Tender For Digital Axle Counter Multi Section Type
Tender Overview
Project Description
Supply Of Digital Axle Counter Multi Section Typedigital Axle Counter Multi Section Type, Supply, Installation ( Indoor And Outdoor ) , Designing, Testing & Commissioning Of Digital Axle Counter, Multi Section Type, For Monitoring 36 Track Sections Equipped For 67 Dps Complete With Track Side Electronics With Housing Units, Track Clearance Relays, Reset Relays, Rail Contacts, Reset Boxes, Vital Relays, Detection Points, Deflector Plates, Lv Boxes, Evaluators Etc. As Per The Requirement At Site, As Per Rdso Specification No. Rdso / Spn / 176 / 2013 ( Version 3.0 ) Or Latest. Note: ( 1 ) This Includes Supply Of 10% Spare ( Rounded Off To Next Higher Number ) Of Each Item Of The Supplied Quantities Except Mother Board & Cabinet. ( 2 ) It Includes Supply Of Msdac Tool Kit - 1 Set Consisting Of ( Marking Zig, Digital Meter Fluke Model No. 289 Or Similar, Torque Wrench, Required Spanners, Screw Driver Set And Any Other Items Required In Tool Kit Suitable For Maintenance Of Supplied Msdac ) . ( 3 ) Digital Axle Counter, Multi Section Type Will Be Installed, Wired, Tested And Commissioned By Oems Engineer As Per Guidelines Issued By Rdso. The Pre-Commissioning Check List Issued By Rdso For Digital Axle Counter, Multi Section Type Will Be Prepared By Oem Engineer And Signed Jointly With Railway Site Engineer Before Commissioning Of Digital Axle Counter, Multi Section Type. Oem Will Submit Site Installation Certificate Mentioning That Digital Axle Counter, Multi Section Type Has Been Installed, Wired, Tested And Commissioned By Approved Vendor Of Rdso I.E., By Oem. ( 4 ) This Item Also Includes Installation Of Track Device ( Rail Contact ) Including Digging Of Trench, Track Crossing, Laying Of Double Walled Anti Rodent Corrugated Pipe From Track Device To Location Box / Dp And Making Its Terminations, Fixing Of Deflector Plates. ( Double Walled Anti Rodent Corrugated Pipe Made Up Of High-Density Polyethylene Of Suitable Diameter And All Other Accessories As Per Site Requirement To Be Supplied By The Firm ) . This Includes Provision Of Puff Seal In Hdpe Pipe With Contractors Own Material. This Also Includes Supply Of Hdpe Pipes For Laying Of Transmitter And Receiver Cables For Rail Contacts To Location Boxes / Dp &Installation Of Ejb / Track Side Electronics Inside The Track Side Housing ( This Housing / Location Boxes Shall Be Supplied And Installed On Foundation By The Contractor With His Own Material ) Including Supply Of Wires And Other Accessories. This Also Includes Painting And Writing On Detection Points And Ejb Housing. ( 5 ) 6-Quad Cable Coil Shall Be Provided To The Contractor Near To Dp Or In Location Box ( If Dp Is Installed Inside Location Box ) . ( 6 ) Contractor Has To Take Out The Cable Coil For Termination In Dp And Balance Cable Should Be Laid At A Depth Of Not Less Than 1M And Properly Protected Through Bricks. ( 7 ) Transmitter / Receiver Cables Laid From Dp To Rail Contacts Should Be Laid As Per Wcr Cable Laying Policy. ( 8 ) The Scope Includes Supply&Installation Of Maintenance Free Earth Including Other Accessories As Per Latest Rdso Specification Suitable For Msdac Detection Points. It Is Recommended That Contractor May Conduct Prior Site Survey For Assessment Of Various Parameters Of Materials To Be Supplied Like Length Of Tx / Rx Coil Among Others. Note: Supply To Be Made As Per Rdso Specification No. Rdso / Spn / 176 / 2013 ( Version 3.0 ) Or Latest. Rdso Item Id 3100268 Sub Item Id 3100268003
BOQ
| Sl. No. | Item Description |
| 1 | Digital Axle Counter Multi Section Type |
| 2 | Supply, installation (Indoor and Outdoor), Designing, testing & commissioning of Digital Axlecounter, MULTI section type, for monitoring 36 track sections equipped for 67 DPs complete with track sideelectronics with housing units, track clearance relays, reset relays, rail contacts, reset boxes, vital relays,detection points, deflector plates, LV Boxes, evaluators etc. as per the requirement at site, as per RDSOSpecification No. RDSO/SPN/176/2013 (version 3.0) or latest. NOTE: (1) This includes supply of 10% spare(rounded off to next higher number) of each item of the supplied quantities except mother board & cabinet. (2) Itincludes supply of MSDAC tool kit - 1 Set consisting of (Marking Zig, Digital meter Fluke Model No. 289 orsimilar, Torque Wrench, Required Spanners, Screw Driver Set and any other items required in Tool Kit suitablefor maintenance of supplied MSDAC). (3) Digital axle counter, Multi section type will be installed, wired, testedand commissioned by OEMs Engineer as per guidelines issued by RDSO. The Pre-commissioning check listissued by RDSO for Digital axle counter, Multi section type will be prepared by OEM engineer and signed jointlywith Railway site engineer before commissioning of Digital axle counter, Multi section type. OEM will submit siteinstallation certificate mentioning that Digital axle counter, Multi section type has been installed, wired, tested andcommissioned by approved vendor of RDSO i.e., by OEM. (4) This item also includes installation of track device(rail contact) including digging of trench, track crossing, laying of Double walled anti rodent corrugated pipe fromtrack device to location box/DP and making its terminations, fixing of Deflector plates. (Double walled anti rodentcorrugated pipe made up of high-density polyethylene of suitable diameter and all other accessories as per siterequirement to be supplied by the firm). This includes provision of Puff seal in HDPE Pipe with Contractors ownmaterial. This also includes supply of HDPE pipes for laying of transmitter and receiver cables for rail contacts tolocation boxes/ DP &installation of EJB/ Track side electronics inside the track side housing (Thishousing/location boxes shall be supplied and installed on foundation by the contractor with his own material)including supply of wires and other accessories. This also includes painting and writing on detection Points andEJB Housing. (5) 6-Quad cable coil shall be provided to the contractor near to DP or in location box (if DP isinstalled inside Location box). (6) Contractor has to take out the cable coil for termination in DP and balancecable should be laid at a depth of not less than 1m and properly protected through bricks. (7)Transmitter/Receiver cables laid from DP to rail contacts should be laid as per WCR cable laying policy. (8) Thescope includes supply&Installation of Maintenance Free Earth including other accessories as per latest RDSOspecification suitable for MSDAC Detection Points. It is recommended that Contractor may conduct prior sitesurvey for assessment of various parameters of materials to be supplied like length of TX/RX Coil among others.Note: Supply to be made as per RDSO Specification No. RDSO/SPN/176/2013 (Version 3.0) or latest. RDSOItem ID 3100268 Sub Item ID 3100268003 |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Completed