Tender For Ge(U)/Chm-27/2022-23 Repair / Maintenance Of Certain Items Of Cold Storage Walk In Cooler And Domestic Summer Appliances (Water Storage Coolers Acs And Refrigerator) At Command Hospital (Wc) Chandimandir, chandimandir-Haryana

Military Engineer Services-MES has published Tender For Ge(U)/Chm-27/2022-23 Repair / Maintenance Of Certain Items Of Cold Storage Walk In Cooler And Domestic Summer Appliances (Water Storage Coolers Acs And Refrigerator) At Command Hospital (Wc) Chandimandir. Submission Date for this Tender is 18-11-2022. Air Conditioner Tenders in chandimandir Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

34499610
Corrigendum : Tender For Ge(U)/Chm-27/2022-23 Repair / Maintenance Of Certain Items Of Cold Storage Walk In Cooler And Domestic Summer Appliances (Water Storage Coolers Acs And Refrigerator) At Command Hospital (Wc) Chandimandir
Open Tender
Indian
Haryana
chandimandir
18-11-2022

Tender Details

Repair / Maintenance Of Certain Items Of Cold Storage Walk In Cooler And Domestic Summer Appliances ( Water Storage Coolers Acs And Refrigerator ) At Command Hospital ( Wc ) Chandimandir

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 11-Nov-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 18-11-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 39960.0 /-
Tender Value
INR 19.98 Lakhs /-

BOQ Items

Name of Work: REPAIR / MAINTENANCE OF CERTAIN ITEMS OF COLD STORAGE, WALK IN COOLER AND DOMESTIC SUMMER APPLIANCES (WATER STORAGE COOLERS, ACs AND REFRIGERATORS) AT COMMAND HOSPITAL (WC) CHANDIMANDIR
Sl. No. Item Description
1Taking outcarefully outdoor unit after disconnecting all incoming and outgoing electric, drain&copper pipe connectionof 3 phase,3 TR AC anddismantling completeoutdoor unit andkeepingparts like Compressor 3 phase, Condensing unit, fan motor 3 phase,blade, single phase preventer, overload relay,LP & HP Switch etc.in safe custody forreuse (Serviceable parts ) at siteafter cleaning and servicing reassemblingcompleteand fixing on same position and testing for entire satisfaction ofEngr-in-Charge. Note: New spare parts such as Compressor 3 phase, Condensing unit, fan motor 3 phase, blade assembly,single phase preventer, overload relay, LP & HP Switch, Refrigerant, drain pipe, Copper pipe, electric cable and charging of gas etc., as required will be measured and paid under appropriate items
2Taking outcarefully indoor unit after disconnecting all incoming and outgoing electric,drain&copper pipe connectionof3 phase,3 TR AC anddismantling completeindoor unit andkeepingparts likeindoor fan motor , fan motorblade,single phase sensor, PCB display,sub-zero displayetc.in safe custodyforreuse (Serviceable parts ) at siteafter cleaning and servicing reassemblingcompleteand fix on same position and testing for entire satisfaction ofEngr-in-Charge. Note: New spare parts such asindoor fan motor, fan motorblade,single phase sensor, PCB display,sub-zero display , refrigerant , drain pipe, Copper pipe, electric cable and charging of gas etc., as requiredwill be measured and paid under appropriate items.
3Supply only outdoor unit body cover, made out of mild steel duly powder coated,suitable for outdoor unit of capacity3TR, 3 Phase AC all as directed by Engr-in-Charge.
4Supply only indoor unitbody cover, made out ofstainless steel,suitable for 3TR, 3 Phase cold storage type,air conditioners all as directed by Engr-in-Charge.
5Supply only3 TR compressor for AC, 3 Phase, 415 volts all as directed by Engr-in-Charge.
6Supply only outdoor unit blowermotor, electric driven,suitable for3TR,3 Phase, 415 volts, cold storage type AC all as directed by Engr-in-Charge.
7Supply only Single phase Preventer, suitable for 3TR capacity, 3 Phase, 415 volts, cold storage type AC all as directed by Engr-in-Charge.
8Supply onlycontactorof capacity, 32 amps, 3 phase, 415 volts, suitablefor3 TRcapacitycold storage typeAC all as directed by Engr-in-Charge.
9Supply only LP & HP Switch, single phase, suitable for3 TRcapacityAC all as directed by Engr-in-Charge.
10Supply only over load relaysuitable for3 TRcapacity,3 Phase, 415 voltscold storage type AC all as directed by Engr-in-Charge.
11Supply only condensing coil in outdoor unit of 3 TR, 3 Phase capacity cold storage type AC all as directed by Engr-in-Charge.
12Supply only wiring box in outdoor unit of 3 TR, 3 Phase capacity cold storage type AC all as directed by Engr-in-Charge.
13Supply only indoor unit blowermotor, electric driven,suitable for3TR capacity ,3 Phase, 415 volts, cold storage type AC all as directed by Engr-in-Charge.
14Supply only indoor unit temperature control sensorsuitable for 3TR capacity, 3 Phase, 415 volts, cold storage type AC all as directed by Engr-in-Charge.
15Supply only indoor unit PCB display board suitable for3TR capacity ,3 Phase, 415 volts, cold storage type AC all as directed by Engr-in-Charge.
16Supply only indoor unitSub Zero displaysuitable for3TR capacity ,3 Phase, 415 volts, cold storage type AC all as directed by Engr-in-Charge.
17Supply only indoor unitcooling coilsuitable for3TR capacity ,3 Phase, 415 volts, cold storage type AC all as directed by Engr-in-Charge.
18Supply only indoor unit expansion valve suitable for 3TR capacity, 3 Phase, 415 volts, cold storage type AC all as directed by Engr-in-Charge.
19Taking out defective / burnt outcompressor unitafter disconnecting all incoming and outgoing electric connection, nut/bolts etc. from theoutdoor unit of5 TRcapacity AC and supplying & installing newcompressor unitof same capacity i.e. 3 Phase, 415 volts , suitable for5 Toncapacity out door unitand testing complete all as directed by Engr-in-Charge.
20Taking out defective / burnt outmotor after disconnecting all incoming and outgoing electric connection, nut/bolts etc. from theoutdoor unit ofAC8.5 TRcapacityand supplying & installing new electric motor of same capacity i.e. 3 Phase, 415 volts , suitable for8.5 Toncapacity out door unitand testing complete all as directed by Engr-in-Charge.
21Taking out defective / burnt outmotor after disconnecting all incoming and outgoing electric connection, nut/bolts etc. from theoutdoor unit ofAC5/ 5.5 TRcapacityand supplying & installing new electric motor of same capacity i.e. 3 Phase, 415 volts , suitable for5/ 5.5 Toncapacity out door unitand testing complete all as directed by Engr-in-Charge.
22Taking out defective PCB unit from the 3 phase, 3 to 8.5 TR capacities AC and carrying to service center for repairing and refixing in position in same place and testing after necessary repairs complete all as directed by Engr-in-Charge.
23Taking out defective PCB unit from the 1.5/ 2 TR capacities AC and carrying to service center for repairing and refixing in position in same place and testing after necessary repairs complete all as directed by Engr-in-Charge.
24S & F as in repairs PCB units suitable for inverter type AC of capacity 1.5/2 TR complete and testing complete all as directed by Engr-in-Charge.
25Taking out defective / burnt outblowermotor after disconnecting all incoming and outgoing electric connection, nut/bolts etc. from theindoorunit of5/ 5.5 TRcapacity of AC andsupplying &installing new electric blowermotor of same capacity,and testing complete all as directed by Engr-in-Charge.
26Supplyingand fixing outdoor unit of AC of capacity, 2 Ton, Single phase, 230 Voltsall weather type complete including taking out old one &all incoming and outgoing connection and all necessary fixing arrangements & testing complete all as directed by Engr-in-Charge.
27Supplyingand fixing indoor unit of AC of capacity, 2 Ton, Single phase, 230 Voltsall weather type complete including taking out old one &all incoming and outgoing connection and all necessary fixing arrangements & testing complete all as directed by Engr-in-Charge.
28Repairing, servicing and maintenance of water cooler of capacity 40 to 120 litres and replacing defective parts such as compressor, fan motor, thermostate, self-closing 15mm taps, fan blade etc complete all as directed by Engr-in-Charge. Note:compressor, fan motor, thermostat, self-closing 15mm taps, fan blade and charging of gas etc., as required will be measured and paid separately under appropriate items.
29Supply only Compressor unit , AC, Single phase, 230 volts, copper wounded suitable for 40- 120 Litres capacity Water cooler complete all as directed by Engr-in-Charge.
30Supply only Fan motor, Single phase, 230volts complete all as directed by Engr-in-Charge.
31Supply only Thermostat, AC single phase, 230 volts complete all as directed by Engr-in-Charge.
32Supply only Self-closing taps, 15mm bore brass chromium plated complete all as directed by Engr-in-Charge.
33Supply only Fan Blade steel as per existing size complete all as directed by Engr-in-Charge.
34Repairing, servicing and maintenanceof desert cooler of any capacity and replacing defective parts such as fan blade, motor, water pump, honeycomb pad etc complete all as directed by Engr-in-Charge. Note: Fan blade, motor, water pump, honeycomb pad will be measured and paid separately under appropriate items.
35Supply only Fan Blade of desert cooler complete all as directed by Engr-in-Charge.
36Supply only desert cooler fan motor complete all as directed by Engr-in-Charge.
37Supply only Water pump from the desert coolercomplete all as directed by Engr-in-Charge.
38Supply only Honeycomb pad set of three complete all as directed by Engr-in-Charge.
39Repairing, servicing and maintenanceof refrigerator of capacity 175 to 310 Litres and replacing defective parts such as compressor, fan motor, thermostat etc. complete all as directed by Engr-in-Charge. Note:Spare parts will be measured and paid separately under appropriate items.
40Supply only compressor for double door refrigerator complete all as directed by Engr-in-Charge.
41Supply only compressor for single door refrigerator complete all as directed by Engr-in-Charge.
42Supply only Relay OLP for refrigerator complete all as directed by Engr-in-Charge.
43Supply only Thermostat for refrigerator complete all as directed by Engr-in-Charge.
44Supply only Condensing Unit of refrigerator complete all as directed by Engr-in-Charge.
45Supply only Freezer unit of refrigerator complete all as directed by Engr-in-Charge.
46Supply only Condenser coil of refrigerator complete all as directed by Engr-in-Charge.
47Supply only Timer including Biometric Sensor 4 Pin for refrigerator complete all as directed by Engr-in-Charge.
48Supply only Fan motor for refrigerator complete all as directed by Engr-in-Charge.
49Repairing, servicing and maintenance of deep freezer of capacity 200 to 400 litres and replacing defective parts such as compressor, fan motor and motor, charging of Gas and testing complete all as directed by Engr-in-Charge. Note:Compressor, motor fan, motor and charging of gas etc., as required will be measured and paid separately under appropriate items.
50Supply only compressor unitsuitable for 200-400 Litres capacity deep freezer, single phase, 230 volts complete all as directed by Engr-in-Charge.
51Supply onlyfan blade for deep freezer complete all as directed by Engr-in-Charge.
52Supply onlyfan motor for deep freezer complete all as directed by Engr-in-Charge.
53Material and labour for charging the Gas R-134a after testing the system, complete all as directed by Engr-in-Charge.
54Material and labour for chargingthe Gas R-22 after testing the system complete all as directed by Engr-in-Charge.
55Material and labour for chargingthe Gas R-32 after testing the system complete all as directed by Engr-in-Charge.
56Material and labour for chargingthe Gas R-410 after testing the system complete all as directed by Engr-in-Charge.
57Supplying and fixing as in repairs Capacitor 10 Mfd complete all as directed by Engr-in-Charge.
58Supplying and fixing as in repairs Capacitor 06 Mfd complete all as directed by Engr-in-Charge.
59Supplying and fixing as in repairs Capacitor 80/120 Mfd complete all as directed by Engr-in-Charge.
60Supplying and fixing as in repairs Capacitor 04 Mfd complete all as directed by Engr-in-Charge.
61Supplying, fixing and testing as in repairs copper pipe 7/8" heavy duty complete all as directed by Engr-in-Charge.
62Supplying, fixing and testing as in repairs copper pipe 5/8" heavy duty complete all as directed by Engr-in-Charge.
63Taking out defective air curtain from the different locations after disconnecting all incoming and outgoing electric connection and repairing, servicing andmaintenance of the same and installing on same position after reassembling and testing complete all as directed by Engr-in-Charge. Note: fan blade, motor, capacitor, blower assembly, outer body etc.Will be measured and paid separately under appropriate items.
64Supply only outer body of mild steel powder coated for 48" air curtain unit complete all as directed by Engr-in-Charge.
65Supply only blower motor assembly with fan blade and having copper winding suitable for 48" air curtain unit complete all as directed by Engr-in-Charge.
66Supply only air curtain blower motor, double shaft, AC, 230 volts, singlephase having copper winding complete all as directed by Engr-in-Charge.
67Supply only air curtain fan blade ofblower motor complete all as directed by Engr-in-Charge.
Disclaimer :