| 1 | Dismantling and removing 2.5cm thick artificial stone flooring including stacking the useful materials for reuse and removing the debreis within 50 M lead. |
| 2 | Dismantling and removing RCC columns, beams slab staircase, landing, lintels including stacking the useful materials for reuse and removing the debreis within 50 M lead. |
| 3 | Removing old lime or cement plaster from walls including racking out joints 12mm deep and removing the debries within 50mtr.lead etc all complete. |
| 4 | Removing old tarfelt from roof slab cleaning the surface, lowering and removing the debreis within 50 M lead. |
| 5 | 2.5cm. thick grading concrete (1:2:2) on roof slab. |
| 6 | Scrapping, painting, wall puty from walls etc all complete. |
| 7 | 2.5cm. A.S.flooring with cement concrete (1:2:4) including punning using 12mm size HGCB chips. |
| 8 | 1st Floor |
| 9 | Filling foundation and plinth with sand watered and rammed etc. |
| 10 | Providing cement concrete (1:4:8) with 4cm size hard granite metal. |
| 11 | RCC/CC of M-20 grade with 20mm and down grade black hgcb stone chips etc. |
| 12 | M.S.reinforcement for R.C.C. works including cutting, bending, binding and tying grills and placing in position etc. |
| 13 | Rigid and smooth centering and shuttering for R.C.C.works including false works and dismantling them after casting etc. |
| 14 | RCC foundation, plinth band and footing etc. |
| 15 | RCC floor and roof slab, landings & chajjas. |
| 16 | 12mm.thick cement plaster in cement mortar (1:4) for brick work etc. |
| 17 | 6mm.thick cement plaster in cement mortar(1:4) for R.C.C work for ceiling etc. |
| 18 | Providing and applying high performance touch applied APP based membrance sike wp or qualised or Asian paint shield 104P (APP. Modified bituminous membrance) of 4mm thickness with Non-woven Polyester mat Rainforcement of 160gsm prefabricated & self-finished five layered design super imposed with 20 microne thermo fusibile film, by fist applying Bituminious primer, confirming to IS-3384 @ 0.325 Kg/Sqm and allowing it to dry & then touching of the membrance with the helf of LPC / Butane gas touch keeping oerlapping of 4\"\" at the end fusing of all joint by gas toching including cost etc. (P.W.D. approved rate) |
| 19 | Distempering two coats with priming any approved shade etc. |
| 20 | Ground Floor |
| 21 | 1st Floor |
| 22 | Wall painting Two coats with weather coat paint of approved shade etc. |
| 23 | Painting two coats with approved paint in new or old wood/iron work over a coat of primer etc. |