Mm Gi Stripon Surface Or In Cecess For Connections Etc. As Required 76 Supply, Installation And Testing Of Led Surface / Concealed Light With20-30W Complete Assembly As Required As Per Required 77 Supply Of Aluminium Conductor , Armored , Xlpe Insulated Power Cable Of 1.1Kv Grade. ( 3.5C X 300Sqmm ) 78 Supply Of Aluminium Conductor , Armored , Xlpe Insulated Power Cable Of 1.1Kv Grade. ( 3.5C X 185Sqmm ) 79 Supply Of Aluminium Conductor , Armored , Xlpe Insulated Power Cable Of 1.1Kv Grade. ( 3.5C X 120Sqmm ) 80 Supply Of Aluminium Conductor , Armored , Xlpe Insulated Power Cable Of 1.1Kv Grade. ( 3.5C X 70Sqmm ) 81 Supply Of Aluminium Conductor , Armored , Xlpe Insulated Power Cable Of 1.1Kv Grade. ( 3.5C X 35Sqmm ) 82 Supply Of Aluminium Conductor , Armored , Xlpe Insulated Power Cable Of 1.1Kv Grade. ( 4C X 16Sqmm ) 83 Supply Of Aluminium Conductor , Armored , Xlpe Insulated Power Cable Of 1.1Kv Grade. ( 4C X 10Sqmm ) 84 Supply Of Aluminium Conductor , Armored , Xlpe Insulated Power Cable Of 1.1Kv Grade. ( 4C X 6Sqmm ) 85 Supply Of Aluminium Conductor , Armored , Xlpe Insulated Power Cable Of 1.1Kv Grade. ( 4C X 4Sqmm ) 86 Supply & Installation Of Pvc Copper Wire Single Core 16Sqmm 87 Supply & Installation Of Pvc Copper Wire Single Core 10Sqmm 88 Suopply Installation Testing Commissioning Of 100 Amp, 3 Phase 4 Pole Change Over Front Load Type 89 Suopply Installation Testing Commissioning Of 200Amp, 3 Phase 4 Pole Change Over Front Load Type 90 Suopply Installation Testing Commissioning Of 400 Amp, 3 Phase4 Pole Change Over Front Load Type 91 Suopply Installation Testing Commissioning Of 600 Amp, 3 Phase4 Pole Change Over Front Load Type 92 Supply Installation / Fixing Of Led Lamp 9-15 Watts 93 Supply Installation / Fixing Of Led Rod 2 Feet 9-15 Watts 94 Supply Installation / Fixing Of Led Rod 1 Feet 9-15 Watts 95 Supply Installation / Fixing Of3 Phase Copper Busbar63 Amp 96 Supply Installation / Fixing Of3 Phase Copper Busbar100 Amp 97 Supply Installation / Fixing Of3 Phase Copper Busbar200 Amp 98 Supply Installation / Fixing Ofcordless Room Bell 99 Supply Installation / Fixing Of Hanging Jar With Led Lamp Nuts, Bolts Etc As Required At Site Complete Job 100 Supply Fixing Of Aluminium Lugs Of 50Sqmm Size 101 Supply Fixing Of Aluminium Lugs Of 120Sqmm Size 102 Supply Fixing Of Copper Lugs Of 10Sqmm Size 103 Supply Fixing Of Copper Lugs Of 16Sqmm Size 104 Supply Fixing Of Copper Lugs Of 25Sqmm Size 105 Supply Fixing Of Copper Lugs Of 35Sqmm Size

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-Nov-2022 Extension in Last Date of Bid Submission Date 21-11-2022

Key Value

Document Fees
INR 1000 /-
EMD
INR 30000.0 /-
Tender Value
INR 15 Lakhs /-

BOQ Items

Name of Work: Annual maintenance, repairs and other emergent works (Electrical) across different campuses of Central University of Kashmir at Ganderbal.
Sl. No. Item Description
1Wiring for Light point/fan point/exhaust fanpoint//call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required
2Rewiring for light point/Fan point/exhuast fan point/call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable and 1.5 sqmm FRLS PVC insulated copper conductor single core cable as earth wire in existiing surface/recessed steel/PVC conduit including dismantling as required.
3supply and drawing of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required.(3x4sqmm)
4supply and fixing 3 pin, 5 A ceiling rose on the existing junction box/wooden block including connections etc. as required.
5Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections butmodular plate etc. as required.
6Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required:1OR 2 Module (75 mmX75 mm)
7Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required:3 Module (100mmX75 mm)
8Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required:4 Module (125mmX75 mm)
9Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required:6Module (200mmX75 mm)
10Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required:8 Module (125mmX125 mm)
11Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required :5/6 A switch.
12Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.2 way 5/6 A switch
13Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 A switch
14Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 A socket outlet
15Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 A socket outlet
16Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
17Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4sq. mm + 1 X 4 sq. mm earth wire
18Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 6sq. mm + 1 X 6sq. mm earth wire
19Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 10 sq. mm + 1 X 6 sq. mm earth wire
20Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 16sq. mm + 1 X 6 sq. mm earth wire
21Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4 X 2.5sq. mm + 2 X 2.5sq. mm earth wire
22Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4 X 4sq. mm + 2 X 4sq. mm earth wire
23Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (4 X 6sq. mm + 2 X 6sq. mm earth wire)
24Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required (4 X 10sq. mm + 2 X 6sq. mm earth wire)
25Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (4 X 16sq. mm + 2 X 6sq. mm earth wire)
26supply and fixing PVC batten/angle holder including connections etc. as required.
27Dismentaling of ceiling Fan and painting the same with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade, including cleaning the surface with detergent and replacing the damaged rubber reet, nuts, and bolts with washers and safety pins, reinstalling the same as required.
28Providing and fixing M.V danger notice plate of 200mmx150mm, made of mild steel, at least 2mm thick and vitreous enameled white on both sides, and with incription in single red colouron front side as required.
29Providing and fixing H.T danger notice plate of 250mmx200mm, made of mild steel, at least 2mm thick and vitreous enameled white on both sides, and with incription in single red colouron front side as required.
30Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6A modular switch, connections etc. as required.
31Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
32supply and fixing suitable size GI Box with modular plate and cover in front on surface or in recess, including providing and fixing 2no.s 3 pin 5/6 Amp modular socket outlet and 2 no. 5/6 Amp modular switch connections etc as required.
33Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
34Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.with 20 mm.
35Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.with 25 mm.
36Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.with 32 mm.
37Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.with 40mm.
38Supply and fixing of single pole and neutral sheet steel MCB Distribution Board, 240 V, on surface/recess, complete with tinned copper busbar,neutral bus bar, earth bar, din bar, interconnections, powder painted,including earthing etc as required (but without MCCB/RCCB/Isolator)6 way double door
39Supply and fixing of single pole and neutral sheet steel MCB Distribution Board, 240 V, on surface/recess, complete with tinned copper busbar,neutral bus bar, earth bar, din bar, interconnections, powder painted,including earthing etc as required (but without MCCB/RCCB/Isolator) 8 way double door
40Supply and fixing of single pole and neutral sheet steel MCB Distribution Board, 240 V, on surface/recess, complete with tinned copper busbar,neutral bus bar, earth bar, din bar, interconnections, powder painted,including earthing etc as required (but without MCCB/RCCB/Isolator) 12 way double door
41Supply and fixing of single pole and neutral sheet steel MCB Distribution Board, 240 V, on surface/recess, complete with tinned copper busbar,neutral bus bar, earth bar, din bar, interconnections, powder painted,including earthing etc as required (but without MCCB/RCCB/Isolator) 16 way double door
42Supplying and fixing 5A to 32A rating, 240/415V 10 kA, “C” curve, Ssuitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Single Pole)
43Supplying and fixing 5A to 32A rating, 240/415V 10 kA, “C” curve, suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(Single Pole and Neutral)
44Supplying and fixing 5A to 32A rating, 240/415V 10 kA, “C” curve, Ssuitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Double Pole)
45Supplying and fixing 5A to 32A rating, 240/415V 10 kA, “C” curve, Ssuitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(Triple Pole)
46Supplying and fixing 5A to 32A rating Triple pole and neutral, 415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required (Triple pole and neutral)
47Supply,installing, testing and commissioning of TPN Tap off box made of 1.6mm of thick sheet steel enclosure duly painted with powder coating on exixting rising mains complete with TPN disconnecter FSU and HRC fuses, connections, earthing, etc as required. (16Amp TPN)
48Supply,Installing, Testing and Commissioning of TPN Tap off box made of 1.6mm of thick sheet steel enclosure duely painted with powder coating on exixting rising mains complete with TPN disconnecter FSU and HRC fuses, connections, earthing, etc as required. (32Amp TPN)
49Supply,Installing, Testing and Commissioning of TPN Tap off box made of 1.6mm of thick sheet steel enclosure duely painted with powder coating on exixting rising mains complete with TPN disconnecter FSU and HRC fuses, connections, earthing, etc as required. (63Amp TPN)
50Supply,Installing, Testing and Commissioning of TPN Tap off box made of 1.6mm of thick sheet steel enclosure duely painted with powder coating on exixting rising mains complete with TPN disconnecter FSU and HRC fuses, connections, earthing, etc as required. (100Amp TPN)
51Supply,Installing, Testing and Commissioning of TPN Tap off box made of 1.6mm of thick sheet steel enclosure duely painted with powder coating on exixting rising mains complete with TPN disconnecter FSU and HRC fuses, connections, earthing, etc as required. (200Amp TPN)
52Supply,installing, testing and commessioning of TPN Tap off box made of 1.6mm of thick sheet steel enclosure duely painted with powder coating on exixting rising mains complete with TPN disconnecter FSU and HRC fuses, connections, earthing, etc as required. (315Amp TPN)
53Supply,installing, testing and commessioning of TPN Tap off box made of 1.6mm of thick sheet steel enclosure duely painted with powder coating on exixting rising mains complete with TPN disconnecter FSU and HRC fuses, connections, earthing, etc as required. (400Amp TPN)
54Supplying, Installing, Testing and Commissioning of following capacity End Feed Unit made of 1.6mm thick sheet steel enclosure duly painted with powder coating to existing rising mains complete with TPN disconnector FSU and HRC fuses, mounting stands, cable end box, brass compression gland, connections, earthing etc. as required. (200Amp TPN)
55Supplying, Installing, Testing and Commissioning of following capacity End Feed Unit made of 1.6mm thick sheet steel enclosure duly painted with powder coating to existing rising mains complete with TPN disconnector FSU and HRC fuses, mounting stands, cable end box, brass compression gland, connections, earthing etc. as required. (300Amp TPN)
56Supplying, Installing, Testing and Commissioning of following capacity End Feed Unit made of 1.6mm thick sheet steel enclosure duly painted with powder coating to existing rising mains complete with TPN disconnector FSU and HRC fuses, mounting stands, cable end box, brass compression gland, connections, earthing etc. as required. (400Amp TPN)
57Supplying, Installing, Testing and Commissioning of following capacity End Feed Unit made of 1.6mm thick sheet steel enclosure duly painted with powder coating to existing rising mains complete with TPN disconnector FSU and HRC fuses, mounting stands, cable end box, brass compression gland, connections, earthing etc. as required. (600Amp TPN)
58Supplying, Installing, Testing and Commissioning of following capacity End Feed Unit made of 1.6mm thick sheet steel enclosure duly painted with powder coating to existing rising mains complete with TPN disconnector FSU and HRC fuses, mounting stands, cable end box, brass compression gland, connections, earthing etc. as required. (800Amp TPN)
59Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. (upto 35 sq.mm)
60Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. (above 35 sq.mm and upto 95sq.mm)
61Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. (above 95 sq.mm and upto 185sq.mm)
62Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. (above 185 sq.mm and upto 400sq.mm)
63Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following size on wall surface as required. (Upto 35sq.mm, clamped with 1mm thick saddle)
64Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following size on wall surface as required. (above 35sq.mm and upto 95sq.mm, clamped with 25x3mm MS flat clamp)
65Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following size on wall surface as required. (above 95sq.mm and upto 185sq.mm, clamped with 25/40x3mm MS flat clamp)
66Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following size on wall surface as required. (above 185sq.mm and upto 400sq.mm, clamped with 40x3mm MS flat clamp)
67Supply, Installation, Testing and Commissioning of 1200mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC). Motor, class of insulation:B, 3 nos. blades, 30 cm long down rod, 24nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC , Supply, earthing etc. complete as required.
68Supply, Installation, Testing and Commissioning of LED rods 4ft in length.
69Supplying, erection and testing of approved make electric Wall fan ofcomplete with standard down rod, canopy, hanging shackle, Aluminium blades,A.C. 230-250 volts including connectionswith all necessary material complete of approved as required -300/400 mm sweep,80-90W.
70Supplying ofapproved make Exhaust Fan of 250/300mmsweep with mounting frame, blades AC 230-250 complete connection and including, frame bolt/ Anchor hole fastners etc. complete finishedas required.
71Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.:Upto 250/300 mm sweep
72Supply , installation , testing and commissioning of flood lights of 45-70 watt capacity (Havells Anchor syska bajaj Anchor)
73ProvidingInstallation Testing and Commissioning of Chemical earthing with 03 meter Galavnised Electrode etc as required.
74Providing and Fixing of Testing Terminal Brass Type
75Providingand Fixing 25mmX 5mm GI Stripon surface or in cecess for connections etc. as required
76Supply,installation and Testing of LED Surface /concealed Light with20-30W complete assembly as required as per required
77Supply of Aluminium conductor , armored ,XLPE Insulated Power Cable of 1.1KV grade. ( 3.5C x 300Sqmm)
78Supply of Aluminium conductor , armored ,XLPE Insulated Power Cable of 1.1KV grade. ( 3.5C x 185Sqmm)
79Supply of Aluminium conductor , armored ,XLPE Insulated Power Cable of 1.1KV grade. ( 3.5C x 120Sqmm)
80Supply of Aluminium conductor , armored ,XLPE Insulated Power Cable of 1.1KV grade. ( 3.5C x 70Sqmm)
81Supply of Aluminium conductor , armored ,XLPE Insulated Power Cable of 1.1KV grade. ( 3.5C x 35Sqmm)
82Supply of Aluminium conductor , armored ,XLPE Insulated Power Cable of 1.1KV grade. ( 4C x 16Sqmm)
83Supply of Aluminium conductor , armored ,XLPE Insulated Power Cable of 1.1KV grade. ( 4C x 10Sqmm)
84Supply of Aluminium conductor , armored ,XLPE Insulated Power Cable of 1.1KV grade. ( 4C x 6Sqmm)
85Supply of Aluminium conductor , armored ,XLPE Insulated Power Cable of 1.1KV grade. ( 4C x 4Sqmm)
86Supply & Installation of PVC Copper Wire single core 16sqmm
87Supply & Installation of PVC Copper Wire single core 10sqmm
88Suopply installation testing commissioning of 100 AMP, 3 phase 4 pole change over front load type
89Suopply installation testing commissioning of 200AMP, 3 phase 4 pole change over front load type
90Suopply installation testing commissioning of 400 AMP, 3 phase4 pole change over front load type
91Suopply installation testing commissioning of 600 AMP, 3 phase4 pole change over front load type
92Supply installation/fixing of LED Lamp 9-15 watts
93Supply installation/fixing of LED rod 2 feet 9-15 watts
94Supply installation/fixing of LED rod 1 feet 9-15 watts
95Supply installation/fixing of3 phase copper busbar63 Amp
96Supply installation/fixing of3 phase copper busbar100 Amp
97Supply installation/fixing of3 phase copper busbar200 Amp
98Supply installation/fixing ofcordless room bell
99Supply installation/fixing of hanging jar with LED Lamp nuts, bolts etc as required at site complete job
100Supply fixing of Aluminium Lugs of 50sqmm size
101Supply fixing of Aluminium Lugs of 120sqmm size
102Supply fixing of Copper Lugs of 10sqmm size
103Supply fixing of Copper Lugs of 16sqmm size
104Supply fixing of Copper Lugs of 25sqmm size
105Supply fixing of Copper Lugs of 35sqmm size