Tender For Spl Repair/ Replacement Of Distribution Board, Sub Main Wiring And Other Connected Items At Q Zone Under Ge (East ) Ferozepur Cantt, ferozepur-Punjab

Military Engineer Services-MES has published Tender For Spl Repair/ Replacement Of Distribution Board, Sub Main Wiring And Other Connected Items At Q Zone Under Ge (East ) Ferozepur Cantt. Submission Date for this Tender is 02-11-2022. Coats and Jackets Tenders in ferozepur Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

34439001
Tender For Spl Repair/ Replacement Of Distribution Board, Sub Main Wiring And Other Connected Items At Q Zone Under Ge (East ) Ferozepur Cantt
Open Tender
Indian
Punjab
ferozepur
02-11-2022

Tender Details

Special Repair / Replacement Of Distribution Board, Sub Main Wiring And Other Connected Items At Q Zone Under Ge ( East ) Ferozepur Cantt-Taking Down Carefully Unserviceable Main Switches And Distribution Boards With Fuses / McbS ( Single Phase Or Three Phase ) Of Any Capacity Complete All As Directed And Specified. 2 Taking Down Carefully Old Unserviceable Sub Main Wiring Including Meters And Making Good Disturbed Surfaces And Matching With Existing Complete All As Directed And Specified. 3 S&F Factory Made Three Phase And Neutral Sheet Steel Made Out Of Crca 1.2 Mm Thick, Powder Coated Double Door Vertical Distribution Board 4 Way, Dust And Vermin Proof, Fitted With Two Cover, One Screwed Cover For Incoming And Outgoing Mcbs And The Second For Protection Of Mcbs Fitted With Colour Bus Bar Of Capacity 200 Amps, Neutral Link, Earth Bar And Din Rail Suitable For Use On 240 / 415V, 50Hz Supply, Vtpn Db, Partly Immersed In Wall, Including Of Mccb 4 Pole Adjustable Thermal & Fixed Magnetic Type 100 Amps, 50Hz, 415 Volts With Rupturing Capacity 16 Ka And Making Good Distrubbed Surfaces With Matching Colour, Complete All As Specified. 4 S&F Factory Made Single Phase And Neutral Sheet Steel Made Out Of Crca 1.2 Mm Thick, Powder Coated Double Door Vertical Distribution Board 8 Way, Dust And Vermin Proof, Fitted With Two Cover, One Screwed Cover For Incoming And Outgoing Mcbs And The Second For Protection Of Mcbs Fitted With Colour Bus Bar Of Capacity 200 Amps, Neutral Link, Earth Bar And Din Rail. Suitable For Use On 240V, 50Hz Supply, Partly Immersed In Wall And Making Good Distrubbed Surfaces With Matching Colour, Complete All As Directed And Specified. 5 S&F Mcb Spn, 40A - 63Amps, 240 Volts, C Series, 10Ka Duly Isi Marked, In Mcb Db, Complete With Connection Testing And Commissioning Complete All As Directed And Specified. 6 S&F Mcb Sp, 6A-32 Amps, 240 Volts, B Series, 10Ka Duly Isi Marked, In The Mcb Db, Complete With Connection Testing And Commissioning Complete All As Directed And Specified. 7 M&L For Sub Main Wiring With Two Single Core 2X6 Sqmm Frls Insulated And Unsheathed Stranded Copper Conductoralongwith Earth Wire 6.0 Sqmm Frls Drawn In And Including Rigid Conduit Connected To Main Board Complete All As Specified And Directed ( Note: Two Runs Cable And One Number Earth Wire And Suitable Conduit Shall Measured Together As Unit Length ) . 8 M&L For Disconnecting Electric Meter Of Any Cap And Refixing Same After Rewiring, In Meter Box Including Connection Frls Complete All As Directed And Specified. 9 M&L Forearth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit / Pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc As Required 4 Mm Dia Galvanised Iron Or Steel Wire Complete All As Directed And Specified. 10 S&F Xlpe Insulated, Armoured, 1100 Volts Grade, Heavy Duty Cable Of Size 25 Sqmm Nominal Cross Section, 4 Core, Aluminium Conductor, Served With Inner Sheathing Of Galvanized Steel Wire Or Tape And Over-All Pvc Sheathed In Service Connections, Laid In Trenches, Duct, Through Pipe, In Floor, On Pole Including Jointing With Double Compression Copper Stain Less Steel Gland At Dbs And Testing, Complete All As Directed And Specified. ( Note:- Excavation & Earth Work, Brick Protection And Sand Cushionshall Bemeasured And Paid Separately ) 11 S&F Xlpe Insulated, Armoured, 1100 Volts Grade, Heavy Duty Cable Of Size 10 Sqmm Nominal Cross Section, 2 Core, Circular, Pvc Insulated Aluminium Conductor, Served With Inner Sheathing Of Galvanized Steel Wire Or Tape And Over-All Pvc Sheathed In Service Connections, Laid In Trenches, Duct, Through Pipe, In Floor, On Pole Including Jointing And Testing, Complete All As Directed And Specified. ( Note:- Excavation & Earth Work, Brick Protection And Sand Cushionshall Bemeasured And Paid Separately ) 12 S & F In Repairs, Installation, Commissioning And Testing Polycarbonate Asta Cpri Approved Oem Made Meter Enclosure. The Meter Box Shall Be Made Of Modular Polycarbonate Thermoplastic Enclosures Which Should Be Uv Resistance In Accordance With Iec 61439-1, Clause 10.2.4: The Meter Box With The Provision For 6 Nos Single Phase Meters With Provided Bakelite Sheet At The Bottom Of Meters ( Size 600 X 600 X 170Mm ) . Meter Box Type Wall Mounted Type On Mounting Structure Ral 7016, Anti-Acid, Anti Corrosive & Fully Transparent Door For Meter Vision With Four Side Screw Drive Operated Locking . Degree Of Protection Ip 65 In Accordance With Iec 60529 And Against Mechanical Load Should Be Ik08 ( 5 Joule ) In Accordance With Iec 62262. The Meter Enclosure As Per Aproved Make In Mes Command List. The Manufacturer Of Panel Shall Submit A Copy Of His Asta Cpri Test Report In Polycarbonate Only Also Share Panel Assemble By Oem, Channel Partner Or Sister Concerned Assembly Will Not Accepted And Submit The Copy Of Asta Cpri Report Shall Have Mention Of Following Tests Performed And Passed Out Satisfactorily Temperature Rise, Dielectric Properties, Short Circuit Withstand Current – Rated Peak, Short Time Withstand Current And Rated Conditional Short Circuit Current, Effectiveness Of Protective Circuits And Submit The Copy Of Type Test Reports For Polycarbonate Thermoplastic Board Only.Test Reports Submitted Of Other Material Of Construction Like Ms, Ss Will Not Be Applicable. The Meter Box Should Passed Glow Wire Test 960Oc In Accordance With 60695-2-11 [ Flame Retardant And Self-Extinguishing ] . The Gasket Should Be Internally Embedded Made Of Polyurethane . Meter Enclosures Provided With Wall Mounting Povision & Enclosures Accessoriesas Per Ral 7035. Make- Hensel / Rittal / Emitter / Schneider / Abb. 13 M&L For Earthing Complete With Galvanized Steel Plate Elecrode Of Size 60Cm X 60Cm X 6.0Mm Thick Burried Directly In Ground Vertically To A Depth Not Less Than 2.5 Mtr Below The Ground Level With Top Edge Of Earth Plate At A Depth Not Less Than 1.5 Mtr Below Ground Level. Earth Plate Surrounded By 15Mm Thick Packed Alternative Layers Of Charcoal Dust And Comman Salt, Earth Lead Gi Wire Of 4Mm Dia ( 8 Swg ) By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanised Iron With Thimbles. The Other End Of Gi Earth Wire Is Connected To Main Switch Board And Protected By Light Grade Gi Pipe Of 15 Mm Bore. Provision Of 20Mm Bore Light Grade Gi Pipe For Watering Including Gi Funnel And Wire Mesh. Pipe Shallbe Provided Vertically Upto Top Level Of Earth Pit And Then Taken Horrizontally To The Earth Pit. Cement Concrete Chamber Of Pcc ( 1:3:6 ) Type C-2 Using 40 Mm Graded Stone Aggregate.The Chamber Shall Be Constructed One Metre Away From Edge Of Earth Pit. 50 Mm Thick Pre Cast Cover Of Cement Conrete ( 1:2:4 ) Type B-1 Using 20 Mm Graded Stone Aggregate And Ms Angle Iron 50 X 50 X 6Mm Frame Including Two Coats Of Painting Over A Red Oxide To Exposed Steel Surfaces. Excavation In Soft / Loose Soil, Returning Filling And Removal Of Surplus Soil To A Distance Of 50 Mm As Directed And Shown In Electrical Plate No- 3 Of Ssr Part-1 ( 2009 ) Complete All As Directed And Specified. 14 Excavation In Trenches In Soft / Loose Soil Not Exceeding 1.5 Metre Wide And Not Exceeding 1.5 Metre Deep And Not Exc 10 Sqm On Plan, For Laying Of Cable And Getting Out, Complete All As Directed And Specified. 15 M&L Dry And Clean Fine Sand For Cable Cushioningto Underground Cable Protection, Complete All As Directed And Specified. Note- Punned Down Thickness Shall Be Measured. 16 S&F Cover To Underground Cable With One Layer Of Bricks Using Sub Class ‘B’ Bricks ( Old Size ) Laid Flat Across The Cable Complete All As Directed And Specified. 17 Returning, Filling In, Earth Including Spreading, Leveling Watering And Well Ramming In Layers Each Not Exceeding 25Cm Thick Each Layer, Complete All As Directed And Specified. 18 Removal Of Surplus Soil To A Distance Not Exc. 50 Metre And Depositing Where Directed At A Level Not Exc. 1.5 Metre Above The Starting Point Complete All As Directed And Specified. 19 S&F Mild Steel Galvanised Pipe, Light Grade, 40 Mm Nominal Bore For Passing Of Cable, Fixed To Poles / Walls, Laid Under Floor / Road Crossings, Complete With And Including Clamps Socket & Elbow Etc Including Taking Down, Complete All As Directed And Specified. 20 Supply And Installation In Repairs, Commissioning And Testing Polycarbonate Asta Cpri Approved Oem Made Outdoor Main Lt Panel With Canopy ( Mini. Size 600 X 600 X 170 Mm ) . The Panel Shall Be Made Of Modular Polycarbonate Thermoplastic Enclosures Including Mccbs And Indicator Lamps Which Shall Be Uv Resistance In Accordance With Iec 61439-1, Clause 10.2.4: The Panel Shall Be Anti-Acid & Anti Corrosive. Degree Of Protection Against Mechanical Load Shall Be Ik08 ( 5 Joule ) In Accordance With Iec 62262. The Manufacturer Of Panel Shall Submit A Copy Of Asta Cpri Test Report In Polycarbonate Only Also Share Panel Assembled By Oem, Channel Partner Or Sister Concern Assembly Will Not Be Accepted. Degree Of Ingress Protection Ip 65 In Accordance With Iec 60529. The Gasket Shall Be Internally Embedded Made Of Polyurethane. The Panels Made By Aprroved Enclosures In Mes & They Shall Submit A Copy Of Type Test Report Of A Board Made Out Of Polycarbonate Thermoplastic Panel In Accordance With Iec 60439-1. The Cpri Report Shall Have Mention Of Following Tests Performed And Passed Out Satisfactorily - Temperature Rise, Dielectric Properties, Short Circuit Withstand Current – Rated Peak & Short Time Withstand Current And Rated Conditional Short Circuit Current, Effectiveness Of Protective Circuits. The Board Manufacturer Shall Submit The Copy Of Type Test Reports For Polycarbonate Thermoplastic Board Only. Test Reports Submitted Of Other Material Of Construction Like Ms, Ss Will Not Be Applicable. Each Board Shall Have Individual Routine Test Report Of The Manufacturer. The Panel Shall Pass Glow Wire Test 960 Degrees Centigrade In Accordance With 60695-2-11 [ Flame Retardant And Self-Extinguishing ] . Ms Angle Stand 450 Height From Gound.Make-Hensel / Rittal / Emitter / Schneider.Incomer ( A ) Mccb 100A Fp 25Ka Thermal & Magnetic Released With Earth Fault Protection With Spreader Links - 01 Nos. ( B ) Led Indicator R, Y, B - 01 Set ( C ) Copper Bus Tpn 150 Amp - 01 Setoutgoing ( A ) Mcb 63A Spn 10Ka 240V C Curve - 07 Nos

Key Value

Document Fees
INR 500 /-
EMD
INR 38800.0 /-
Tender Value
INR 19.40 Lakhs /-

BOQ Items

Name of Work: Spl Repair/ replacement of distribution board, sub main wiring and other connected items at ‘Q’ Zone under GE (East ) Ferozepur Cantt
Sl. No. Item Description
1Taking down carefully unserviceable main switches and distribution boards with fuses/ MCB"s (single phase or three phase) of any capacity complete all as directed and specified.
2Taking down carefully old unserviceable sub main wiring including meters and making good disturbed surfaces and matching with existing complete all as directed and specified.
3S&F Factory made three phase and neutral Sheet Steel made out of CRCA 1.2 mm thick, powder coated double door vertical distribution board 4 way, dust and vermin proof, fitted with two cover, one screwed cover for incoming and outgoing MCBs and the second for protection of MCBs fitted with colour bus bar of capacity 200 Amps, neutral link, earth bar and din rail suitable for use on 240/415V, 50Hz supply, VTPN DB, partly immersed in wall, including of MCCB 4 pole adjustable thermal & fixed magnetic type 100 Amps, 50Hz, 415 Volts with rupturing capacity 16 KA and making good distrubbed surfaces with matching colour, complete all as specified.
4S&F Factory made single phase and neutral Sheet Steel made out of CRCA 1.2 mm thick, powder coated double door vertical distribution board 8 way, dust and vermin proof, fitted with two cover, one screwed cover for incoming and outgoing MCBs and the second for protection of MCBs fitted with colour bus bar of capacity 200 Amps, neutral link, earth bar and din rail. suitable for use on 240V, 50Hz supply, partly immersed in wall and making good distrubbed surfaces with matching colour, complete all as directed and specified.
5S&F MCB SPN, 40A - 63Amps, 240 volts, "C" series, 10KA duly ISI marked, in MCB DB, complete with connection testing and commissioning complete all as directed and specified.
6S&F MCB SP, 6A-32 Amps, 240 volts, "B" series, 10KA duly ISI marked, in the MCB DB, complete with connection testing and commissioning complete all as directed and specified.
7M&L for Sub main wiring with two single core 2x6 sqmm FRLS insulated and unsheathed stranded copper conductoralongwith earth wire 6.0 sqmm FRLS drawn in and including rigid conduit connected to main board complete all as specified and directed (Note: Two runs cable and one number earth wire and suitable conduit shall measured together as unit length).
8M&L for disconnecting electric meter of any cap and refixing same after rewiring, in meter box including connection FRLS complete all as directed and specified.
9M&L forEarth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4 mm dia galvanised iron or steel wire complete all as directed and specified.
10S&F XLPE insulated, armoured, 1100 volts grade, heavy duty cable of size 25 Sqmm nominal cross section, 4 core, aluminium conductor, served with inner sheathing of galvanized steel wire or tape and over-all PVC sheathed in service connections, laid in trenches, duct, through pipe, in floor, on pole including jointing with double compression copper stain less steel gland at DBs and testing, complete all as directed and specified. ( Note:- Excavation & earth work, brick protection and sand cushionshall bemeasured and paid separately)
11S&F XLPE insulated, armoured,1100 volts grade, heavy duty cable of size 10 Sqmm nominal cross section, 2 core, Circular, PVC insulated aluminium conductor, served with inner sheathing of galvanized steel wire or tape and over-all PVC sheathed in service connections, laid in trenches, duct, through pipe, in floor, on pole including jointing and testing, complete all as directed and specified. ( Note:- Excavation & earth work, brick protection and sand cushionshall bemeasured and paid separately)
12S & F in repairs, installation, commissioning and testing Polycarbonate ASTA CPRI approved OEM made Meter Enclosure. The Meter Box shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The Meter Box with the Provision for 6 Nos Single Phase Meters with Provided Bakelite sheet at the bottom of meters ( Size 600 x 600 x 170mm ). Meter Box type Wall Mounted type on Mounting Structure RAL 7016, anti-acid, anti corrosive & Fully Transparent Door for meter Vision with four side Screw Drive operated locking . Degree of protection IP 65 IN ACCORDANCE WITH IEC 60529 and against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The Meter Enclosure as Per Aproved make in MES Command List. The manufacturer of panel shall submit a copy of his ASTA CPRI TEST REPORT IN POLYCARBONATE only also share panel assemble by OEM, channel partner or sister concerned assembly will not accepted and submit the copy of ASTA CPRI report shall have mention of following tests performed and passed out satisfactorily Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak, short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits and submit the copy of type test reports for Polycarbonate Thermoplastic Board only.Test Reports submitted of other material of construction like MS, SS will not be applicable. The Meter Box should passed glow wire test 960oC in accordance with 60695-2-11 [flame retardant and self-extinguishing]. The gasket should be internally embedded made of polyurethane . Meter Enclosures provided with wall mounting povision & Enclosures Accessoriesas per RAL 7035. Make- Hensel/ Rittal/ Emitter/ Schneider/ ABB.
13M&L for Earthing complete with galvanized steel plate elecrode of size 60cm x 60cm x 6.0mm thick burried directly in ground vertically to a depth not less than 2.5 mtr below the ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level. Earth plate surrounded by 15mm thick packed alternative layers of charcoal dust and comman salt, earth lead GI wire of 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanised iron with thimbles. The other end of GI earth wire is connected to main switch board and protected by light grade GI pipe of 15 mm bore. Provision of 20mm bore light grade GI pipe for watering including GI funnel and wire mesh. Pipe shallbe provided vertically upto top level of earth pit and then taken horrizontally to the earth pit. Cement concrete chamber of PCC (1:3:6) type C-2 using 40 mm graded stone aggregate.The chamber shall be constructed one metre away from edge of earth pit. 50 mm thick pre cast cover of cement conrete (1:2:4) type B-1 using 20 mm graded stone aggregate and MS angle iron 50 x 50 x 6mm frame including two coats of painting over a red oxide to exposed steel surfaces. Excavation in soft/ loose soil, returning filling and removal of surplus soil to a distance of 50 mm as directed and shown in Electrical Plate No- 3 of SSR Part-1 (2009) complete all as directed and specified.
14Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep and not exc 10 Sqm on plan, for laying of cable and getting out,complete all as directed and specified.
15M&L Dry and clean fine sand for cable cushioningto underground cable protection, complete all as directed and specified. Note- Punned down thickness shall be measured.
16S&F Cover to underground cable with one layer of bricks using sub class ‘B’ bricks (old size) laid flat across the cable complete all as directed and specified.
17Returning, filling in, earth including spreading, leveling watering and well ramming in layers each not exceeding 25cm thick each layer,complete all as directed and specified.
18Removal of surplus soil to a distance not exc. 50 metre and depositing where directed at a level not exc. 1.5 metre above the starting point complete all as directed and specified.
19S&F Mild steel galvanised pipe, light grade, 40 mm nominal bore for passing of cable, fixed to poles/walls, laid under floor/road crossings, complete with and including clamps socket & elbow etc including taking down, complete all as directed and specified.
20Supply and installation in repairs, commissioning and testing Polycarbonate ASTA CPRI approved OEM made Outdoor main LT Panel with Canopy ( Mini. Size 600 x 600 x 170 mm ) . The panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES including MCCBs and indicator lamps which shall be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel shall be anti-acid & anti corrosive. Degree of protection against mechanical load shall be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of ASTA CPRI TEST REPORT IN POLYCARBONATE only also share panel assembled by OEM, channel partner or sister concern assembly will not be accepted. DEGREE OF INGRESS PROTECTION IP 65 IN ACCORDANCE WITH IEC 60529. The gasket shall be internally embedded made of polyurethane. The Panels made by aprroved enclosures in MES & they shall submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of following tests performed and passed out satisfactorily - Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits. The board manufacturer shall submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer. The panel shall pass glow wire test 960 degrees Centigrade in accordance with 60695-2-11 [flame retardant and self-extinguishing]. MS Angle Stand 450 Height from Gound.Make-Hensel/Rittal/Emitter/Schneider. INCOMER (a) MCCB 100A FP 25KA Thermal & Magnetic Released with Earth Fault Protection with Spreader Links - 01 Nos. (b) LED Indicator R, Y, B - 01 Set (c) Copper Bus TPN 150 Amp - 01 Set OUTGOING (a) MCB 63A SPN 10KA 240V "C" Curve - 07 Nos