Public Administrative Department Government Departments Closing in 0 days TDR #34525050

Tender For Provision Of Lighting Arrangement At Slf Ghazipur

Issued by Government Departments · Shahdara, Delhi
Tender Value
41.86 Lakhs
Estimated cost
Bid Submission
05 Nov 2022
0 days left
EMD
84000
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Shahdara → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Provision Of Lighting Arrangement At Slf Ghazipur

BOQ

Name of Work: Provision of lighting arrangementat SLF Ghazipur.
Sl. No. Item Description
1Fabrication, supplyof following size 11 mtr RCC/PSC pole with carbon steel based fabricaton of minimum tensile strenth of 200 kg. with botton width of minimum 415 mm and top width of minimum 225 mm, including all accessaries hook etc as required for laying of min 300 sq mm cable.
2Supply and fixing of galvanized steel stay wire of size - 12 mm dia used for sustaining mechanical load of cable of minimum 3.5x300 sq mm cable size etc as required.
3Supplying and erection of galvanised \"D\" iron clamps complete with shackle insulator (100 mm X 110 mm),G. I. bolts, nuts and washers, coach screws etc. as required.
4Erection of RCC/ PCC pole of following length in brick ballast and ramming thefoundation, finishing with 150mm thick cement concrete (1:3:6) layer on top withincluding excavation and refilling etc as required. Above 8.0 metre and upto 11.0 metre
5Fabrication , Supplying,Installation,testing,Commissioning of 12 mts.high mast System with its accessories ,Mast shaft shall be in one section , hot dip galvanized 4mm thick(Single dip ) inside and out sides and suitable for wind velocity as per IS 875 part3 .There shall be in longitudinal seam weld per section and No circumfrential weld. It should also included accessories For High Mast head frame ,2 point suspension system with steel wire rope 5mm dia. (7/19construction) single drum winch ,galvanized lantern carriage arrangement suitable for 4/6 Nos. flood lightluminaries symmitrically And its control gears boxes and lighting finial ,the mast shall have integral manual type mounted at the base compartment of its raising and lowering operation with foundation bolts and Anchor plate and control panel housing suitable RCC(1:2:4) shallow foundation of size 1m(L)x1m wide and 2 mtr deep I/C excavation of earth , providing cutting,bending and placing in position ,reinforcement of cold twisted bars of 12 mm dia -2100 mm long(approx)-16 nos and reinforcement of cold twisted bar of 8mm dia -3700 mm(approx) -13 nos (with 150mm spacing) as reqd with positioning of foundation bolts and providing DWC HDPE pipe for cable entry or exit as required for the high mast considering the safe soil bearing capaciy at site as 10T/sqm at 2 mts .Depth with all material i/c 4 Nos S.P MCB ,63 A Dp Isolator etc as reqd Logo/Name of manufacturer shall be embossed on the pole. Galvanization as per relevant IS
6Supply and fabrication of pole protection system made up of 8SWG steel wire mesh of size25mmx75mm rectangular with 50mmx50mmx6mm MS angle iron for supporting the mesh and grounding the protection system in suitable quality of CC etc as reqd.
7supply of XLPE Insulated PVC Sheathed Al. Conductor Armoured Cable for working voltage upto 1.1kV confirming to IS-7098 of following sizes: (a) 2x10 sqmm
8(b) 4 x 25 sq.mm
9\"SITC of 150w LED Flood Light luminiare fitted with lens, madeof pressure die cast aluminum housing & toughened glass cover complete with the following specification as reqd. (a) Total system wattage = 150 watt+/-5% (b)Total Lumens output>=15000 lumens (d)Luminaire Efficacy>=100 Lm/w(e) power factor>=.95(f) Protection Class-IP-66
10Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
11Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nutbolt & spring washer spaced at 50mm)
12Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sqmm FRLS PVCinsulated single core cable as earth wire in existing surface/ recessed steel/PVCconduit including dismantling as required.Group C
13Supply of 250 mm (10\") sweep 1250 RPM erxhaust fan, fresh air type complete with shutter blades etc as required.
14SITC of surface mounting LED luminaire suitable for 1X20 watt LED rating box type complete with extruded aluminium batten prewired with high efficient LEDs with the following: a) Total System Wattage 20 ±5% Wattb) Luminaries effucacy = 100 lumens/watt c) Power factor = 0.95
15\"SITC of 350 W LED Flood Light luminiares having with high efficient LEDs and secondary Optics (PC lenses ), housing made of PDC with IP 66, 130 lumens per watt LED chip efficiency. PF > 0.95 , CCT 5700 K-6000K, Internal SPD > 5kV and external SPD = 10kV, Operating voltage rate - 100 v to 300 V , 50 Hz AC.TOTAL SYSTEM WATTAE 350+/-5%
16Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan withBrush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos.blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM,350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc.complete as required.
17S I T C of Hot Press moulded SMC panel/Canopy Box of size(OD) 920 mmx460 mmx260 mm & (ID) 900 mmx450 mmx250 mm , anti- corrosive, dust proof , rust proof, shock proof , Self-extinguishing property , resistant to heat, Vermin proof, Ultra Violet stabilized , Pilfer resistant, Suitable for mounting 1 no 3 phase Energy meter , socket for outgoing connection with pilferage proof SMC door duly welded with S/S handle having danger logo on its outer surface and with 1 no Hot Dip galvanized iron stand for base of size 40 mm x 40 mm x 5 mm and height of the stand is 600 mm including 300 mm height below the ground with side strip of size 25 x 5 mm
18Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminalspreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 100 A, 16 KA,TPMCCB
19125 A, 16 KA,TPMCCB
20Supplying and fixing following rating, four pole, (three phase and neutral),240 V, residual current circuit breaker (RCCB),having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) 63 Amp.
21Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way double door
228 way, Double door
23Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
24Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
25Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
263 pin 5/6 A socket outlet
2715/16 A switch
286 pin 15/16 A socket outlet
29Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
30P/FHot press sheet mouldedcompound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof polebox of innerdimension 2000x160x98mm (NS) complete with suitable arrangment for fixing of1nosof 6 to 32 amp single pole MCB & 63 Amp. Doublepole isolator (MCB/Isolator excluded) withneutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plateofsuitable size with danger monogram property printed on the coveretc asreqd.( Without MCB)
31Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the exisiting surface/recessed steel/PVC conduit as required (a) 3x2.5 sq mm
32(b) 3x4 sq mm
33© 3x6 sq mm
34Laying and fixing of one number PVC Insulated and PVC sheathed/XLPE cable of 1.1 KV grade of following size in the existing masonary open duct as requiredupto 35sqmm

AI Tender Summary

OUR REF NO 34525050
AUTHORITY Government Departments
TENDER VALUE 41.86 Lakhs
LAST DATE 05-11-2022
Authority
Authority Name East Delhi Municipal Corporation
Work Description Provision Of Lighting Arrangement At Slf Ghazipur
Basic Detail
Tender No EE-EandM/EDMC//2022-23/13.1
Bidding Type Tender
Location
City Shahdara
State Delhi
Key Dates
Publish Date 25 Oct 2022
Submission Date 05 Nov 2022
Open Date 07 Nov 2022
Finance
Tender Value 41.86 Lakhs
Tender Fee 1000
EMD 84000
Exemption Not Available
Document List
b9686f88-c267-494b-96f7-0e31a9d63e8c.html
BOQ_145797.xls
condition1.pdf
Generalcondition.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 25, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 05, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Nov 07, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

b9686f88-c267-494b-96f7-0e31a9d63e8c.html

xls

BOQ_145797.xls

pdf

condition1.pdf

pdf

Generalcondition.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders