Public Works Department-PWD has published Tender For Moei , Fans, Street Light/ Compound Light/ Security Light, Air-Conditioning, Pump Set, Dg Set At Fire Station Connaught Place, Fire Station Rakaab Ganj , Chanakya Puri, New Delhi. Submission Date for this Tender is 21-10-2022. Electrical Maintenance Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (a) Group A |
2 | (b) Group B |
3 | (c) Group C |
4 | Rewiring for light point/fan point/exhaust fan point/call bell point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 Sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel conduit including dismantling as required. (a) Group A |
5 | (b) Group B |
6 | (c) Group C |
7 | Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. (a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
8 | (b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
9 | (c) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
10 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (a) 3 x 1.5 sq. Mm |
11 | (b) 3 x 4 sq. Mm |
12 | (c) 3 x 6 sq. Mm |
13 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. (a) 25 mm |
14 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (a) 25 mm |
15 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
16 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. |
17 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. (a) 12 Module (200 mmX150 mm) |
18 | (b) 8 Module (125 mmX125 mm) |
19 | (c) 6 Module (200 mmX75 mm) |
20 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. (a) 1 or 2 Module |
21 | (b) 3 Module |
22 | (c) 6 Module |
23 | (d) 8 Module |
24 | (e) 12 Module |
25 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (a) 5/6 A switch |
26 | (b) 3 pin 5/6 A socket outlet |
27 | (c) 15/16 A switch |
28 | (d) 6 pin 15/16 A socket outlet |
29 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
30 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 12 way, Double door |
31 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) (a) 4 way (4 + 12), Double door |
32 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single Pole |
33 | (b) Single pole and neutral |
34 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 63 A |
35 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required |
36 | Supplying, installation, testing & commissioning of LED surface mounted 10 watt IP66 (waterproof) glarefree, pressure die cast aluminium housing with unbreakable polycarbonate diffuser bulk head fitting. Total system Lumen of 10W LED should be 550 or above in cool day light (5700K to 6500K), power factor>0.95, CRI>75. complete with all accessories as required i/c connections with 1.5 sq. mm PVC copper wire etc. as required. |
37 | Supplying & fixing of 10 watts wall mounted mirror LED luminaries (2 Ft.) working on 230Volts AC supply complete with connection & testing etc. as required. |
38 | Supplying, installation, testing & commissioning of 20 - 22 watt of 1200 mm long, 6500K energy efficient LED wall mounted batten light, extruded aluminum heat sink provided for efficient heat dissipation & integrated electronic driver, suitable to work 230 volt AC supply complete with connection etc. with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. The luminaries shall be submitted with LM-80 report with a life of 50000 hours @ L-70 and LED photo biological safety report conforming to IEC 62471 & LED source manufacturer and LM-79 report from NABL accredited lab. The LED chip should be of Cree, Nichia, Philips Lumiled, Osram, Edison etc. complete as required. |
39 | Supplying, installation, testing & commissioning of energy efficient recessed mounted type 34W to 36W full window glare free opal diffuser LED panel luminaries of size 2 x 2 feet (nominal size) including connections with 3 x 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required. The total system wattage not more than of 36W, LED lumen should be = 3960 system efficacy of = 110 lumen /watt colour temperature 4000K to 5700K, power factor>0.95, CRI (Ra)>80, THD <10%, with APFC driver having driver efficiency >85%, operating voltage 150-270 volts with minimum 2.5KV surge protection. The luminaries shall be submitted with LM-80 report with a life of 50000 Hours @ L-70 and LED photo biological safety report conforming to IEC 62471 & LED source manufacturer and LM-79 report from NABL accredited Lab. The LED chip should be of Cree, Nichia, Philips Lumiled, Osram, Edison. |
40 | Supplying, installation, testing & commissioning of energy efficient LED flood light luminaries of system wattages 100 watt complete with mounting brackets and accessories on the street light pole with help of tower wagon including connections complete as required. The LED luminaries should confirm the following technical specifications:- a) Type of LED: High power LEDs Nichia / Osram / Cree / Philips b) driver efficiency >85% c) System Efficacy >110lm/w d) color Index(CRI) Ra>70 e) Color Temperature (CCT) Cool white: 4000°K f) Input Voltage. 140-270V AC g) Frequency Range 50-60Hz h) Power Factor(PF) > 0.95 i) Surge protection = 10KV j) Total Harmonic Distortion(THD)< 10% k) Working Environment 0°C to 50°C;10%-90%RH l) Working lifetime: >50000 hrs. m) IP Rating :- IP66 n) Housing and finish:-epoxy powder coated die cast aluminum housing with elegantly designed heat sink for efficient thermal management and to excellent corrosion resistant, cable gland P49 is provided at cable entry cover & high quality toughned glass. |
41 | Supply, erection and commissioning of 4 mtr. high G.I. tubular pole ‘T’ washed, primered and painted, made in two sections bottom section of 1 mtr. having a dia of 114mm, thickness 4.0mm and top section of 3 mtr. having a dia of 60mm, thickness 3.2mm, fixed base plate at bottom profile of dimension 250mm x 180mm having thickness 16mm. The column shall also be provided with flush door at the bottom with proper strengthening to the cutout of the door opening. A junction/ looping box with 32 Amps. Heavy duty connector shall be built into the pole as per drawing attached. |
42 | Providing and laying in position 1:2:4 reinforced cement concrete foundation (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) made out of ready mix M-20 grade concrete of size 300mm (L) x 300 mm wide and 750 mm deep including excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm diameter-1000 mm long (approx)-8 Nos. and reinforcement ring of cold twisted bar of 8 mm diameter - 1700mm (approx)-6 Nos. with positioning of foundation bolt set, DWC Pipe for cable entry & exit etc. as required. For 4 Meter Pole |
43 | Supplying, installation, testing & commissioning of energy efficient 45 - 50 Watts LED post top lantern luminaries complete with accessories and suitable size clamp, nut bolt on the existing street light pole including connection with 1.5 sq mm FRLS PVC insulated copper conductor single core cable complete etc. as required. The LED fitting should confirm to the following technical specifications :- a. High power cool white LED with LM 80 test report. b. Life span of LED’s used should be greater then 50,000 hours out put. c. Colour rendering index(CRI)>80% d. Colour temperature of luminaries shall be 5700°K to 65000°K e. LM -79 test report of fittings f. Power factor>0.95 g. System Efficiency > 100 lumen/watt h. Operating voltage 140 Volts to 270 Volts i. Total Harmonic distortion <10% j. LED drive current 350 MA to 1000 MA k. LED drive efficiency>85% l. Housing :- Pressure Aluminium die Cast(thermal and impact resistance =IK-07 m. Ingress Protection - IP : 65 n. Safety :- As per IEC 62471 o. Cover :- It should be equipped with distoration free, clear heat resistant toughned, UV stablized glass / poly carbonate cover glare free p. Driver specifications :- 140-270 Volts universal Electronic driver with internal surge protection of minimum 5 KV q. Operating temperature-10°C to + 50°C r. Fitting size should not less than height 420mm x width 330mm x mounting dia 80mm [Dimension tolerance ± 5mm] |
44 | Supplying, installation, testing & commissioning of energy efficient following size ceiling fan including wiring the down rod of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable including providing and fixing phenolic laminated sheet cover on fan box etc. as required. (a) 1200 mm sweep size |
45 | (b) 600 mm sweep size |
46 | Supplying, installation, testing and commissioning of 400 mm sweep size wall mounted fan complete with inbuilt electronic regulator, blade, wire lead with moulded plug top etc. as required. |
47 | Supplying and fixing, fresh air fan of 200 - 250 mm sweep size suitable for 220 volts, 50 hz, A.C. supply, in the exisitng opening including, making the hole to suit the size of the above fan, making good the damages, connection, testing, commissioning etc as required. |
48 | Supplying, installation, testing & commissioning of vertical type following capacity storage/instant type electrical geysers, energy efficient having proper shell fixed with safety plug, thermostat & heating element On/Off indication & digital indication of temperature etc. complete with water pipe connection complete as required. (a) 25 Liters Capacity |
49 | (b) 3 Liters Capacity |
50 | Supplying, laying and fixing of following PVC insulated and PVC sheathed/ XLPE aluminum conductor armoured power cable of 1.1 KV grade etc as reqd. in the following manner: (a) 2 x 10 sq.mm on wall surface |
51 | (b) 4 x 16 sq.mm on wall surface |
52 | Credit of following electrical accessories etc. complete as reqd. (a) Assorted copper wire/cable |
53 | (b) Scrap iron/ conduit/ box |
54 | (c) Switch/socket (assorted size) |
55 | (d) Convention/LED luminaires(assorted size) |
56 | (e) Ceiling Fans assorted size |
57 | (f) Wall Fan (assorted size) |
58 | (g) Fresh Air Fan (assorted size) |
59 | (h) Assorted XLPE aluminium cable |