Military Engineer Services-MES has published Tender For Provn Of Other Rank Toilet For Office Complex Bldg No P 113 114 Of 19 Ad Regt And Special Repair To Coversion Of Overhead Lt Line To Underground Cable And Connected Items At Qss Offrs Qtr Area At Gms Under Ge I Gos. Submission Date for this Tender is 21-11-2022. Overhead Line Tenders in gopalpur Odisha. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 14-Nov-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 21-11-2022 |
Sl. No. | Item Description |
1 | Surface excavation n.exc 30 cm deep and getting out in soft/loose soil. |
2 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth andgetting out any type of soil all as specified and directed. |
3 | M & L Plain cement concrete (1:4:8) type B-2 using 40mm graded stone aggregate as in foundation filling and mass concrete all as specified. |
4 | M&L for RCC (design mix) M-30 using 20 mm graded stone aggregates as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc, basement slabs, under reamed piles and mass concrete complete all as specified and directed . Note - Reinforcement and form work shall be measured and paid separately. |
5 | M&L for Form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams etc and similar work, vertical or to batter for fair finished flat concrete surfaces complete all as specified and directed. |
6 | M&L for RCC (design mix)M-30 using 20 mm graded stone aggregatesas in columns, pillars, piers, posts and struts and similar work complete all as specified and directed. Note - Reinforcement and form work shall be measured and paid separately. |
7 | Form work to sides of pillars, posts, struts, piers, columns and stanchions for square, rectangular or polygonal fair finished concrete surface complete all as specified and directed |
8 | M&L for RCC(design mix)M-30 using 20 mm graded stone aggregates as in beam, cantilevers, bressummers, lintels over 1.5 m span and similar work complete all as specified and directed. Note - Reinforcement and form work shall be measured and paid separately. |
9 | M &L Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. |
10 | M&L for RCC(design mix) M-30 using 20 mm graded stone aggregates as in chajjas and similar work complete all as specified and directed. Note - Reinforcement and form work shall be measured and paid separately. |
11 | M&L for RCC (design mix) M-30 using 20 mm graded stone aggregates as in slab supported on wall, beam and column in floors, roofs, landings, balconies, canopies and inshelves and similar work complete all as specified and directed. Note - Reinforcement and form work shall be measured and paid separately. |
12 | M&L Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200 mm thick (horizontal or sloping) for fair finished flat surface of concrete complete all as specified and directed |
13 | M&L Form work to edges of concrete flats, treads breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofand sides of bands in walls, horizontal or sloping and similar work for fair finished concrete surface exc 10 cm but not exc 20 cm wide complete all as specified and directed. |
14 | Returning, filling in of soft/loose soil including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed |
15 | Removing surplus excavated earth (soil) to a distance n. exc 50 m & Depositing where directed at a level n. exc 1.5 m above the starting point,including spreading.Complete all as specified and directed. |
16 | S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips |
17 | Ditto, but 5mmdia and over upto and including 10mm dia in stirrups,spacer and binders. |
18 | M & Lbrick work with fly ash bricks, Straight or curved onplan exc 6m mean radius,built in 1:6 in cement mortar all as Specified and Directed |
19 | M & Lbrick work with fly ash bricks, Straight or curved on plan to any radius in half brick thick walls complete built in cement mortar 1:6 all as Specified and Directed |
20 | M & L 40mm thick PCC 1:2:4 damp proof course to horizontal or vertical surfaces including necessary formwork complete all as specified and directed. |
21 | M&L for rendering 15mm thick in CM 1:4 on brick or concrete surface,finishing even and smooth without using extra cement but using waqter proofing compound complete all as specified and directed. |
22 | M&L for rendering 10mm thick in CM 1:6 on brick or concrete surface, finishing even and smooth without using extra cement complete all as specified and directed. |
23 | M&L for rendering 5mm thick in CM 1:3 on concrete surface,as in ceiling finished even and smooth without using extra cement complete all as specified and directed. |
24 | M&L for preparation of new treated surfaces and apply two coats of OBD over a coat of alkali resistant primer to walls complete all as specified and directed. |
25 | M&L for preparation of new treated surfaces and apply two coats of cement based paint over a coat of white wash after preparation of new plastered surface |
26 | M&L applying three coats of white wash complete all as specified and directed. |
27 | M&L moorum / red bajri filling in floors or pavings laid in layers not exceeding 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed. |
28 | M&L Broken stone or boulders hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
29 | M & L Cement concrete type C-2, 1:3:6 using 40 mm graded crushed stone aggreates 100 mm thick as in flooring finished even and fair complete all as specified and directed. |
30 | M&L PCC 1:2:4 type B-1 using 20 mm graded stone aggregate average thickness 25 mm thick as in floors finishes as levelling courese complete all as specified and directed. |
31 | M&L for non skid ceramic coloured tiles of design as approved by GE 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed. |
32 | M&Lfor glazed ceramic coloured tiles 350 x 250 x 7 mm / 450 x 350 x 7 mm thick on vertical surface such as dado / skirting / risers to steps etc jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including rendering 10 mm thick in cement mortor 1:4 complete all as specified and directed. Note- (i) The size of tiles (except thickness) may be varied during execution without any price adjustment. |
33 | M&L 75 mm thickPCC 1:3:6, type C-1 using 20 mm graded stone aggregateas in plinth protection,surfaces finished even and smooth with out using extra cement all as specified. |
34 | M&L for rendering 15 mm thick surface as in roof with integral water proofing compound 3% by the weight of cement in cement mortar 1:4 complete all as specified & directed. (Integral WPC will be measured and paid separately). |
35 | M&L for water proofing treatment to roof surface complete all as specified & directed with the followings :- (a)Apply bituminous based primer confirming to IS: 3384-1965 @ 0.30 kg/sqm.(b)APP modified bituminous membrane 3mm thick with non woven polyester core of weight not less than 3.2 to 3.5 Kg/sqm laid and bonded to the sub strata by heat process, over laps of 100mm shall be sealed/fused by flame torch application as per manufacturer instructions. (c)Applying bituminous based aluminiumpaint @ 0.20 Kgs/Sqm in two coats over APP membrane |
36 | Supply only integral water proofing compound all as specified and directed. |
37 | Providing and fixing factory made uPVC white colour casement (Openable) Door made of extruded profiles with wall thickness of 2.3 mm (+-0.2 mm) window profile with hollow section with multi chamber . Frame (60 mm × 58 mm)sash (60 mm × 78 mm). T- Profile (one vertical length in two shutters)(60mm x 74mm)Glazing bead (35 mm × 20 mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM gasket, 1.2 +- 0.2 mm thick galvanized steel Frame (28 mm × 21.5 mm) sash (31mmx27mm) T- Profile(27mm x 17mm) to be insertedin required profile, frame will be fixed to the wall with 8 mm × 100 mm long fasteners. HARDWARE: (Casement door handle made of zinc alloyed (white coloured coated),corner striker,secondary striker,cylinder,Door transmission gear made of mild steel with multi point locking system with strikes,3D Hinges of Zinc alloyed(white coated powder). ] (Note: The unit rate quoted by contractor include cost of glass/ACP Sheet and includes all other connected accessories. Net opening will be measured for payment purpose) |
38 | S&F factory made UPVC white colour with fixed window/ ventilator made of extruded profile with wall thickness of 2.3mm (+-2mm).Window profile with hollow section with multi chamber.Frame (60mm X58mm).T profile (one vertical length in between two shutters) (60mm X 74mm).Glazed bead (35mm X 20mm) will be mitered cut and fusion selded at all corners including drilling of holes for fixing hardware and drainage of water etc, making arrangement for fixing of hardware, EPDM gasket 1.2 +-0.2mm thick glavanised steel frame (28mm X 21.5mm), T profile (27mmX 17mm) to be inserted in repair profile.Frame will be fixed to the wall with 8mm X 100mm long fasteners.5.5 mm thick glazing with selected quality glass area n.exc 1.00sqm each. |
39 | S&F inrepairsVitreouschinawashdownwaterclosed pan ( Pedestal) white(exc flushing cistern & Pipe ) incl connection to trap and flushing pipe all as specified and directed |
40 | S&F 100 mm bore Cast Iron ‘P’ or ‘S’ trap all as directed. |
41 | S&F 100mm cast iron sanitary connection socket to fit WC out-let |
42 | S&F inPVC low level flushing cistern (white) 10 Ltrs capacity with internal fitting, push button operated type with and including bracket, PVC flush pipe etc complete. |
43 | S&F 75mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement |
44 | S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement |
45 | M&L for PVC (SWR) pipessingle socketed, in any length with rubber ring joints, fixed to walls of 110 mm bore of pipe etc complete all as specified and directed. |
46 | S&F PVC (SWR) bends any radius of 110 mm borewithaccess door complete all as specified and directed. |
47 | S&F PVC (SWR) vent cowl 110 mm bore complete all as specified and directed. |
48 | S&F Bevelled edge mirror of size 600x450mm of selected quality glass 4mm thick mounted on 6mm thick AC building board or commercial ply wood and fixed with wooden plugs with chromium plated screws including taking down existing mirror . |
49 | S&F vitreous china wash basin, white flat back 580mmx450mm, excludings taps, waste, chain and plug and porcelain stopper but including brackets in repairs, all as specified and directed. |
50 | S&F PVC connection 15 mm sizewithPTMT nuts of length 450 mm complete all as specified and directed. |
51 | S/F health faucet with fluxi pipe and hand shover ,the length of hose 1.50mt fitted to the tap complete all as specified and directed. |
52 | S&F PTMT waste coupling of 32mm dia for wash basinall as specified and directed. |
53 | S&F 15 mmfancy type pillar taps chromium plated cast copper alloy with capstan heads screwed down high pressure with or without lettered ‘Hot’ or ‘cold’ with long screwed shanks and fly nuts all as specified and directed by Engr-in-charge. |
54 | S&F 25mm dia GI tubing medium grade -ditto- |
55 | S&F 20mm dia GI tubing medium grade -ditto- |
56 | S&F 15mm dia GI tubing medium grade -ditto- |
57 | S&F rotational, moulded polyethylene water storage tanks,1000litres capacity (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I |
58 | S&F 25mm dia ball Brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipes or brass ferrule and fixed as in PVC Service tanks all as directed. |
59 | S&F 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed to 20mm dia GI tube. |
60 | S&F 15 mm fancy type angle cock cast copper alloy with long shank and cup(concealed type) any type scrwed down high pressure with crutch and butter fly handle screwed both ends for iron or union and fixed to 15 mm GI tube complete all as specified and directed by Engineer-in-Charge. |
61 | S&F 15mm borebib tap cast copper alloy chromium plated with crutch or butterfly handle fixed to 15 mm dia GI tube all as specified and directed. |
62 | S&F soap dish any type fixed to plugs with chromium plated brass screws complete all as specified and directed |
63 | Excavation in trenches n.exc 1.5m deep & n.exc1.5m wide on plan in ordinary soft/loose soil and getting out. |
64 | M&L for 150 mm bore salt glazed stoneware drain pipe grade ‘A’ laid in trenches complete all as specified and directed. |
65 | M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in concrete bed to drain pipe including packing under, and hunching against the sides of pipes after they are laid and tested for 200mm dia pipe complete all as specified and directed. |
66 | Returning, filling in of soft/loose soil including spreading, levelling, watering and well ramming in layers not exc 25 cm. |
67 | Removing surplus excavated earth (soil) to a distance n. exc 50 m & Depositing where directed at a level n. exc 1.5 m above the starting point. |
68 | Cutting in to existing manholes for connecting new drains, making good to pipe & rendering cutting out existing benching for and forming branch channel in cement concrete1:2:4 type B-1 smooth finished and reforming benching as required for 200 mm bore drain pipe. |
69 | M&L for point wiring with 1.5 Sqmm signle core PVC insulated unsheathed copper FRLS multi stranded conductor cable in and including concealed PVC conduit of size 20/25 MM ISI marked inclusive of tees, bend, elbows etc upto and including sunk in anodized pressed steel box for housing switch socket etc with white laminted 3mm thick sheet cover ISI marked of suitable size complete including PVC insulated multi stranded copper conductor 1.5 Sqmm FRLS cable as earth wire to common earth dolly for connection to ceiling rose to earth terminal incuding cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed by ENgr-in-Charge for One light point controlled by one , one way switch 5 Amp. |
70 | (b) One exhast fan point controlled by one , one way switch 5 amp |
71 | (c) One 3 pin socket outlet 5 amps on the same board |
72 | M&L Switchpiano flush button single pole one way 6 Amps, complete all as specified and directed. |
73 | M&L for Ceiling rose 3 terminals of PVC/ polycarbonate, as per relevant IS code, ISI marked isolated body complete all as specified and directed. |
74 | S&F LED tube light fitting 4ft, 20 watts, 220 volts, 50 Hz complete all as specified and directed |
75 | S&F Sheet metal enclouser for DB"s when MCBs to be used single pole neutral 4 way with 200 Amp rated bus bar double door complete all as specified and directed. |
76 | Supply and fixing amp rating 240V, 10KA "C" curve miniature circuit breaker (MCB) of 32 Amps SPN and current carrying capacity in the MCB DB complete with connection testing and commissioning. |
77 | Supply and fixing 240V, 10 KA "B" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning. |
78 | Earthing complete with galvanisedsteel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion |
79 | M&L for GI tube medium grade of size 32 MM dia laid for protection of cable/ earth strip complete all as specified an directed |
80 | M&L for service cable of size 6 Sqmm 2 core aluminium conductor , 240 volts, 50 Hz complete all as specified and directed |
81 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm complete all as specified and directed |
82 | Galvanised iron water tubing (ISI marked) 25 mm bore(light grade) with and including all fittings (ISI marked ) such as sockets,bends, elbows, unions, tees, diminishingpieces etclaid in trenches/under road/along pole or fixed to walls, complete all as specified and directed by Engr-in-Charge. |
83 | Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 metre in depth and getting out soft/loose soil, complete all as specified and directed by Engineer-in-Charge. |
84 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick, complete all as specified and directed by Engr-in-Charge. |
85 | Removing surplus soil to a distance n.exc 50m and deposited where directed at a level not exceeding 1.50 m above the starting point, complete, all as specified and directed by Engr-in-Charge. |
86 | Supply and laying for 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches of size 25 mm complete |
87 | Supply and fixing PP-R Gate valves (brass insert) of size 25 mm dia complete as per requirement of the site |
88 | Making connection of PP-R distribution branch with PP-R main of following sizes by providing and fixing tee including cutting and making fusion joint etc |
89 | Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 metre in depth and getting out soft/loose soil, complete all as specified and directed by Engineer-in-Charge. |
90 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick, complete all as specified and directed by Engr-in-Charge. |
91 | Supply dry sand for cushioning to underground cables 8cm thick before laying cable and 15cm thick after lying and streching the cable, complete all as specified and directed by Engr-in-Charge. Note :- For payment purpose punned thickness shall be measured. |
92 | Removing surplus soil to a distance n.exc 50m and deposited where directed at a level not exceeding 1.50 m above the starting point, complete, all as specified and directed by Engr-in-Charge. |
93 | Sub class ‘B brick, old size, as cable protection cover, laid dry, flat, transversally along the length of cable, on sand cushioning, with width equal to the length of the brick, complete all as specified and directed by Engr-in-Charge. |
94 | M&L for laying of steel water tube medium grade under road/ path of bore 80 mm complete all as specified and directed by Enhr-in-Charge |
95 | M&L for laying in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sqmm 4 Core complete |
96 | M&L for laying in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 Sqmm 3.5 Core complete |
97 | M&L for laying in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 150 Sqmm 3.5 Core complete |
98 | M&L for laying in replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 185 Sqmm 3.5 Core complete |
99 | Earthingcompletewith galvanisedsteelearthplateelectrode 600x600x6mm burrieddirectlyin groundnotless than 2.25mtr deepbelow normal ground level with top edgeof earth plate not less than 1.5mtrbelow normal ground level connected to the Galvanised iron strip 32x6mm sizeby meansof bolts ,nuts,check nutsandwashersof galvanisediron and 32x6mm GI strip procted by provision of GI light grade pipe 40 mm boreincl provision of concrete pit in PCC1:2:4 typeB-1, using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPMweight not less than 4 Kg /Sqm and 6mm diabar handle ,excavationand earthworkin any type of soil ,charcoaldustand saltlightgrade GI watering pipe 20 mm bore with funnel complete all as shown in electrical plateNo 3 of MES Sch 2009 Part-I all as specifiedand directed. Notes:- (i)Main earthing strip from earth plate electrode to test point upto length of 7.5 metres length shalldeem to be included in the unit rate quoted against this item. (ii) GI protection pipe & earthing lead beyond 7.5 metres shall be measured and paid for seperately under appropriate item of Sch A part-I. (iii) On testing after completion ifdesired resistanace is not obtained, the contrator shall redo the earthing without any extra cost to the department. |
100 | Supply, installation, testing and commissiioning of CPRI approved LT panel board, outdoor type, with front and back door openable type fitted with nuts, bolt and washers fitted with knob and hinges, floor mounted fabricated out of 3.00mm thick MS sheet to be placed over pedestals in PCC 1:3:6 type C-1 cement concrete extending 300mm above ground level with one meter wide plaform in all round panel LT panel shall be totally enclosed weather proof and verming proof with front and rear opening with IP-54 protection as per IS-8623 duly powder coated for connection, RYB, insulator complete pre-wired and cable connection with copper conductor wire upto alkuminium bus bar including all incoming and outgoing cable connection with suitable size of aluminium lugs/gland complete all as specified and directed by Engr-in Charge and also comprising of the following. (i)MCCB FP, 50 KA, 400 A, Adjustable thermal & Fixed magnetic setting. 1 Nos. Incoming (ii) MCCB FP, 25 KA, 100A, Adjustable thermal & Fixed magnetic setting. 6 Nos. Outgoing (iii)Aluminiumbus bars sleeve insulated of size 40 x10mm TPN mounted on epoxy insulators-01 Set (v) LED KWH meter, 3 Phase, 0-60 A with CTs- 01 No (vi) Digital voltmeter 0 - 500 V range with selector switch - 01 No (vii)Digital ammeter 0 - 500 A range with selector switch and CTs - 01 No (viii)Indicators RYB - 01 Set (ix)Internal wiring of the panel board with single core copper cable PVC insulated of suitable size and control fuses. |
101 | Supply and fixing cable jointing kit for 1.1 KV (Earthed)grade cable for heat shrinkable straight end termination kit outdoor type complete with jointing material and accessories suitable for XLPE, LT cable, 1100 volts grade of size 6 to 16 Sqmm 4 corecomplete all as specified and directed by Engr-in-Charge. Make - 3M or equivalent |
102 | Supply and fixing cable jointing kit for 1.1 KV (Earthed)grade cable for heat shrinkable straight end termination kit outdoor type complete with jointing material and accessories suitable for XLPE, LT cable, 1100 volts grade of size 25 to 50 Sqmm 4 corecomplete all as specified and directed by Engr-in-Charge. Make - 3M or equivalent |
103 | Supply and fixing cable jointing kit for 1.1 KV (Earthed)grade cable for heat shrinkable straight end termination kit outdoor type complete with jointing material and accessories suitable for XLPE, LT cable, 1100 volts grade of size 70 to 120 Sqmm 4 corecomplete all as specified and directed by Engr-in-Charge. Make - 3M or equivalent |
104 | Boring of holes horizontally for laying of 80mmdia pipe (minimum depth 0.60 Mtr from top level) under road, Pavement, hard standing complete all as specified and directed. |
105 | Supply and fixing in repairs LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. |
106 | Supply and Fix in repair for PVC junction box of size 270 x 225 x 135 mm with Aluminium bus bar 200 Amps capacity -4 No"s. MCB SP 6 Amp - 1 No and having provision of cable hole in bottom for two to three armoured cables of size 25 Sqmm 3.5 core, connection box shall be fitted on street light pole and fixing arrrangements i.e. MS clamps etc deemed to be provided by the contractor all as specified and directed . Make Syntex/Hensel |
107 | Taking down and replacement ofexisting unserviceable street light fitting bracket with new brackets made out of 32mm bore GI pipe, light grade, tubing bend to shape, 1.2 metre long, fixed to pole/wall, painting with two coats of aluminium paint over a coat of red oxide primercomplete, all as specified and directed. |
108 | Taking down and replacement ofexisting unserviceable clamps with new clamps made out of 40x3 mm bending to shape, drilling holes for bolts suitable for fixing GI pipe bracket to steel pole, made in two halves, including nuts, bolts, washers and painting with two coats of aluminium paint over a coat of red oxide primer,complete, all as specified and directed. |
109 | M&L for painting steel tubularpole 9 mtrs long alongwith bends with two coats of aluminium paint over a coat of red oxide primer, 1.2 mtr height from top of copping with two coats of black bituminius paint/ yellow paint with equal height of 0.3 mtr each alternately and including marking of pole number with black paint in yellow circle, complete, all as specified and directed. |
110 | M&L for painting PCCpole 9 mtrs long alongwith bends with two coats of weather proof paint and 1.2 mtr height from top of cooping with two coats of black bituminous paint/yellow paint with equal height of .3 mtr each alternately and including marking of pole number with black paint in yellow circle, complete, all as specified and directed. |
111 | M&L in repairs for PVC electric conduit pipe of size 20 MM dia complete all as specified and directed to be connected from junction boxes to steet light bends complete. |
112 | S&F in repairs for pvc insulated flexible copper cable of size 1.0 Sqmm 3 core FRLS complete all as specified and directed |
113 | M&L for taking down old unsv ACSR conductors complete all as specified and directed by Eng-in-Charge |
114 | M&L for taking down old unsv cross arms/channels, insulators, brackets and other connected items complete all as specfied and directed |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy