Tender For Repair Maintenance And Improvement E And M Installations Lt Oh Distribution System Lt Ug Cables Apfc Panels Switchgears And Other Misc E And M Works At Palampur Mil Stn, palampur-Himachal Pradesh

Military Engineer Services-MES has published Tender For Repair Maintenance And Improvement E And M Installations Lt Oh Distribution System Lt Ug Cables Apfc Panels Switchgears And Other Misc E And M Works At Palampur Mil Stn. Submission Date for this Tender is 15-11-2022. LT Cable Tenders in palampur Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

34525100
Tender For Repair Maintenance And Improvement E And M Installations Lt Oh Distribution System Lt Ug Cables Apfc Panels Switchgears And Other Misc E And M Works At Palampur Mil Stn
Open Tender
Indian
Himachal Pradesh
palampur
15-11-2022

Tender Details

Repair Maintenance And Improvement E And M Installations Lt Oh Distribution System Lt Ug Cables Apfc Panels Switchgears And Other Misc E And M Works At Palampur Mil Stn

Key Value

Document Fees
INR 500 /-
EMD
INR 46000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR/MAINTENANCE AND IMPROVEMENT E/M INSTALLATIONS, LT OH DISTRIBUTION SYSTEM, LT UG CABLES, APFC PANELS, SWITCHGEARS AND OTHER MISC E/M WORKS AT PALAMPUR MIL STN
Sl. No. Item Description
1Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc or for laying of cables, errection of poles, struts / stays etc including taking out cable cover or stone slab, not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and directed.
2Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m but n exc 3.00 m in depth for foundation etc or for laying of cables, errection of poles, struts / stays etc including taking out cable cover or stone slab, not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and directed.
3Returning filling in including spreading leveling watering and well ramming inlayers not exceeding 25 cm in any type of soil complete all as specified and directed.
4Removing excavated any type of soil to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
5M&L sand cushioning to undergound cable with using fine river sand and gently punning for cushioning to cable complete all as specified and as directed. Note:-for the purpose of payment only punned thickness will be measured.
6S&F 40mm bore galvanised iron, light grade (ISI marked) laid in trenches / fixed on wall / poles etc for protection of cable,,including taking out old tubing complete all as specified and as directed.
7S&F 50mm bore galvanised iron, light grade (ISI marked) laid in trenches / fixed on wall / poles etc for protection of cable,,including taking out old tubing complete all as specified and as directed.
8S&F 80mm bore galvanised iron, light grade (ISI marked) laid in trenches / fixed on wall / poles etc for protection of cable,including taking out old tubing complete all as specified and as directed.
9M&L cement concrete (1:3:6) type C2 using 40mm graded crushed stone aggregates for foundation of poles / struts / stays etc including demolition of damaged foundation complete all as specified and directed.
10M&L PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate for pedestal including necessary formwork and fair finishing to exposed surface without using extra cement including dismantling of damaged padestal complete all as specified and directed.
11Supply and fix in replacement Digital voltmeter in96x96 Sqmm three phase class 1.0including making necessary connection in existing panel complete all as specified and directed.
12Supply and fix in replacement Digitalammeterin96x96 Sqmm three phase class 1.0including making necessary connection in existing panel complete all as specified and directed.
13Supply and fix in replacementselector switch for voltmeter/ammeter including making necessary connection in existing panel complete all as specified and directed.
14Supply and fix in replacementneon indicator lamp with holder assembly RYB including making necessary connection in existing panel complete all as specified and directed.
15Supply and fix in replacementCT coil of existing capacity including making necessary connection in existing panel complete all as specified and directed.
16Cutting and removing existing wild grass, vegetation, creepers, small plants / bushes etc clamping up towards the poles and stays etc including cleaning bottom surface area of pole &stay not less than 1m x 1m by surface dressing of earth outside and inside substations, perimeter fencing around pump house area, and in drains surrounding area from site complete all as specified and directed.
17Supply and fix in replacement synthetic insulation mat 2m x 1m x 10mmcomplete all as specified and directed.
18M&L 20X15cm size LT danger notice plate of 1.60mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in single red colour and fixed with M.S clamps,bolts and nutsincluding taking down existing rusted danger notice plate complete all as specified and directed.
19Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated,armoured electric cable with aluminium conductor ,cross-sectional area 120sq.mm 3 1/2core including taking down old unserviceable cable complete all as specified and directed.
20Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated,armoured electric cable with aluminium conductor ,cross-sectional area 95sq.mm 3 1/2core including taking down old unserviceable cable complete all as directed.
21Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated,armoured electric cable with aluminium conductor ,cross-sectional area 70sq.mm 3 1/2core including taking down old unserviceable cable complete all as directed.
22Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated,armoured electric cable with aluminium conductor ,cross-sectional area 50sq.mm 3 1/2core including taking out old unserviceable cable complete all as directed.
23M&L cable jointing kit, straight through heat shrinkable type suitable for 1100 volts grade XLPE armoured aluminium conductor cable of size 70 Sqmm to 150 Sqmm with jointing material and accessories including taking down if required complete all as directed.
24M&L cable jointing kit, straight through heat shrinkable type suitable for 1100 volts grade XLPE armoured aluminium conductor cable of size 185 Sqmm to 300 Sqmm with jointing material and accessories including taking down if required complete all as directed.
25M&L cable jointing kit, straight through heat shrinkable type suitable for 1100 volts grade XLPE armoured aluminium conductor cable of size 400 Sqmm with jointing material and accessories including taking down if required complete all as directed.
26M&L steel tubular swaged poles complete with cast iron base plate,finial taper plug,bolts,nuts and screws as specified type 410 SP-31 (9 metres long)including one coat of red oxide zinc chrome primer and two coats of aluminium paints,making 30cm wide strips (total 5 Nos) with yellow and black paints alternative on pole above PCC padestal and writing pole number etc. including taking down old unserviceable pole of any description complete all as specified and directed. Note:- Earth work and PCC work shall be measured and paid separately under respective items.
27M&L cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including dismantling existing unservicable cross arms, bracings etc. complete all as specified and directed.
28M&L painting to existing PCC/steel tubular LT poles, 8.5/9m long including cross arms, channels, angle iron support, bracings, clamps etc., with two coats of aluminium paint superior quality of approved make on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with white and black paint alternately on external surface above PCC benching including preparation of old painted surfaces gby scraping including writing MES LT feeder No and pole No (in capital letters) stencil cut decorative manner on pole using fluorescent paint complete all as specified and directed.
29M&L trimming of tree branches from HT/LT overhead line to branch clear 2 mtr on both side & re-stretching ACSR conductor and earth wire of any size and type on HT/LT poles including disconnecting and rebinding with insulators with suitable size of binding wire after restretching, connecting jumpers, adjusting line deviders etc., complete including removing and refixing of UG cable/service wires to the ACSR conductor, complete all as directed. Note:- (i)Single length of the conductor shall be measured for payment purpose only. (ii)The wastage shall be cleared from the pole surrounding.
30M&L aluminium conductor, steel reinforced (ACSR) conductor for LT lines on PCC/steel tubular poles, stretching without kinks and bends including binding wire including taking down old conductor of any type shape and size complete all as specified. Note:- Weight of ACSR or all aluminium conductors drawn for overhead lines is to be determined by measuring taut horizontal distance between centres of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra added for sag, jointing, jumpers etc. Make:- As approved by GE.
31Supply and fixing in replacement of PVC LT line separator 4/5 way, complete all as specified and directed.
32Supply and fixing in replacement of PVC LT line separator 2/3 way, complete all as specified and directed.
33M&L stay assembly using stay rod of 20mm dia complete with accessories as shown in Electrical Plate No. 1 of SSR 2009 Part-I with galvanized steel stranded wire of size specified, including taking down old stay assembly of any type complete all as specified and directed. Note: Loop insulator, earth work and PCC shall be measured and paid separately under respective items.
34Supply and fixing loop type insulator, porcelain, vitreous white, brown or green, large size with overall dimensions 90x140mm clearance of hole 25.5mm dia for 1100 volts including taking down old loop insulator of any type complete all as specified and directed.
35Supply and fixing of pin type, procelain, vitreous, white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 100 mm height, 65 mm dia for 1100 volts, including taking down old pin insulator of any type complete all as specified and directed.
36Supply and fixing of shackle type insulator porcelain vitreous white, brown or green 75mm height and 90mm dia for conductor of working pressure 1100 volts including galvanized mild steel strips of 31x3mm size, 12mm dia insulator bolts, washers and nuts, including taking down old shackle insulator of any type complete all as specified and directed.
37M&L cradles, hexagonal/rectangular, fabricated with galvanized steel wire 3.15 or 4mm dia including taking down old cradles of any type complete all as specified and directed.
38M&L old size brick class "B" as in cable protection laid dry,flat,transversally along the length of cable on sand cushioning with width equal to length of the brickcomplete all as specified and as directed.
39Supply and fix in replacement MCCB,AC,415volts, 250 Amp, 35/36KA,4 pole, with microprocessor release including making necessary connection in existing panel complete all as specified and directed.
40Supply and fix in replacement MCCB,AC,415volts, 160 Amp, 35/36KA,4 pole, with microprocessor release including making necessary connection in existing panel complete all as specified and directed.
41Supply and fix in replacement MCCB,AC, 415volts, 125 Amp, 16KA, 4 pole,with microprocessor release including making necessary connection in existing panel complete all as specified and directed.
42Supply and fix in replacement MCCB,AC, 415volts, 100 Amp, 16KA, 4 pole,with microprocessor release including making necessary connection in existing panel complete all as specified and directed.
43M&Lpreparation of existing old steel painted surface of panels by complete removal of paint of any size andany height , apply one coat of synthetic enamel paint inside and two coats on outside of panel (strictly existing shade) over a coat of red oxide zinc chrome primercomplete all as specified and directed.
44Taking down old un-serviceable panel of any type and size, Supply, install, testing & commissioning of CPRI approved powder coated LT panel board, outdoor type, floor mounted, factory made suitable for 415 volt, 3PH, 4 wire, 50 HZ, AC supply system having busbars chamber with copper bus bars400 Amps rating mounted on porcelain insulators. The panels shall be factory made, double door, made out of 3.15 mm thick MS Sheet (CRCA) totally enclosed dust, vermin & rust proof operated with front & rear opening with locking arrangement fixed with MS angle iron frame of size 40x40x6 mm mounted on angle iron legs made out of angle iron size 40mm x 40mm x 6mm , 1.0 mtr long, 0.50 mtr above ground level and 0.50 mtr embedded in PCC blocks (PCC 1:2:4 type B1) of size 0.30mtr x 0.30mtr x 0.50 mtr-04 nos including internal wiring with multistranded copper conductor cable of suitable size including lugs and cable gland to incoming and outgoing cable etc complete all as directedand comprising of the following :- (A) In Comming (i) MCCB four pole 415 volts AC supply 250 A thermal magnetic release type 35/36 KA-01 No(ii) Panel mounted digital multi function meter for measuring voltage(0-500) volts current (0-100 Amps) and frequency -01 No (iii) RYB neon indicating lamp (Set of three -01 No. (B) Out going : (i) MCCB four pole 415 volt 16 KA 125 Amp rating thermal magnetic release type-04 Nos. (ii) MCCB four pole 415 volt 16 KA 63 Amp rating thermal magnetic release type-01 Nos (iii) MCB SPN 240 volts 10 KA 20 Amp rating-02 Nos.
45Taking down old un-serviceable panel of any specification, Supply, installation, commissioning and testing powder coated LT feeder pillar box outdoor type of size 0.90mtr x 0.50mtr x 0.60 mtr factory fabricated made out of MS sheet of thickness 3.15 mm with front door openable with locking arrangement mounted on angle iron legs made out of angle iron size 40mm x 40mm x 6mm , 1.0 mtr long, 0.50 mtr above ground level and 0.50 mtr embedded in PCC blocks (PCC 1:2:4 type B1) of size 0.30mtr x 0.30mtr x 0.50 mtr-04 nos, with 200 Amp rated copper bus bar LED phase indicating lamp, suitable for 3 phase 4 wire supply system with MCCB 125 Amp 4 pole breaking capacity 25 KA-01 No, duly drilled holes for cable connection mounted on epoxy based post insulators all as required at site, complete all as specified and directed.
46M&Lwelding existing broken panel doors (any number of shutters) and welding good quality hinges (any size any number of hinges per panel) of suitable size for making open and close the panel doors including bends etc and fixing locking arrangement of the doors complete all as specified and directed.
47M&L Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead strip 25mm x 4mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth strip protected by galvanized iron 40 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc including taking out old un-serviceable earthing, complete all as directed by Engineer-in-charge. Note: (i) The concrete pit shall be PCC 1:3:6 type C-1, 40mm thick pre-cast cover slab of RCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate, reinforced with 8mm TMT bars @ 10 cm c/c on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No. 3 of MES SSR Part-I., (ii) Item includes the cost of GI pipe up to 7.5m GI for protection of earth strip & (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
48M&Linspection, checking and repair of APFC panel by cleaning of dust inside with blower, cleaning of moving part/contract from CT cleaner, tightening of loose parts/electrical wiring , cleaning of contractors, relays and capacitor juction points, oiling of cooling fan , complete testing of APFC relay with necessary settings with CTs /load adjustments to match with the APFC load management systemcomplete with replacement of burnt/worn out unserviceable components /burnt wires thimbles /lugs etc for APFC panel capcity 50 KVAR to 150 KVAR completeall as specified and directed. Note : All unserviceable parts shall be measured and paid seprately as supply only. Replacment of small nuts/screws, wires lugs or thimbles and cleaning material cost included in this item.
49SupplyonlyMCB, TP 6 to 32 Amp 10 KA C curve for existing APFC panel complete all as specified and directed.
50SupplyonlyMCB, TP 40 to 63 Amp 10 KA C curve for existing APFC panel complete all as specified and directed.
51Supplyonly Auxillary contractor 1 NO+1NC TP 415 volts suitable for 10 KVAR ratingfor existing APFC panel complete all as specified and directed.
52Supplyonly Auxillary contractor 1 NO+1NC TP 415 volts suitable for 20 KVAR ratingfor existing APFC panel complete all as specified and directed.
53Supplyonly capacitor 440 volts 50 Hz5 KVARfor existing APFC panel complete all as specified and directed.
54Supplyonly capacitor 440 volts 50 Hz 10 KVARfor existing APFC panel complete all as specified and directed.
55Supplyonly capacitor 440 volts 50 Hz 15 KVARfor existing APFC panel complete all as specified and directed.
56Supplyonly capacitor 440 volts 50 Hz 20 KVARfor existing APFC panel complete all as specified and directed.
57Supplyonly CT"s suitable for Ampere meter 100/5A ratiofor existing APFC panel complete all as specified and directed.
58Supplyonly CT"s suitable for Ampere meter 200/5A ratiofor existing APFC panel complete all as specified and directed.
59Supplyonly APFC relay square flush type with protection devices intelligent auto processor based on electronic controller unit 6 stagesfor existing APFC panel complete all as specified and directed.
60Supplyonly APFC relay square flush type with protection devices intelligent auto processor based on electronic controller unit 8 stagesfor existing APFC panel complete all as specified and directed.
61Supply only MCCB,AC,415volts,100 Amp, 25KA, 4 pole, fixed thermal magnetic release including making necessary connection in existing APFC panel complete all as specified and directed.
62Supply only MCCB,AC,415volts,160 Amp, 25KA, 4 pole, fixed thermal magnetic release including making necessary connection in existing APFC panel complete all as specified and directed.