| 1 | Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 2 | Excavation in trenches not exc. 1.5 Metre wide andn exc. 1.50 Metre in depth for laying of cables/foundation of poles and getting out in soft /loose soil complete all as specified and directed. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 Cm as in soft/loose soil complete all as specified and directed. |
| 4 | Removing excavated material (soils of any type) not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed. |
| 5 | Supply and laying dry coarse sand as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 Cm (15 Cm under the cable & 8 Cm over the cable) and gently punned down to 18 Cm thickness complete all as specified and as directed.Note:- Thickness after punning down shall be measured for payment. |
| 6 | Supply and laying in trenches Bricks, sub class \"B\" over burnt (kiln burnt) old size bricks, laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete all as specified and as directed. |
| 7 | Laying onlyin trenches Old serviceable bricks obtained from taking out old unserviceable XLPE cable, laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete all as specified and as directed. |
| 8 | M&L for Cutting roads / hard standing to a depth not less than 60 cm and not less than 45 cm wide for laying of GI pipe to draw the UG cable and making good the disturbed surfaces by filling of PCC (1:3:6) type C-2 using 40 mm graded stone aggregate and finished the surface even and smooth with out using extra cement and disposed off the surplus debris and soil to a distance not exc50 mcomplete all as specified and as directed. |
| 9 | M&LPlain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation base of poles and other similar locations complete all as specified and as directed. |
| 10 | M&L Plain cement concrete(1:3:6) type-C-2 using 40mm graded aggregatewith and including all necessary form work as in bases of pole complete all as specified and as directed. |
| 11 | M&L Plain cement concrete(1:2:4) type-B-1 using 20mm graded aggregatewith and including all necessary form work as in coping of pole complete all as specified and as directed. |
| 12 | M&L Rendering15mm thick in Cement Mortar 1:4 on other than fair faces of Brick Walls or on Concrete Surfaces, finishing plastered surfaces Even and smooth without using Extra Cement complete all as specified and as directed. |
| 13 | Taking out old U/S LT UG cable of any size and any description including GI pipe of any dia fixed with bldg and bricks for cable protection where ever appearedcomplete all as specified and directed.Note:- (i) Serviceable bricks obtained shall be stacked properly for re-use. (ii) Excavation and earth work shall be measured and paid separately under relevant item of these schedule. |
| 14 | Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 25 Sqmm 3.5 core in duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as specified and directed. |
| 15 | Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 35 Sqmm 3.5 core in duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as specified and directed. |
| 16 | Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 95 Sqmm 3.5 core in duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as specified and directed. |
| 17 | Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 120 Sqmm 3.5 core in duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as specified and directed. |
| 18 | Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 240 Sqmm 3.5 core in duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as specified and directed. |
| 19 | Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 185 Sqmm 3.5 core in duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as specified and directed. |
| 20 | Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 300 Sqmm 3.5 core in duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as specified and directed. |
| 21 | Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 400 Sqmm 3.5 core in duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as specified and directed. |
| 22 | Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 500 Sqmm 3.5 core in duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as specified and directed. |
| 23 | S&F Straight through joint kit heat shrinkable for LT 1100 Volts grade complete with jointing materials and accessories suitable for 3.5/4 core XLPEarmoured conductor cable of following sizes including testing of cable after joints complete all as specified and directed.(a) 25 to 50 Sqmm 3.5 core |
| 24 | All as per item No 24.00but70 to 150 Sqmm 3.5 core |
| 25 | All as per item No 24.00 but 185 to 300 Sqmm 3.5 core |
| 26 | All as per item No 24.00 but 300 to 500 Sqmm 3.5 core |
| 27 | S&F PVC cable terminal boxes, outdoor type of size 155mm x210mm x92mm with MCB SP 6 to 32 Amps including all necessary fittings and connection including taking down old unserviceable one complete all as specified and directed.Make:- HanselModel No. KF 1616G or equivalent model from Make:- Sitex/ Universal., Cape: TKPS1818-09H |
| 28 | S&F PVC cable terminal boxes, outdoor type of size 93mm x93mm x62mm including fixing with clamp including taking down old unserviceable one complete all as specified and directed.Make:- Hansel Model No. KF 0200B or equivalent model from Make:- Sitex/ Universal. Cape: ABOX040 |
| 29 | S&F Timer switch of Analogue typefor street light fittings, module 1 including taking down old unserviceable one complete all as specified and as directed.Make:- L&T Cat part No. AUTS01ANA00 or equivalent model from make:- Schneider / ABB / SIEMENS |
| 30 | S&F LED decorative post top lantern, 40 Watt capacity for energy efficient conservation upto 50% and with eco friendly lighting system with all accessories and necessary connection including taking down old unserviceable one complete all as specified and as directed.Make:- Havells cat part No. RUBYPT35WLED830PSYMTOPC or Surya Cat part No. SLE PT 40W-ETPP or Make:- Bajaj cat part No. BGCL 40W |
| 31 | S&F PVC insulated, stranded copper electric cable, 2.5 Sqmm2 core drawn into the steel tubular pole by drilling holes above the junction box and another holes near street light bracket including taking out old unserviceable copper wire complete all as specified and as directed. |
| 32 | S&F Land scape lighting 9/10 Watt ( LED Bollard) of IP 65 rated inverted pyramid type with soft 360º light distribution with necessary PCC base including necessary connection and all accessories including taking down old unserviceable one complete all as specified and as directed. Make:- Crompton cat part no. LBLSN 10 CDL or Make:- surya cat part no. SLE BL 9W-BLK800 or equivalent model from make:- Bajaj/ Havells. |
| 33 | S&F LEDsecurity light luminaries of 45W LED housing in high pressure die cast aluminium with heat sink with electrochemically brightened and anodized aluminium reflector, heat resistant toughened glass including necessary fixing arrangement with bracket made out of 40mm dia light grade GI pipe suitable for LED fittings duly grouted in walls and taking down the defective bldg security lights of any capacity complete all as specified and as directed.Make:- Crompton cat part No. LSTS-45-CDL or Make:- Bajaj Cat part No. ENXT 54L WH PO. or Make:- Surya cat part No. SLE UL 45W IP66 LXN |
| 34 | S&F LED Street light luminaries of 90W LED aerodynamically designedwith excellent thermal management inbuiltwith IP66 protectionfixed with bracket made out of 40mm dia light grade GI pipe bent to shape of 45º 1.5 m long inluding all accessories and necessary connection including taking down the defective bldg security lights of any capacity complete all as specified and as directed.Make:- Crompton cat part No. LSTP-90-CDL or Make:-Bajaj Cat part No. ZELZ P 108 L WH PO TG SD. or Make:- Surya cat part No. SLE UL 90W IP66 LXN |
| 35 | S&F LED flood light luminarie of 80 Watt capacity, pressure die cast with IP66 proction, efficient high output emitter LED including all accessories and neccsaary connection complete after taking down old unserviceable one complete all as specified and as directed by the Engr-in-Charge.Make:- Crompton cat part No. LFL-80-CDL/60-M or Bajaj- BJFL 80W LED I or Make:- Surya SLE FL 80W IP65 RFLOOD. |
| 36 | M&L Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.00 mm thick burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, GI strip proected by 40 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 cm c/c bothways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I complete all as specified and as directed.Note-: Excavation to be measuredand paid under sch item no- 1 above and PCC will be& paid under sch item no 10 above.contractor its following iteams have not been considered against items no-29 (i0 funnel with watering pipe,wire mesh and copper lugs. (ii) GI protector pipe (iii) Test point |
| 37 | Supply, installation testing and commisisioning feeder pillar box CPRI approvedof size 1.5 mtrX1.2 mtrX.60mtr outdoor type confirming to IP-54, factory made double door both front and back side, with locking arrangement prewired made out of 3mm thick MS sheet with 04 Nos legs, MS angle iron 40x40x6mm size 0.9mtr long suitablegrouted in ground with PCC 1:3:6 type C2 and cement plaster 1:4including two coats or synthetic enamelled paint over a coat of red oxide primer both internally & externally and including S&F aluminimum bus bar 600 amps rated duly coloured coded 04 Nos and connection through aluminium busbar of suitable size to MCCBs. MCBs and power contactor and accessories fitted in it for incoming and out going cable, including LCD multi function meter for measuring voltage ampere, frequency, KW,KWH,, Phase indicating lamps LED type RYB duly fitted in Panel and all the acessroies to be connected with suitable copper conductor (control wiring) and power connection with busbar, connection of cable with necessary lugs, glands, PVC tape after taking down old unsrviceable feeder pillar box complete all as directed by Engineer-in-Charge.(i) MCCB, 400 Amps, 4 pole, 415 volt, 25 KA fixed thermal and magnetic setting - 01 Nos(incoming).(ii) MCCB, 100 Amps, 4 pole, 415 volt, 25 KA fixed thermal and magnetic setting - 04 Nos(out going).(iii) MCB 32 Amp FP B curve- 2 Nos (out going)(iv) LCD Multifunction meter with CT -1No(v) Phase indicating Lamps LED type RYB complete - 01 Set(vi) Analog type time switch FM/1 QUARTZ type QT(daily) voltage 240 V, contact ratings 16A, 250V AC (resistive)single phase.. Make L&T cat no AUTS01AN00 -1 no(vii) Modular contactor 40A-4 NO, 3 module Make L&T cat no AUMC2004003 -1 noNote-: Drawing shall be submited by the contractor before manufacturing for approval of accepting officer. |
| 38 | S&F MCCB 4 pole 630A, 50KA, 415V thermal and magneticadjustable type including making all fixing arrangement, cutting welding of existing panel board as per site requirment and painting the disturbed part of panel as per the existing colour of the paneland electric connection including taking down old one complete all as specified and directed. Make:Havells Cat Part No. IHLFNF0200 #or L&T Cat Part No.CM92109OON1OG |
| 39 | S&F MCCB 4 pole 500A, 36KA, 415V thermal and magneticadjustable type including making all fixing arrangement, cutting welding of existing panel board as per site requirment and painting the disturbed part of panel as per the existing colour ofthe paneland electric connectionincluding taking down old one complete all as specified and directed. Make:Havells Cat Part No. IHLFNF0200 #or L&T Cat Part No.CM92109OON1OG |
| 40 | S&F MCCB 4 pole 400A, 36KA, 415V thermal and magneticadjustable type including making all fixing arrangement, cutting welding of existing panel board as per site requirment and painting the disturbed part of panel as per the existing colour of the paneland electric connectionincluding taking down old onecomplete all asspecified and directed . Make:Havells Cat Part No. IHLFNF0200 #or L&T Cat Part No.CM92109OON1OG |
| 41 | S&F MCCB 4 pole 350A, 36KA, 415V thermal and magneticadjustable type including making all fixing arrangement, cutting welding of existing panel board as per site requirment and painting the disturbed part of panel as per the existing colour ofthe paneland electric connectionincluding taking down old one complete all as specified and directed.Make:Havells Cat Part No. IHLFNF0200 #or L&T Cat Part No.CM92109OON1OG |
| 42 | S&F MCCB 4 pole 250A, 36KA, 415V thermal and magneticadjustable type including making all fixing arrangement, cutting welding of existing panel board as per site requirment and painting the disturbed part of panel as per the existing colour ofthe paneland electric connectionincluding taking down old one complete all as specified and directed. Make:Havells Cat Part No. IHLFNF0200 #or L&T Cat Part No.CM92109OON1OG |
| 43 | S&F MCCB 4 pole 200A, 36KA, 415V thermal and magneticadjustable type including making all fixing arrangement, cutting welding of existing panel board as per site requirment and painting the disturbed part of panel as per the existing colour ofthe paneland electric connectionincluding taking down old one complete all as specified and directed. Make:Havells Cat Part No. IHLFNF0200 #or L&T Cat Part No.CM92109OON1OG |
| 44 | Supply and erecting steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts and screw as specified, type 410 SP-31, 9 Metre long including two coats of aluminium paint over one coat of red oxide primer with dismantling of old unserviceable pole and PCC complete all as specified and as directed by the Engr-in-Charge. Note:- Rates quoted shall be deemed to be inclusive of following works:-(a) Material and labour for painting of pole externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coats of aluminium paint over a coat of red oxide primer including preparation of surface. (b) Material and labour for writing letter or figures (Block, Roman, Italic as Indian) with thick synthetic enamelled paint of apprised shade n exc 5 Cm height including numbering of pole all as directed by EIC. |
| 45 | Material and labourPreparation of old painted surface of existing steel tubular swaged pole 9 mtr long, cross arms, clamps, GI street light bracket etc and applying two coats of aluminium paint including writing pole number & bottom of pole painted with black paint with yellow strip around between the junction of aluminium paint and black paint complete all as specified and directed. |
| 46 | Material and labourDanger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15Cm size including taking down old unserviceable Danger notice plate complete all as specified and directed. |
| 47 | Taking downold aluminium strip/ GI strip of any size and refixing the same with new saddles ,clamps,screws etcto its original position complete al las specified and as directed. |
| 48 | S&F Aluminium strip 25x3.15mm with saddles and fixing screws etc for roof conductors and down conductors above ground incl taking down old unserviceable one complete all as specified and as directed. |
| 49 | S&F Air termination aluminium single pointed rod 12 mm dia, 300 mm long as in repair complete all as specified and as directed. |
| 50 | S&F Test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 3 nos 8mm dia 25mm long hex head screwas in repair complete all as specified and as directed. |
| 51 | S&F Flexible PVC pipe of size 25mm suitable for electric connection including taking out old unserviceable PVC pipe.complete all as specified and as directed. |
| 52 | Supply and Laying Steel Water Tubing100mm Bore (dia), Galvanised, ‘Light Grade’ with all Fittings, laid in trenches for laying of cable complete as all specified and as directed. |
| 53 | Supply and Laying Steel Water Tubing 80mm Bore (dia), Galvanised, ‘Light Grade’ with all Fittings, aid in trenches for laying of cable complete as all specified and as directed. |
| 54 | Supply and Laying Steel Water Tubing 50mm Bore (dia), Galvanised, ‘Light Grade’ with all Fittings, aid in trenches for laying of cable complete as all specified and as directed. |
| 55 | S&F Asthetically designed decorative hot dippedblack painted galvanised mild steel pole different section and gold colour painted decorative rings for street light / security light including taking down old unserviceable street light pole, complete all as specified and as directed Make:-Havells cat part No. 6MPE or equivalent model of Crompton / Bajaj Cat no- BJPL01400/ Surya |
| 56 | S&F junctionpole box made of high quality thermoplastic polycarbonate (shock proof ,rust free,corrosion free,acid and chemical resistant,fire retardant,having high impact strength, of IK 9, made of halogen and silica freerecyclable material IP66/67 degree of protection UV resistant, having high graded internally embeddedgasket made of poly urethane should withstand glow wire test at 960 degree centigrade should be flame retradantand self extingushing with switch gear assemblies as per IEC-439-1 the junction box should have 4 power terminal of 25 /35 Sqmm and earth terminal along witha SP MCB of 6 Amp fitted in itthe dimension of box shall be 254 x 180 x 90 in mm (LxHxD) and fixing to tubular /PCC pole using MS flat of size 25x3mm with suitable nuts and bolds after taking down old unserviceable one complete all as specified and as directed.Make - CAPE electric TK PS 2518-9 cat No- CJB009PS/HENESEL/SINTEX / L&T. |
| 57 | S&F Changeover Switch for bldg lift services, in sheet steel enclosure, four pole,500 Amps, Manual type, 415 V after taking down old unserviceable one complete all as specified and as directed. Make: L&T Cat Part No. CO32500OSOO orMake: Havells Cat part No. IHCNFE0250 |
| 58 | S&FChangeover Switch for bldg lift services, in sheet steel enclosure, four pole,400 Amps, Manual type, 415 Vafter taking down old unserviceable onecomplete all as specified and as directed.Make: L&T Cat Part No. CO32500OSOO orMake: Havells Cat part No. IHCNFE0250 |
| 59 | S&F Changeover Switch for bldg lift services, in sheet steel enclosure, four pole,250 Amps, Manual type, 415Vafter taking down old unserviceable onecomplete all as specified and as directed.Make: L&T Cat Part No. CO32500OSOO orMake: Havells Cat part No. IHCNFE0250 |
| 60 | S&F Aviation obstruction light in yellow coloured die cast aluminium alloy housing with heat resistant, clear thick glass dome mounted on hinged die-cast aluminium ring secured to the body by two studs and wing nuts with neon spiral lamp plugged into spring loaded high tension nylon socket and wired upto the terminal block having degree of protection- IP 54 including dismantling and taking down existing unserviceable/worn out aviation light from RCC over head tank of height not more than 21.0 Mtr complete all as specified and directed.Make-BAJAJ Cat part No BGAV302 LED with neon lampor equivalent model in Philips / Wipro |
| 61 | M&LACP base with LG/Retrohigh Glow vinyl sign board along withGI pipe bracket with accessories including 0.20mm thick white rubber coated vinyl or synthetic vinyl I sheet painted with scotch / computer inject printing with outdoor ink and with 300x 720 DPI and also 140 DPI laminated with average 0.15mm high quality weather protected with chemical and including 1.5mm thick poly carbonated PVC milky / transperent sheet drawing art work computer designing including 22 SWG sheet frame work arrangemet for fixing LED tube light fittings 18/20 watt -01 No per sqm with necessary connection with 1.5 sqmm single core copper conductor cable and 50mm bore light grade pipe 3Rm- 2 nos duly grouted deep in PCC type B@ ( 1:2:4, using 40mm graded crushed stone aggregates) including all necessary fixing arrangement & tools and plantsincluding taking down old unserviceable glow sign board complete all as directed by engineer-in-Charge. |
| 62 | Taking down defective existng LED street light /LED security light fitting of any type and any capacity from any height of pole / any place and refitted the same in position after necesssary fault finding / repair /replacement the defective components and making connection with copperwire 1.5 sqmm and PVC connector block and testing complete all as specified and directed.Note : LED driver shall be measured and paidseparately as supplied against respective items. |
| 63 | Supply onlyconstant current LED driver operating voltage 180v-270v AC 50/60 HZ out put voltage 36V DC/2.8 Amp power factor 0.95 Make- Bajaj cat No BGD36 240 5Y or equivalent make philips/CG etc. |
| 64 | Routine and periodical cleaning the inside area of Sub Stations including cutting and removal/uprouting of unwanted grass/bushes, small trees near all around LT panel/ poles and pump houses complex etc complete including surface dressing and leveling by surface excavation wherever as required or as directed. |