Health and Family Welfare Statutory Bodies & Commissions/Committees Closing in 0 days TDR #34331923

Tender For Supply Of Blood Bank Equipments

Issued by Statutory Bodies & Commissions/Committees · Palakkad, Kerala
Tender Value
13.60 Lakhs
Estimated cost
Bid Submission
22 Oct 2022
0 days left
EMD
13600
Bank guarantee accepted
Document Fee
2720
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Palakkad → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Supply Of Blood Bank Equipments Supply Of Blood Bank Equipments , Rh / Slide Viewing Box , Rh / Slide Viewing Box: For Viewing Of Agglutinationon Slides Light Source : Cfl Power Supply : 230V Ac , Laminar Flow Bench Type , Laminar Flow Bench Type: Type : Horizontal Work Bench Size: 3 X 2 X 2 Ft Classification: Class 100 Main Filter : Minipleat Hepa, Particle Retention Size : Up To 0.3 Micron, Efficiency : 99.999% Pre Filter: Particle Retention Size : Up To 10 Micron, Efficiency: 98% Work Table: Ss 304 Cabinet:Gi Powdercoated Uv Light: Uv Lamp Of Suitable Length Illumination : Fl Lamp Of Suitable Length Switches : On / Off For Blower, Uv, Fl Pressure Gauge :Inclined Liquid Column Manometer Pet Cock : Ss Petcock For Air / Gas Front Door: Foldable Polycarbonate Sheet Wheels : Castor Wheels Supply : 220-230 Volts Ac , Gel Card Centrifuge With Incubator For Cross Matching , Gel Card Centrifuge:-1. Capacity A. Swing Out Rotor Should Accommodate 12 Or Morer Standard Gel Cards. 2. Max Speed Of The Centrifuge Should Be 1600 10 Rpm 3. Max Rcf Should Be 279 1 % G 4. Should Have Audio Visual Alarms For Imbalance, End Of Cycle And Any Other Errors 5. Should Have Single Hand Rotor Removal For Cleaning 6. Should Have Lcd Display With Touch Key Pad 7. Motor Should Be Brushless 8. Net Weight Should Be Less Than 20 Kg 9. Power Supply Should Be 220-240 Volts, 50 Hz, Single Phasegel Card Incubator:-1. Incubator Should Accommodate 12 Or More Gel Cards And 12 Or More Test Tubes Simultaneously 2. Should Maintain Temperature At 37°C 1°C 3. Time Limit Adjustable Up To 60 Minutes 4. Should Have Programs To Adjust Incubation Temperature & Time As Specified By Gel Card Supplier 5. Should Have Audio Visual Alarms For High / Low Temperature And End Of Cycle 6. Should Have Auto Pop-Up Card Mechanism For Card Removal, When Lid Is Opened 7. Should Have Lcd Display With Touch Key Pad 8. Power Supply: 220-240 Volts, 50 Hz, Single Phase , Digital Haemoglobin Meter With Disposable Cuvettes , Digital Haemoglobin Meter With Disposable Cuvettes:Principle : Absorbance Measurement Of Whole Blood At An Hb / Hb02 Isobestic Point; Dual Wavelengths ( 506 Nm A Nd 880 Nm ) For Hb Measurement And Turbidity Compensation Calibration : Factory Calibrated Against The Icsh Reference Method; Needs No Further Calibration Sa Mple Material : Capillary, Venous Or Arterial Whole Blood Measurement Range : 0 -25.6 G / Dl ( 0-256 G / L, 0-15.9 Mmol / L ) Results :3 Seconds Sample Volume Rv Lo ?L Dimensions: 140X70 X160 Mm Weight : 500 G With Batteries Installed Storage Temp : Analyzer: 0-50 °C Microcuvettes : 10-40 °C. For Unopened Vials, The Storage Temperature Ca N Be Extendeddown To -18 °C And Up To +50 °C For A Period Of Maximum 6 Weeks. Operating Temp : 10-40 °C Power : Ac Adapter Or 4 Aa Batteries Interface: For Printer Quality Control: Built-In Selftest, Optional : Liquid Controls Cuvettes :- Std Pack : 200 Nos , Blood Donor Couch ( Fully Automatic ) , Blood Donor Couch ( Fully Automatic ) :Technicaldata Height : 620 - 820 Mm Seat Width : 680 Mm Profile Length : 2010 Mm Back Rest Adjustment: O Degree - 54 Degree Leg Rest Adjustment: O Degree - 60 Degree Trendelenburgposition: -15 Degree Castor Wheels : Fouroo Mm Lockable Wheels Voltage: 230V ± 100% , Blood Transportation Box Portable , Blood Transportation Box Portable:Capacity: 25 L Cold Life: When Ambient Temperature Is Below +30°C, It Can Maintain +2 To +Sc For About 10 Hours If Kept In Closed Condition.

BOQ

Name of Work: Supply of Blood Bank Equipments
Sl. No. Item Description
1RH/ slide Viewing box
2RH/ slide Viewing box: For viewing of agglutinationon slides Light Source : CFLPower Supply : 230V AC
3Laminar flow bench type
4Laminar flow bench type: Type : HorizontalWork Bench Size: 3 X 2 X 2 FtClassification: Class 100Main Filter : MINIPLEAT HEPA, Particle retention size : up to 0.3 Micron, Efficiency : 99.999%Pre Filter: Particle retention size : up to 10 micron, Efficiency: 98%Work Table: SS 304 Cabinet:GI PowdercoatedUV Light: UV Lamp of suitable lengthIllumination : FL Lamp of suitable length Switches : ON / OFF For Blower, UV, FL Pressure Gauge :Inclined Liquid Column ManometerPet cock : SS petcock for air / gasFront Door: Foldable polycarbonate sheet Wheels : Castor WheelsSupply : 220-230 Volts AC
5Gel card centrifuge with incubator for cross matching
6Gel card centrifuge:-1. Capacitya. Swing out rotor should accommodate 12 or morer standard Gel cards.2. Max speed of the centrifuge should be 1600 10 RPM3. Max RCF should be 279 1 % g4. Should have audio visual alarms for Imbalance, end of cycle and any other errors5. Should have single hand rotor removal for cleaning6. Should have LCD display with touch key pad7. Motor should be Brushless8. Net weight should be less than 20 kg9. Power supply should be 220-240 volts, 50 Hz, Single phaseGel card incubator:-1. Incubator should accommodate 12 or more Gel cards and 12 or more test tubes simultaneously2. Should maintain temperature at 37°C 1°C3. Time limit adjustable up to 60 minutes4. Should have programs to adjust incubation temperature & time as specified by gel card supplier5. Should have audio visual alarms for high / low temperature and end of cycle6. Should have Auto pop-up card mechanism for card removal, when lid is opened7. Should have LCD display with touch key pad8. Power supply: 220-240 volts, 50 Hz, single phase
7Digital Haemoglobin meter with disposable cuvettes
8Digital Haemoglobin meter with disposable cuvettes:Principle : Absorbance measurement of whole blood at an Hb/Hb02 isobestic point; dual wavelengths (506 nm a nd 880 nm) for Hb measurement and turbidity compensation Calibration : Factory calibrated against theICSH reference method; needs no further calibrationSa mple Material : Capillary, venous or arterial whole bloodMeasurement Range : 0 -25.6 g/dL (0-256 g/L,0-15.9 mmol/L)Results :3 seconds Sample Volume rv lO µL Dimensions: 140x70 x160 mmWeight : 500 g with batteries installed Storage Temp : Analyzer: 0-50 °CMicrocuvettes : 10-40 °C. For unopened vials, the storage temperature ca n be extendeddown to -18 °C and up to +50 °C for a period of maximum 6 weeks.Operating Temp : 10-40 °CPower : AC adapter or 4 AA batteries Interface: For PrinterQuality Control: Built-in \"selftest\", Optional : liquid controls CUVETTES :- Std Pack : 200 Nos
9Blood Donor Couch (fully automatic)
10Blood Donor Couch (fully automatic):TechnicalData Height : 620 - 820 mm Seat Width : 680 mmProfile Length : 2010 mmBack Rest Adjustment: O degree - 54 degree Leg Rest Adjustment: O degree - 60 degree Trendelenburgposition: -15 degreeCastor Wheels : FourOO mm lockable wheels Voltage: 230V ± 100%
11Blood transportation box portable
12Blood transportation box portable:Capacity: 25 LCold life: When ambient temperature is below +30°C, it can maintain +2 to +SC for about 10 hours if kept in closed condition.

AI Tender Summary

OUR REF NO 34331923
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 13.60 Lakhs
LAST DATE 22-10-2022
Authority
Authority Name Directorate Of Health Services
Work Description Supply Of Blood Bank Equipments Supply Of Blood Bank Equipments , Rh / Slide Viewing Box , Rh / Slide Viewing Box: For Viewing Of Agglutinationon Slides Light Source : Cfl Power Supply : 230V Ac , Laminar Flow Bench Type , Laminar Flow Bench Type: Type : Horizontal Work Bench Size: 3 X 2 X 2 Ft Classification: Class 100 Main Filter : Minipleat Hepa, Particle Retention Size : Up To 0.3 Micron, Efficiency : 99.999% Pre Filter: Particle Retention Size : Up To 10 Micron, Efficiency: 98% Work Table: Ss 304 Cabinet:Gi Powdercoated Uv Light: Uv Lamp Of Suitable Length Illumination : Fl Lamp Of Suitable Length Switches : On / Off For Blower, Uv, Fl Pressure Gauge :Inclined Liquid Column Manometer Pet Cock : Ss Petcock For Air / Gas Front Door: Foldable Polycarbonate Sheet Wheels : Castor Wheels Supply : 220-230 Volts Ac , Gel Card Centrifuge With Incubator For Cross Matching , Gel Card Centrifuge:-1. Capacity A. Swing Out Rotor Should Accommodate 12 Or Morer Standard Gel Cards. 2. Max Speed Of The Centrifuge Should Be 1600 10 Rpm 3. Max Rcf Should Be 279 1 % G 4. Should Have Audio Visual Alarms For Imbalance, End Of Cycle And Any Other Errors 5. Should Have Single Hand Rotor Removal For Cleaning 6. Should Have Lcd Display With Touch Key Pad 7. Motor Should Be Brushless 8. Net Weight Should Be Less Than 20 Kg 9. Power Supply Should Be 220-240 Volts, 50 Hz, Single Phasegel Card Incubator:-1. Incubator Should Accommodate 12 Or More Gel Cards And 12 Or More Test Tubes Simultaneously 2. Should Maintain Temperature At 37°C 1°C 3. Time Limit Adjustable Up To 60 Minutes 4. Should Have Programs To Adjust Incubation Temperature & Time As Specified By Gel Card Supplier 5. Should Have Audio Visual Alarms For High / Low Temperature And End Of Cycle 6. Should Have Auto Pop-Up Card Mechanism For Card Removal, When Lid Is Opened 7. Should Have Lcd Display With Touch Key Pad 8. Power Supply: 220-240 Volts, 50 Hz, Single Phase , Digital Haemoglobin Meter With Disposable Cuvettes , Digital Haemoglobin Meter With Disposable Cuvettes:Principle : Absorbance Measurement Of Whole Blood At An Hb / Hb02 Isobestic Point; Dual Wavelengths ( 506 Nm A Nd 880 Nm ) For Hb Measurement And Turbidity Compensation Calibration : Factory Calibrated Against The Icsh Reference Method; Needs No Further Calibration Sa Mple Material : Capillary, Venous Or Arterial Whole Blood Measurement Range : 0 -25.6 G / Dl ( 0-256 G / L, 0-15.9 Mmol / L ) Results :3 Seconds Sample Volume Rv Lo ?L Dimensions: 140X70 X160 Mm Weight : 500 G With Batteries Installed Storage Temp : Analyzer: 0-50 °C Microcuvettes : 10-40 °C. For Unopened Vials, The Storage Temperature Ca N Be Extendeddown To -18 °C And Up To +50 °C For A Period Of Maximum 6 Weeks. Operating Temp : 10-40 °C Power : Ac Adapter Or 4 Aa Batteries Interface: For Printer Quality Control: Built-In Selftest, Optional : Liquid Controls Cuvettes :- Std Pack : 200 Nos , Blood Donor Couch ( Fully Automatic ) , Blood Donor Couch ( Fully Automatic ) :Technicaldata Height : 620 - 820 Mm Seat Width : 680 Mm Profile Length : 2010 Mm Back Rest Adjustment: O Degree - 54 Degree Leg Rest Adjustment: O Degree - 60 Degree Trendelenburgposition: -15 Degree Castor Wheels : Fouroo Mm Lockable Wheels Voltage: 230V ± 100% , Blood Transportation Box Portable , Blood Transportation Box Portable:Capacity: 25 L Cold Life: When Ambient Temperature Is Below +30°C, It Can Maintain +2 To +Sc For About 10 Hours If Kept In Closed Condition.
Basic Detail
Tender No C/3085/2019/THQHOTP
Bidding Type Tender
Location
City Palakkad
State Kerala
Key Dates
Publish Date 12 Oct 2022
Submission Date 22 Oct 2022
Open Date 26 Oct 2022
Finance
Tender Value 13.60 Lakhs
Tender Fee 2720
EMD 13600
Exemption Not Available
Document List
4966b53c-775d-4c4e-b049-b16b97d8548a.html
Agreement.pdf
BOQ_732091.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 12, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 22, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 26, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

4966b53c-775d-4c4e-b049-b16b97d8548a.html

pdf

Agreement.pdf

xls

BOQ_732091.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail