Tender For Maintenance And Repair Of Main Water Supply Pipe Lines And Sanitary Fittings In Residential And Non Residential Buildings Of 1X660 Mw, Ptep, Panki, Kanpur
Tender Overview
Project Description
Tender For Maintenance And Repair Of Main Water Supply Pipe Lines And Sanitary Fittings In Residential And Non Residential Buildings Of 1X660 Mw, Ptep, Panki, Kanpur
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 10-Nov-2022 | DATE EXTENSION | Date | 24-Nov-2022 |
BOQ
| Sl. No. | Item Description |
| 1 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 15 mm dia. nominal bore |
| 2 | Same as Item No. 1 but for 20 mm dia. nominal bore |
| 3 | Same as Item No. 1 but for25 mm dia. nominal bore |
| 4 | Same as Item No. 1 but for40 mm dia. nominal bore |
| 5 | Same as Item No. 1 but for50 mm dia. nominal bore |
| 6 | Renewal of clamp connection including cleaning, chocking of silt etc. |
| 7 | Providing and fixing 15 mm dia brass ferrule/ New Clamp Connection including supply of all material, labour, T&P required for proper completion of work. |
| 8 | Making water connection of G.I pipe line with G.I. mains by P/F M. S. clamp, G. I. socket & rubber packing as per required size including welding and drilling hole in the pipe including supply of all material labours and T&P etc, required for proper complection of work |
| 9 | S/F of 15 mm dia C.I. bib cock including replacing of old bib cock complete. |
| 10 | S/F of 15 mm dia plastic bib cock including replacing of old bib cock complete. |
| 11 | Providing and fixing 15 dia brass bib cock/ stop cock of approved quality including replacing of old bib cock. |
| 12 | P/F 15 mm dia C.P pillar cock(400 gms) of approved make including cost of all material, cartage, labour, T&P etc. required for proper completion of work. |
| 13 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore. |
| 14 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore : 15mm nominal bore. |
| 15 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore. |
| 16 | S/F P.V.C float for float value 15 mm |
| 17 | Repairing including replacement of damaged part, fiber washer, spindle rod and face etc. CP pillar cock |
| 18 | Providing & replacing Spendle /pillar head of CP piller cock. |
| 19 | Repairing of low head/high head flushing cisterm including removal and re-fixing if required as per direction of E/I. |
| 20 | Replacing plastic handle of PVC Cistern of suitable match as required as per direction of E/I. |
| 21 | S/F of 110 mm outer dia P.V.C .pipe (4Kg/sq.cm) including necessary specials like bend shoes, collars, clamps etc. jointing solution cutting making good the wall including supply of necessary M.S. clamp 2.5cmx3mm fixed to walls with and including supply of 15 cm 6mm dia nails also including removal of old damaged pipe if required . |
| 22 | Same as above item but 90 mm outer dia. |
| 23 | S/F of 110 mm outer dia P.V.C .pipe (6Kg/sq.cm) including necessary specials like bend shoes, collars, clamps etc.jointing solution cutting making good the wall including supply of necessary M.S.clamp 2.5cmx3mm fixed to walls with and including supply of 15 cm 6mm dia nails also including removal of old damaged pipe if required |
| 24 | Same as above itembut 90 mm outer dia. |
| 25 | Removal and refixing of down pipes for removing chocking of pipes for size 50 to 150mm coming from roofs. lavatories, kitchen, bathroom etc with all labour, T&P etc. required for proper completion as per direction of E/I |
| 26 | Taking out unwanted weeds/ trees from the wall/ roof of residence and disposal of the same outside the UPRVUNL area. |
| 27 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: Coupler 110 mm |
| 28 | Same as Item No.27 but forSingle tee with door 110x110x110 mm |
| 29 | Same as Item No. 27 but forBend 87.5° - 110 mm bend |
| 30 | Same as Item No. 27 but forShoe (Plain) 110 mm Shoe |
| 31 | P/F of Ist quality white glazed earthen warewash hand basin ISI marked size 550x400mm (Hindware or equilent make) excluding fitting including cutting and making good the wall and floor with cement, coarse sand required for proper completion of work as per direction of E/I |
| 32 | Same as above Item but for size 450x300 mm |
| 33 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required Kitchen sink without drain board 610x460 mm bowl depth 200 mm |
| 34 | P/F 100 mm dia C.P grating over Nahani trap or drain holes including cost of all materials, labour and T&P etc required for proper completion of the work. |
| 35 | P/F M.S/C.I bracket of standards size as required for sink and wash basin cistern etc. including removal of old damaged bracket if required and cutting and making good wall etc with cement motor.(NSI) (old Agr. Rate) |
| 36 | P/F C.P. waste jali with check nut complete including cost of all labour, material and T&P etc. required for proper completion of work . |
| 37 | Supply and replacing 32 mm dia P.V.C. waste pipe for wash basin / sink including cost of all labour, material and T&P etc. required for proper completion of work |
| 38 | P/F in position 32 mm dia P.V.C flush pipe for low levelPVC flushing cisternincluding cost of all labour, material and T&P etc. required for proper completion of work . |
| 39 | P/F 32 mm dia P.V.C. rigid flush bend required in jointing works as per direction of E/I. (old Agr. Rate) |
| 40 | P/F P.V.C. connection 300x15 mm pipe with two nos brass unions including supply of all material, labour and T&P etc. required for proper completion of work. |
| 41 | P/F600x450 mm beveled edge mirror of superior glass (of approved quality )complete with 6mm thick hard board ground fixed to wodden cleats with C.P. brass screws and washers complete |
| 42 | P/F 5 Liter PVC flushing cistern I.S.I marked with fitting complete (Automatic flushing System).\ |
| 43 | P/F full way G.M gate valve 25 mm dia with wheel ISI mark heavy quality including supply of all material, labour and T&P required for proper completion of work. |
| 44 | Same as Item no.43 but 15 mm dia |
| 45 | Same as Item no.43 but 20 mm dia |
| 46 | S/F of syntax or equivalent make water storage tank quality including supply of all material labour and T&P required for proper completion of work. |
| 47 | Cleaning of small size water storage tank upto 1000 ltrs. capacity including rubbing, scarping rust etc. and dis-infacting with all labour T&P etc. required including disposal of refuse as per direction of E/I |
| 48 | P/F D-clamp joints in50mm dia pipe between water mains all earth work and cutting / threading of pipe bailing out disposal of refuse as per direction of E/I. |
| 49 | P/F of Ist quality white glazed earthen ware angular urinal basin for corner size 430x370x340 mm or squatting type 450x350 as per approved sample (Hindware or equivalent make) including CP Brass union coupling, PVC waste pipe including supply of all material, labours and T&P etc, required for proper completion of work. |
| 50 | Attending leakage from WC seat of upper floor including removing old damaged WC pan / trap dismantling floor excavating and refilling coarse clunker as requiredfor proper completion of work (any fiting during executing required shall be paid extra) but including cutting making good the walls,floor etc. including uprooting the same vegetation if requires as per direction of E/I (old Agr. Rate) |
| 51 | Dismantling W.C. pan of all sizes Indian type, Orissa pan or European type including dismantling of floor or wall as required and also including disposal of refuse including cost of all labor and T & P etc required for proper completion of the work.(SOR-2014-15.08) |
| 52 | Attending leakage of Nahani /floor trap of upper storey including cutting and making good walls and floor and refixing of trap etc. complete (old Agr. Rate) |
| 53 | S/F PVC Nahani trap of heavy quality over minimum 75 mm thick cement concrete in proportion of 1:2:4 including cost of cement concrete, all material, labour and T&P etc. required for proper completion of the work. |
| 54 | P/FOrissa pattern W.C. pan of size 580x440 mm |
| 55 | P/F white vitreous china pedestal type (European type) W.C. pan |
| 56 | P/F White solid plastic seat with lid for European W.C. Pan. |
| 57 | Providing and fixing white vitreous china water closet squatting pan (Indian type) : Long pattern W.C. pan of size 580 mm. |
| 58 | P/F white glazed ‘P’ or ‘S’ trap for W. C. pan over minimum 75 mm thick cement concrete in proportion of 1:6:12 including cost of cement concrete and all materials, labours cartage T&P etc required for proper completion of work . |
| 59 | P/F pair of white glazed foot rests of standard pattern for Indian type W.C pan including supply of all material, labours and T&P etc. required for proper completion of work |
| 60 | Providingandfixing 25 mm nominal bore gunmetalnon-returnvalveofapprovedquality (screwed end) : |
| 61 | Providing , laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1(1 cement :1 fine sand ) including testing of joints etc. complete ;100 mm diameter |
| 62 | Same as the above item but 150mm diameter |
| 63 | Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50m lead and disposal of unserviceable materials into munisipal dumps :100 mm diameter |
| 64 | Same as above Item but 150 mm diameter |
| 65 | Providing and fixing soil, waste and vent pipes : 100 mm dia Sand cast iron S&S pipe as per IS: 1729. |
| 66 | Same as above item but 75 mm dia |
| 67 | Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes 100 mm dia pipe |
| 68 | Same as above item but for 75 mm dia pipe |
| 69 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter: 100 mm |
| 70 | Same as above item but for 75 mm |
| 71 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. :For 100mm dia. Pipe |
| 72 | Same as above item but for75 mm dia. Pipe |
| 73 | Makingconnection of drain or sewer with existingmanhole, septic tank including breaking into and makinggood the walls, floors with cement concrete 1:2:4 mix etc. Complete: For pipes 100 to 250 mm diameter. |
| 74 | Providing and fixing G.I. union in existing G.I. pipe line, cutting and threading the pipe and amking long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever reaquired. : 15 mm dia pipe |
| 75 | Same as item no. 74 but for20 mm dia pipe |
| 76 | Same as item no. 74 but for 25mm dia pipe |
| 77 | Same as item no. 74 but for 40mm dia pipe |
| 78 | Same as item no. 74 but for 50 mm dia pipe |
| 79 | Providing and fixing 750mmx20mm size C.P. brass Towel Rail of approved quality (wt 275gmsincluding brackets) with a pair of C.P. brass brackets fixed with PVC cleats & brass screws and washers including cutting and making good the wall plaster including cost of all materials, labour and T&P etc. required for proper completion of work. |
| 80 | Providing and fixing C.P. Brass Soap Disk with brackets fixed to wooden cleats with brass screws including supply of all materials, labour, T&P etc required for proper completion of work. |
| 81 | Supply and fixing C.P. brass shower heavy quality 100mm dia (Weight not less than 225gms) including cost of C.P. nipple 15mm dia including supply of all materials, labour, T&P etc required for proper completion of work. |
| 82 | 2.5 cm thick 1:2:4 plain cement concrete floor with cement approved coarse sand and 2 cm graded approved stone ballast laid in panels finished with 3 mm floating coat of neat cement or cement and marble dust in to ratio of 5:1 as specified over and removing dry overlapping moratr at joint of panels if any and giving them a uniform finish including supply of all material and labours and T&P etc. required for proper completion of work |
| 83 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply. including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge Concealed work, including cutting chases and making good the walls etc DSR 18.8.1 15 mm nominal outer dia Pipes |
| 84 | Same as item no. 83 but for DSR 18.8.2 20 mm nominal outer dia Pipes |
| 85 | Same as item no. 83 but for DSR 18.8.2 20 mm nominal outer dia PipesDSR 18.8.3 25 mm nominal outer dia Pipes |
| 86 | Same as item no. 83 but for DSR 18.8.2 20 mm nominal outer dia PipesDSR 18.8.3 30 mm nominal outer dia Pipes |
| 87 | DSR 18.53A Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge |
| 88 | Providing and fixing 8 mm dia C.P./ S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type WC of quality and make as approved by Engineering in charge |
| 89 | 17.81 Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattem including integrated white vitreous china cistem of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistem fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge(JAGUAR/HINDWARE/PARRYWARE) |
| 90 | Providing and fixing 15 mm heavy body brass C.P Flexible hand faucet (Plumber/Cera/Jaquar) make. |
| 91 | Dismantling G.I./C.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as perdirection of Engineer-in-charge :G.I. 15 mmto 40mm dia pipe(DSR2016-15.44.1) |
| 92 | Same as item no. 91 but for DSR 18.8.2 20 mm nominal outer dia PipesG.I. Above 40mm dia pipe (DSR2016-15.44.2) |
| 93 | Same as item no. 91 but forC.I. upto150mm dia pipe (DSR2016-15.45.1) |
| 94 | Same as item no. 91 but forC.I Above 150 mmto 300 dia pipe (DSR2016-15.45.2) |
| 95 | Fixing of old serviceable or new departmental G.I//C.I pipe including providing and fixing, G.I. fittings like socket, elbow, bend, union, Tee etc.of approved quality I.S.I mark with necessary pipe hook including cutting and making good the wall, floors etc. with necessary cartage of pipe up to site of work15 mm dia pipe |
| 96 | Same as item no. 95 but for20 mm dia pipe |
| 97 | Same as item no. 95 but for25mm dia pipe |
| 98 | Same as item no. 95 but for40mm dia pipe |
| 99 | Same as item no. 95 but for50 mm dia pipe |
| 100 | Same as item no. 95 but for65 mm dia pipe(NSI) |
| 101 | Same as item no. 95 but for80mm dia pipe |
| 102 | Same as item no. 95 but for100mm dia pipe |
| 103 | Same as item no. 95 but for150mm dia pipe |
| 104 | Same as item no. 95 but for200mm dia pipe |
| 105 | Same as item no. 95 but for250mm dia pipe(NSI) |
| 106 | Providing and fixing G.I. pipes complete with G.I. fittingsand c lamps, i/c cutting and making good the walls etc. 15 mm dia nominal bore Internal work - Exposed on wall (DSR2016-18.10.1) |
| 107 | Same as item no. 106 but for20 mm dia nominal bore Internal work - Exposed on wall (DSR2016-18.10.2) |
| 108 | Same as item no. 106 but for25 mm dia nominal bore Internal work - Exposed on wall (DSR2016-18.10.3) |
| 109 | Same as item no. 106 but for40 mm dia nominal bore Internal work - Exposed on wall (DSR2016-18.10.5) |
| 110 | Same as item no. 106 but for50 mm dia nominal bore Internal work - Exposed on wall (DSR2016-18.10.6) |
| 111 | Same as item no. 106 but for65 mm dia nominal bore work (SOR2014-24.07) |
| 112 | Same as item no. 106 but for80 mm dia nominal bore Internal work (SOR2014-24.08) |
| 113 | Same as item no. 106 but for100 mm dia nominal bore Internal work (SOR2014-24.09) |
| 114 | Suppling and laying cast iron spun pipe of approved quality including cutting of pipe where necessary and including excavation of trenches for laying the pipe line of approved size (600mmx900mm) and including its back filling after testing the pipe line. watering, ramming etc. complete including disposal of surplus earth from the sides upto 100 meter as per direction of E/I as required for proper completion of work80mm dia |
| 115 | Same as item no. 114 but for100mm dia |
| 116 | Same as item no. 114 but for150mm dia |
| 117 | Same as item no. 114 but for200mm dia |
| 118 | Same as item no. 114 but for250mm dia(NSI) |
| 119 | Providing and fixing 15 mm dia brass ferrule/ New Clamp Connection including supply of all material, labour, T&P required for proper completion of work.(Agr No : 84/PTPS/CWCD/ECMD-II/T-137/2012 +11%) |
| 120 | Renewal of clamp connection including cleaning, chocking of silt etc.(Agr.no.-80/PTPS/CWCD/ECMD-II/2012+12%) |
| 121 | P/F full way G.M gate valve with wheel ISI mark heavy quality including supply of all material, labour and T&P required for proper completion of work.15 mm dia (SOR2011-24.35A) |
| 122 | Same as item no. 121 but for20 mm dia (SOR2011-24.35B) |
| 123 | Same as item no. 121 but for25 mm dia (SOR2011-24.32) |
| 124 | Same as item no. 121 but for40 mm dia (SOR2011-24.34) |
| 125 | Same as item no. 121 but for50 mm dia (SOR2011-24.35) |
| 126 | P/F C.I sluice valve I.S.I marked class-1’MEC’ as per ISS : 780 & ISS2906 or S.R.Iother approved make complete with rubber, ring, packing bolt, nut, glands cord etc, including excavation and refilling the trenches bailing water removal of old unserviceable valve and Its cartage up to deptt store. For 80 mm dia pipe |
| 127 | Same as item no. 126 but For 100 mm dia pipe |
| 128 | Same as item no. 126 but For 150 mm dia pipe |
| 129 | Same as item no. 126 but For 200 mm dia pipe |
| 130 | Same as item no. 126 but For 250 mm dia pipe(NSI) |
| 131 | Same as item No126 but gate valve/ Sluice valve is supplied by the department including all fittings like nut bolts, gaskets, packings as required for proper completion of Work as per direction of E/I.15 & 20 mm dia pipe |
| 132 | Same as item no. 131but for 25mm dia pipe |
| 133 | Same as item no. 131but for50 mm dia pipe |
| 134 | Same as item no. 131but for65mm dia pipe |
| 135 | Same as item no. 131but for80mm dia pipe |
| 136 | Same as item no. 131but for100mm dia pipe |
| 137 | Same as item no. 131but for150mm dia pipe |
| 138 | Same as item no. 131but for200 mm dia pipe(NSI) |
| 139 | Same as item no. 131but for250 mm dia pipe(NSI) |
| 140 | Same as above item butSluice valve Repairing including replacement of all damaged/ non workable fittings like cover, valve sheet,back seat piston nut bolts, gaskets, packings as required for proper completion of work as per direction of E/I. 80mm dia pipe |
| 141 | Same as item no. 140 but for100mm dia pipe |
| 142 | Same as item no. 140 but for150mm dia pipe |
| 143 | Same as item no. 140 but for200 mm dia pipe(NSI) |
| 144 | Same as item no. 140 but for250 mm dia pipe(NSI) |
| 145 | Fabrication of Brass spindle with nut of different size and replacement of the same with old one.For 50 mm dia pipe |
| 146 | Same as item no. 145 but For 65 mm dia pipe(NSI) |
| 147 | Same as item no. 145 but For 80 mm dia pipe |
| 148 | Same as item no. 145 but For 100 mm dia pipe |
| 149 | Same as item no. 145 but For 150 mm dia pipe |
| 150 | Same as item no. 145 but For 200 mm dia pipe(NSI) |
| 151 | Replacing leakage of lead joints in C.I.Water main including bailing out water excavation and refilling etc., complete as per direction of E/I.For 80 mm dia pipe |
| 152 | Same as item no. 151 but For 100 mm dia pipe |
| 153 | Same as item no. 151 butFor 150 mm dia pipe |
| 154 | Same as item no. 151 butFor 200 mm dia pipe |
| 155 | Same as item no. 151 butFor 250 mm dia pipe(NSI) |
| 156 | P/F D-clamp joints inbetween water mains all earth work and cutting / threading of pipe bailing out disposal of refuse as per direction of E/IFor 50 mm dia pipe |
| 157 | Same as item no. 156 but For 65 mm dia pipe(NSI) |
| 158 | Same as item no. 156 butFor 80 mm dia pipe |
| 159 | Same as item no. 156 butFor 100 mm dia pipe |
| 160 | Same as item no. 156 butFor 150 mm dia pipe |
| 161 | Same as item no. 156 butFor 200 mm dia pipe |
| 162 | Same as item no. 156 butFor 250 mm dia pipe(NSI) |
| 163 | Providing and laying S&S C.I. Standard specials suitable for mechanical jointing as per IS : 13382 : Up to 300 mm dia (DSR2014-18.67.1) |
| 164 | Providing and laying D.I. Specials of Class K - 12 suitable for mechanical jointing as per IS : 9523 : Up to 600 mm dia |
| 165 | Making water connection of G.I pipe line with G.I. mains by P/F M. S. clamp, G. I. socket & rubber packing as per required size including welding and drilling hole in the pipe including supply of all material labours and T&P etc., required for proper completion of work (SOR2011-24.42) |
| 166 | Providing & Replacement of non return valve(reflux valve) ISI Marked with necessary nut bolts, packingsetc in position including supply of all material, Labour & T&P complete job as per direction of E/I.For 50 mm dia pipe |
| 167 | Same as item no. 166 but For 65 mm dia pipe |
| 168 | Same as item no. 166 but For 80 mm dia pipe |
| 169 | Same as item no. 166 but For 100 mm dia pipe |
| 170 | Same as item no. 166 but For 150 mm dia pipe |
| 171 | Same as item no. 166 but For 200 mm dia pipe(NSI) |
| 172 | Same as item no. 166 but For 250 mm dia pipe(NSI) |
| 173 | Same asabove item but Non return valve Repairing including replacement of all damaged/ non workable fittings like cover, valve sheet, spindle, back seat piston\" nut bolts, gaskets, packings as required for proper completion of Work as per direction of E/I.For 50 mm dia pipe |
| 174 | Same as item no. 173 but For 65 mm dia pipe |
| 175 | Same as item no. 173 but For 80 mm dia pipe |
| 176 | Same as item no. 173 but For 100 mm dia pipe |
| 177 | Same as item no. 173 but For 150 mm dia pipe |
| 178 | Same as item no. 173 but For 200 mm dia pipe(NSI) |
| 179 | Same as item no. 173 but For 250 mm dia pipe(NSI) |
| 180 | Cleaning of Valve\"s Pits become non-operational due to filling of earth, silt or garbage removal and disposal form site upto a distance of 50 m as per direction of E/I including all material, labour & T&P etc. |
| 181 | To carry out various works like digging to trace the pipe & leakage, refilling, dismentling brickwork & floor of manhole, drain or pit & disposal of unserviceble material from site of work upto 50 m, contineous bailing out the water, cutting of pipes, Dismantling of pipes, fixing & removal of temporary drain pipes for drainage from pit, cleaning of existing pipe lines, opening & closing washout points etcwhich is not suspectible to measure by providing one labour for a period of 8 hours with necessary tools as per direction of E/I. (NSI) |
| 182 | Providing and fixing G.I. union in existing G.I. pipe line, cutting and threading the pipe and amking long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever reaquired.(DSR2016-18.47)15 mm dia pipe |
| 183 | Same as item no. 182 but for 20 mm dia pipe |
| 184 | Same as item no. 182 but for25mm dia pipe |
| 185 | Same as item no. 182 but for40mm dia pipe |
| 186 | Same as item no. 182 but for50 mm dia pipe |
| 187 | Same as item no. 182 but for65 mm dia pipe |
| 188 | Same as item no. 182 but for 80 mm dia pipe |
| 189 | Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc complete. (Tail peces, tapers etc if required will be paid separately. DSR2016-18.59) for 50 mm dia pipe |
| 190 | Same as item no. 189 but for 80mm dia pipe |
| 191 | Same as item no. 189 but for 100mm dia pipe |
| 192 | Providing and replacing the necessary nos of nut, bolts, packings of C.I. flanged for the fittings of old fittings and placing in postion as per direction of E/I. |
| 193 | Labour for cutting C.I. pipe with steel saw For 80 mm dia pipe |
| 194 | Same as item no. 193 but For 100 mm dia pipe |
| 195 | Same as item no. 193 but For 150 mm dia pipe |
| 196 | Same as item no. 193 but For 200 mm dia pipe |
| 197 | Same as item no. 193 but For 250 mm dia pipe |
| 198 | Cutting of MS Pipe 100 to 150mm dia and making thread at required pitch and length on lathe machine including cartage of pipe, including cost of all material, labour and T&P etc. required for proper completion of work. (SOR2014-22.83) |
| 199 | Making connection of drain or sewer with existing manhole septic tank including breaking into and making good the walls , floors with cement concrete 1:2:4 mix etc. comletefor pipes 100 to 250 mm dia.(Old Agreement) |
| 200 | Supply and fixing of 90 mm dia HDPE PN6 PE-63 grade pipe with all fiting connecting with existing line, including supply of pipe and excavation of trenches in ordinary soil, laying and refilling of trenches in layers duly campacted complete job. |
| 201 | Concrete with 4cm gauge brick ballast, coarse sand (F.M. 1.8 to 2.5) and cement in proportion of 12:6:1 in foundations and under floors including supply of all materials, labour and tools and plants etc. required for proper completion of work includingcement @ 2.25 Bags/m3 @Rs 280/Bags. (SOR2014-2015-5.25) |
| 202 | Cement concrete with 2 cm gauge approved hard stone ballast coarse sand and cement in proportion of 4:2:1 including supply of materials, labour, side shuttering if required and T&P etc. required for proper completion work. Including cement @ 6.00 bag/m3 @Rs 280/Bags.(SOR2014-5.03) |
| 203 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)(Based DSR2016-6.4.1) IncludingCement @ 1.90 Bags/cum @Rs 250/Bags. |
| 204 | 12 mm thick plaster on wall or ceiling cement mortar consist of 1 part cement & 4 parts of course sandIncluding cement @0.11 bag/M2 @Rs 280/Bags |
| 205 | Neat cement punning.(Based DSR2016-13.18) Including Cement @ 0.044 Bags/sqm @Rs 250/Bags. |
| 206 | RCC with cement approved coarse sand and 2 cm(3/4”) gaugegraded approved hard stone ballast in proportion 1:2:4 in lintels or bens and sunshade of door and window , shelves, slab , beam, raft foundation & footing , T- beam, column and walls etc. excluding supply of reinforcement and its bending but including its cutting fixing and binding the same with 24BWG GI binding wire and including necessary centering and smooth shuttering etc. required for proper completion of work including supply of all material, binding wire labour and T&P etc. including cement @ 6.00 bag/m3 @ Rs 280/ Bags |
| 207 | Mild steel or iron in plain work such as reinforced concrete or reinforced brick work (when not included in overall rates) wrought to required shape as necessaryincluding bending for proper completion of work but excluding supply of steel its wastage , bend, hooks and authorizes overlapping shall be measured. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender