}

Tender For City Beautifiaction Works At Sagwara - Rebid, sagwara-Rajasthan

Rajasthan Urban Infrastructure Development Project-RUIDP has published Tender For City Beautifiaction Works At Sagwara - Rebid. Submission Date for this Tender is 16-11-2022. Civil Work Tenders in sagwara Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

34337286
Corrigendum : Tender For City Beautifiaction Works At Sagwara - Rebid
Open Tender
Indian
Rajasthan
sagwara
16-11-2022

Tender Details

Tender For City Beautification Works At Sagwara- Rebid

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 21-Oct-2022 clarification to the bidders queries Technical Bid 16-11-2022

Key Value

Document Fees
INR 10000 /-
EMD
INR 2100000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: City Beautification works at Sagwara- Rebid
Sl. No. Item Description
1Part A- Civil Work
2Construction of embankment with approved material obtained from borrow pit with all lifts and leads, transporting to site, spreading, grading to required slope and compacting by vibratory roller 8-10 tonne to meet requirement of table 300-2 including cost of compensation for earth taken from private land complete as per MoRT&H specification clause 305. (Lead taken upto 5 km)
3Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level : 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size). (As per design mix) (electric pole, rcc rtaining wall, fauntain)
4Centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete.
5Reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars.
6Clearing and grubbing road land including up rooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to a lead of 50 metres from road boundary including removal and disposal of top organic soil not exceeding 150 mm in thickness as directed by Engineer. In area of light jungle
7Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level. In all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc. Depth upto 1.5 m
8Providing laying, spreading and compacting stone aggregates of specific sizes as per Table 400-7 to Water Bound Macadam specification including spreading in uniform thickness; hand packing, rolling with power roller 8-10 tonnes, in stages to proper grade and camber, applying and brooming requisite type of screening (Table 400-8) binding materials to fill up the interstices of coarse aggregates, watering (with water browser) and compacting to required density, making necessary earthen bund to protect edges as per clause 404 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion complete.Hand broken - Grade-II (63-45mm)
9Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : 1:3:6 (1 Cement : 3 fine/ coarse sand : 6 graded stone aggregate 40 mm nominal size).
10Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto two stories excluding cost of centring, shuttering, finishing and reinforcement : 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size) (As per design mix)
11Extra for laying reinforced cement concrete in or under water and/ or liquid mud including cost of pumping or bailing out water and removing slush etc., complete.
12Centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
13Providing at site, lowering & laying in trenches, aligning & jointing of PVC-U pipes (SN 8) as per IS 15328 (amended up to date) and as per specifications with rubber rings with socket and spigot joint, (EPDM/SBR) for all depths for pipe length as per drawing and specification including hydraulic field testing (including the cost and conveyance of water to site for testing) and commissioning etc complete as directed by Engineer. Note : E/w to be measured and paid separately. Length of pipe shall be measured in between the outer wall of two manholes / Inspection chambers. Pipe in the manhole/inspection chamber’s wall shall deemed to be included in the item of manhole/inspection chamber shall not be payable. : 110 mm nominal dia
14Construction of embankment with approved materials deposited at site available from roadway cutting and excavation from drain andfoundation of other structures, graded and compacting by vibratory roller 8-10 tonne to meet requirement of table 300-2 as per MoRT&H specification clause 305.
15Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : 1:1:2 (1 Cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size) (As per design mix)
16Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications and as per clause 2504 of MoRT&H Specification. With R.R. Stone/ bolder, weighing not less than 40 kg, thickness not less than 150mm, Specific gravity not less than 2.65.
17Providing and laying lean cement concrete 1:4:8 in Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid manualy, compacting with surface vibrator, finishing and curing complete as per clause 601, 112 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion.
18Providing and fixing precast cement concrete M-20 grade (Using mechanical Concrete Mixer) kerb stone top and bottom width 115 and 165 mm respectively, 250 mm high on 150 mm thick PCC M-10 grade foundation as per design, including fixing at site as per clause 408 of MoRT&H Specification including all material, labour, machinery, lighting, guarding and maintenance of diversion.
19Providing and laying un-reinforced, dowel jointed, plain cement concrete mix in pavement over a prepared sub base with 43 grade cement, coarse and fine aggregate conforming to IS: 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades complete as per drawing and as per clause 602, 112 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion. PCC M-25
20Providing and fixing Marble stone flooring table rubbed, 15-18 mm thick over 20mm (Av.) thick base of CM 1:4 (1 cement : 4 coarse sand) or slab in wal, steps, pillars, counters, jambs, shelves, sills etc laid over 12mm (Av.) thick base of CM 1:3 (1 cement : 3 coarse sand), jointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.Bhaislana,Abu,Kishangarh Zebra (Black Marble) Above 3601 Cm2 Slabs
21Kota stone slab flooring 25mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : Area of each slab 900 to 2000 sqcm
22Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
23Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.Green / Black Above 3601 Cm2 Slabs
24Providing and fixing of 60mm thick precast cement concrete interlocking paver block casted with rubber moulds in approved reflective colour and design having minimun compressive strength of 300 kg/ sq cm. The CC paving blocks be laid on average 50mm thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined.Complete job is to be executed as per the instruction of Engineer incharge. The rates to be inclusive of all lead & Lifts etc. complete as per specifications.
25Flooring with Cobble stone of approx. Size 125x125x75 mm (thick) laid on 25 mm average thick cement mortar 1:3( 1 cement : 3 Coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the stone, laid in approved patterncomplete in all respect as per direction of Engineer-in-charge.
26Providing and fixing 50 mm dia G.I. steel pipe railing in 3 rows duly painted on medium weight steel channels (ISMC series) 100 mm x 50 mm, 1.2 metres high above ground, 2 m centre to centre, complete as per approved drawings including all material, labour.
27Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing including cost of cutting, bending, welding etc. The frame work shall be supported in wall with the help of MS brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size) of size 300x230x300mm including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/RCC surface including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding the steel work will be given a priming coat of "ZINC" primer as approved byEngineer-in-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid.)
28Providing 1.20 metre high fencing with angle iron posts 50 mm x 50 mm x 6 mm at 3 metre center to center with 0.40 metre embedded in M15 grade cement concrete, corner, end and every 10th post to be strutted, provided with welded steel wire fabric of 75 mm x 50 mm mesh or 75 mm x 25 mm mesh and fixed to iron posts by flat iron 50 x 5 mm and bolts etc. complete in all respects including all material, labour.
29Dismantling of existing structures like culverts, bridges, retaining walls, CC road and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 50 metres as directed by Engineer. Cement Concrete Grade M-15 and above and PCC blocks
30Dismantling of existing structures like culverts, bridges, retaining walls, CC road and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 50 metres as directed by Engineer. Dismantling Brick / Tile work In cement mortar
31Dismantling of barbed wire fencing/ wire mesh fencing including posts, foundation concrete, back filling of pit by manual means including disposal of dismantled material with all lifts and up to a lead of 1000 metres, stacking serviceable material and unserviceable material separately as per MoRT&H specification clause 202.
32Removal of telephone / Electric poles including excavation and dismantling of foundation concrete and lines under the supervision of concerned department, disposal with all lifts and up to a lead of 1000 metres and stacking the serviceable and unserviceable material separately as per MoRT&H specification clause 202.
33Coursed rubble masonry (First sort) work in cement mortar 1:3 (1 cement : 3 coarse sand) with mechanical mixer in substructure/ super structure at all levels complete as per clause 1400 and 2200 of MoRT&H specification including all material, labour, scaffolding etc but excluding pointing and plastering.
34Brick work with modular bricks of class designation 75 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
35Brick work with modular bricks of class designation 75 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) + Extra for brick work in superstructure above two stories for each two stories or part thereof by mechanical means by lifting material using mobile crane .
36Half brick masonry with FPS bricks of class designation 75 in superstructure above plinth level upto two stories. Cement mortar 1:4 (1 cement :4 coarse sand)
37Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 15 mm cement plaster on the rough side of single or half brick wall of mix :1:4 (1 cement : 4 fine/ coarse sand)
38Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: Two or more coats on new work
39Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar).
40Providing and fixing of precast concrete interlocking tiles of desired shape of M 30 grade manufactured from fully computerized automatic stationery hydraulic viebro pressed machine and fully computerized automatic batching plant of class A1/A2 as per BS 6717:2001. The CC interlocking paving blocks be laid on average 50mm. thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined.Complete job is to be executed as per the instruction of Engineer incharge. The rates to be inclusive of all lead & Lifts etc. complete as per specifications. Tensile splitting strength, abrasion and braking load etc. as per BS 6717:2001, Grey cement. 60mm thick
41Pointing on stone work with cement mortar 1:3 (1 cement : 3fine sand) : Raised and cut pointing
42Providing and Laying Reinforced cement concrete pipe NP4/ prestrssed concrete pipe for culverts including jointing ends and fixing collar with cement mortar 1:2 complete as per clause 1000 & 2900 of MoRT&H specification including all material, labour form work, machinery. 200 mm internal diameter
43Providing and Laying Reinforced cement concrete pipe NP4/ prestrssed concrete pipe for culverts including jointing ends and fixing collar with cement mortar 1:2 complete as per clause 1000 & 2900 of MoRT&H specification including all material, labour form work, machinery. 300 mm internal diameter
44Providing and Laying Reinforced cement concrete pipe NP4/ prestrssed concrete pipe for culverts including jointing ends and fixing collar with cement mortar 1:2 complete as per clause 1000 & 2900 of MoRT&H specification including all material, labour form work, machinery. 900 mm internal diameter
45Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 15 mm nominal outer dia .Pipes.
46Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 40 mm nominal outer dia .Pipes.
47Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 50 mm nominal outer dia .Pipes.
48Constructing masonry Chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design :With bricks
49Construction of precast/ cast-in-situ RCC railing M-30 grade, true to line and grade, center to center spacing between vertical post not to exceed 2000mm leaving adequate space between vertical post for expansion, complete as per drawing and technical specification and as per clause 1500, 1600, 1700 & 2703 of MoRT&H Specification including all material, labour, machinary etc.
50PART - I, ( LAKE CLEANING & EARTH FILLING WORKS )
51Cleaning and removal of earth, silt, sludge, kankar, boulder, building material and garbage in existing nallah/drains including construction of bye pass arrangement to byepass water with 1.5m lift from ground level and lead upto 50 mincluding foul & saturated condition where pumping out or bailing out of water is required, including shoring, shuttering where required and dewatering. Making access for disposal and dressing disposal side as per the directed of the Engineer. For Depth upto 1.50 m
52Carriage of Materials by mechanical transport including loading, unloading and stacking :: Earth, Sand, bazri, ballast, kankar, Stone, boulders, gravelly Etc. materials up to 5 Km.
53PART - J, ( TOILET BLOCK )
54Reinforced cement concrete work inbeams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto two stories excluding the cost of centring, shuttering, finishing and reinforcement: M-25 Grade Concrete (1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size) -As per design mix
55Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which approach is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion).
56Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting offollowing operations: b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to With average thickness of 120mm and minimumthickness at khurra as65 mm.
57Brick work with modular bricks of class designation 75 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) + Extra for brick work in superstructure above two stories for each two stories or part thereof by mechanical means by lifting material using mobile crane .
58Extra for providing edge moulding to 15-18mm thick marble/ Granite stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite Work
59Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side having 12 mm air gap including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant ) etc. as per specifications, drawings and direction of Engineer-in-charge complete.
60Providing and fixing double leaf door wooden shutters made of Ist grade wood as per traditional design (Deshi pattern) planks thickness 40mm and width of Binies, Andheri 50mm and 35mm, including Adwa etc. with fittings (nails, sankal, kunda, cheri, handle and patti etc.) as per existing matching/ as per approved design with moulding/ carving complete in all respect :Sheesham wood grade Ist
61P & F 1st quality Vitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etc complete. Size 600 mm X 600 mm
62Wiring of light point / fan point / exhaust fan point / call bell point with 1.5 sq. mm FR PVC insulated unsheathed 1.1kV grade flexible copper conductor and 1.5 sq.mm FR PVC insulated copper earth conductor (IS:694) of approved makein double lock/ ISI marked single lock pvc casing capping & it"s accessories, 18 SWG M.S. box with earth terminal, screwless cage connectors for neutral looping in switch board& false ceiling point,6 A switch 3.0 mm thick phenolic laminated sheet, zinc plated / brassscrews, cup washers ,making connections, testing etc. as required. Medium point (up to 6 mtr.), Group-1
63Centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete. , Lintels, beams, plinth beams, girders, bressumers and cantilevers
64Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 20 mm cement plaster of mix : 1:3 (1 cement : 3 fine/ coarse sand)
65Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer"s specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work
66Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing including cost of cutting, bending, welding etc. The frame work shall be supported in wall with the help of MS brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size) of size 300x230x300mm including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/RCC surface including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding the steel work will be given a priming coat of "ZINC" primer as approved byEngineer-in-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid.)
67Mud mortar.
68Hume Pipe & Cover
69Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths full round HDPE DWC (double wall corrugated) pipes of SN8 grade as per IS 16098 (Part 2) amended upto date in trenches in complete including all material, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications, drawings and as per direction of Engineer. Note : E/w to be measured and paid separately. 150 mm ID
70Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.
71Concealed stop cock, 15mm nominal bore, 108mm long. Weighing not less than 108 gms.
72Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests.
73Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid.
74Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern.
75Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern,includingpainting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps.
76Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 40mm nominal bore, 206mm long. Weighing not less than 690 gms.
77Cutting holes upto 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc.and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including finishing complete so as to make it leak proof.
78Providing and fixing square-mouth S.W. gully trap grade "A"’ complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 180x150 mm size P type With Sewer bricks conforming to IS : 4885
79Gemaria Lake-1
80Flooring with Cobble stone of approx. Size 125x125x75 mm (thick) laid on 25 mm average thick cement mortar 1:3( 1 cement : 3 Coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the stone, laid in approved patterncomplete in all respect as per direction of Engineer-in-charge.
81Plain cement concrete 1:3:6 mix with crushed stone aggregate mechanically mixed, placed in foundation and compacted by vibration including curing as per clause 1000 &1700 of MoRT&H specification including all material, labour form work, machinery. Using stone aggregate 40 mm nominal size
82Providing & Fixing of IP40 LED Surface/ Recessed / suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. High efficiency with 2.5 KV internal/external surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection and in compliance to IEC standards (Integral with light fixture). System lumen efficacy of = 120 lm/Watt ,THD < 10 % , p.f.=0.95,CRI >80 ,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing.
83OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure "A" attacheded with this BSR.
84Suspended Mounting/Surface Moutning
8536W LED light fixture 2"x2" with acrylic / prismatic front cover.
86Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitableshadewithordinarypaint of approved brand and manufacture.
87Providing and laying marking of center line and stop line etc with hot thermoplastic compound 2.5 mm thick on road/ plain surface, including reflectorising glass beads @ 250 gms per sqm area with special applicator machine, as per IRC:35 including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control involved. The finished surface to be level, uniform and free from streaks and holes as per clause 803 of MoRT&H Specification including all material, labour, machinery, lighting, guarding and maintenance of diversion.
88Providing and Laying Reinforced cement concrete pipe NP4/ prestrssed concrete pipe for culverts including jointing ends and fixing collar with cement mortar 1:2 complete as per clause 1000 & 2900 of MoRT&H specification including all material, labour form work, machinery. 250 mm internal diameter
89Providing, lowering, laying in trenches, aligning, fixing in position and jointing socketed rubber gasket type ISI marked uPVC pipes of Class III (6 Kg/sqcm) suitable for potable water with rubber ring joints (as per IS 4985-2000) of following outer dia with all accessories (excluding specials) complete including all material, labour, hydraulic testing and commissioning as per Technical Specifications and as per direction of Engineer Note : E/w to be measured and paid separately. 90 mm dia
90Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 25 mm nominal outer dia .Pipes.
91Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved qualityL D- 2.5, Rectangular shape 600x450mm internal dimensions
92Part-B: HORTICULTURE, LANDSCAPE, BEAUTIFICATION WORKS
93Spreading of sludge farm yard manure or/ and good earth in required thickness (cost of sludge, farm- yard manure or/and good earth to be paid for separately).
94Grassing with "Doobs" grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed. In rows 7.5 cm apart in either direction
95Supply and planting following in poly bags / earthen pots well branched, well established & free from disease of 900 mm min. height plants at site in 0.60 m dia holes,1 m deep dug in the ground,mixing the soil with decayed farm yard/sludge manure,backfilling the hole watering etc as required.
96Ficus panda
97( Ratanjot)
98( Choti Aari)
99( Chandni)
100( Firebush, Thal Kamal)
101( Guddal)
102Trenching in specified soil upto a depth of 60 cm. including removal and stacking of serviceable materials and then disposal by spreading and neatly leveling within a lead of 50 metres and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and farm-yard manure before and after flooding with water (excluding cost of imported earth and sludge or farm-yard manure).
103Supplying and stacking good earth at site of work. Note: 1) Loading, unloading and carriage to be paid extra as per actual lead. 2) Earth measured in stacks will be reduced by 20% foe payment
104Supply at site of work well decayed farm yard manure,from any available source,approved by the engineer in charge including screening and stacking.
105Grassing with "Carpet" grass (selection no. 1) including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed.(The good earth shall be paid separately) In rows 5 cm apart in either direction
106Supply and planting following speciesbest quality container grown healthy trees of 3 mt. min. height, well established & free from disease at site in 1.20 m dia holes,1.20 m deep dug in the ground,mixing the soil with decayed farm yard/sludge manure,backfilling the hole watering etc as required.
107Plumeria alba ( Champa) 3 M height minimum
108Gulmohar(Delonix regia)
109Jacaranda mimosifolia(Neelli Gulmohar)
110Bottle Brush(Callistemon Lanciolatous)
111Bamboo Palm
112Supply and planting following species best quality container grown healthy trees of 2 mt. min. height, well established & free from disease at site in 0.90 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required.
113Bignonia Venusta
114Morning glory (Ipomea)
115Vernonium ( Parda Bel)
116Cassia fistula
117Supply and planting following species best quality container grown healthy trees of 0.15 to 0.45 mt. min. height Submerged Plant
118Aerva Juvanica
119Grewia Tenax
120Sarcostmma acidum
121Cadaba fruiticosa
122Phylanodiflora
123Ghambra
124Vajradanti
125Kunden
126Supply and planting following species best quality container grown healthy Shrub Plant of 0.6 mt. min. height.
127Anogeissus spp.
128Madhuca indica
129Flacourtia indica
130Boswelia serrata
131Manilkara hexandra
132Tectona grandis
133Cassia fistula
134Butea monosperma
135Bauhinia racemosa
136Bauhinia variegata
137Sterculia urens
138Firmiana colorata
139Cordia myxa
140Cordia gharaf
141Ficus virens
142Ficus religiosa
143Ficus benghalensis
144Ficus palmata
145Desmodium oojeinensis
146Craeteva religiosa
147Albizia lebbeck
148Erythrina variegata
149Emblica officinalis
150Aegle marmelos
151Diospyrous melanoxylon
152Lannea coromandelica
153Bombax ceiba
154Feronia limonia
155Schleichera oleosa
156Dalbergia sisso
157Supply and planting following species best quality container grown healthy trees of 3 mt. min. height
158Mitragyna parviflora
159Gmelina arborea
160Terminalia arjuna
161Terminalia bellerica
162Terminalia chebula
163Wrightia tinctoria
164Holoptelea integrifolia
165Grewia spp
166Acacia nilotica
167Tamarix aphylla
168Prosopis cinereria
169Tecomella undulata
170Capparis decidua
171salvadora oleoides
172Acacia senegal
173Acacia leucophloea
174Capparis sepiara
175Butea monosperma
176Cordia spp
177Salvadora persica
178Zyziphus jujube
179Aegle marmelo
180Supply and fixing different type of steel pre-fabricated garden bench/ jhula/ slides and other children play items made of steel duly painted as per approved design and specifications by engineer in charge made of MS pipe, Flates, rectangular hollow section or other steel sections duly welded and or nut bolted where ever required, rubbing and buffing welded joints to make safe for use of children and painted in approved pattern complete as required.
181Supply and erection of M.S. Galvanized Octagonal pole ( as per BSEN 40-3-3:2003 /BSEN 10025/IS 2062 IS:875 Part-1 – 2015/ for MS plate for baseflange )of following length and dimension as per table P-01 with base plate on the cement concrete foundation of M20 grade (1:1.5:3) as perIS 456/IS 2911. with the help of anchor bolts of grade 6.8 (IS: 1367 P III ).The pole shall have a weatherproof flush door and locking arrangements. complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, 4.0 Mt
182Developement of Trail
183Stone pitching/ dry stone spells
184Part-C: Miscellaneous Works
185( SMALL DECORATIVE FOUNTATION WORK )
186Supplying, Installation and commissioning of ring type fountain including - 24 ft G.I 40mm Ring Pipe - 1/4 single adjustable jet nozzles - 5 h.p submmersible pump classic ISI - RGB Led Light 24 Watt - SMPS - Header 6 way - Valve UPVC - 1.5" UPVC Pipes - 3" UPVC Pipes - Ring Supporting Stand - Light Fixing Clamp - Electrical Wiring inside the fountain tank - Starter, - Water Filter Grill etc. all type of Acessories. Repering till the end of Maintenance Period as per the instruction of EIC and Architect.
187( FLOATING JETTY )
188Wooden ballies 4" Dia
18925mm wooden planking, tongued and grooved in flooring including fixing with iron screws complete with,Second class teak wood
190Providing and fixing all type of acessories for floating wooden jetty with 1 Year Maintenance Period as per the instruction of EIC and Architect.
191Installation, Testing & Commissioning of floating fountain 01. Floating body of FRP Materials of size 4ft. dia. X 10” thickness FRP of double coated Including extra materials for easy weight holding capacity with chemical polishing for extra water resistence capacity to durability. Make: AE- (1 Nos) 02. Anchoring of floating body with proper anchoring material(SS-304) to hold a floating body. Make:Any approve mak (40 Rmt) 03. Centre jet of high shooter nozzle of size 2”inch. bore of SS-304 CNC with nickel chromium plating with control valve. Make: AE(1 Nos) 04. Multi colored RGB LED Light 9W,12V SS-304-body, fixture with water proof Light (IP 68) protected ,dynamic color changing capability, toughen glass with elastomer sealed. Make: AE (4 Nos) 05. Controllerforprogrammable colour changing system with 6-8 station changing option with RGB LED Light Make: AE(1 Nos) 06. Submersible pump5Hpwith requiredsizeof suction stunner and other fittings with all respect. Make: Crompton/Kirlosker (1 Nos) 07. Pump holding GI L-Type Channel for the proper weight & balance of pump. (Job Work) 08. Outdoor electrical Panel of 5hp pump(MCB,OLR,Push button switch, light indicator,voltmeter,ammeter etc. Make: L&T,Snider,any approve make etc.) Assemble by: AE (1 Nos) 09. Electrical submersible cable complete in all respect of 4 core round 1.5mmcopper conductor. Make:Deep cable/finolex/any approve make (1 Set) 10. Electrical submersible cable complete in all respect of 3 core flat 2.5mm copper conductor,PVC insulated flat wire for pump. Make:Deep cable/finolex/any approve make (1 Set) 11. UPVC Plumbing and its fittings in 10kg pressure with bush,socket,T,Elbow,controlvalve,gate valve, etc. Make: Prince/Supreme (Required) 12. Installation,Testing and commissioning (Job) 13. Transportation
192Part-D: Electrical Works
193Supply installation testing & Commissioning of ISO certified company made high mast lighting system (as per PLG 07of ILP UKtechinical report no7 of ILE UK /IS:875 Part-1 – 2015//BSEN10025/and IS:2062 )consisting of totally hot dip galvanised by single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries with welded arm (excluding luminares), mast head frame assembly with full cover, including 1 No. LED 15 Watts aviation obstructionlights, double drum type self sustaining winch, integral power tool accesible from door with padlocking arrangement ( winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, S.S. ropes (AISI 316, 7 / 19 costruction ), EPR insulated PCP sheathed trailing cable, including outdoor type control panel for auto on / off, reverse / forward motor operation and CC foundationof M - 25 grade complete as requiredas per IS 456/IS 2911. The mast is constructed from mild steel plates (as per IS 5986 Gr. 510 ) cut and folded to form a polygonal section, telescopic jointed and welding as per BS 5135.16.0 Mtr HM (in 2 section)
194S& F of all in one solar LED street light fixture with Integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro Phosphate battery with BIS approved make .luminaire should be secondary optic lenses for better distribution with delivered efficacy of > 100 Lumen perwatt.Bidder shall have in house R&D Laboratory which is recognised byministry of Science & Technology department, Govt. Of India/NABL.Bidder shall haveinhousepole &luminairem anufacturing facility.Luminairecanbe suppliedwithHybridswitchalongwithindicatortounderstandthesourceofpower( eitherfromsolarorACsupply).shallhavecertificatetestedfrom MNRE approved Lab.Guaranteefor total system is two years .Note: All the above should be integrated and should be 1 system.Compact Solar LED Street Light - 60W(MONO) 18V/ 12.8V 27Ah/40W, Group-1
195S& F of all in one solar LED street light fixture with Integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro Phosphate battery with BIS approved make .luminaire should be secondary optic lenses for better distribution with delivered efficacy of > 100 Lumen perwatt.Bidder shall have in house R&D Laboratory which is recognised by ministry of Science & Technology department, Govt. OfIndia/ NABL. Bidder shall haveinhouse pole & luminaire manufacturing facility. Luminairecanbe suppliedwithHybridswitchalongwithindicatortounderstandthesourceofpower( eitherfromsolarorACsupply).shallhavecertificatetestedfromMNRE approved Lab. Guaranteefor total system is two years .Note: All the above should be integrated and should be 1 system. make: Bajaj/ Philips / Crompton.Compact Solar LED Street Light - 40W(MONO) 18V/ 12.8V 21Ah/20W
196P & F of IP68, IK10 protected LED Buried marker light /Step Light Fixture. Fixture made of powder coated die cast aluminium with Toughened Glass cover and appropriate beam angle lens to be used as per requirement. The System level Luminous efficacy must be >90 Lumen/W. High Power LEDs at 1W/2W per LED. The driving current should be Minimum 350 mA per LED. CRI>70, CCT: 3000/6500 K. The integral SMPS based electronic driver must be constant current and surge protection of min. 4KV(L-N) and efficiency >85%, PF>0.9 and input Voltage range of 90-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained. Light should include quick connecting cable coupled with various mounting accessories. Light output in Cool white or Warm White Colour as per engineers choice. Fixture must be in compliance with IS/CE Standards. Burial Light - 5W L-7 MODEL
197P & F of IP68, IK10 protected LED Buried marker light / Step Light Fixture. Fixture made of powder coated die cast alluminium with Toughened Glass cover and appropriate beam angle lens to be used as per requirement. The System level Luminous efficacy must be >90 Lumen/W. High Power LEDsat 1W/2W per LED. The driving current should be Minimum 350 mA per LED. CRI>70, CCT: 3000/6500 K. The integral SMPS based electronic driver must be constant current and surge protection of min. 4KV(L-N) and efficiency > 85%, PF>0.9 and input Voltage range of 90-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained. Light should include quick connectingcable coupled with various mounting accessories. Light output in Cool white or Warm White Colour as per engineers choice. Fixture must be in compliance with IS/CE Standards. Rectanglar LED Marker Light
198S& F of all in one solar LED street light fixture with Integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro Phosphate battery with BIS approved make .luminaire should be secondary optic lenses for better distribution with delivered efficacy of > 100 Lumen perwatt.Bidder shall have   in house   R&D Laboratory which is   recognised   by   ministry of Science & Technology department, Govt. Of India/NABL. Bidder shall have  in house pole & luminaire manufacturing   facility. Luminaire  can  be   supplied  with  Hybrid  switch  along  with  indicator  to  understand  the  source  of  power( either  from  solar  or  AC  supply).shall  have  certificate  tested  fromMNRE   approved   Lab.Guarantee    for   total   system   is   two   years .Note: All the above should be integrated and should be 1 system. Compact Solar LED Street Light - 40W(MONO) 18V/ 12.8V 21Ah/20W, Group-1
199Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un armoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling ofexcavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc.as required of size. 10.0 Sq.mm 3 core
200Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un armoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling ofexcavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc.as required of size. 16.0 Sq.mm 2 core
201Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un armoured / Armoured aluminium cable of 1.1 KV grade as per PWD specification for electrical Works in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling ofexcavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc.as required of size. 16.0 Sq.mm 4 core
202P/Laying P.V.C/XLPE insulated & P.V.C sheathed cable of 1.1 KV grade with Copper conductor of IS: 1554 P-I/IS: 7098 P-I in ground as per IS: 1255 including excavation of 30cm x 75cm size trench, 25cm thick under layer of sand, IInd class bricks covering, refilling earth, compaction of earth, making necessary connection, testingetc. as required of size..2.5 Sq. mm4 core
203Supply and fixing sign board upto 4.5 meter height made of the following specifications board base of A.C.P / transparent PVC acrylic sheet 3 mm thick fixed on MS hollow rectangular section size 50mmx25mm, letters made of acrylic material sheet 3 mm thick of any colour fixed with LED lights with all accessories and wiring with copper wire complete as required and as per direction in engineer in charge.
204Rewinding of Heavy duty Exhaust fan motor including all necessary material,The motor is to be wound taking no. of coils,turns and pitch as it was originally wound with required size super enamelled wire with "E" class insulation material and making connections etc. as required 450 mm sweep
205Providing & Laying XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 10.0 Sq.mm 3 core
206Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from polycarbonate /extruded aluminium powder coatedhousing with in built driver, Power Consumption of18W/20W ,system lumen efficacy = 120 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% ,p.f.=0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, 4" LED Tube shape fixture 18/20 W (Polycarbonate Base)
207Providing & Fixing of ISO Certified company made BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan as per PWD specification for electrical Works, Conform to all the performance requirements laid down in IS:374-2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) or Quality Certification such as ISO - 9001 or above. with down rod up to 30 cm with secondary supportsafety cable ( steel wire ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , 1200 mm Sweep BEE 3 Star rated
208Wiring of 3/5 pin 6 amp. Light plug point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694)and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) vergin material PVC conduit & it"s all accessories( J.B. , Bends etc.) , round tiles,18 SWG G.I. box with earth terminal of required size,6 Aswitch, 3/5 pin 6 A socket, 3.0 mm thick ISI marked phenolic laminated sheet (IS : 2036 -1995),Al. alloy/ cadmium plated iron screws 20 mm cup washers etc. all as per pre approved by Engineer in charge,making connections, testing etc. complete as required. For specification of copperConductor,Phenolic Laminated sheet"s & Electrical/ Wiring accessoriesrefer Chapter E - 04, E - 05 & E - 07. For additional technical parameters of products/ work,Long point(up to 10 mtr..)
209Supply and erection of M.S. Galvanized Octagonal pole ( as per BSEN 40-3-3:2003 /BSEN 10025/IS 2062 IS:875 Part-1 – 2015/ for MS plate for baseflange )of following length and dimension as per table P-01 with base plate on the cement concrete foundation of M20 grade (1:1.5:3) as perIS 456/IS 2911. with the help of anchor bolts of grade 6.8 (IS: 1367 P III ).The pole shall have a weatherproof flush door and locking arrangements. complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work,7 Mtr.
210Supply and erection of M.S. Galvanized Octagonal pole ( as per BSEN 40-3-3:2003 /BSEN 10025/IS 2062 IS:875 Part-1 – 2015/ for MS plate for base flange )of following length and dimension as per table P-01 with base plate on the cement concrete foundation of M 20 grade (1:1.5:3) as per IS 456/IS 2911. with the help of anchor bolts of grade 6.8 (IS: 1367 P III ). The pole shall have a weatherproof flush door and locking arrangements. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , 3.0 Mt
211Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12material , toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps . Integrated driver must be potted & has a unique BIS R number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety . Input Frequency 50Hz±3%, Power Factor >0.95 ,driver Efficiency >85% , THD(I) <10% , driver current <1000mA shown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be provided, Surge Protection Min >=4KV internal and 10KV external, System life of 30000 Burning hours with 70% of Initial Lumens maintained, color Rendering Index >70 and CCT 5700K ±355K. Driver current <1000mA shown in LM79 report. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , High power LED flood light 50 watt
212Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12material , toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps . Integrated driver must be potted & has a unique BIS R number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety . Input Frequency 50Hz±3%, Power Factor >0.95 ,driver Efficiency >85% , THD(I) <10% , driver current <1000mA shown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be provided, Surge Protection Min >=4KV internal and 10KV external, System life of 30000 Burning hours with 70% of Initial Lumens maintained, color Rendering Index >70 and CCT 5700K ±355K. Driver current <1000mA shown in LM79 report. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced. OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , High power LED flood light 70 watt
213Providing and fixing “SWISS” type bollard 134cm height made out of 1.25mm thick M.S. sheet welded in conical section having upper dia 15cm and lower dia 20cm with another attachment of mandatory 7mm thick plate and fixed with the help of 7cm long, 30cm dia chrome plated MS tube, this part is fixed on the body with another attachment of a cap 30x7cm, whole body is painted in black stove enamel and mandatory plate in azure blue with one compulsorykeep left arrow with 10mm border reflective strip each of 7.5cm on body complete in all respect including all material, labour, diversion
214Providing and laying XLPE/PVC insulated & PVC sheathed armoured control cables of 1.1 KV grade with copper conductor as per IS 1255 including excavation of 30 CmX75 Cm size trench 25 Cm thick under layer of sand and IInd class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 2.5 Sq.mm 4 core
215Providing, lowering, laying in trenches, aligning, fixing in position and jointing socketed rubber gasket type ISI marked uPVC pipes of Class III (6 Kg/sqcm) suitable for potable water with rubber ring joints (as per IS 4985-2000) of following outer dia with all accessories (excluding specials) complete including all material, labour, hydraulic testing and commissioning as per Technical Specifications and as per direction of Engineer Note : E/w to be measured and paid separately. 110 mm dia
216Wiring of 3/5 pin 6 amp. Light plug point as per PWD specification for electrical Works with ISI marked 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694)on surfaceISI marked ( IS:14927 P - II ) UPVC casing capping & it"s accessories like coupler, inner, outer, elbow, square box, tee, end cap etc., Hot Dipped Galvanized Modular box of 18 SWG with earth terminal/ surface moulded UPVCModular box, 3/5 pin 6 A modularswitch, 6 A modular socket, Modular face plate with grid plate, screws,, all as per pre approved by Engineer in charge, making connections, testing etc. complete as required. For specification of copperConductor,Phenolic Laminated sheet"s & Electrical/ Wiring accessories.
217SITC of floor mountedPMCC (Indoor, Dust proff IP-4x front operated with 2 mm thick sheet metal compartmentalised) with all accessible parts, head shrinkable sleeves, SMC/DMC bus bar supports, padlocking facility on outgoing feeders etc. Incommer feeder (drowout type )for transformer 630A/800A, 50KA, ACB 3 pole, Al Bus Bars,Digital Multifunction meter compatable to SCADA,metering,Protection CT"s, IDMT 3-O/C & 1-E/F, indicating lamps, control fuse, wiring etc.complete in all respect of the size appxo 900(D)X.2400(H)X1000(D)
21858.31 P/ F IP-65/ IP-66 protected street light luminaries on existing bracket. Fixture made from powder coated single piece pressure die cast aluminum housing with heat dissipation fins on housing with high power LEDs . Diffuser / glass cover for ensuring IP-65 protection for lamp and control gear compartment, system lumen output of 100 lum/watt high power LED. Integrated driver shall be high efficiency having efficiency more than 85 % and in compliance to IEC standards. System life of 50000 burning hours with 70 % of initial lumens maintained. Fixture shall be in CE compliance. 58.31.1 IP-65 protected LED street light luminaries 58.31.1.4 LED street light fixture60 Watt
219Supply installation testing & Commissioning of ISO certified company made high mast lighting system (as per PLG 07 of ILP UK techinical report no 7 of ILE UK /IS:875 Part-1 –2015//BSEN10025/and IS:2062 )consisting of totally hot dip galvanised by single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries with welded arm (excluding luminares), mast head frame assembly with full cover, including 1 No. LED 15 Watts aviation obstruction lights, double drum type self sustaining winch, integral power tool accesible from door with padlocking arrangement ( winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, S.S. ropes (AISI 316, 7 / 19 costruction ), EPR insulated PCP sheathed trailing cable, including outdoor type control panel for auto on / off, reverse / forward motor operation and CC foundation of M - 25 grade complete as required as per IS 456/IS 2911. The mast is constructed from mild steel plates (as per IS 5986 Gr. 510 ) cut and folded to form a polygonal section, telescopic jointed and welding as per BS 5135. ( See table P - 03 for specs.) OEM Must have Type test certificate for wind tunnel test for High mast fixtures. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, 16.0 Mtr HM (in 2 section)
220P & F of IP68, IK10 protected LED Buried marker light /Step Light Fixture. Fixture made of powder coated die cast aluminium with Toughened Glass cover and appropriate beam angle lens to be used as per requirement. The System level Luminous efficacy must be >90 Lumen/W. High Power LEDs at 1W/2W per LED. The driving current should be Minimum 350 mA per LED. CRI>70, CCT: 3000/6500 K. The integral SMPS based electronic driver must be constant current and surge protection of min. 4KV(L-N) and efficiency >85%, PF>0.9 and input Voltage range of 90-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained. Light should include quick connecting cable coupled with various mounting accessories. Light output in Cool white or Warm White Colour as per engineers choice. Fixture must be in compliance with IS/CE Standards. (Burial Light - 5W Equivalent to L-7 MODEL)
221Supply, installation, testing and commissioning ofMNRE approved Grid tied Solar Panels with inverter, meter, cable etc. suitable for Rooftop installation as well as Utility Scale Solar Power Projects with 25 years of Linear Generation warranty. Work includes designing of solar panel area and MS frame and foundation on ground/roof of Pump house or CWR, showing arrangement of panel in available space, installation ofPV module on MS frame as per approved design and drawings. Mountingstructure shall be suitably designedto withstand wind velocity up to 150km/hr. Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiency of >98%. Connect up to multiple strings PV arrays, Easy & fast connection, Built-in string-level monitoring, IP65 protection level, Wi-Fi / internet based remote monitoring with 5 years warranty. All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive. The work shall be executed as perdetailedtechnical specifications, approved drawing and direction of Engineer in Charge. Note: There shall be 5 year service warranty for panel, inverter, meter, cable etc. andsuitable provision shall be included in tender document.
2223 KW each at Toilet block & Security Cabin Masania Lake, Loharia lake & Gamaria Lake
223Part E- Provisional Sum
224Provision of Provisional sum to be used as tender document (fixed) : INR 50,00,000. Bidder should fill amount INR 50,00,000.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail