| 1 | Taking down cement or lime plaster in patches of any description from stone or brick wall or concrete surfaces of ceilling etc including raking out joints, hacking for key scrubbing down with water and disposing off the rubbish materials where directed at low lying areas in Defence land complete all as specified and directed. |
| 2 | M&L rendering 15mm thick plaster on fair faces of brick or concretesurfaces in CM 1:4 with WPC finished the surface even and fair without using extra cement complete all as specified and directed (WPC shall bemixedat 3%by weight of cement and rate for the same is included in quoted rate. ). |
| 3 | M&L rendering 15mm thick plaster on fair faces of brick or concretesurfaces in CM 1:6 with WPC finished the surface even and fair without using extra cement complete all as specified and directed (WPC shall bemixedat 3%by weight of cement and rate for the same is included in quoted rate. ). |
| 4 | M&L rendering 5mm thick plaster on ceiling,soffits of slab etc in CM 1:3 finished the surface even and fair without using extra cement complete all as specified and directed |
| 5 | M & L preparation of new plastered surfaces of wall and applying two coats of oil bound distemper complete all as specified and directed. |
| 6 | M &Lfor preparing new plastered surface of wall and applying two coats of cement base paint over a coat ofprimer complete all as specified and directed. |
| 7 | M & L preparation of new surfaces of ceiling and applying three coats of white wash complete all as specified and directed. |
| 8 | Dismantling ofceilling boards in any type size or shape fixed with nails to timber frame work or in angle iron / aluminium grid complete all as specified and directed. |
| 9 | M & L 4mm thick Non asbestosfibre cementbuilding boards, fixed or laid/ inserted to timber/GI/ Aluminium frame work with screw as in ceilings complete all as specified and directed. |
| 10 | S&F in repair Aluminium body ( extruded section) Door closure hydraulically regulated designation no.3 universal type suitable for door shutters of 851to 1000mm in width and weight between 61 to 80 Kg and fixedcomplete all as specified and directed. |
| 11 | S&F in repairdouble action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminiun alloy sheet foundation box , main body with stainless steel cover governing pivot made of brass , other parts made of mild steel heavy duty complete all as specified and directed . |
| 12 | S & F in repairs for mortice latch with two levers (vertical type),100 mm long latch aluminium anodised body complete all as specified and directed . |
| 13 | S&F in repair 100 mm longbutt hinges extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixedcomplete all as specified & directed |
| 14 | S&F in repair 150 mm long aluminum handle febricated type anodised.complete all as specified & as directed. |
| 15 | S & F in repairs 150 mm long aluminium anodised barrel tower bolts of extruded section complete all as specified & as directed. |
| 16 | S&F in repairs 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified & as directed. |
| 17 | S & F 3 mm thick plain sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane including hackingdown old broken glasses complete all as specified & as directed. |
| 18 | All as per item no 17.00 here-in- beforebut frosted glass. |
| 19 | S & F in repairs aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified & as directed. |
| 20 | Supply & fix in repairs curtain rods of aluminium annodisedfixed alongwithbracketsto walls with PVC rawal plugs complete all as specified & as directed. |
| 21 | Taking up or or down 15mm bore steel tubing and connections including cleaning for refixing or removal to store complete all as specified & as directed. |
| 22 | S&F15mm bore Galvanized steel tubes, medium grade for flush pipes, water supply pipes etc, fixed to walls and ceillings or laid in floors |
| 23 | Taking up or or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified & as directed. |
| 24 | S&F20 mm bore Galvanized steel tubes, medium grade for flush pipes, water supply pipes etc, fixed to walls and ceillings or laid in floors |
| 25 | S&F in repairs plastic water closet seat, of white colour, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified & as directed. |
| 26 | S &F in repairs 10 Ltr capacity PVC valveless symphonic action type flushing cistern, low level with inlet, ball valve, float all as specified including necessary flush pipe complete all as specified & as directed. |
| 27 | S & F in repairs15 mm dia PVCconnection 450 mmlong with PTMT nuts and washers complete all as specified & as directed. |
| 28 | S & F for urinal water spreader of PTMTwith 15 mm dia pipe fixed to bowl complete all as specified & as directed. |
| 29 | S&Fin repairs stainless steel tubular towel rail, 20mm dia, D type, 60cm long between flanqes complete all as specified & as directed. |
| 30 | S&F in repairs600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup wasners complete all as specified & as directed. |
| 31 | S &Fin repairs 15 mmbore pillar taps, fancy type long body cast copper alloy, with capstan heads, chromium plated, screwed down high pressurewith long screwed shanks and fly nuts screwwed for iron pipe complete all as specified & as directed. |
| 32 | S & F in repair 100mm to 125mm bore mild steel chromium plated grating fixed on floor trap/ nahni trapwith white cement all aroundcomplete all as specified & as directed. |
| 33 | S & F in repairs 15 mm bore fancy type long body chromium plated bib taps screwed down, screwed for iron pipe or for brass ferrule complete all as specified & as directed. |
| 34 | S & F in repairs 15mm bore stop valve cast copper alloy chroumium plated screwed down high pressureconcealed typescrewed both ends for iron pipe or for unions complete all as specified & as directed. |
| 35 | S&F in repairs CP shower rose 75 mm dia with or without swiveljoints any size, including fixing to steel pipe or unioncomplete all as specified & as directed. |
| 36 | S &F in repairs 20mm dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified & as directed. |
| 37 | S & F health faucet (ABS body ) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 m long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified & as directed. |
| 38 | S &F rotational moulded polyethylene water storage tank 500 Ltr capacity (Cylindrical vertical with closed top) triple layeredconstuction ISI marked hoisted and fixed in positionas specified in SSR part-Iincluding tank nipple. including dismantling old unserviceable tank complete all as specified and directed. |
| 39 | S &F rotational moulded polyethylene water storage tank 1000 Ltr capacity (Cylindrical vertical with closed top) triple layeredconstuction ISI marked hoisted and fixed in positionas specified in SSR part-I including tank nipple. including dismantling old unserviceable tank complete all as specified and directed. |
| 40 | Cleaning and removing all scales, loose dirt etc. from water tank of capacity n.exc 500 ltrs and mouth of circulating pipesincluding removal of float valve and tank nipple and re fixing after cleaning complete all as specified and directed. |
| 41 | Cleaning and removing all scales, loose dirt etc. from water tank of capacity1000 ltrs and mouth of circulating pipesincluding removal of float valve and tank nipple and re fixing after cleaning complete all as specified and directed. |
| 42 | Cleaning of sewage lines of 100 mm dia size by rodding and cleaning with gunny bags / cotton rags etc tied with rod for removal of complete sludge in the line from manhole to manholecomplete all as specified and directed |
| 43 | All as per item No 42.00 here in beforebut for 150 mm dia sewage lines. |
| 44 | Cleaning of manholes after all the sludge of blocked lines comes into the manhole n.exc 1.50 mtr deep and getting out including removal of sludge to a distance n exc 50 m complete all as specified and directed. |
| 45 | All as per item No 44.00 herein beforebut depth exc 1.50 mtr deep and n. exc 3.00 m deep. |
| 46 | NOTE :-The rates quoted by the tenderer ( FromItem No 1 to 45 above ) shall deemed to be inclusive for the following provision in addition to the other conditions specified in the tender documents. No claim whatsoever shall be entertained at a later date on this accoun t:-(i) The repairs shall be done by skilled workmen in the relevant field to the entire satisfaction of Engineer-in-Charge. The contractor shall engage sufficient manpower for the entire tender period so that progress of work shall not be hampered due to non availability of labour atworking Hrs .(ii) The contractor on getting information through complaint cell of GE(P) Varsha Rambilli regarding the nature of repair to be carried out, he shall immediately respond to the same and make all out efforts to carry out the same on priority within 48 hours. In case of any delay in responding/attending the repairs within 48 hours, the AGE may at his absolute discretion impose penalty on the contractor at Rs. 100/- per day per each complaint upto 05(Five) days and Rs. 200/- per day thereafter till completion of the work in case of delay eithout valid reasons as decided by AGE and approved by GE(iii) Further, the above penalty is applicable even for the multiple locations of work at the same period. It is the responsiblity of contractor to make suitable arrangements for attending the repairs simultaneously at all the places.(iv) The decision of the AGE as to whether a particular repair has been attended ar not on a particular day will be final and binding. the above penalty shall be in addition to the provisions made in clause 50 of IAFW-2249 i.e (Compensationfor delay in completion of work). |
| 47 | Taking out liquid/solid content from sump/septic tank/filter bed/soakage well and sewage lines by sewage sucker tanker & cleaning thoroughly including disposal of liquid/solid content out of the defence land complete all as specified and directed |
| 48 | Demolition of unreinforced concrete in ground floors and pavingsexc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 49 | M&L 100 mm thick PCC (1:4:8) type D-2 using 40 mm graded aggregates in subase complete all as specified and directed |
| 50 | M&L for 75 mm thick cement concrete 1:3:6 type C -2, using 40mm graded stone aggregate as in plinth protection laid to slop of 1:12, finished surface even and fair without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 6 mm wide joints through out the thickness of plinth protection duly filled with mastic filling (one part of hot bitumen 85/25 and three part of fine sand by wight complete all as specified and directed.) |
| 51 | M&L forprovidng 40mm thick cement concrete 1:2:4 type B-2, using 40 mm graded stone aggregate as in road/ path, hard standing etc.with and including all necessary form work to divide the area in panels. |
| 52 | M&L cement concrete chequrred tiles of size 25cmx25cmx22mm thick machine pressed , set and jointedand pointed in neat cement slurrywith grey cement and pigments including 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 53 | M & L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade includinglaid over 25 mm thick sand cusioning in pattern with grey cement and pigment complete all as specified and directed. |
| 54 | Demolition of brick work or stone/ boulder masonary,built in cement mortar including all quoins, pillars etc.complete all as specified and directed. |
| 55 | M & L for PCC Pre-cast cement concrete block masonry of 1:3:6 of mix set in CM 1:6with solid blocks, exc. 10 cm in width and setting in mortar,complete all as specified and directed. |
| 56 | M&L walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM1:6 complete all as specified and directed. |
| 57 | M & L for 1:2:4 type B-1 using 20 mm graded aggregate as inin lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbswater troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 58 | Dismantling posts or struts(wood, steel or R.C.C.) any section,embedded in concrete, brick work,masonary etc including taking out embedded portion and making good disturbed ground complete all as specified and directed. |
| 59 | M & L for angle iron as inrunning bars, fordoors, balusters, nosing to stepsincluding beding in concreteand screwing etc. wind ties forroof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed |
| 60 | M & L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete including dismantling of old unserviceable steel gate/sections complete all as specified and directed. |
| 61 | M&L for providing plain cement concrete, type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. |
| 62 | S & F4mm dia galvanised steel wire, 150x100mm mesh, made up into mattresses or cages, lapped, wired and laid in position, including closing after filling complete all as specified and directed. |
| 63 | M&Lpreparation of new or previously untreated surface of steeland iron work of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of red oxide primer complete all as specified & as directed. |
| 64 | Demolition of reinforced cement concrete in any position and any description including cutting of reinforcenent bars to facilitate demolition complete all as specified and directed. |
| 65 | M & L for nominal mix concrete 1:2:4 type B-1 using 20 mm graded aggregate concrete as in walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and directed. |
| 66 | M & L for nominal mix concrete 1:2:4 type B-1 using 20 mm graded aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass complete all as specified and directed. |
| 67 | M&L for precast RCC slab nominal mix concrete 1:1.5:3 type A-1 using 20 mm graded aggregates set in CM(1:6) complete all as specified anddirected. |
| 68 | M & L for formwork to sides of concrete for fair finished surfaces foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified anddirected. |
| 69 | M & L for fair finished surfaces offormwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter |
| 70 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or secuing with clips complete all as specified and directed. |
| 71 | M&L for mild steel TMT bars6 to 8 mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or secuing with clips complete all as specified and directed. |
| 72 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in Hard/dense soil complete all as specified and as directed |
| 73 | M&Lfor PCC 1:4:8 type D2 using 40mm graded aggregates as in foundations, filling and mass concrete complete all as specified andas directed. |
| 74 | M&L for Reinforced cement concrete ( Nominal mix) 1:1.5:3 type A 1using 20mm graded aggregates as in foundations, including rafts, footings, foundation beams, plinth beams, basement slabs, under-reamed piles and mass concreate complete all as specified and directed. |
| 75 | M&L for Reinforced cement concrete( Nominal mix) 1:1.5:3 type A 1 using 20mm graded aggregates as in walls, retaining walls, basement walls , ballast walls and the like any thickness above top of footings, including attached pilasters and buttresses complete all as specified and directed |
| 76 | S&F 100mm diaUPVC pipes(SCH-40) including for jointing and jointing materias complete all as specified anddirected |
| 77 | M&L for returning filling in including spreading levelling watering and well ramming in soft/loose soilcomplete all as specified anddirected |
| 78 | M&L for removing excavated soil material exc 250m but not exc 500m and depositing where directedcomplete all as specified anddirected |
| 79 | Total Amount in Figures |
| 80 | Quoted Amount in Words |