}

Tender For Purchase Of Instruments Equipments, North Goa-Goa

Directorate of Food and Drugs Administration has published Tender For Purchase Of Instruments Equipments. Submission Date for this Tender is 10-11-2022. Coats and Jackets Tenders in North Goa Goa. Bidders can get complete Tender details and download the document.




Tender Notice

34498853
Corrigendum : Tender For Purchase Of Instruments Equipments
Open Tender
Indian
Goa
North Goa
10-11-2022

Tender Details

Purchase Of Instruments Equipments-Plc Control Based Flameproof Laboratory Refrigerator Control System Ce, Iso And Gmp Approved Flame Proof Temperature Controller With Auto Tune Plc Based Control System. Individual Control System Easy To Install On Suitable Space Software Provision For Future Requirement Machine Should Have A Provision Of Cfr 21 Part 11 Compliance Windows Based Communication Software For Data Management. Complete With Rs-485 Multi Dropping To Monitor Multiple Chambers To One Software In Future ( If Required ) Future Data Logger Provision For Master Controller Data Storage Unit In Future ( If Required ) Air Circulation Motor And Blower Arrangement To Have Uniformity Of Under Loaded Condition. Alarm :Temperature Deviation Alarm Trays: Stainless Steel Trays With Adjustable Height Florescent Light: Cool White Florescent Light Auto On When Door Open Insulation :75” Thick Cfc Free Puf Insulation. Door: Inside See Through Unbreakable Acrylic Door Sub Door: Sub Doors Made Of Acrylic / Glass Door Refrigeration System Hermetically Sealed Cfc Free Emerson Compressor With R 134A Refrigerant Having State Of Art By Pass System For Continues Run Of Compressor. Power:Works On 230 V Ac Single Phase 50Hz Other Castor Wheels, Mcb, Adjustable Tray Height Arrangements. Heavy Duty Latch With Lock & Key Safety Features :180 Sec. Compressor ‘On’ Delay Timer To Safe Guard The Compressor. Documentations Should Provide Iq, Oq, Pq Documents With Material Test Certificates And Calibration Reportsspecifications Temperature Range 2 To 8°C Temperature Accuracy ± 0.5° C Temperature Uniformity 2° C Alarm Audio-Visual Alarm Gmp Models: Inner Stainless Steel 316, 0.8 Mm Mat Finish & Outer Stainless Steel 304 Capacity In Ltr.: 420 Internal & In Cms ( W X D X H ) : 70X50x120 Outer Size In Cms ( W X D Xh ) : 85X75x170 No. Of Trays: 4 Note:- 1. Free Of Cost Installation. Demo And Training To Be Provided On Site. 2. Minimum Period Of Three Year Warranty From The Date Of Installation And Five Years Comprehensive Amc After Expiry Of Warranty Period. 3. All Other Spares , Consumables And Accessories Required For Operation Should Be Made Available For At Least Ten Years. 4. 4. Nomenclatures / Units Should Be Followed As Per Our Specification Or Explained In Compliance Chart. Specifications Temperature Range 2 To 8°C Temperature Accuracy ± 0.5° C Temperature Uniformity 2° C Alarm Audio-Visual Alarm Gmp Models: Inner Stainless Steel 316, 0.8 Mm Mat Finish & Outer Stainless Steel 304 Capacity In Ltr.: 420 Internal & In Cms ( W X D X H ) : 70X50x120 Outer Size In Cms ( W X D Xh ) : 85X75x170 No. Of Trays: 4 Note:- 1. Free Of Cost Installation. Demo And Training To Be Provided On Site. 2. Minimum Period Of Three Year Warranty From The Date Of Installation And Five Years Comprehensive Amc After Expiry Of Warranty Period. 3. All Other Spares , Consumables And Accessories Required For Operation Should Be Made Available For At Least Ten Years. 4. Nomenclatures / Units Should Be Followed As Per Our Specification Or Explained In Compliance Chart. Plc Control Based Flameproof Deep Freezer Control System Ce, Iso And Gmp Approved Flame Proof Temperature Controller With Auto Tune Plc Based Control System. Individual Control System Easy To Install On Suitable Space Software Provision For Future Requirement Machine Should Have A Provision Of Cfr 21 Part 11 Compliance Windows Based Communication Software For Data Management. Complete With Rs-485 Multi Dropping To Monitor Multiple Chambers To One Software In Future ( If Required ) Future Data Logger Provision Master Controller Data Storage Unit In Future ( If Required ) Display Lcd Display Sensors Pt 100 Sensor Alarm 1. Temperature Deviation Alarm 2. Audio Alarm For High And Low Temperature Trays Stainless Steel Trays With Adjustable Height Insulation Polyurethane Insulation 75Mm Thick Cfc Free Puf Insulation. Refrigeration System Flame Proof Hermetically Sealed Cfc Free Emerson Compressor With R 134A Refrigerant Having State Of Art By Pass System For Continues Run Of Compressor. Specifications Temperature Range -30°C Or Less Temperature Accuracy ± 1° C Temperature Uniformity 5° C Resolution 0.1° Alarm Audio-Visual Alarm Gmp Models: Inner Stainless Steel 316, 0.8 Mm Mat Finish & Stainless Steel, 304, 1.0 Mm Capacity In Ltr. :189 Internal Size ( W X D X H ) Cms: 35X45x120 Outer Size ( W X D X H ) Cms : 50X60x170 No. Of Doors : 1 No. Of Trays :4 Note:- 1. Free Of Cost Installation. Demo And Training To Be Provided On Site. 2. Minimum Period Of Three Year Warranty From The Date Of Installation And Five Years Comprehensive Amc After Expiry Of Warranty Period. 3. All Other Spares , Consumables And Accessories Required For Operation Should Be Made Available For At Least Ten Years. 4. Nomenclatures / Units Should Be Followed As Per Our Specification Or Explained In Compliance Chart. Weighing Capacity : Up To 220Gms Readability: 0.1Mg, Repeatability 1 Mg Or Less Linearity: + / - 0.2Mg Reproducibility: < / = 0.1Mg Std Deviation : <+0.1Mg Pan : 80Mm Or More Verifiability: Capable Of Ec / Oimc Certification Calibration: Use 100Gm + / -0.1Mg Display: Led / Lcd Backlit Draft Shields: Glass Shield Function: Inter Counting , Percent Weighing, Weighing Read Out In Most Common International Units Leveling: Manual Adjustments: Internal Iso Calibration Printer With Statistical Option Note:- 1. Free Of Cost Installation. Demo And Training To Be Provided On Site. 2. Minimum Period Of Three Year Warranty For The Full Consignment Supplied From The Date Of Installation And Five Years Comprehensive Amc After Expiry Of Warranty Period. 3. All Other Spares , Consumables And Accessories Required For Operation Should Be Made Available For At Least Ten Years. 4. Nomenclatures / Units Should Be Followed As Per Our Specification Or Explained In Compliance Chart. 1. Weighing Capacity: Up To 600 G 2. Readability: 0.1Mg , Repeatability 1 Mg Or Less. 3. Linearity: + Or – 0.2 Mg. 4. Reproducibility: <= 0.1 Mg 5. Std. Dev : < +0.1Mg 6. Pan: 80Mm Or More. 7. Verifiability: Capable Of Ec / Oimc Certification. 8. Calibration: Use 100 Gm + / - 0.1 Mg. 9. Display: Led / Lcd Backlit. 10. Draft Shields: Glass Shield. 11 Function: Inter Counting, Percent Weighing, Weighing Read Out In Most Common International Units. 12 Leveling: Manual 13 Adjustments: Internal Iso Calibration Printer With Statistical Option Note:- 1. Free Of Cost Installation. Demo And Training To Be Provided On Site. 2. Minimum Period Of Three Year Warranty For The Full Consignment Supplied From The Date Of Installation And Five Years Comprehensive Amc After Expiry Of Warranty Period. 3. All Other Spares , Consumables And Accessories Required For Operation Should Be Made Available For At Least Ten Years. 4. Nomenclatures / Units Should Be Followed As Per Our Specification Or Explained In Compliance Chart. Digital Zone Reader Suitable To Measure The Diameter Of Inhibited Zone To 0.1Mm Within The Range Of 0 To 80.0Mm. Least Count 0.1Mm Resolution 0.1Mm Electronic Zero Adjustment Fine Focus Adjustment For Clear Image On The Viewing Glass. No Effect Of Ambient Light On Image. Halogen Light For Sharp & Bright Optical Imaging. Light Should Pass Through Transparent And Semitransparent Portion Of Agar And The Magnified Image Of The Zone Of Inhibition Can Be Clearly Seen On The Prism. Adjustable Belt To Facilitate Positioning Of The Dish Relative To Light Source. The Instrument Is Supplied Complete With All The Required Accessories Like Prism, Bulbs Etc. Power Required : 230V Ac ; 50Hz Note:- 1. Free Of Cost Installation. Demo And Training To Be Provided On Site. 2. Minimum Period Of Three Year Warranty From The Date Of Installation And Five Years Comprehensive Amc After Expiry Of Warranty Period. 3. All Other Spares , Consumables And Accessories Required For Operation Should Be Made Available For At Least Ten Years. 4. Nomenclatures / Units Should Be Followed As Per Our Specification Or Explained In Compliance Chart. Re- Validation / Re –Calibration Once In A Year From Nabl Certified Vendors 5 Point Calibration With Lcd Display With Printer Combined Glass Ph Electrode ( 0 To 14 Ph Accuracy + 0.02 ) Rtd For Temperature Sensing ( 0 To 99°C ) And With Printer Power Supply:100 – 300 V Ac; 47 To 63Hz Spare: Flat Surface Electrode Note:- 1. Free Of Cost Installation. Demo And Training To Be Provided On Site. 2. Minimum Period Of Three Year Warranty From The Date Of Installation And Five Years Comprehensive Amc After Expiry Of Warranty Period. 3. All Other Spares , Consumables And Accessories Required For Operation Should Be Made Available For At Least Ten Years. 4. Nomenclatures / Units Should Be Followed As Per Our Specification Or Explained In Compliance Chart. Re- Validation / Re –Calibration Once In A Year From Nabl Certified Vendors A System Complete With Illumination System Is Required For View Of Individual Cells, Even Living Ones With High Magnification Microscope Using 2 Eye Lenses To Reduce The Eyestrain. Body: • Body-Single Mold Sturdy Stable Base Stand, Inclined Binocular Body 30 Deg. 360 Deg. Rotatable Head With Focus Adjustment Controls. • A Durable Textured Acid Resistant Finish • All Optical Parts Including Objectives, Eye Pieces And Prisms Should Have Anti-Reflective Coating Which Also Gives Anti-Fungal Property. • All Metallic Parts Should Be Corrosion – Proof; Acid Proof And Stain-Proof. Eye Piece • -Highest Quality 10 X / 20Mm Wide Angle Anti Fungus Field Eye Pieces. One With Pointer. Diopter Adjustment Must Be Present On Both Eye Pieces. ( The Image Of The Object As Seen Through The Binocular Eyepiece Should Be Well Defined Centrally In At Least 2 / 3 Field Of View ) . • Achromatic, Wide Field, 10 Z With Inbuilt Pointer. • The Eyepiece Should Be Aplanatic And Have A Minimum Field Number Of 18 Diopter Adjustment Must Be Present On One / Both Eye Pieces Or On The Eye Piece Tube. Optical System • Optical System Should Be Infinity Corrected. • Built-In Led Light Source With White Light With Intensity Control And Led Life Of More Than 10, 000 Hrs. Objective • Parfocal, Antifungal Coated 4 X, 10X, 40X And 100X ( Oil Immersion ) With Semi Planner Achromatic Correction. • Objective Should Be Well Centered Even If Their Position On Turret Is Changed. • 10X And 40X Objectives Should Have Numerical Apertures Of 0.25 And 0.65 Respectively. • 100Xshould Have Numerical Aperture Of 1.25 And Should Be Of Oil Immersion. • Unbreakable Containers To Be Provided For Storing The Objectives. • All Objectives Should Be Wide Field, Achromatic And Par Focal. Nose Piece • Backward Tilted Revolving Nose Piece Suitable To Accommodate Four Objectives With Click Stop • It Should Be Provided With Rubber Ribbed Grip For Easy Rotation Mounted On A Precision Ball Bearing Mechanism For Smooth And Accurate Alignment. Extra Ports If Any Should Be Fitted With Dust And Fungal Proof Metallic / Ebonite Caps. Focusing: • Coaxial Coarse And Fine Focusing Knob, Capable Of Smooth, Fine Focusing Movement Sensitivity; Minimum: 300 Micron; Focusing Stop For Slide Safety. Stage • Stage Uniformly Horizontal, Mechanical Stage Having Dimensions Of Length 140 Mm ( + / - 20Mm ) With Fine Vernier Graduations ( Minimum Reading Accuracy Of 0.1 Mm ) . • It Should Be Designed With Convenient Sub-Stage Vertical Coaxial Adjustment For Slide Manipulation. • The Stage Should Have Ball-Bearing Arrangement To Allow Smooth Travel In Transverse Directions I.E. 80 Mm ( + / - 5Mm ) And Front To Back Direction, 50Mm ( + / -5Mm ) . Sub-Stage Condenser • Abbe-Type Condenser With Numerical Aperture ( N.A. ) 1.25 Focusable With Rack And Pinion Arrangement Incorporating A Spherical Lens And An Iris-Diaphragm. Sub-Stage Illuminator • The System Should Have A Build-In Variable Light Source ( Illuminator ) . • This Light Source Should Have A 20 W, 6 V Halogen Lamps. • The System Should Have A Build –In Variable Light Source ( Illuminator ) . • This Light Source Should Have A 20 W, 6 V Halogen Lamps. • The System Should Be Provided With A Step Down Transformer And An On-Off Switch And Intensity Control. • The Lamp Should Be Provided With A Lamp Socket Which Has The Facility For Easy Replacement Of The Bulb Power Supply & Protection • Voltage 220 V Ac, 50 Hz. Should Have One On-Off Power Switch. • A Plano-Concave Mirror In Fork Mounting Should Be Supplied Which Would Be Attachable To The Base For Field Use When Power Is Not Available. • Should Have Over-Charging Cut-Off With Visual Symbol. Battery Backup • Minimum 1 Hour Operating And Storage Conditions • Capable Of Operating Continuously In Ambient Temperature Of 10 To 50 Deg. C And Relative Humidity Of 15 To 90% In Ideal Circumstances. • Storage Condition: Capable Of Being Stored Continuously In Ambient Temperature Of 0 To 50 Deg. C And Relative Humidity Of 15 To 90%. Manual Accessories • Working Manual Should Be Provided With Each Microscope. • Immersion Oil 25 Ml X 2 • Lens Tissue Paper 2 Rolls Or Boxes • Lens Cleaning Solution ( 100Ml ) • One Anti-Static Cleaning Brush. • The Unit Shall Be Capable Of Being Temperature Of 0 – 50 Deg. C And Relative Humidity Of 15-90%. Note: - Free Of Cost Installation, Demo And Training To Be Provided On Site • Minimum Period Of Three Year Warranty From The Date Of Installation And Five Years Comprehensive Amc After Expiry Of Warranty Period • All Other Spares, Consumables And Accessories Required For Operation Should Be Made Available For At Least Ten Years Nomenclatures / Units Should Be Followed As Per Our Specification Or Explained In Compliance Chart. Re- Validation / Re –Calibration Once In A Year From Nabl Certified Vendors Operating Frequency 33+ / -3 Khz, For All General Purpose Cleaning Is Highly Recommended. Input Voltage: Range Of 170V Ac-270V Ac, 50Hz, Iph. Micro Controller Based Timer Range: 0 To 30 / 99 Minutes Thermostatic Controlled Temperature Controller. Capacity: 3.5 Lit. Tank Size: ( Lxbxh ) Mm 300X150x100 Over All Dimension ( Lxbxh ) Mm 330X175x250 Wattage : 120W Note: - 1. Free Of Cost Installation, Demo And Training To Be Provided On Site 2. Minimum Period Of Three Year Warranty From The Date Of Installation And Five Years Comprehensive Amc After Expiry Of Warranty Period 3. All Other Spares, Consumables And Accessories Required For Operation Should Be Made Available For At Least Ten Years. 4. Nomenclatures / Units Should Be Followed As Per Our Specification Or Explained In Compliance Chart. Capacity: 5 Liters With Easy Cleaning Facility Material Of Construction: Body Should Be Compact, Durable, Leak Proof Ad Made Of Stainless Steel / Heavy Duty Plastic Particle Size: • It Should Produce Aerosols With Particle Size Of Less Than 5 Microns • The Blower Head Should Be Rust Proof Inert To Formaldehyde, Kmn04, H2o2 And Deliver Aerosols Uniformly. Unit • It Should Be Compatible With All Disinfectant Solutions Usual Concentration. • It Should Be Compatible With Maximum Ph Range ( Both Acid And Alkali ) . • The Equipment Should Be Of Good Quality And Conform To National / International Standards. Power Supply The Machine Should Operate On 220+ / - 10 Volts, 50 Hz, Single Phase, A.C Provided With Cable Should Be At Least 5 Meters In Length, Isi Marked. Operation The Discharge Rate Should Not Be Less Than 1 Liter / 25 Minutes. The Tank Capacity, Discharge Rate And Timer On The Machine Should Be So That The Disinfectant Should Be Able To Disinfect 4000-5000 Cubic Feet In One Cycle Of 2 Hours ( Max ) . Note: - 1. Free Of Cost Installation, Demo And Training To Be Provided On Site 2. Minimum Period Of Three Year Warranty From The Date Of Installation And Five Years Comprehensive Amc After Expiry Of Warranty Period 3. All Other Spares, Consumables And Accessories Required For Operation Should Be Made Available For At Least Ten Years. 4. Nomenclatures / Units Should Be Followed As Per Our Specification Or Explained In Compliance Chart. Re- Validation / Re –Calibration Once In A Year From Nabl Certified Vendors• Material: Abs Plastic. Specifications Of Steam Pot  The Special Digestor Should Be Designed To Use For Bulk Media Digestion At 100ºc / Boiling Water Temperature & Also Other General Purpose In Microbiology Lab.  The Rectangular Bath Should Have Chamber Size In Such A Way That, It Can Accommodate 6 Nos Erlenmeyer Flask Of 2000 Ml Or 6 Nos Duran Bottles Of Capacity 5000 Ml.  It Should Have Volume Of Around Aprox 80 -100 Ltr. Media Digestor Should Be Provided With Stainless Steel Stand. It Should Have Full Stainless Steel Ss304 Double Walled Construction With Thickness Of Minimum 1Mm & Insulation For Preventing Energy Losses. Lid Should Be Made Of Ss304 & Should Have Assisted Lift For Easy Opening As Well As Effortless Loading & Removal Of Flasks. It Should Have Easy To Operate Lid Latching Design Fitted On Flat Insulated Double Wall Lid. Lid Latching Handle Should Be Made Of Stainless Steel And Suitably Coated With Cool To Touch Sleeve. Drip Tray Should Be Provided Below The Lid Inside Chamber To Avoid Dripping Of Condensate On To The Flasks / Bottles. It Should Be Provided With Ss Wire Mesh Heater Cover For Efficient Steam Movement And Stable Placement Of The Flasks / Bottles. It Should Have Drain Valve For Draining Chamber Water. It Should Be Provided With An Open Port With Nozzle At Top Of The Lid For Venting Of Steam. It Should Be Provided With Validation Port - For Inserting Additional Sensors - Provided As Part Of Standard Supply. It Should Be Provided With Silicon Gasket Affixed To The Lid To Ensure Leak Proof Operation Even At 100ºc / Boiling Water Temperature. It Should Be Provided With User Settable Pid Digital Temperature Controller With Timer. Temperature Range: Ambient +5 To 100ºc ( Boiling Water Temperature ) . It Should Have Accuracy: ±1ºc & Resolution: 1ºc. It Should Be Provided With Mcb For Electrical Safety.Note:- 1. Free Of Cost Installation. Demo And Training To Be Provided On Site. 2. Minimum Period Of Three Year Warranty From The Date Of Installation And Five Years Comprehensive Amc After Expiry Of Warranty Period. 3. All Other Spares , Consumables And Accessories Required For Operation Should Be Made Available For At Least Ten Years. 4. Nomenclatures / Units Should Be Followed As Per Our Specification Or Explained In Compliance Chart. Re- Validation / Re –Calibration Once In A Year From Nabl Certified Vendors The Vortex Mixer Shall Be Able To Mix Short, Rapid Eccentric Stroke. Motor Driven Neoprene Cup And Capable Of Importing Vigorous Agitation To Small Samples In Test, Centrifuge To Colon Meter Tubes, Erlenmeyer Flasks Up To 100 Ml. Construction Shall Be Provided With Vibrating Plate, Foam Pad And Power Cord Mounted On Vacuum Rubber Feet And On / Off Switch. Workable On 220V Ac, Dimensions Approx. 170 X 110 X 150 Mm Note: - 1. Free Of Cost Installation, Demo And Training To Be Provided On Site 2. Minimum Period Of Three Year Warranty From The Date Of Installation And Five Years Comprehensive Amc After Expiry Of Warranty Period 3. All Other Spares, Consumables And Accessories Required For Operation Should Be Made Available For At Least Ten Years. 4. Nomenclatures / Units Should Be Followed As Per Our Specification Or Explained In Compliance Chart Chairs Stainless Steel 304 Quality Matt Finish Seat Height: 1Ft 10Inches With Upright Straight Back Without Arms Rounded Edges

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 04-Nov-2022 tender extention Date 10-11-2022

Key Value

Document Fees
INR 5000 /-
EMD
INR 62500.0 /-
Tender Value
INR 25 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail