Tender For Repair/Replacement Of Unsv Points Of Eot Cranes/ Lifts/ Eot Cranes/ Maintenance Of Dg Sets, Fire Fighting Equipment, Street Light Perimeter Light, Flood Light At Dmrl, Rcma And Atc Devatallagutta At Kanchanbagh, Hyderabad, hyderabad-Telangana

Military Engineer Services-MES has published Tender For Repair/Replacement Of Unsv Points Of Eot Cranes/ Lifts/ Eot Cranes/ Maintenance Of Dg Sets, Fire Fighting Equipment, Street Light Perimeter Light, Flood Light At Dmrl, Rcma And Atc Devatallagutta At Kanchanbagh, Hyderabad. Submission Date for this Tender is 05-11-2022. Cranes Tenders in hyderabad Telangana. Bidders can get complete Tender details and download the document.




Tender Notice

34318355
Corrigendum : Tender For Repair/Replacement Of Unsv Points Of Eot Cranes/ Lifts/ Eot Cranes/ Maintenance Of Dg Sets, Fire Fighting Equipment, Street Light Perimeter Light, Flood Light At Dmrl, Rcma And Atc Devatallagutta At Kanchanbagh, Hyderabad
Open Tender
Indian
Telangana
hyderabad
05-11-2022

Tender Details

Repair / Replacement Of Unsv Points Of Eot Cranes / Lifts / Eot Cranes / Maintenance Of Dg Sets, Fire Fighting Equipment, Street Light Perimeter Light, Flood Light At Dmrl, Rcma And Atc Devatallagutta At Kanchanbagh, Hyderabad

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 29-Oct-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 05-11-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 96000.0 /-
Tender Value
INR 48 Lakhs /-

BOQ Items

Name of Work: REPAIR/ REPLACEMENT OF UNSV POINTS OF EOT CRANES /LIFTS/ EOT CRANES/ MAINTENANCE OF DG SETS, FIRE FIGHTING EQUIPMENT, STREET LIGHT PERIMETER LIGHT,FLOOD LIGHTAT DMRL, RCMA AND ATC DEVATALLAGUTTA AT KANCHANBAGH, HYDERABAD.
Sl. No. Item Description
1Periodical examination, normal and routine maintenance including cleaning of all parts and carrying out corrrective maintenance for trouble free working repairs and replacement of spares in place of old unserviceable items including greasing of EOT/HOT cranes of any make and model as available at site for the following capacities :-
2EOT Crane of 15 to 20 Ton capacity -04 Nos
3EOT Crane of 10 to 15 ton capacity -03 Nos
4EOT Crane of 5 to 10ton capacity-02 Nos
5EOT Craneupto 5 ton capacity- 18 Nos (two No at ATC Devatalagutta)
6HOT Crane of upto 5 ton capacity -01 No Note for srl item Nos.1.01 to 1.05:- Supply only spares required will be measured and paid separately under relevant items. Fixing element is deemed to be included in the quoted rate.
7Conducting of load and deflection test for the EOT and HOT cranes of following capacities and submitting the test report to Engineer-in-Charge.
85 Ton to 10 Ton
9Above 10 Ton & upto 20 Ton
10Above 20 Ton & upto 25 Ton Note for itemNo 2.01 to 2.03:- (a)The required loads are to be arranged by the contractor under his own arrangements includingtransporting to and fro the site without any extra cost to the department. (b) Crane testing is to be carried out by the authorised inspector as per factory act. and the test certificate duly signed by authorised inspector shall be submited to Engr in chagre.
11Supply only Gear Oil of suitable for crane gear assembly. Make:- Servo/Castrol or equivalent.
12supply only Power Contactor 32 to 40 Amps type with 110 Volt coil voltage, three phase.
13Supply only Power Contactor 40 to 70 Amps type with 110 Volt coil voltage, three phase.
14Supply only spare kit for 32 to 40 Amps contactor
15Supply only spare kit for 60 to 70 Amps contactor
16Supply only push button of any type, Make : L&T/GE.
17Supply onlyFlexible geared coupling of any type/size
18Supply onlyBimetal over load relays for contactors Make for srl item No. 9 & 10 : BCH/L&T/C&S/Telemech.
19Supply only push button assembly pendent type complete with all accessories including support hanging wire suitable for 5 Ton to 10 Ton, Make : L&T/GE/Cranex.
20Supply onlyof 1.5 sqmm 12 core Copper conductor cable PVC insulated & PVC sheathed flexible multistranded 1100 volts grade with in suitable withPVC conduit with clamps to fix on wall/railing complete as per site requirnment
21Supply only 2.5 Sqmm, 10 core Copper conductor cable PVC insulated & PVC sheathed flexible multistranded 1100 volts grade withPVC conduit with clamps to fix on wall/railing complete as per site requirnment
22Supply only 6 Sqmm, 8 core copper conductor cable PVC insulated & PVC sheathed flexible multistranded 1100 volts grade withPVC conduit with clamps to fix on wall/railing complete as per site requirnment
23Supply only 10 Sqmm, 6 core Copper conductor cable PVC insulated & PVC sheathed flexible multistranded 1100 volts grade.withPVC conduit with clamps to fix on wall/railing complete as per site requirnment Make:- Plaza/Polycab/Finecab/Finolex/Havells.
24Supply only thruster break oil for hydralic thruster break for long/cross travel/Hoist, Make : Servo/IOC/Bharat.
25Supply only steel wire rope flexible type 6 sqmm for pendent push button box with necessary clamps/clips etc.
26Supply only electro magnetic break with break drum for break disk or break coil of any size/type . Make:- BCH/Speed-O-Control or equivalent
27Supply only Main Hoist steel wire rope (as per existing size) suitable to 10 Ton EOT crane of adequate length and size including accessories.
28Supply only Main Hoist steel wire rope (as per existing size) suitable to 5 Ton EOT crane of adequate length and size including accessories.
29Material and labour for taking the gear box mechanism with necessary equipments carefully without any damaging and taking out to the authorised workshop/OEM serivice center if necessary or repair/replacement of gear oil, oil seal, pinion, reduction pinion, main gear, seconday reduction gear, shaft, bearing, coupling and other spares as required for proper functioning and refixing the same in its original position making all connections testing all parameters like CT & LT suitable for cranes up to 10 Ton and complete all as specified and directed. Note : Transportation to and from the site and the cost for the same is deemed to be included in quoted rate.
30All as per item No. 21 here-in-before but for 15 to 20 Ton capacity crane
31Material and labour for taking down wheel set carefully using hydralic jack without any damaging and taking out to the authorised workshop/OEM serivice center if necessary or repair/replacement of Bearing, pinion, wheel teeth to be make for grip and other spares as required for proper functioning and apply greasing whereever required parts assembling the complete wheel set with connected item suitable for 3 ton to 10 crane and complete all as directed.
32All as per item No. 23 here-in-before but for 15 to 20 Ton capacity crane
33Supply and fix in repairs VVVF drive of crane upto 5 ton capacity drie should be suitable for the existing crane incluidng removing the unserviceable VFD drive complete all as directed.
34All as per item No. 25 here-in-before but for 5 to 10 Ton capacity crane
35Supply and fix in repairs VVVF drive control card of crane upto 10 ton capacity drive control card should be suitable for the existing crane incluidng removing the unserviceable VFD drive control card complete all as directed.
36Conducting of load and deflection test for the EOT and HOT cranes of 10 Tonupto to 25 Ton capacity crane capacities and submitting the test report to Engineer-in-Charge.
37Renewal of burnt out control wiring for 5 to 25 Ton crane with suitable size of copper cable and replacement of connectors, lugs, fuses etc and testing complete all as directed.
38Removing the existing burnt out flame proof main switch and supply and fix flame proof main switch 32 Amps, TP&N, 415 volts with necessary connections complete all as directed.
39Rewinding of Thruster motor of crane upto 25 Ton capacity with super enamelled copper conductor of same existing guage complete all as directed.
40Supply & fix HRC fuse 16A with fuse carrier completeincluding removing the unserviceable HRC fuse complete all as directed. Make : GE/L&T/BCH.
41Supply & fix HRC fuse 63A with fuse carrier complete including removing the unserviceable HRC fuse complete all as directed Make : GE/L&T/BCH.
42Periodical maintenance by the representative of concerned company each month of various Fire Alarm systems including checking, testing, cleaning of Smoke Detectors, Heat Detectors, manual call points, Hooters, Sirens etc.. by carrying out preventive Maintenance and corrective Maintenance for trouble free and efficient functioning of entire system, replacement of the accessories connected to the Fire Alarm systems for the buildings at Main building , New admin& ETC The work is to be carried outall as directed. Note : Spares if any required shall be measured and paid under the relevent items of schedule. and labour elment is deemed to be included in rate quoted.
43Supply, installation, testing including removing the unserviceable old following spares required for the efficient functioning of the Conventional Fire Alarm systems :-
44Photo electric (optical)Smoke detector with isolator base. Make : Godrej-VDS/Apollo/System Sensor
45Heat detector with isolator base. Make : Godrej-VDS/Apollo/System Sensor
46Ionization Smoke detector with base. Make : Godrej-VDS/Apollo/System Sensor
47Electronic Hooter Make : GST/Agni/System Sensor
48Manual call point . Make : Godrej-VDS/Agni/System Sensor/Securico
49Response indicator Make : Godrej-VDS/Agni/Securico
50Hooter . Make : Godrej-VDS/Agni/Securico
51Maintenance free Battery 12V, 7AH Make : Exide/Amco
52Manual call point switches. Make : Agni/Honeywell.
53Manual call point glass. Make : Agni/GST.
5424 volts potential free relay. Make : L&T/Siemens/Omran
55Siren controller contactor . Make : L&T / SIEMENS / GE
56Assorted Fuses. Make : GE/FTC.
57Supply, installation, testing, complete including removing the old unserviceable following spares required for the efficient functioning of the Analogue Addressable Fire Alarm systems :-
58Photo electric (optical)Smoke detector with isolator base. Make :Godrej-VDS/ Apollo/Morley IAS/GST
59Ionization Smoke detector with base Make : Godrej-VDS/Apollo/Morley IAS/GST
60Heat detector. Make : Godrej-VDS/Apollo/Morley/GST
61Electronic Hooter Make : Apollo/Morley IAS/GST
62Manual call point Make : Apollo/Morley IAS/GST
63Fault Isolators Make : Apollo/Morley IAS/GST
64Loop driver card Make : Apollo/Morley IAS/GST
65Data/Ribbon cable with connector. Make : Apollo/GST.
66M&L for 1.5 sqmm, 2 core copper conductor multistranded PVC insulated, sheathed FRLS cable conforming to IS specification with and including PVC conduit of suitable size suitable for Fire Alarm system complete including removing the unserviceable cable complete all as directed. Make : Godrej-VDS/FINOLEX/ORBIT/NEOLEX
67M&L for 2.5 sqmm, 2 core copper conductor multistranded PVC insulated, sheathed FRLS cable conforming to IS specification suitable with and including PVC conduit of suitable for Fire Alarm system complete including removing the unserviceable cable complete all as directed. Make : Godrej-VDS/FINOLEX/ORBIT/NEOLEX
68M&L for PVC conduit 15mm dia medium grade FRLS type suitable for Fire Alarm/street light poles from Looping box to GI bracketsystem including clamps and removing the unserviceable PVC conduit complete all as directed. Make : Godrej-VDS/FINOLEX/ORBIT/NEOLEX
69S&F addressable 1/2 loop microprocessor based master fire alarm panel with its own battery charger, battery for 24 hours backup including testing and removing the unserviceable fire alarm panel, complete all as directed. Make : Boss/Honeywell/Agni.
70Supplu& fix in replacementthe sign board ofAssistant garrison Engineer E/M-I GE(I) R&D kanchanbagh, Military Engineer Services with LOGO of (MES) sign Board Details: 3.5ft x5.5ft ACP Panel (aluminium composite panel) 3mm thickness white colour or grey colour acrylic litters will fix on panel.letters in Aerylic 6mm or 8mm thickness computerised script CNC laser cutting letters in imported Aerylic.
71M&L for Power supply and Battery charging board for 4 zone micro processor based Fire Alarm panel including removing the unserviceable battery charging board complete all as directed. Make : Ravel/GST/Agni
72M&L for power supply and Battery charging board for 8 zone micro processor based Fire Alarm system including removing the unserviceable battery chargingboard complete all as directed. Make : Ravel/GST/Agni
73M&L for display and control mother board for 4 zone micro processor based Fire Alarm system complete including removing the unserviceable display and control board complete all as directed. Make : Ravel/GST/Agni
74M&L for display and control mother board for 8 zone micro processor based Fire Alarm panel complete including removing the unserviceable display and control board complete all as directed. Make : P100/GST/Agni
75Suppy and fixing in repair 4 zone Fire Alarm panel complete including removing the unserviceable panel complete all as directed. Make : Ravel/GST/Agni
76Suppy and fixing in repair 8 zone Fire Alarm panel complete including removing the unserviceable panel complete all as directed. Make : Ravel/GST/Agni
77Disconnecting and removing of unserviceable levelling/ stopping/ slowing sensors and Supply and Fix of new levelling/ stopping/ slowing sensor complete all as directed.
78Disconnecting and removing of unserviceable Mechanical switches stopping/ slowing and Supply and Fix new Mechanical switches stopping/ slowing complete all as directed.
79Disconnecting and removing of unserviceable Break coil and Supply and Fix of new Break coil complete all as directed.
80Maintenance of DG set and carrying out ‘B’ check and replacement of ‘B’ check kit filters such as Oil filter, by pass filter, fuel filter,CR element and CR plates complete with ‘O’ rings and draining of Engine oil and topping up with the new engine oil complete testing all as specified and directed by the Engr-in-Charge for the following capacity DG sets:- Note :- 1. Engine oil shall be measured and paid separately. 2. B Cheak to be carried out every after 250 hrs run or 6 months whichever is earlier. Make: KIRLOSKER/ CUMINS /GREAVES
8120 KVA DG Set
8240 KVA DG Set
83125 KVA DG Set
84250 KVA DG Set
85320 KVA DG Set
86400 KVA DG Set
87500 KVA DG Set
88625 KVA DG Set
89Renewal of unserviceable batteries with maintenance free batteries of 180 AH, 12V including connecting to DG set complete all as directed. Make:-EXIDE/ AMARON
90Attending thebreakdown of any capacity/make DG Sets, AMF Panels, by Technician & helper for checking all components and identifying and rectifying the faults and submission of test report to concerned JE complete all as directed. Note:- Spare Parts for rectifying the fault shall be measured and paid seperately.
91S&F in repairsautomatic voltage regulator (AVR) upto 40 KVA DG set and testing complete all as directed. Make:- As per OEM make.
92S&F in repairsautomatic voltage regulator (AVR) 125 to 250 KVA DG set and testing complete all as directed. Make:- As per OEM make.
93S&F in repairsautomatic voltage regulator (AVR) 320KVA to 630 KVA DG set and testing complete all as directed. Make:- As per OEM make.
94Dismantling of exhaust pipe of the DG set by unscrewing nuts and bolts and taking down the pipe with muffler, removing the burnt out asbestos rope and well wrapping with new aluminium metal cladding with glass wool including cleaning the silencer, and fixing the same in its original position complete all as directedfor the following capacity DG Sets.
95125KV to 250 KVA DG set.
96320 KV to 630 KVA DG set.
97Disconnecting all electrical connections from the unserviceable self starter of any make/ capacity model 24 volts, 180 /200 AH and taking down the self starter and transporting to civil workshop for carrying out repairs, complete overhauling the system including replacing the unserviceable parts such as bearing, carbon brushes, clutch plates etc refixing the self starter in its original position, testing and commissioning complete all as directed. Note:- Supply only Armature coil, field coil shall be measured and paid separately under relevant items of this Schedule fixing included inthis item.
98Supply only Armature coil for self starter of any make of any capacity and of any model 24 Volts, 180/200 AH complete all as directed.
99Supply only of field coil for self starter of any make, any capacity and any model 24 Volts, 180 /200AH complete all as directed .
100Disconnecting all electrical connections from the unserviceable self starter of any make/capacity/model 12 volts, 180, 200 AH and taking down the self starter and transporting to civil workshop for carrying out repairs, complete overhauling the system including replacing the unserviceable parts bearing, carbon brushes, clutch plates etc refixing the self starter in its original position, testing and commissioning complete all as directed. Note:- Supply of Armature coil, field coil shall be measured & paid separately under relevant items of this Schedule.
101Supply only Armature coil for self starter of any make, any capacity and any model 12 Volts, 180/200 AH complete all as directed.
102Supply only of field coil for self starter of any make, any capacity and any model 12 Volts, 180/200 AH complete all as directed.
103Disconnecting the oil cooler of 110 KVA to 250 KVA DG set of any make/ model from the existing locations duly removing of all mechanical connections and taking down the same for complete servicing opening the parts and cleaning thoroughly by using suitable cleaning material and acid and reassembling and refixing in its original position, testing and commissioning complete all as directed.
104S&F in repairs air cleaning element inner and outer with necessary ‘O’ rings for the DG sets of following capacities as that of existing make and model complete all as directed.
105Upto 40KVA DG Set
106125 KVA to 250 KVA DG Set
107320 KVA to 630 KVADG Set
108Disconnecting all the incoming and outgoing rubber hoses and draining out the water from the choked radiator assembly of the existing make and model and of various capacities of DG sets and taking down the radiator assembly by unscrewing all mechanical connections from the existing mounting, transporting the same to civil workshop for carrying out servicing, opening the top and bottom covers ofradiator assembly cleaning thoroughly the chocked pipe of the radiator by using detergent, lime caustic soda, cotton etc., cleaning of all the deposited sediments in the pipes/tubes including arresting of leakage by means of soldering, brazing and transporting back to site and refixing the same in its original position with suitable size nuts, bolts and washers etc., complete all as directed for the following DG sets:-
109Upto 40 KVA DG Set
110125 KVA to 250 KVA DG Set
111320 KVA to 630 KVADG Set
112Renewal of battery cable leads of copper conductorwith brass lugs terminal, for the 12V 180 /200 AHbatteries for self stater as that of existing size and length complete all as directed.
113S&F in repairsautomatic cut off Battery Charger suitable for 110V,up to 40 Amp Battery complete all as directed . Make :SMPS/ Phonix or
114S&Fin repairs automatic cut off Battery Charger suitable for 12/24 V, up to 40 Amp Battery complete all as directed. Make SMPS/ Phonix
115Renewal of "V" belts for the following capacity DG sets as perexisting size and model complete all as directed. Make:- FENNER/ DUNLOP
116Upto 40KVA DG Set
117125 KVA to 250 KVA DG Set
118320 KVA to 630 KVADG Set
119Renewal of existing unserviceable water temperature gaugefor the DG set of any description complete all as directed.
120Renewal of existing unserviceable lubricant oil temperature guagefor the DG set of any capacity complete all as directed.
121Renewal of existing unserviceable oil pressure gaugefor the DG SET of any capacity complete all as directed .
122Renewal of unserviceable Solenoid switchfor DG set of any make and any capacity complete all as directed. Make :- RUSTON/ GREAVES COTTON/Kirloskar/CUMMINS.
123Supply and filling the new engine oil 15W/40 for toping up, upto the required level complete all as directed. Make :- CASTROL/ INDIAN OIL/ SERVO
124Drain out the fuel from the fuel tank of DG set of capacity 600 Ltrs and above and keeping it in separate container safely, disconnecting all the fuel lines and other mechanical connections and taking out the fuel tank for cleaning, internally and externally by removing all the accumulated dirt/ sediment, leak testing the tank and welding/ brazing including one coat ofsynthetic enamel paint, refixing the tank in its original position, replacing the drain plug and PVC pipe, calibrating the fuel tank, refilling the drained out fuel back into the tank and marking of liters in gauge and provision of locking arrangements complete all as directed.
125Removing of defective engine oil control pressure switch and supply & fix new engine oil control pressure switch suitable for up to 250 KVA setcomplete all as directed. Make Kirloskar- Cummins
126Renewal of defective wiring with copper wire of existing size including replacement of electrical/ electronic parts of AMF panel & DG Set, complete all as directed. Note: - Supply only Electrical/ Electronic spare parts shall be measured and paid separately.
127Auxiliary contactor 240 Volts,(2NO.+2NC).
128ON and OFF delay timer 240 V AC and 24 V DC.
129Over load relay.
130ML - 4 contactor.
131Earth Fault Relay IRII-31-E1-WD Suitable for 250 V, AC. Make: C&S
132Single phase preventer
133Auxiliary Relays 24Volts / 6A
134PLC based AMF relay unit
135Low lube oil safety switch
136Booster Relay 24Volts / 10A
137Battery charger 24 V /10A panel mounting type
138Coolant temparature sensor
139LED indicating Lamp
140Push buttons
141Selector switches
142Removing the defective charging dynamo of capacity 24 Volt DC any make, model, any capacity and opening it, by removing all nuts and bolts, cleaning with necessary cleaning agent and overhauling lubricating of the same replacing of armature, field coils reconnecting the same, refixing back, in original position testing and commissioning complete all as directed.
143Supply & topping up ofInhibitor corrosion (coolant additive concentrate) as required(TVS Make) complete all as directed.
144Supply and topping up of distilled water suitable for lead acid batteries of 12 volts complete all as directed.
145Dismantling/taking out old unserviceable alternator (charging of battery) and taking out worn out spares such as ammeter, brush and field winding and repair the same by replacing ammeter, brush and rewinding of field coil with same guage of copper wire and testing complete all as directed .
146Calibration of PT pump and replacement of PT Pump kit, gear gasket, etc whichever is required for smooth functioning of DG Set complete all as directed.
147Calibration of injectors by replacing injector cup, barrel plunger for smooth functioning of engine, testing completeall asdirected .
148S&F PVC insulated, heavy duty, unshealted ,multi Stranded Copper Cable of35 Sqmm single corewith suitable size lugs crimpedon both side complete all as directed.
149S&F Flexible Bellow suitableup to 125 KVA Gen Set. Make as per OEM
150Disconnecting of alternator from 125 KVA to 250 KVA capacity DG set, after Disconnecting from Generaror shifting to civil workshop, taking out burnt out winding from Stator & Rotator, Cleaning thoroughly and rewinding the stator,rotor with suitable guage of super enameled copper conductor similar to that of existing size including necessary insulating material varnishing, heating,replacingbearings in rotor and stator side, reassembling of alternator, bringing back to the site refixing and installation over foundation with proper alignment, testing and commissiong complete all as directed. Note :- cost oftaking up and down from the site to workshop vice versa with vehicle and necessarylabour shall bedeemed to be included in quoted rates.
151All as per item No.87 but for 320KVA to 630 KVA DG Set
152Supply, fix and test run theFly-wheel Ringof existing model,size suitable for DG set of capacity 63 to 250 KVA including taking down old unserviceble fly wheel ring complete all as directed.
153Supply and fixin repairs Stanguard AutoTransfer switch (ATS) with enclouser of capacity 200 Amp 4 pole with automatic/manual with complete protectionall accessorices complete all as directed.
154Supply, Fix & test run the DG set after replacing Diesel feeder Pumpof existing model,sizesuitable to DG Set of capacity upto 400 KVA including taking down old unserviceable disel feeder pump complete all asdirected.
155Supply, Fix & test run the DG set after replacing Diesel feeder Pumpof existing model,sizesuitable to DG Set of capacity 500 to 630 KVA including taking down old unserviceable disel feeder pump complete all asdirected.
156M&L for removing old rusted painted from complete DG Set surfaces ofthe DG Set of capacity upto125 KVA complete with one coat of Primer andtwo coats ofspray painting with existing colour paint synthetic enamel type including writing Ser No of DG set complete all as specified and directed.
157Renewal of 3 pole 415 volts 50Hz Power Contractors of the following capacity including Connecting & testing complete all as directed by engineer-in Charge.
158MNX 25 Contractor or its Equivalent
159MNX 40Contractor or its Equivalent
160S&F Repair/ replacement of timer 0 to 60 mincomplete all as directed.
161Comprehensive Annual Maintenance including rectification of any faults of various Fire Alarm Systems installed at DMRL, RCMA and AT devatalaguttaareas including checking, testing, cleaning of Smoke Detectors, Heat Detectors, Beam Masters, Hooters, Manual Call Points, spirit bulbs etc. by carrying out preventive Maintenance and Corrective Maintenance rectifying defects in existing system and making the entire system trouble free and efficient functioning with all accessories connected to the Fire Alarm systems complete all as directed.
162Note: (i)Spares if any required shall be measured and paid under the relevant items of schedule and cost of labour/Fire fighting Technician/ Engineer, element like Tools/Eqpt, cleaning agents etc are deemed to be included in the quoted rate. (ii)The preventive maintenance schedule shall be as follows:- (a) MONTHLY - Checking of all cards (control card, zone card, fail card, charger card etc) in control panel for their healthly working condition. Testing of all zones by checking smoke detectors at random with smoke testing of Hooters and MCPs. (b) QUARTERLY - cleaning of all smoke detectors, heat detectors, response indicators, hooters, MCPs and Beam mastars and testing of all smoke detectors with smoke and heat detectors with heat. (iii)Service report is to be generated for the above monthly and quarterly maintenance for all the systems andsubmitting to Engr-in- Charge. (iv) Brakedown should be rectified as and when the system brakes down.
163Testing and Refilling of Foam type Fire Extinguisher 9 Ltrs. Capacity complete fully charged gunmetal cap heavy inner container with wall mounting brackets etc. confirming to IS: 933. Make: Safex / Geo /Konex
164Testing and Refilling of Dry Chemical Powder type Fire Extinguisher 5 Kg. Capacity powder and CO2 gas catridge of 120 gms. Capacity confirming to IS: 2171.
165Testing and Refilling of Dry Chemical Powder type Fire Extinguisher 9 Kg. Capacity powder and CO2 gas catridge of 180 gms. Capacity confirming to IS: 2171.
166Testing and Refilling of Carbon – Di – Oxide type Fire Extinguisher 4. 5 Kg. Capacity CO2 gas confirming to IS: 2878
167Taking down old unserviceable hydrant valve and Supply, Installation, Testing and Commissioning of Single Headed Hydrant valve confirming to IS 5290 with ISI mark of size 63 mm dia oblique type with instantaneous hose coupling adaptor etc. with all neceesary fittng materials complete required.
168Taking down old unserviceable hydrant hose pipe and Supply, Installation, Testing and Commissioningof Hydrant hose pipe, 63 mm dia and 2x15 mtrs long RRL type with Gunmetal 63 mm size male coupling at one end andfemale coupling at the other end.It should with stand a burtsting pressure of 450 psi, rot proofed, with ISI mark. Hose shall comply to IS 636
169Taking down old unserviceable hose reel pipe and Supply, Installation, Testing and Commissioning of Fire Hose Reel pipe 20 mm dia. X 30 mtr. Long, high pressure with 5 mm out let GM nozzle with shut off valve(IS: 884 - 1969) includes stop cock and chromium plated nozzle with all neceesary fixing materials complete all as directed.
170S&F in repairs sprinkler bulb Spirit type 60 to 70 degree temperature fusible range suitablefor fire fighting sprinkler system complete all as directed.
171M&L for Scrapping of old existing paint of pipe lines for Fire fighting system of any sizes and applying two coats of enemel paint to match with the existing shade complete all as directed. Note - Rate quoted shall be deemed to include cost of Paint & tools. Make - ASIAN/SHALIMAR/NEROLAC
172Scrapping of old existing paint of Fire cabinet (inside & outside) for Fire fighting system of any sizes and applying two coats of Red postal colour enemel paint. Note -Rate quoted shall be deemed to be include rates of Paint & tools. Make- ASIAN/SHALIMAR/NEROLAC
173M&L for rewinding of the electric motor of 60 HP capacity duly disconnecting and taking down electric motor from the existing position and inspecting the same, transporting to workshop for repairs and bringing back. Cutting and removing the burnt out winding conductors rewinding the same with same gauge and weight of insulated super enamelled copper conductor and providing cotton insulated sleeves, varnishing, drying, refixing in position checking the alignment along with pump set connecting up with the electrical system, testing and commissioning complete all as directed.
174Repair and servicing of 60 to 100 HP Fire Fighting Pump and motor including all connecting parts by replacing gland, greasing & oiling and rectification of alignment of pump and motor, cleaning the carbon from the electrical connections and commissioning complete all as directed.
175Repair and servicing of 7.5 to 12.5 HP Fire Fighting Pump and motor including all connecting partsby replacing gland, greasing & oiling and rectification of alignment of pump and motor, cleaning the carbon from the electrical connections and commissioning complete all as directed.
176S&F of following parts of Fire fighting system with all necessary electrical connection with lugs of any size and testing commissioing including taking down the same complete all as directed.
177Contactor for fire Panel MNX 70 3Pole Make : L&T/C&S
178Electronic Timers Type ET 100 ML-6, 9-30 Sec, 415V, 50 Hz Make : L&T/C&S
179High Pressure control guage 02-14 Bar, 0-55 PSI , KP-36 Make : Denfoss
180S&F DWC pipe 40 mm HDPE double wall corrugated pipe cable ducting ,underground electrical conduits complete all as specified and directed.
181S&F in replacementPVC Junction box of size 250x200x100mm,light weight pole mounting including MCB SP 10Amps including necessary busbar MCB mounting arrangement and necessary connector for looping in and looping out cable connection and suitable glands including taking down old unserviceable junction box complete all as directed. Make :- SINTEX or techno commercially equal in Hensil and C&S
182S&F in repairs GI street lightwith 4 feet mast armfor poles SP-25 to SP-31 as per the site requirements fixing on top of the pole with necessary nuts and bolts including shifting the existing street light from the bracket and connecting up with three core flexible cable by making necessary holes on the poles complete for passing the copper cable concealed in the poleincluding removing of spikes installed on existing pole complete all asdirected.
183Supply and fix in repairs Stanguard ON-LOAD Change over switch of capacity 200 amps to 400 Amp with advance neutral along with sheet steel enclosure/ panelmounted type as per site reqiurement(W/E) , AC23A ,415V, 50Hz, confirming toIS:13947-3 complete all as directed.
184Supply and fix in repairs Stanguard ON-LOAD Change over switch of capacity 800 to 1000 ampswith advance neutral along with sheet steel enclosure/ panelmounted type as per site reqiurement(W/E) , AC23A ,415V, 50Hz, confirming toIS:13947-3 complete all as directed.
185S&F repair LED down light 12 W high colour rendering index (CRI>90) lumien efficacy of 100 Lm/W 2.5 KV voltage surg protection power factor > 0.9 housing made from powder coated die casted aluminium day light (5000K)complete all as specified and directed. Make:- BAJAJ CAT NO. BPSLR12WNW OR EQUIVALENTPhillips/ Jaguar/Shakti
186S&F repairMount LED Bollard light 10W Sturdy Ip 65 LED bollard with excellent light out put through its PMMA window ensuring maximum illumination aspect in surrounding including base foundation and nuts,bolts connectionscomplete all as specified and directed. Make:- Shakti CAT NO SZPGBMX010orHavells CAT NO. 10 W LED 857PSYMTOPPMMAM OR EQUIVALENTPhillips/ Jaguar
187S&F repairMount Coral LED Post top Lamp 40Wdesigned with symmetrical light distrubtion,spun aluminium landscape luminarie with high power LEDs as light source suitable for pole 40/50mm diacomplete all as specified and directed. Make:-Shakti CAT NO SZPGMX0405or HavellsOR EQUIVALENTPhillips/ Jaguar
188Supply & Laying, jointing & testing of XLPE UG LT cables,insulated, PVC sheathed aluminium conductor multi stranded armoured heavy duty 1100 Volt grade laid in trenches/ducts/along poles/through pipe under road etc with new aluminium lugs for the following cable sizes all asdirected. Make: HAVELLS/ UNIVERSAL/ CCI/ GLOSTER/KEI/ POLYCAB/ KEC INTERNATIONAL (RPG)
1896 sqmm 4 core
19010 sqmm 4 core
19116 sqmm 4 core
19225 sqmm 3.5 core
193Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables and getting out in soft/loose soil complete all asdirected.
194Returning, filiing in, including spreading, levelling watering and well ramminginlayers not exceeding 25 cm thick each, using soil complete all as directed.
195Removing excavated surplus soil obtained from excavation to a distance not exceeding 1.5 m above the starting point, complete all as specified.
196S&Fin repairs LED 90 watt street light fitting made up of pressure die cast housing with toughened glass and individual LEDs with street optics and IP 66 protection, 5700K includingfixing to pole/wall with necessary copperwire twin core for connection from source to fitting,nuts, bolts and washers complete all as directed. Make:- Shakti Cat NO SZPSLPM090 or Havells, Model No:- ENDURAOMNIPLUSSL90WLED757SASYTOPC / Wipro Cat par No.LR02-102-XXX-57-G2 or Equivalent in Philips/ Crompton greaves
197S&F in repairs of LED 45watt street light fitting made up of pressure die cast housing with toughened glass and individual LEDs with street optics and IP 66 protection, 6500K includingfixed to pole/wall with necessary copperwire twin core for connection from source to fitting, MS clamp & accessories complete all as directed. Make:- Shakti Cat NO SZPSLPM090 Havells cat partNo: ENDURASUNDOWNSL45WLED765PASYBOPC / Wipro cat part No. LR-02-501-XXX-57-XX or Equivalent in Philips/ Crompton greaves
198S&F in repairs LED street light 60 W secondary optics made in pressure die cast housing and heat shrink in aluminium extrusion and IP 66 protection, 5700K color temperature fixing to the bracket or street light pole with necessary copperwire twin core for connection from source to fitting nuts and bolts as required at site complete all asdirected. Make:-Shakti Cat NO SZPSLPM060or Havells cat partNo: ENDURAOMNIPLUSSL60WLED757SASYTOPC /Wipro Cat part No.LR02-331-XXX-67-XX or Equivalent in Philips/ Crompton greaves
199S&F in repairs LEDstreet light 100 W secondary optics made in pressure die cast housing and heat shrink in aluminium extrusion and IP 66 protection, 5700K color temperature fixing to the bracket or street light pole with necessary copperwire twin core for connection from source to fitting nuts and bolts as required at site complete all as specified and directed. Make:- Shakti Cat NO SZPSLPM100or Havells Model No: ENDURAOMNIPLUSSL100WLED757SASYTOPC / Wipro Cat part No.LR06-311-XXX-67-XX or Equivalent in Philips/ Crompton greaves
200S&Fin repairs LED 250 watt high mast/floodlight fitting made up of pressure die cast housing with toughened glass and individual LEDs withIP 66 protection, 5700K includingfixing to High mass pole/truss with necessary copperwire twin core for connection from source to fittingnuts, bolts and washers complete all as directed. Make Shakti SZCFLPH250or Philips, Model No:- BVP483 LED185 CW SWB PSU GR or Equivalent in Havell"sCrompton greaves
201S&Fin repairs LED 150 watt high mast/floodlight fitting made up of pressure die cast housing with toughened glass and individual LEDs withIP 66 protection, 5700K includingfixing to High mass pole/truss with necessary copperwire twin core for connection from source to fitting nuts, bolts and washers complete all as directed. Make Shakti SZCFLPH150or Philips, Model No:- BVP483 LED185 CW SWB PSU GR or Equivalent in Havell"sCrompton greaves
202S&Fin repairs LED 100 watt high mast/floodlight fitting made up of pressure die cast housing with toughened glass and individual LEDs withIP 66 protection, 5700K includingfixing to High mass pole/truss with necessary copperwire twin core for connection from source to fitting nuts, bolts and washers complete all as directed. Make Shakti SZCFLPH100or Philips, Model No:- BVP483 LED185 CW SWB PSU GR or Equivalent in Havell"sCrompton greaves
203S&Fin repairs LED 120 watt highbay light fitting made up of pressure die cast housing with toughened glass and individual LEDs withIP 66 protection, 5700K includingfixing to High mass pole/truss with necessary copperwire twin core for connection from source to fittingnuts, bolts and washers complete all as directed. Make Shakti SZHHCPX120 orHavells, Model No:- SAUCERGENXHBP120WLED757P90DBOLTG or Equivalent in Philips/ Crompton greaves
204S&Fin repairs LED 150 watt highbay light fiitting made up of pressure die cast housing with toughened glass and individual LEDs withIP 66 protection, 5700K includingfixing to High mass pole/truss with necessary copperwire twin core for connection from source to fitting nuts, bolts and washers complete all as directed. Make Shakti SZHHCPX150 Havells, Model No:- SAUCERGENXHBP150WLED857PNBBORL or Equivalent in Philips/ Crompton greaves
205Re-stringing, tightening and fixing in position, the existing OH ACSR conductor LT Line phase with neutral and earth wire 230V, 2/3 wire by loosening and taking down existing binding wire from the insulator of any size of ACSR conductor and bringing it to required sag including provision of new binding wire and tightening of cross arms on each pole and requiredtrimming of tree branches Note: 1. Span length (any No of wires)of conductor shall be measured as one RM. 2. Unit rate quoted by the contractor shall be deemed to include for cutting and trimming branches of the trees coming in contact with ACSR conductorand separators as directed.
206Cutting/ trimming / punning tree branches overhanging or interfering or obstructing electrical pole or street lightsin such a way that theclearance between Street light pole and tree branches should not be less than 3 mtrs around the Pole/Fitting complete all as directed. Note: Quoted rate is deemed toinclude necessary hydraulic ladder arrangement and tree cutting machine and tools required at site.)
207M&L for scrapping down and removing of old deteriorated paint from steel tubular poles LT preparing surface for painting and applying black & yellow paint strips of 30 cms each upto 1.5 m above the PCC and applying one coat of red oxide and two coats of aluminium paint for the remaining height of pole including MS clamps, GI bracket, fittings etc and marking of pole No, 2m above the PCC muff, letter shall not be more than 6 cm height with 16 cm dia circle around the marked No. complete all as directed. Note : Quoted rate is deemed to include removal of any type of boards, direction plates etc and refixing the same after painting, in its original position with necessary bolts and nuts.
208S&F in repairs automatic timer switch distribution board, factory assembled in powder coated sheet steel enclosure, 3Phase, suitable upto 12KW load, comprising of 32 Amps, 3 Pole, MCB TPN, 40A power contactor and 415V digital timer switch for controlling street lights outdoor type,including angle iron base and stand for fixing the panel with suitable PCC foundation as per site requirement . Make: SWADEEP Havells Cat Part: IHXSS01060 or equivalent in L&T/Legrand/Indo Asian
209S&F in repairsautomatic timer switch distribution board, factory assembled in powder coated sheet steel enclosure, suitable for upto 5KW load single phase comprising of 25 Amps SP MCB, 25A power contactor and 230V digital timer switch for controlling street lights,including angle iron base and stand for fixing the panel with suitable PCC foundation as per site requirement . Make: SWDEEP Havells Cat Part No : IHXTS09120 or equivalent in L&T/Legrand/Indo Asian Note:- Rate quoted shall be inclusive of necessary excavation & earth work and PCC foundation.
210S&F in repairspolymer white , Grey or Green Pin type shakle type orany type LT as per site requrment insulator of 1.1KV grade including one galvanised mild steel strap washers, bolts, washers and nuts complete all as directed. Make - RashtriyaElectrical/ BHEL/ National
211S&F, in repairs stay assembly complete with accessories as shown in electrical plate No.1 of SSR part I including loop type insulator, stay clamps, stay strands, excavation & earthwork and PCC work complete all as specified and directed. Note:- Rate quoted shall be inclusive of necessary excavation & earthwork and concrete as required.
212M&L for paintingthe pole number on the LT/Street Light pole in circular shape with black synthetic enamel paint background andwhite synthetic enamel painted letters. Note:- The numbers and words shall be all as directed by the Engineer-in-charge.
213S&F Electronic driverfor 20/25 watts LED security light fittings Make : HAVELLS/BAJAJ/CG or Equivalent
214S&F Electronic driverfor 36/35 watts LED security light fittings Make : HAVELLS/BAJAJ/CG or Equivalent
215S&F Electronic driver for 45/50 watts LED road way/Flood light/post top Make : HAVELLS/BAJAJ/CG or Equivalent
216S&F Electronic driver for 60/70 watts LED road way/Flood light/post top Make :HAVELLS/BAJAJ/CG or Equivalent
217S&F Electronic driver for 90/100 watts LED road way/Flood light/post top Make : HAVELLS/BAJAJ/CG or Equivalent
218S&F Electronic driver suitable for 120watts LED street light/Flood light fittings. Make : HAVELLS/BAJAJ/CG or Equivalent
219S&F Electronic driver suitable for 150watts LED street light/Flood light fittings. Make : HAVELLS/BAJAJ/CG or Equivalent
220M&L for MS plate/sheet plain or cheuered 4.00 mm thick cut to pieces as required and fixed to MS frame work by means of electric arc/gas welding all asdirected and specified. .
221M&L for Preparation of metal surfces of any description, applying two coat of synthetic enamel paint of color as directed by the Engr-in-charge over a coat of red oxide primer complete.
222Supply and spreading of natural, clean, dry, river sand in trenches for cable protection / transformer yard/ two pole structure yardcomplete all as directed. Note:- Punned thickness only shall be measured for payment purpose.
223M&L for laying ofcommon burnt bricks, sub class "B", old size 230 x 115 x 75mm in trenches for cable protection complete all as directed.
224Supply and fix GI tubing 50 mm Tubes, "light grade", galvanised, with all fitting; laid in trenches complete all as directed.