Military Engineer Services-MES has published Tender For Repair/ Maint To Roof, Water Tanks, Cleaning Of Existing Sewage System And Certain E/M Works At Af Station Dadri And Aor Of Ge (Af) Faridabad. Submission Date for this Tender is 16-11-2022. Sewerage Construction Tenders in dadri Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

34456801
Corrigendum : Tender For Repair/ Maint To Roof, Water Tanks, Cleaning Of Existing Sewage System And Certain E/M Works At Af Station Dadri And Aor Of Ge (Af) Faridabad
Open Tender
Indian
Uttar Pradesh
dadri
16-11-2022

Tender Details

Repair / Maintenance To Roof, Water Tanks, Cleaning Of Existing Sewage System And Certain E / M Works At Af Station Dadri And Aor Of Ge ( Af ) Faridabad

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-Nov-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 16-11-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 60000.0 /-
Tender Value
INR 30 Lakhs /-

BOQ Items

Name of Work:REPAIR/ MAINT TO ROOF, WATER TANKS, CLEANING OF EXISTING SEWAGE SYSTEM AND CERTAIN E/M WORKS AT AF STATION DADRIAND AOR OF GE (AF) FARIDABAD
Sl. No. Item Description
1Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer-in-Charge.
2M&L for RCC 1:2;4 B0 (using of 12.5 mm Stone Aggregate) Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs and in shelves and chajjas complete all as specified and directed by Engineer-in-Charge.
3M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) complete all as specified and directed by Engineer-in-Charge.
4M&L for 10 mm dia and over TMT bar cut to length bent to shape required including cranking bending spirally for hoping for columns hooking ends binding with MS wire n.exc 0.9mm or with securing clips etc complete all as specified and directed by Engineer-in-Charge.
5M&L for 6 to 8 mm dia TMT bar cut to length bent to shape required including cranking bending spirally for hoping for columns hooking ends binding with MS wire n.exc 0.9mm or with securing clips etc complete all as specified and directed by Engineer-in-Charge.
6Taking down cement plaster from brick or stone masonry or concrete surfaces and hacking for key and scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
7M&L for rendering 15 mm thick in CM 1:4 onstone/brick masonary or surface other than fair face of brick works etc or similar surfacescomplete all as specified and directed by Engineer-in-Charge.
8M&L 15 mm thick rendering in cm 1:6 on brick surfaces or concrete surfaces finished even and smooth without using extra cement incl mixing of water proofing liquidof Dr. fixit as per manufactrer instruction complete all as specified and directed by Engineer-in-Charge.
9M&L for rendering 10mm thick in CM 1:3 onconcrete surface in ceillings etcincluding with mixing of water proofing liquidof Dr. fixit as per manufactrer instruction complete all as specified and directed by Engineer-in-Charge.
10M&L for preparation of new plastered surfaces and applying two coats of cement base paint on walls over a coat of alkali resistant priming paint complete all as specified and directed by Engineer-in-Charge.
11M&L two coat of oil bound distemper after 3mm Birla/JK wall care putty on new plastered surfaces including necessary prepararion complete all as specified and directed by Engineer-in-Charge.
12M&L three coat of white wash on new surfaces on ceiling including necessary prepararion complete all as specified and as directed by Engr-in-Charge..
13Taking down existing water proofing treament any nos of layers and of any description, incl.demolition and taking off PCC padding/plaster on RCC slab,also including removing of bitument coating to show the concrete surfaceto its true colour and roughening etc and also removing the debris outside the MOD land complete all as specified and directed by Engineer-in-Charge.
14Taking down existing mud puska any nos of layers and of any description, including removing of the debrisoutside the MOD Land up to distance 250 mtr complete all as specified and directed by Engineer-in-Charge.
15Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 including macthing existing surfaces complete all as specified and directed by Engineer-in-Charge.
16M&L Cement concrete type B-0, 1:2:4 (12.5 mm graded aggregate) on roof paddingavg. thicknessof 40mmin slope finished even and fair complete all as specified and directed by Engineer-in-Charge.
17M & L for20 mm thick Screed bed in cement mortar 1:3 mixed with integral water proofing compound @ 3% by weight of cement complete all as specified and directed by Engineer-in-Charge.
18M & L for laying APP modified membarane with non woven polyester reinforcement mat (concrete core) not less than 3 mm thick & not less than 3.5 kg /sqm, the over the lap otching shall be 100 mm on length side & 100 mm on widthe sideover a tack coat of Industrial bitumen of 1.20 kg / Sqm over Bituminious based primer IS No. 3383@ 250 gms/sqm including apply of Aluminium colour synthetic enamel paint @ 200 gms/sqm all as per manufacture"s instruction complete all as specified and directed by Engineer-in-Charge. Note: Supply only integral water proofing compound shall be measured and paid separately.
19Supply only integral water proofing liquid ( ISI marked) complete all as specified and directed by Engineer-in-Charge.
20Taking up or down steel water tubing and connection incl cleaning for refixing or removal to stores for following bore complete all as specified and directed by Engineer-in-Charge :- (a) 15mm
21All as per item No 20 above but 20mmcomplete all as specified and directed by Engineer-in-Charge
22Refixing old steel tubing and connections in new or old position on wall, ceiling, floor etc of 15 mm dia complete all as specified and directed by Engineer-in-Charge
23Refixing old steel tubing and connections in new or old position on wall, ceiling, floor etc of 20 mm dia complete all as specified and directed by Engineer-in-Charge
24S&F GI tubes medium grade with all fitting and fixed complete to walls and ceiling or laid in floor in following bore of tube complete all as specified and directed by Engineer-in-Charge :- (a) 15mm
25All as per item No 24 above but 20mmcomplete all as specified and directed by Engineer-in-Charge
26S&F in repair 20 MM Gun-metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe and fixed in repair and complete all as specified and directed by Engineer-in-Charge
27S& Fix in repair 15 mm bore Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed in repair and complete all as specified and directed by Engineer-in-Charge
28S&F in repair 20mm bore Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed in repair and complete all as specified and directed by Engineer-in-Charge
29S&F in repair rotational moulded polyethylene water storage tanks (cylinderical, vertical with closed top) of 1000 Ltrs capacity hoisted and fixed in position complete all as specified and directed by Engineer-in-Charge
30S&F rotational moulded polyethylene water storage tanks (cylinderical, vertical with closed top) of 500 Ltrs capacity hoisted and fixed in position complete all as specified and directed by Engineer-in-Charge
31Cleaning and removal all scale and dirt, etc, from tanks and mouth of circulating pipes, etc exc 250 & n.exc500 litres capacity including to be write the date of cleaning with synthetic enamel paint complete all as specified and directed by Engineer-in-Charge
32Cleaning and removal all scale and dirt ,etc ,from tanks and mouth of circulating pipes ,etc exc 500 & n.exc 1000 litres capacity including to be write the date of cleaning with synthetic enamel paint complete all as specified and directed by Engineer-in-Charge
33Demolition & breaking up drain pipes (salt glazed stoneware, AC or reinforced concrete) set in cement mortar, internal dia of pipe 100 mm complete all as specified and directed by Engineer-in-Charge
34All as per item No 33above but bore of pipe 150 mm complete all as specified and directed by Engineer-in-Charge
35All as per item No 33above but bore of pipe 200 mm complete all as specified and directed by Engineer-in-Charge
36M&L 100 mm internal dia salt glazed stone ware drain pipes laid in trenches and jointed complete all as specified and directed by Engineer-in-Charge
37All as per item No 36 above but bore of pipe 150 mm complete all as specified and directed by Engineer-in-Charge
38All as per item No 36 above but bore of pipe 200 mm complete all as specified and directed by Engineer-in-Charge
39S & F in repair PVC 110 mm (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with clamps and for sewage line complete all as specified and directed by Engineer-in-Charge
40S & F in repair PVC 110 mm (SWR) bends any radius complete all as specified and directed by Engineer-in-Charge
41S & F in repair PVC (SWR), junction single, (Single T) equal or unequal 110 mm complete all as specified and directed by Engineer-in-Charge
42M&L concrete bed to 100 mm bore drain pipes in cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregates including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed by Engineer-in-Charge
43All as per item No 42 above but bore of pipe 150 mm complete all as specified and directed by Engineer-in-Charge
44All as per item No 42 above but bore of pipe 200 mm complete all as specified and directed by Engineer-in-Charge
45Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50 min depth for manholes & sewage lines and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge
46Demolition of brick work built in cement mortar of any description complete all as specified and directed by Engineer-in-Charge
47Demolition of cement concrete ofany description and in any position as in bed of drain pipes etc complete all as specified and directed by Engineer-in-Charge
48M&L cement concrete type C-21:3:6 ( 40 mm graded aggregate) as in foundation, filling and mass concrete complete all as specified and directed by Engineer-in-Charge
49M & L for brick work with sub class "B" Bricks straight or curved on plan exceeding 6m mean radius built in cement mortar 1:4 as in manholes and drain complete all as specified and directed by Engineer-in-Charge
50M&L for providing cement concrete 1:2:4, type B1, using 20 mm graded stone aggregates as in coping complete all as specified and directed by Engineer-in-Charge
51M&L PCC 1:2:4 type B2 as in surface channels and drains & benching of manholes and finishing even and smooth with out using extra cement complete all as specified and directed by Engineer-in-Charge
52Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed by Engineer-in-Charge
53Removing excavated materialsto a distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed by Engineer-in-Charge
54Cutting into existing manholes for connecting new drains, making good to pipes and rendering, cutting out existing benching for & forming branch channel (1/2 round or 3/4 Section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required, Internal dia of pipe 150mm complete all as specified and directed by Engineer-in-Charge
55All as per item No 54above but bore of pipe 100 mm complete all as specified and directed by Engineer-in-Charge
56All as per item No 54 above but bore of pipe 200 mm complete all as specified and directed by Engineer-in-Charge
57S&F in repairs cast iron Nahani trap with grating including jointingto waste pipe, fixed in cement concrete 1:2:4, type B-1, using 20 mm graded stone aggregate, dia of outlet 100 mm complete all as specified and directed by Engineer-in-Charge
58S&F in repairs for Vitreous China squatting pan,"Orissa" pattern,size 580 X440 mm white,withintegral foot rests (excluding flushing cistern and flush pipe) including connection to flushing pipe anti syphonage pipe etc complete all as specified and directed by Engineer-in-Charge
59S&F in repair vitreous Chinawash down water closet (EWC) pedestal pattern colouredincl P or ‘S’ trapcoloured ,seat cover & cement concrete bedding complete all as specified and directed by Engineer-in-Charge
60S&F PVC valveless,symphonic action type,flushing cistern ,low level white,with inlet,ball valve,float and handle including brackets of 10 ltrs complete all as specified and directed by Engineer-in-Charge.
61S&F in repair PVC flush bend 32mm dia with two Nos check nuts for conencting low level flushing cistern to European type water closet or India type water closet incl cement joint complete all as specified and directed by Engineer-in-Charge
62Dismantling floor hearth or wall tiling including cement mortar bedding (But not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge
63M&L forcoloured printed non skid tiles area of each tile exceeding exc 0.06 sqmbut n.exc 0.11 sqm in floors etc set and jointed with neat cement slurry pointed with colour cement to match the floor, and including 15 mm thick screed bed cement mortar in CM 1:4 and including the chipping of the existing PCC floor complete all as specified and directed by Engineer-in-Charge
64M&L fordigital glazed ceramic tiles coloured size 300 x 200 x 7mm thickas on vertical surfaces, of walls as in skirting, dado etcset and jointed in neat cement slurry & pointed with colouredcement to match complete all as specified and directed by Engineer-in-Charge
65Dismantling of stone slabs & tiles of any description or thickness (except ceramic tiles) in floors, aprons etc laid bedded & pointed in any mortar complete all as specified and directed by Engineer-in-Charge
66Demolition of cement concreteunreinforced in groundfloors andpavingsnot exc15cm thickness below or above ground level etc complete all as specified and directed by Engineer-in-Charge
67M&L 75 mm thickPCC1:4:8typeD-2 (using 40mm grade stone aggregate)asinSub floors,Sub bases ,flooring etc complete all as specified and directed by Engineer-in-Charge
68M&L cement concrete 75 mm thicktype C-2 1:3:6 ( 40 mm graded agg ) as in plinth protection etc complete all as specified and directed by Engineer-in-Charge
69M & L for Rubber moulded Chequeredcement concrete tiles30 cm x 30 cm x 25 mm thick set , jointed and pointed in neat cement slurryin floorswith gray cement and pigment with screed bed 15 mm CM 1:6 complete all as specified and directed by Engineer-in-Charge
70M & L for Machine pressed precast concrete interlocking paver block any shape and size with grey cement and coloured pigment confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade over 25mm thick coarse sand complete all as specified and directed by Engineer-in-Charge
71M&L for Sand filling under floors or in foundation including watering and consolidating complete all as specified and directed by Engineer-in-Charge
72Providing, precast cement concrete1:2:4 type B1 (20 mm graded aggregate) in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces etc. and setting in mortar complete with joints to match complete all as specified and directed by Engineer-in-Charge
73Dismantling wrought iron or mild steel / structural steel of any description not otherwise provided complete all as specified and directed by Engineer-in-Charge
74Cleaning of pipe drains by jet mechine 100mm internal dia drain pipe upto1.50 m in depth and removal of sludge/silt/liquid/mud and sand (in foul position) etc out side the MOD land including testing of drains by filling the pipes with water complete all as specified and directed by Engineer-in-Charge
75All as per item No 74 above but cleaning of 150mm internal dia drain pipe not exceeding 1.5m in depth complete all as specified and directed by Engineer-in-Charge
76Cleaning of manhole upto 1 m depth and removal of sludge silt/liquid/mud/sand/water etc in foul position to out side the MOD land complete all as specified and directed by the Engineer-in-Charge.
77All as per item No 76 above but exceeding 1m and not exceeding 2m in depth complete all as specified and directed by Engineer-in-Charge
78Dewatering/desilting of septic tanks,soak wells etc cleaning of all sludge,silt residue of both organic and inorganice nature by manual labour or mechnical scrappers etc and disposal of the same out side the defence land incl dumping the material to any depth complete all as specified and directed by Engineer-in-Charge
79Taking down carefully aluminium point wiring/sub main wiring light, fan socket or power complete fitting such as switches, ceiling rose, fan regulator, socket including light fitting etc complete with MS conduit and T/W battern and depositing to MES store yard complete all as specified and directed by Engineer-in-Charge
80M&L for Re wring with Modular /single core PVC insulated unsheathed 1100 volt grade cable with multistranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit / cassing capping / concelled as per ground requirement medium duty ISI marked not less than 20mm dia, fixed in wall, on roof with GI saddles GI screws, rawal plugs (concealed conduit in wall wiring) with all fittings including Tee, junction boxes and provision of pressed steel terminal box of suitable size with 3 mm thickhylamlaminated white sheet cover for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 volts grade cable with multistranded coper conductor of size 1.5 Sq mm (Nominal area) complete all as specified and directed by Engineer-in-Charge
81M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade cable with multistranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, fixed in wall, on roof with GI saddles GI screws, rawal plugs (concealed conduit in wall wiring) with all fittings including Tee, junction boxes and provision of pressed steel terminal box of suitable size with 3 mm thickhylamlaminated white sheet cover for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 volts grade cable with multistranded coper conductor of size 1.5 Sq mm (Nominal area) complete all as specified and directed by Engineer-in-Charge for following (Color coding to be followed) :- (a)One light/fan point controlled by one switch.
82All as per item as per item No 81 but Onesocket point on same board with other switches complete all as specified and directed by Engr -in- Charge.
83Allas per item No 81 above but with One 3 pin 5 Amps socket outletindependent with cables 1.5 sqmm size complete all as specified and directed by Engineer-in-Charge
84All same as per item No 81 above but with One bell/buzzer point controlled by one bell push complete all as specified and directed by Engineer-in-Charge
85Allas per item No 81 above but with conductor of size 2.5 Sq mm (nominal area) for one 3 pin socket outlet 15 Amps on independent board complete and earth continuity wire with 1.5 Sq mm PVC insulated stranded copper conductor cable complete all as specified and directed by Engineer-in-Charge
86M&L for Sub main wiring with twosingle core, 6 Sqmm, PVC insulated PVC unsheathed stranded FR copper conductor cablein and including PVC concealed/ surfaceconduit of earth wire with 1 x4 Sq mmcopper cable fixed along with the sub main in PVC conduit and connecting to earth dollycomplete all as specified and directed by Engineer-in-Charge
87M&L for Sub main wiring with twosingle core, 4 Sqmm, PVC insulated PVC unsheathed stranded FR copper conductor cablein and including PVC concealed/ surfaceconduit of earth wire with 1 x 2.5 Sq mmcopper cable fixed along with the sub main in PVC conduit and connecting to earth dollycomplete all as specified and directed by Engineer-in-Charge
88M&L for switch piano type 5 Amps, single pole one way complete all as specified and directed by Engineer-in-Charge
89S&F Modular switch 1 way 6A, 1 module complete all as specified and directed by Engineer-in-Charge
90M&L for switch piano type 15 Amps, single pole one way complete all as specified and directed by Engineer-in-Charge
91S&F Modular switch 1 way 16A, 1 module complete all as specified and directed by Engineer-in-Charge
92S&FBell push 6A 1 module complete all as specified and directed by Engineer-in-Charge
93S&F Modular Bell push 6A 1 module complete all as specified and directed by Engineer-in-Charge
94M & L for socket outlet 5 pin , 5 Amps flush type complete all as specified and directed by Engineer-in-Charge
95S&F Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed by Engineer-in-Charge
96M&L for socket outlet2 in 1, 3 pin, 5 and 15 Amps Flush type complete all as specified and directed by Engineer-in-Charge
97S&F Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed by Engineer-in-Charge
98S & F stepped type electronic fan regulator flush type complete all as specified and directed by Engineer-in-Charge
99S & F Fan step regulator, 120W - 2 module complete all as specified and directed by Engineer-in-Charge
100S & Fin replacement lamp holder insulated body threaded deme, with back plate,button/ angular type with sutable for battern fitting complete all as specified and directed by Engineer-in-Charge
101S&F for ceiling rose surface bakelite 65x50mm two to three terminals complete all as specified and directed by Engineer-in-Charge
102S&F White cover plate with frame,1 module complete all as specified and directed by Engineer-in-Charge
103Allas per item No 102 above butbut 3 module complete all as specified and directed by Engineer-in-Charge
104Allas per item No 102 above butbut 6 module complete all as specified and directed by Engineer-in-Charge
105Allas per item No 102 above butbut 8 module complete all as specified and directed by Engineer-in-Charge
106S&F Metal flush box/ PVC box 1/2 module complete all as specified and as directed by Engr-in-Charge.
107Allas per item No 106 above butbut 3 module complete all as specified and directed by Engineer-in-Charge
108Allas per item No 106 above butbut 6/8 module ccomplete all as specified and directed by Engineer-in-Charge
109S&Fin repair call bell ding dong type 230 volt single phase complete set inclusive suitable size wire from ceiling rose to calling bell complete all as specified and directed by Engineer-in-Charge
110S&F Exhaust fan 10"/12" sweepcomplete all as specified and directed by Engineer-in-Charge
111S&F PVC Exhaust fan 300MM sweepcomplete all as specified and directed by Engineer-in-Charge
112Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose,complete with all accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable and tubes wit suitable size complete all as specified and directed by Engineer-in-Charge
113Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge
114S & F Recess mounted LED Light Fitting 15 Wattpressure die-cast aluminium luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation and incl separate replaceable electronic driver compatible forAnalog/DALI Dimming complete all as specified and as directed by Engr-in-Charge.
115S&F in replacementEdgelit LED slim panellight fitting 2"x2"40 watt having powder coated extruded Aluminium body with high quality LGP and PMMA diffuser swparate HPF driver suitbale for Armstrong and grid ceilling6000 K , including connecting up with twin core twisted flexible copper cable with suitable size complete all as specified and directed by Engineer-in-Charge
116S & F Electronicdrivers suitable to fixRecessed mounted LED Light Fitting 15 Watt round shapedcomplete all as requredon site for smooth functioning of lights complete all as specified and directed by Engineer-in-Charge
117S & F Electronicdrivers suitable to fixRecessed mounted LED Light Fitting2"x2" 40Watt6000 K/5400K completemake and modelall as requredon site for smooth functioning of lights complete all as specified and directed by Engineer-in-Charge
118S & F MCCB 4 pole125 Amps 16 kAcomplete all as specified and as directed by Engr-in-Charge.
119S& F Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB complete all as specified and directed by Engineer-in-Charge
120S&F MCB DB double door Single pole & neutral 8 way with 200 amps rated bus bar complete all as specified and directed by Engineer-in-Charge
121S&F MCB DB double door Single pole & neutral 12 way with 200 amps rated bus bar complete all as specified and directed by Engineer-in-Charge
122Supply and fixing amp rating 240V, SP 5 To 32 AMP 10KA "C" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-Charge
123Supply and fixing amp rating 240V, SPN 40 To 63 AMP 10KA "C" curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-Charge
124M&L for Taking down carefully water heaterstorage type 25/50 Ltrs capacity for repair and over hauling and opening to gysers and comprising of heating element , thermostate switch,electric connetions cleaning and descaling with descaling solutionthe geyser tank andchecking of leakage on pressure at 150 PSI and testing for smooth fuctioning complete all as specified and directed by Engineer-in-Charge
125S & F in Replacementof heating elementsuitable for geysers any type as site requirement ISI mark complete all as specified and directed by Engineer-in-Charge (a) 2.00 KW Capacity 230 Volts
126All as per item ser No125above but 1.50 KW Capacity 230 Volts complete all as specified and directed by Engineer-in-Charge
127S & F in replacement thermostat switch any type suitable for geyser of any size/model complete all as specified and directed by Engineer-in-Charge
128S & F Geyser assy ( rupturing plate or U assembly) any make and type for 50 Ltrs capacitywater heater incl replacement of rubber seal nuts and bolts complete all as specified and directed by Engineer-in-Charge
129All as per item No 128 above but for 25Ltrs capacity complete all as specified and directed by Engineer-in-Charge
130S & F in replacementof indcationlamp (pilit type ISI marked) for 50 / 25Ltrs water heater complete all as specified and directed by Engineer-in-Charge
131Supply and fixing in replacementof PVC insulated flexible copper conductor cable 40/0.0076 size 3 core suitablefor 650 volts grade complete all as specified and directed by Engineer-in-Charge
132S & F in replacement of glass wool in any capacity of geyser complete all as specified and directed by Engr - in- charge.
133S & Fin replacementofwater storage tank of geyser suitable for 50 Ltrs capacity complete all as specified and directed by Engr - in- charge.
134All as per item ser No133above but for 25 Ltrs capacity complete all as specified and directed by Engineer-in-Charge
135M & Lfor repair welding brazing of coppertank upto 25 mm to10mm long leak proof complete all as specified and directed by Engineer-in-Charge (Capacity 25 / 50 Ltrs).
136S & F in Replacementof bottom cover suitable cylindrical type geyser as per existingad required at site for the following sizecomplete all as specified and directed by Engineer-in-Charge (a) 50 Ltrs capacity
137All as per item No 136 above but 25 Ltrs Capacity complete all as specified and directed by Engineer-in-Charge
138M&L for servicing,Taking down ceiling fan 56"/48" sweep removing cleaning of dust, properly cleaning greasing of bearing including replacing and painting connecting up complete all as specified and directed by Engineer-in-Charge
139Supply and fixing capacitor, capacity 2.5 mfd in replacement complete all as specified and directed by Engineer-in-Charge
140Supply and fixing capacitor, capacity 3.15 mfd in replacement complete all as specified and directed by Engineer-in-Charge
141M&L for rewinding of burnt ceilingfan motor 1200/1400 mm sweep with super enamelled copper winding wire of suitable guage as per details of anymake /model complete all as sepecified and directed by Engr -in-Charge.
142Supply and replacement of ball bearingof ceiling fan of any size complete all as specified and directed by Engineer-in-Charge
143Supply and fixing and connecting flexible copper twisted twin core of size 23/00076complete all as specified and directed by Engineer-in-Charge
144M&L for servicing ofwall mountingfan motor 400 mm sweepwithsuper enamelled copper winding wire of suitable guage as per details details of anymake /model complete all as specified and directed by Engineer-in-Charge
145S&Fwall mountingfan motor for 400 mm sweepcomplete all as specified and directed by Engineer-in-Charge
146M&L for servicing of Exhaust fan of any size complete all as specified and directed by Engineer-in-Charge
147M&L for Exhaust fan motor for 300 mm sweep complete all as specified and directed by Engineer-in-Charge
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail