Delhi University has published Tender For Misc. Work, Geetanajli Hostel, Aravali Hostel, Canteen Building, Department Of Microbiology, B.K. Bachhawat Block, Arts Faculty, Director Office, Green House, Health Centre, Saramati Hostel, Health Centre, Biotech Building, Sdc. Submission Date for this Tender is 08-11-2022. Building Work Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
2 | 12 mm cement plaster 1:2 (1 cement : 2 stone dust). |
3 | 15 mm cement plaster 1:2 (1 cement : 2 stone dust) on the rough side of single or half brick wall. |
4 | Distempering with oil bound washable distemper of approved brandand manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer |
5 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
6 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin- charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. |
7 | Dismantling old damaged plaster and racking out joints |
8 | Cleaning and disposal of old plaster and concrete malba etc. |
9 | JK Wall Putty |
10 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe32 mm dia |
11 | Pressure motor jetting i/c p/fixing charges. |
12 | Repairing door pillar i/c nut bolts carpenter etc. complete job |
13 | Repairing the broken G.I. pipe line i/c new fitting, pipe, 20 mm MT/ FT, socket, salvent, plumber and taking out old leakage pipe 20 mm, saramati hostel roof. |
14 | Open the blocked vertical drainage C.I. pipe line and removal of cloth plastic material etc. |
15 | P/F brass 25 mm gate valve |
16 | Repair the aluminium door i/c cutting, fitting, but bolt, carpenter etc. |
17 | Taking out the old leakage PVC 4" pipe and cleaning disposal of malba |
18 | Dismantling Old RCC damaged flooring and plaster i/c cleaning disposal of malba complete Job |
19 | Repair aluminiun door i/c cutting fitting etc. at canteen Building main door |
20 | Break the closed 3" G.I. pipe and then open line and refilling the door tee joints |
21 | Taking out the block pipe 3" and fixing with new PVC pipe 4" filling the joints i/c P/H |
22 | Repair the damaged floor i/c sand, cement concrete mason labour |
23 | Refilling W/c jointswith white cement |
24 | Replacement of not working in godrej almirah locks and fixing with new main lock cutting fitting carpenter helper etc. in the Examination branch |
25 | Repair MS collapsible sliding door i/c welder, helper etc. |
26 | Greesing the all MS collapsible sliding door i/c bobil oil, grese and labour at Examination Branch |
27 | Replacement of leakage G.I. pipe and fixing with new CPVC pipe 1" gate valve MT , Ft, P/H etc. |
28 | Repair leakage PVC 32 mm A/c pipe in site the lab i/c M-seal plumber etc. |
29 | Excavation and levelling work. |
30 | Make new water connection at Director Office back side portion i/c G.I. fittings, 2 ft by 3" 2 pic.,nipple, socket, P/H etc. |
31 | P/F J" CPVC union |
32 | Repair leakage G.I. 1" pipe line at type I block I Q. No. 3 Back side portion |
33 | P/F foora 3 turh inter lock with heavy duty ISI etc. |
34 | Repair multiply door lock i/c carpenter helper charges |
35 | Make new water cooler frame with 5 mm by 32 mm steel angle i/c welder helper, cutting fitting etc. complete job at Aravali Hostel mass side |
36 | Refixing water cooler and water cooler frame at Aravali Hostel |
37 | Exacavation as levelling work |
38 | Taking out the all leakage 32 mm and 25 nmm pipe |
39 | P/F CPVC union 25 mm |
40 | Pipe sporting piller |
41 | P/F 25 mm to 32 mm brass ISI MT and FT |
42 | Keeping old broken pipe in Engineer Office Store |
43 | Dismantling old damage plaster and raking out joints |
44 | Cleaning and disposal of old plaster and concrete malba etc. |
45 | Picking up the broken pipe on the roof of the canteen building and placing it in the store of the Engineering Office |
46 | Fixing the loose white stone on upper side the parapet wall i/c cement, sand, cutting refixing mason, labour etc. |
47 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall |
48 | 20 mm nominal outer dia. Pipes |
49 | 25 mm nominal outer dia. Pipes |
50 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal outer dia Pipes |
51 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore |
52 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore |
53 | Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 15 mm nominal bore with 45 cm length |
54 | Repair flush tank |
55 | Make new hydrant i/c cement sand |
56 | Taking out the old leakage G.I. line |
57 | Make new pipe sporting pillar i/c brick, cement sand, mason etc. |
58 | Repair broken pipe line i/c union 20 mm pipe etc. |
59 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 100 to 250 mm diameter |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail