Department Of Electronics And Information Technology has published Tender For Design, Site Preparation, Supply, Installation, Testing, Commissioning, And Amc Services Of Basic Infrastructure For The Establishment Of A Data Center. Submission Date for this Tender is 15-12-2022. Tanks and Cylinders Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 02-Nov-2022 | 351-prebid-timing change | Other | 29-11-2022 |
2 | 29-Nov-2022 | 353-Submission Date Extended | Date | 15-12-2022 |
3 | 29-Nov-2022 | 353 Responses to Queries | Other | 15-12-2022 |
4 | 29-Nov-2022 | 353- Corrigendum - I | Technical Bid | 15-12-2022 |
5 | 13-Dec-2022 | 353 Responses to Query 1 | Other | 15-12-2022 |
Sl. No. | Item Description |
1 | Bidders to calculate the quantity as per Drawing Layout, SLD, P&ID & Site Visits w.r.t. - Supply and Installation of following items for complete DC solution at IUAC, New Delhi |
2 | Civil and allied works |
3 | UPS -2*500 KVA |
4 | Li-Ion Batteries for 2 X 500 KVA along with Battery Stand, Isolator, DC cabling etc. |
5 | UPS 2*150 KVA |
6 | Li-Ion Batteries for 2*150 KVA alongwith Battery Stand, Isolator, DC Cabling etc. |
7 | LVElectrical Components ,All LT Panels, DBs, Bus Bars, End feed units, Tap off boxes, PDU with k-4 rated Copper winding isolation dry type transfermer panel, ATS panels, Isolator Panels, Inrow Panels etc. |
8 | All LT Cabling –Power and Control, Earthing, Lighting Arrestors, Cable Trays, SS Cable Tray, Supports, Cable terminations, Glands and other accessories etc. |
9 | Internal and external Illumination System along with DBs |
10 | in Row unit (alongwith Air cooled condenser, copper piping and other accessories including containment, doors etc. |
11 | Adiabatic Dry Cooler along with associated accessories including Adiabatic water tank, expansion tank, chemical dozing, air separator etc |
12 | PHE, Thermal storage tank and associated accessories, |
13 | Dry cooler pumping alongwith associated accessories, VFD/FI Drive and Panel etc. |
14 | Pumping to primary of PHE alongwith associated accessories VFD/FI drive and Panel etc. |
15 | Pipes of all sizes ,Bends, valves, actuators, joints, end flanges and other hardware including accessories etc. |
16 | Instrumentation and Control for entire Cooling System |
17 | Fire Alarm system for Pota Cabin and Data Centre area including Detectors, panels, cabling and associated accessories etc. |
18 | Fire Suppression system for Data Centre area including Gas release panel, cylinder, Manifold, piping and associated accessories etc. |
19 | NOVEC Gas for Data centre area |
20 | Fire Suppression system for Pota Cabin area including Gas release panel, cylinder, NOVEC, Gas, Manifold, piping and associated accessories etc |
21 | NOVEC Gas for Basement area |
22 | CCTV system including camera, switch, NVR, Cables, monitors etc. |
23 | IBMS software includingsystem ( Computer ,Monitor) integration of third party devices, I/O modules, all control and communication cabling etc. |
24 | Other IBMS including Water leak detectors, Rodent Repellent, VesdaWater quality sensor system |
25 | Server Rack -45U along withDuel PDU ,cable manager and blanking plates , Branding, |
26 | Any other item, material, service charges etc.required to complete the entire solution as per Tender doc |
27 | Operation and Maintenance - Year-1 |
28 | Operation and Maintenance - Year-2 |
29 | Optional Items (These items will not be considered for computing L1. C-DAC/IUAC, New Delhi reserves the right towards placement of order for these items.) |
30 | Comprehensive Annual Maintenance Contract -Year-3 |
31 | Comprehensive Annual Maintenance Contract -Year-4 |
32 | Comprehensive Annual Maintenance Contract -Year-5 |
33 | Operation and Maintenance –Year-3 |
34 | Operation and Maintenance –Year-4 |
35 | Operation and Maintenance –Year-5 |