Housing Urban and Rular Development Boards / Undertakings / PSU Closing in 0 days TDR #34520413

Tender For Constuction Of Health Sub Center And Health Wellness Center At Vill- Gadhi Baroli, Block-Jaitpur Kalan , Distt. Agra

Issued by Boards / Undertakings / PSU · jaitpur, Uttar Pradesh
Tender Value
25 Lakhs
Estimated cost
Bid Submission
08 Nov 2022
0 days left
EMD
50000
Bank guarantee accepted
Document Fee
1770
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
jaitpur → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Constuction Of Health Sub Center And Health Wellness Center At Vill- Gadhi Baroli, Block-Jaitpur Kalan , Distt. Agra

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 31-Oct-2022 2200/ENG-24/84 DATE 31/10/2022 Technical Bid 08-Nov-2022

BOQ

Name of Work: Construction of health sub Center and wellness Center at Village - Gadhi Baroli, Block-Jaitpur Kalan , Distt. Agra
Sl. No. Item Description
1Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m.(5 fts.) and lead upto 30m.(100 fts.) & including filling. watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-incharges upto a distance of 30 m.(100 fts.) from the foundation trenches.
2Earth work in filliing in plinth in ordinary soil including cutting of earth, cartage up to 4 Km, loading , unloading,filling of carted in plinth by head loadof earth and cost of earth including leveling dressing and watering and also including labour , T&P etc.Required for proper completion of the work.
3Sand filling in plinth includingsupply of necessary quantity of sand from a distance not excceding 8 km. (5 miles) from the site of work and including watering, ramming,dressing etc. rate to including cost of all materials, labour and T & P etc. required for proper completion of the work
4Providing and laying Cement concrete 1:4:8 (1 cement : 4coarse sand : 8 graded stone ballast 40 mm nominal size) including supply of all materials.labour and T&P etc. required for proper completion of the work and curing complete. also including cost of formwork in foundation.
5Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313(PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4) Treatment of soil along external perimeter of building 7.5 liters/sqm.(5) Treatment of soil under apron along external perimter 5 liters/sqm.
6Class - 150 brick work in cement and coarse sand (FM 1.50 to 2.20) mortar in proportion of 1:6in foundation and plinth including supply of all materials, labour and T&P etc. Required for proper completion of the work.
7Class - 150 brick work in cement and coarse sand (FM 1.50 to 2.20) mortar in proportion of 1:4in foundation and plinth including supply of all materials, labour and T&P etc. Required for proper completion of the work.
8Class - 150 brick work in cement and coarse sand (FM 1.50 to 2.20) mortar in proportion of 1:6 in super structure for one brick thick wall including necessary cutting & moulding of brick as required and also including honeycomb brick work including supply of all material, labour T&P etc. Required for proper completion of the work.
9Class - 150 brick work in cement and coarse sand (FM 1.50 to 2.20) mortar in proportion of 1:4 in super structure for half brick thick wall including necessary cutting & moulding of brick as required and also including honeycomb brick work including supply of all material, labour T&P etc. Required for proper completion of the work.
10R.C.C. work with cement approved coarse sand and 2 cm. (3/4\") gauge approved stone ballast in the proportion of 1:1.5:3 (M-20) in raft foundation and footing excluding supply of reinforcement and its binding but B.W.G.G.I. binding wire and including necessary centering and shuttering etc. and also including supply of all materials, labour and T & P etc.required for proper completion of the work. Binding wire cost being included in the item
11R.C.C. work with cement approved coarse sand and 2 cm. (3/4\") gauge approved stone grit in the proportion of 1:1.5:3 (M-20) in plinth Band & lintels of doors and windows excluding supply of reinforcement and its binding but B.W.G.G.I. binding wire and including necessary centering and shuttering etc. and also including supply of all materials, labour and T & P etc.required for proper completion of the work. Binding wire cost being included in the item
12R.C.C. work with cement approved coarse sand and 2 cm. (3/4\") gauge approved stone grit in the proportion of 1:1.5:3 (M-20) in beams excluding supply of reinforcement and its binding but B.W.G.G.I. binding wire and including necessary centering and shuttering etc. and also including supply of all materials, labour and T & P etc.required for proper completion of the work. Binding wire cost being included in the item
13R.C.C. work with cement approved coarse sand and 2 cm. (3/4\") gauge approved stone grit in the proportion of 1:1.5:3 (M-20) in slab excluding supply of reinforcement and its binding but B.W.G.G.I. binding wire and including necessary centering and shuttering etc. and also including supply of all materials, labour and T & P etc.required for proper completion of the work. Binding wire cost being included in the item
14RCC work with cement, approved coarse sand (Fm 2.20-3.60) and 2cm gauge approved stone grit in proportion of 1:1½:3 in Coloumn excluding supply of reinforcement and its bending but including its fixing & binding with 24 B.W.G.G.I. binding wire, and including necessary centering and shuttering etc. and also including supply of all materials, labour, T&P etc. Required for proper completion of the work/ strength of the concrete shell not less than M-20 grade. ( SI No 289)
15Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and wastage & over lapping & hooks.
16Supply of M.S angle iron chaukhats single or double pattam, with or without ventilator made of M.S angle of required section M.S flat & tie bar including supply & fixing of 100 mm ISI make M.S but hinges 4 no insingle leaf and 8 No, in double pattam single leaf, and 6 Nos in double leaf single pattam and 12 Nos in double pattam double leafincluding supply of all steel wastage cost of hinges cutting moulding & welding & making locking arrangement for sliding bolts & tower bolts complete ,. Required for proper completion of the work
17Supply of M.S Z- section , windows frame withfixed or openable single side or both side with fully glazed shutters but excluding supply and fixing of glass panes includingas per given drawing as per direction of Engineer - in- charge the section , windows may be fixed or openable or partly fixed & partlyopenable as per direction by the Engineer- in- charge the frame and leaf shall be made of Z- section F4 or F7 T- iron as required including fixing of M.S handle & locking arrangement iron hooks & 150 mm x 12 mm M.S tower bolts top & bottomof shutters ( leaf ) including cost of fitting the shutters may be one side or both side as required including supply of all steel fittings and welding complete work
18Supply and fixing of Fabrication of Mild steel window/Fixed Grill/ Gate includingas per given drawing as per direction of Engineer - in- charge.
19Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete.With 2nd class teak wood beading 62X19 mm
20Fixing of Door, windows / ventilators chaukhats in position.(i) Door chaukhats
21Fixing of Door, windows / ventilators chaukhats in position.(i) Window chaukhats
22Fixing of Door, windows / ventilators chaukhats in position.(i) Ventilator chaukhats
2315mm thick plinth plaster in cement sand coarse ( Fm 1.50-2.20) and mortarin proportion of 1:4 including water proofing materialof ISI marked and approved quality as directed by the manufacturer on walls including supply of all material, labour, T&P etc. Required for proper completion of the work.
2412 mm thick cement plasterinsingle coat on rough sideofsingle orhalfbrick wall for interior plastering up to floor twolevelincludinginternalrounded angles not exceeding80mm ingirth and finshed even and smooth. 1 cement : 4Course sand ( FOR APPRON DRAIN)
2512 mm thick cement plasterinsingle coat on rough sideofsingle orhalfbrick wall for interior plastering up to floor twolevelincludinginternalrounded angles not exceeding80mm ingirth and finshed even and smooth. 1 cement : 6Course sand
26Engraving lines in the plaster of outer face wall vertically and horizontally to display the surface as stone facing as directed by the Engineer-in-charge including labour & T& P etc. required for proper completion of the work. Add for extra labour to all items of plaster.
276 mm cement plaster 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams.
28Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor).
29Supply and fixing 6 to 8 mm thick ivory or light shades Vitrifiedtiles 600x600 mm size in flooring and skirting with 1:4 approved cement and coarse sand morter finished with in its cement colour slurry, jointing and polished of approved quality complete, includng supply of all materials, labour,tools and plants etc. including required for proper completion of the work. as per direction of Engineer-in-charge
30Providing and laying 25 mm Kota Stone flooring over 25mm thick basecement mortar 1:4 ( 1 cement : 4 coarse sand Fm 1.50-2.20 ) laid over jointed with grey slurry mixed with pigment to match the shade of floor including rubbing and polishing complete .
31Kota stone slab 20mm thick in risers of steps, skirting dado and pillars laid on 12mm ( average ) thick cement mortar 1:3 (1 cement : 3 coarse sand) jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete.
32Supply of fixing 6 mm (1/4\") thick china white glazed tile in flooring or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement jointed and polishing complete including supply of all materials, labour for proper completion of the work.
33Providing and fixing 18 mm thick gang saw cut, mirror polished, (premoulded and prepolished), machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab over 0.50 sqm
34Providing and fixing of flush door shutters commercial quality conforming to IS : 2202 Part I (1983) including fixing fixing of wooden cleats & stoppers and including fixing and adjustment of hinges, bolts locks, handles, springs and other fittings but excluding their supply and including painting with two coats of black Japan paint on all iron fitting if necessary. Fitting with necessary screws to be supplied departmentally.(i) 32 mm thick Single Leaf
35Providing and fixing of flush door shutters commercial quality conforming to IS : 2202 Part I (1983) including fixing fixing of wooden cleats & stoppers and including fixing and adjustment of hinges, bolts locks, handles, springs and other fittings but excluding their supply and including painting with two coats of black Japan paint on all iron fitting if necessary. Fitting with necessary screws to be supplied departmentally.(i) 32 mm thickDouble Leaf
36Providing & fixing stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (i) 300mm x 16mm
37P/Fixing stainless steel tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as / IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. (i) 300 mm x 10mm
38Providing & fixing stainless steel handles ISI marked anodised ( anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete. (i) 125 mm
39Distempering (Two coats) with oil bound distemper of approved brand and manufacture and of required shade on undecorated wall surface to give and even shade over and including a priming coat with cement primer of approved brand and manufacture such as Berger, J&N Shalimar, Asian Paints after thoroughly brushing the surface free from mortar dropping and other foreign matter including supply of all material, labour, T&P etc. Required for proper completion of the work. Asian or burger make distemper shall be used.
40Finishing walls with water proofing cement paint of approved make such as Super snowcem, Durocem, Robiance, Guttucem, Supercem quality and of required shade on undecorated wall surface (two coat) over and including one coat white cement primer to give and even shade after thoroughly after brushing the surface to.SI No- 660+661
41Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with : 4.0 mm thick glass panes sqm
42Painting or vanishing two coats on iron works in small areas or new steel work with one coat of ready mixed priming paint & one coat of approved superior quality ready mixed paint of clear synthetic varnish including supply of all materials labour and T & P etc. required for proper completion of work.Paint to be used should confirm to the I.S.I No.103 1950
43Painting or vanishing two coats on iron works in small areas or new wood work with one coat of ready mixed priming paint & one coat of approved superior quality ready mixed paint of clear synthetic varnish including supply of all materials labour and T & P etc. required for proper completion of work.Paint to be used should confirm to the I.S.I No.103 1950
44Providing and fixing glass strips in joints of floors and skirting or dado add the time of laying floors flush with floor level including supply of all materials, labour T & P etc. required for proper completion of the work. 3.15mm thick and 3.70 cm depth
45Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).
46Supply and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge.
47Construction of Septic tank (10 users) of size 1.08 x 0.060 x 1.20 m and Soak pit of size 1.00 mt. dia and 1.50m depth as per given detail drawing including excavation disposal of surplus earth refilling it with coarse aggregate and RCC slab on top 1 :1½ :3 with 600mm dia manhole cover and frame complete as required as per the standard design. And also direction of Engineer-in-charge.
48Supply & Fixing 80 mm thick Precast cement concrete I-Shape interlocking paver block Road with 15 cm thick base concrete 1:4:8 and side brick Wall 1:4 brick workclass -150Interlocking block with top layer of minimum 8 mm thickness having plan dimension 200x(160+120mm) of O.P. cement, Smooth high gloss finish skid reditantmanufactured from rubber moulds through vibro-compression machanism. the compressive strength of concrere paver block shall not be less Than 30MPA ((M-30) AND wight 5kg per no confirming to IS;15658-2006 with a 4 cm thick layer of fine sandincluding cost of material,labour, T& P TAXES etc. requried for proper completion of the work as directed by Enginner-in-charge. (I)Grey color )
49Providing & fixing white vitereous china water closet squatting pan ISI marked (Indian type W.C. pan) with 100mm sand cast iron P or S trap, 10/12.5 litrsPVC low level flushing cistern with fittings & brackets 40mm dia C.P. flush pipe with fitting & clamps, 20mm over flow pipe with specials and mosquito proof coupling of approved municipal design, painting wherever required including cutting & making good the walls & floors where required.(i) Orissa Pattern W.C. pan of size580x 440mwith integral type foot rests flush pipe and over flow arrangement.
50Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid
51Providing and fixing white vitreous china laboratory sink including making all connections excluding cost of fittings cutting & making good the walls wherever required. size 600x450x200 mm
52Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. (i) 32 mm dia
53Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. (i)) 40 mm dia
54Providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with C.P. brass screws and washers.
55Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 17.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
56Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm,including painting of fittings and brackets, cutting and making good the walls wherever required : 17.10.1 Kitchen sink with drain board17.10.1.1 510x1040 mm bowl depth 250 mm
57Providing & fixing PTMT towl rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fitting arrangement of approved quality and colour. 600 mm. long towl rail length of 645 mm. width 78 mm. and effective height of 88 mm, weighing not less than 190 gms.
58Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms
59Providing and Fixing C.P. brass Ablution health faucet assembly with 1.2 m long braided PVC hose with mounting bracket fixed on wall complete.[FOR EWC]
60Providing & fixing UPVC Floor trap of self cleansing designwith CP Jalicomplete in all respects. (Make : Supreme / Finolex / Prince) P-Trap type Floor Trap 110 x 90mm
61Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.110 mm bend
62Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.75 mm bend
63Providing and fixing C.P. brass Two-way angle valve for EWC points & for fixing Ablution Health Fauct of approved quality conforming to15 mm nominal bore
64Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. a) 110 mm diameter
65Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. b) 75 mm diameter
66Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. (a) 110mm
67Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall(i) 25 mm dia nominal bore (medium duty)
68Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall(i) 15 mm dia nominal bore
69Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall(i) 20 mm dia nominal bore
70Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions.(i) 15 mm nominal bore
71Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 (i) 15 mm nominal bore
72Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.(i) 15 mm nominal bore
73Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931(i) 15 mm nominal bore
74Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank. [Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license].Capcity in Per Liters
75Providing and fixing brass stop cock of approved quality.(i) 20 mm nominal bore
76Supply and fixing of UPVC S.W.R. pipe line type - Bof 110mm dia comfirming to IS 13592 includingjointing the pipes with rubber ring and lubricant and UPVC SWR cuplar confirming to IS -14735 alsoincluding excavation of trenches cutting of walls and holes and also repairing the walls, floors and refilling the trenches as before. butsupply and cost of other fittings such as elbow , bend , tee and Y tee including supply and all material labour and T&P . Required for proper completion of hte work.( Ch23 SI No 34 New item )
77Supply and fixing of UPVC S.W.R. Gully trap comfirming to IS-14735 size 150x110mm dia of salf cleaningdesign including fixedbrick Masonry chamber 250x250x250mm .size including supply and fixing of CI coverwith frame CIgrating.150x150mm complete in all respects..
78Wiring point for light with 1.5 Sq. mm FRLSH PVC insulated multistrand single core copper conductor cable in heavy guage PVC conduit pipe partly concealed in the wall and partly laid in slab with 1.5 Sq.mm FRLSH PVC insulated multistrand copper conductor cable as earth wire drawn inside of pipe, moduler type switch in place of piano type switch & ceilling rose/angle/batten holder on 3 mm thick phenolic paminated backalite sheet etc. switches shall be fixied on suitable size MS box shunked in wall with 3 mm thick phenolic paminated backalite sheet and brass screws and washers complete in all respect as directed by E/I including matching colour wash. PWD SOR-2018, SI.No.-138C
79Wiring point for light duty exaut fan with 1.5 Sq. mm FRLSH PVC insulated multistrand single core copper conductor cable in heavy guage PVC conduit pipe partly concealed in the wall and partly laid in slab with 1.5 Sq.mm FRLSH PVC insulated multistrand copper conductor cable as earth wire drawn inside of pipe, moduler type switch in place of piano type switch & ceilling rose/angle/batten holder on 3 mm thick phenolic paminated backalite sheet etc. switches shall be fixied on suitable size MS box shunked in wall with 3 mm thick phenolic paminated backalite sheet and brass screws and washers complete in all respect as directed by E/I including matching colour wash.
80Wiring point for plug with 1.5 Sq. mm FRLSH PVC insulated multistrand single core copper conductor cable in heavy guage PVC conduit pipe partly concealed in the wall and partly laid in slab with 1.5 Sq.mm FRLSH PVC insulated multistrand copper conductor cable as earth wire drawn inside of pipe, moduler type switch in place of piano type switch & ceilling rose/angle/batten holder on 3 mm thick phenolic paminated backalite sheet etc. switches shall be fixied on suitable size MS box shunked in wall with 3 mm thick phenolic paminated backalite sheet and brass screws and washers complete in all respect as directed by E/I including matching colour wash.
81Supply and wiring of submain 2 number 4 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 2.5 sqmm FRLSH PVC insulated multistranded copper conductorcable as earth contunity wire etc. complete in all respects.
82Supply and wiring of submain 2 number 2.50 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick) 25 mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 1.50 sqmm FRLSH PVC insulated multistranded copper conductorcable as earth contunity wire etc. complete in all respects.
83Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects.
84Erection and testing exhaust fan on the exhisting hole with suitable size of rag bolts nuts and washers etc. complete in all respects.
85Supply and fixing of electronic fan regulator( Modular)120-280 V. ISI marked, on the existing switch board including making connections, required material, labourT&P etc. for proper completion of work to the satisfaction of Engineer in charge of work.
86Supply and fixing ofLED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fittingincluding tube on Surface complete in all respect.cat-AA (i) 1x20 Watt.
87Supply & fixing of fbatten/ angle holder with led bulb 9 to 12 Watt complete in all respect.
88supply and erection of AC 1400mm Sweep 230/250 Volts, 50 Hz ceilling with regulater standar down rod, blades including conection etc. complete as required.
89Supply of AC 230/250 volts 50 HZ exhaust fans including providing bolts, mounting frame and cther accessories etc. complete
90Construction of recess distribution board of all sizes including cutting of brick work providing lintel of suitable size & thickness plastering etc. with supply of all materials, labours, T & P etc. required for proper completion of work.(i) 600x480x200 mm. size
91Supply and fixing of factory fabricated M.S. box in existing sunk with Godrej type almirah cover with handle etc. fabricated from 18 SWG M.S. sheet duly painted with red oxide primer followedby two coats of synthetic enamel paint complete with necessary conduit entry and DP/TPN; fixing arrangement and provision for compartment for loose wires, openable housing on the top and hold fast etc. including supply of all material, labour and T & P etc. required for proper completion of the work. (i) 600x480x200 mm. size
92Supply and fixing of flush/surface mounting distribution boards complete in all respects.4 Way TPN CAT - B
93Supplyfixing of 240 volts \" L\"series miniature circuit breaker 9 K.A/. In existing MCB,DB complete with connections as required.32 ampCAT - B
94Supply fixing and making connection of following FPMCBS complete in all respects as per direction and satisfaction of engineer-in-charge.40 Amp. 4 Pole
95Supply and fixing of power plug with 15A/250 V flush type switch and 3 Pin 15 A/250V flush type socket in suitable M.S. box of 175mmx100x50mm size Switch bakellite sheet cover 3mm thick fixed with brass machine screws and cup washer.
96Supply and burying of 600mm x 600 mmx6mm G.I. plate, vertically for earthing with its top atleast 3 mts. below ground level complete with 20mm G.I.pipe and funnel for watering and two earthing leads of No.8to10SWG G.I.wire in 15mm diaG.I. pipe upto switch board (from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm. square C.I. frame with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in
97Supplying & Laying of 25mmx3mm G.I. Strip for earthing purpose as required complete in all respects.
98Supply & fixing of two number 8 SWG G.I. wire for earthing purpose as required complete in all respects.
99Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750 mm below ground level over a cushion of 75 mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. or as directed by the Engineer-Incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. (i) 10 Sq mm 4 core
100India marka -II hand pump ISI marked with cylinder & connecting rods complete
101110mm PVC pipe 6kg/sqcm pressure.
102110mm dia PVC strainer 4mt. Long ribbed with standerd trap & spacials.
103Nylon mesh narial rope arround strainer.
104Supply of medium class G.I. pipe 32mm \"B\" class.
105Providing necessary boring T&P including making arrangement of water for boring 150mm dia bore by plam pressure method in all type of streta complet item.a) 30.00 mt. BGL.
106Providing necessary boring T&P including making arrangement of water for boring 150mm dia bore by plam pressure method in all type of streta complet item.(a) Beyond 30.00 mt.
107Supply of labour T&P and jointing & lowering of PVC pipe consisting of 110mm , 63mm,50mm dia bore long ribbed PVC strainer complete ite.a) 30.00 mt. BGL.
108Supply of labour T&P and jointing & lowering of PVC pipe consisting of 110mm , 63mm,50mm dia bore long ribbed PVC strainer complete ite.b) Beyond 30.00 mt.
109Supply of shournding or packing of grading (0.mmto 0.6mm) coarse sand in bitween the bore well and the strainer PVC pipe from the bottom of the strainer & cavity complete item.
110Installation of india marka II handpump over the bore as per direction of E/I.
111Development of bore by manual labour till discharge is free from turbity complete item.
112Supply & using of PVC cement solvent.
113Supply of all material labour, T&P etc. Required for proper completion of work to construct circular cement concrete (1:2:4) plateform of 1.50 mt. dia for hand pump as per drawing with P.C.C.(1:5:10).
114PUMPING SET KSB make submersible pump set suitable for installation in bore well of min 110 mm inner dia preferably more and having under noted specifications.[1.5 H.P.}

AI Tender Summary

OUR REF NO 34520413
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 25 Lakhs
LAST DATE 08-11-2022
Authority
Authority Name Uttar Pradesh Housing And Development Board
Work Description Constuction Of Health Sub Center And Health Wellness Center At Vill- Gadhi Baroli, Block-Jaitpur Kalan , Distt. Agra
Basic Detail
Tender No 2100/ENG-24/70 DATE 18-10-2022
Bidding Type Tender
Location
City jaitpur
State Uttar Pradesh
Key Dates
Publish Date 31 Oct 2022
Submission Date 08 Nov 2022
Open Date 08 Nov 2022
Finance
Tender Value 25 Lakhs
Tender Fee 1770
EMD 50000
Exemption Not Available
Document List
0f6e95ca-f5f6-4506-8dbc-6df00b567465.html
BOQ_1206492.xls
JAITPURKALAN.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 31, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 08, 2022
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Nov 08, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Nov 08, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

0f6e95ca-f5f6-4506-8dbc-6df00b567465.html

xls

BOQ_1206492.xls

pdf

JAITPURKALAN.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders