Tender For Spl Repair/Replacement Of Lt/Ht Ug Cable And Other Allied Wks At Morar Cantt, Gwalior, gwalior-Madhya Pradesh

Military Engineer Services-MES has published Tender For Spl Repair/Replacement Of Lt/Ht Ug Cable And Other Allied Wks At Morar Cantt, Gwalior. Submission Date for this Tender is 14-11-2022. LT Cable Tenders in gwalior Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

34305328
Corrigendum : Tender For Spl Repair/Replacement Of Lt/Ht Ug Cable And Other Allied Wks At Morar Cantt, Gwalior
Open Tender
Indian
Madhya Pradesh
gwalior
14-11-2022

Tender Details

Special Repair / Replacement Of Lt / Ht Ug Cable And Other Allied Wks At Morar Cantt, Gwalior

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 25-Oct-2022 Amdt BOQ BOQ 07-11-2022
2 25-Oct-2022 Amdt in tender documents Technical Bid 07-11-2022
3 25-Oct-2022 Postpone_1 Date 07-11-2022
4 07-Nov-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 14-11-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 79260.0 /-
Tender Value
INR 39.63 Lakhs /-

BOQ Items

Name of Work: SPL REPAIR/REPLACEMENT OF LT/HT UG CABLE & OTHER ALLIED WKS AT MORAR CANTT, GWALIOR
Sl. No. Item Description
1Excavation in trenches not exceeding 1.5m wide and not exc. 1.5m depth and getting out in hard/dense soil complete all as specified and directed.
2Excavation in trenches exceeding 1.5m wide and not exc. 1.5m depth and getting out in hard/dense soil complete all as specified and directed.
3Returning, filling, including spreading, leveling, watering and well ramming in layers not exc. 25cmin soft/loose soil complete all as specified and directed.
4Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
5M&L for sand cushioning in trenches for cable protection including consolidation complete all as specified and directed.
6M&L for Sub class "B" bricks laid dry width wise across the line of cable in treanchs as cable protection complete all as specified and directed.
7Dismantling existingPCC & SteelPoles/ struts, any sizeincluding necessary excavation demolition of concreteand removing the old unserviceable rubbish etc complete all as specified and directed.
8Dismantling of cross arms of MS channel or angle iron sections etc complete andsetting aside complete all as specified and directed.
9Dismantling of insulators any type any size complete all as specified and directed.
10Dismantling steel earth wire from existing overhead service feeder etc all as specified and directed.
11Dismantling ACSR conductor ofsize 6/1/2.59 from existing overhead service feeder etc all as specified and directed.
12Dismantling air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism for repair/replacement of broken/worn out components and insulators etc. or carrying to MES store (spare/ components for replacement to be provided free by department) complete all as specified and directed.
13M & L for switch air break gang operated triple pole out door type with drop out switch fuse unit on HT 11 KV 50 cycle AC suitable for current rating upto 200 Amps mechanically operated mounted on insulators (12 Nos epoxy insulators) and frame with operating mechanism worked from ground level with earth switch and including locking arrangement complete all as specified and directed.
14Fixing only of ACSR conductor of any size on existing or new poles complete incl restringing, jointing &binding etc retrieved against above said item complete all as specified and directed.
15Fixing only of cross arm of any size on existing or new poles complete after drilling, cutting, scrabbing & 2 coat of aluminium painting etc retrieved against above said item complete all as specified and directed.
16Supply & Fix HT SFU of 11 kv LBSF panel outdoor complete with, 630-ALoad break switch, 200-AD.O.set, Earth switch,Pvc sleeved copper bus- bar for Incoming, DoorInterlocking mechanism, Tripping mechanism,Epoxy insulator for bus supports, H. V. cable box provided, For end termination at incoming side, End plate ,Provided at outgoing side for end termination etc complete all as specified and directed.
17M & L for lightening arresters expulsion type 11 KV grade complete with all fittings, transmission class, discharge capacity 65 Kilo Amps complete all as specified and directed.
18M & L for cross arms, bracing, supports, clamps and back plated fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as directed inclusive of 2 coats of aluminium paint over a coat of red oxide primer after dismantling old unserviceable cross arms complete all as specified and directed.
19S&F disc type Insulator (single disc assembly) porcelain vitreous, white brown or green 145 mm height and 255 mm dia ball and socket type with tension clamp galvanized iron nutfor conductors working pressure 11000 volt grade complete all as specified and directed.
20S&F Insulator pin type epoxy insulators vitreous, white brown or green including one galvanized mild steel spindle, two galvanized washers and one galvanized iron nutfor conductor working pressure 11000 volt grade complete all as specified and directed.
21M&L for fixing of ACSR conductorsize 6/1/2.59 on existing or new poles complete all as specified and directed.
22M&L for loop type insulator, vitreous porcelain white ,brown or green large size over all dimension 90 X 140mm, clearance of the hole 25.5mm for stay assembly complete all as specified and directed.
23M&L for stay assembly with 20mm dia rod complete with accessories as shown in electrical plate No 1 (Loop type insulator, stay clamps, excavation and concrete measured separately)complete all as specified and directed.
24M & L for galvanized steel wire with 4 mm dia as in cradle guard including dismantling old unserviceable cradle guard complete all as specified and directed.
25Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x600mm x 6mm thick buried directly in ground with earth pit not less than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized strip of 32 mm earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanized iron pipe 40 mm bore (light grade) including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm dia MS bar funnel wire mesh 20 mm bore galvanized iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 5 of SSR part 1 including testing on completion all as specified and directed. incl demolition to existing one complete.
26M & L for pole LT/HT painting surfaces of any description steel, iron etc . After preparation of old surface of poles including pole fittings such as cross arms of any description, anti-climbing devices, nut, bolts etc. incl scrapping and rubbing etc and applying two coats of aluminum paint providing including numbering of poles complete all as specified and directed.
27Taking out un-serviceable/faulty cable of any grade / type / class of size of 16 Sq mmto 50 Sq mm 4 core /3.5 core / core for repair / replacement from pole / wall / cable duct under ground trench etc from site of work all as specified and directed. (Note- Excavation and earth work shall be measured and paid separately)
28All as per item no-29 above but size ranging from 95 sqmm 3 core/3.5coreLT/HT cable all as specified and directed. (Note- Excavation and earth work shall be measured and paid separately)
29Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminiium conductor, 11000 volts grade cross sectional area 95 sq. mm 3 Core earthed complete all as specified and directed.
30Supply, laying, jointing and testing, XLPE insulated, armoured,heavy duty, electric LT UG cable with multi stranded aluminium conductor, 1100 Volts grade, of size 3.5 core 95Sqmm complete all as specified and directed.
31All as per item No 31 but 50 Sqmm 3.5 corecomplete all as specified and directed.
32All as per item No 31 but 35 Sqmm 3.5 corecomplete all as specified and directed.
33All as per item No 31 but 25 Sqmm 3.5 corecomplete all as specified and directed.
34All as per item No 31 but 16 Sqmm 4 corecomplete all as specified and directed.
35Cable joining kit for LT cable for outdoor termination heat shrink type joint complete with joining material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 sqmm to 50 sqmm
36Cable joining kit for LT cable for outdoor termination heat shrink type joint complete with joining material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size70 sqmm to 150 sqmmcomplete all as specified and directed.
37Cable joining kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size95 sqmmincluding testing after jointing complete all as specified & directed.
38M & L for cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for set of three core XLPE aluminium conductor cable of size95sqmm including testing after jointing complete all as specified & directed
39Dismantling the existing worn out jumpers of two pole/four pole structure and replacing with new set of jumpers of ACSR Conductor of size 6/1x2.59 from overheadline to AB switch, edge fuse and transformer incl PVC RYB sleeves aluminium thimbles etccomplete all as specified and directed.
40M&L for vice type connectors consisting of two brass plates, and two steel bolts and nuts for 2 conductors of equal or unequal sizes for non-tension connections including treatment of connector and ACSR conductor with conductor jolly of size 10 to 13 mmcomplete all as specified and directed.
41Restringing and stretching of existing sagged LT/HT ACSR conductor of any size on OH electric line of any length on existing poles after disconnection of binding wires (dismantling & taking down) service connection etc and making, binding and service connectioncomplete all as specified and directed.
42M & L for overhead line spacers/separators made of cpvc 1/2" pipe, 300 mm long fixed with MS shade/clamp at both end of fixing the ACSR conductors complete fixing with insulators as per sample incl taking down old unsv one all as specified and directed.
43M & L for GI Pipe light grade complete with fittings laid in floor/ trenches/ wall as cable protection of 100 mm dia all as specified and directed.
44All as per item No 44 but ofsize80 mm diacomplete all as specified and directed.
45M & L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (9 metres long) including painting of pole 1.2 RM height from top of coping of the pole and writing the pole no complete all as specified and directed.
46M&L for HT/LT cable route indicator precast made from PCC 1:3:6 of size 600mm x 230mm x 100 including excavation PCC for foundationand painting and writing as "11 kv cable"incl preparation of surfaces both sides all as specified and directed.
47M&L forPCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
48Boring of holes under road, pavement, hard standing by trenches technology using ultra sound technique and necessary machine including HDPE pipe of 100mm dia suitable for 0.4 mpa working pressurecomplete all as specified and directed.
49M&L for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
50M&L for PCC 1:2:4 type B-0 using 12.5 mm graded BT stone aggregate as in bed block for hold fast or coping including necessary form work complete all as specified and directed.
51Supply, installing in replacement, LT panel board 440 Volts, 4 wire, 3 phase factory fabricatedpowder coated, cubical, weather and vermin proof outdoor kiosk type, front & back opening, floor mounted made out of 3.15 mm thick CRCA sheet alongwith both side openable & automatic self closing door. The panel shall consist following accessories with aluminium bus bar of capacity 400 Amp mounted on hygroscopic insulators. Cable glands shall be mounted on glass fibre sheet of suitable size at the botto of the panel with grouting 4 Nos angle iron supportsof size 50x50x6mm in PCC 1:2:4 type B1 complete with separate compartment for housingwith proper arrangement for air circulation and including provision for automatic function of capacitors to maintain deserved power factor alongwithaccessories all as specified and directed. (a)MCCB 4 pole, 400 Amps, 415 Volts, rupturing capacity 50 KA - 01 No (incoming). (b)MCCB 4 pole, 160 Amps, 415 Volts, rupturing capacity 16 KA - 02 No (outgoing). (c)MCCB 4 pole, 200 Amps, 415 Volts, rupturing capacity 36 KA - 01 No (outgoing). (d)MCCB 4 pole, 100 Amps, 415 Volts, rupturing capacity 16 KA - 01 No (outgoing). (e) Volt meter analog type 0 to 500 volts with selector switch-01 nos. (f) Ammeter analog type 0 to 400 Amps with CTs & selector switch-01 Nos. (g)Phase indication lamp LED type ( set of three ) -01 set.
52M & L in replacement of MCCBs 400 Amps, 415 volts, 4 pole rupturing capacity 36 KA in existing LT panel including making existing electrical connection as per existing system all as specified and directed.
53All as per item No 53 above but of capacity 250 Amps complete all as specified and directed.
54All as per item No 53 above but of capacity 200 Amps complete all as specified and directed.
55All as per item No 53 above but of capacity 160 Amps complete all as specified and directed.
56Taking out existing street light connection, bracket, jnunction box etc and refixing the same as previous condition and restore the street light connection and testingcomplete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail